Normalized to: McCarrick, H.
[1]
oai:arXiv.org:2003.08949 [pdf] - 2067603
Simons Observatory Microwave SQUID Multiplexing Readout -- Cryogenic RF
Amplifier and Coaxial Chain Design
Rao, Mayuri Sathyanarayana;
Silva-Feaver, Maximiliano;
Ali, Aamir;
Arnold, Kam;
Ashton, Peter;
Dober, Bradley J.;
Duell, Cody J.;
Duff, Shannon M.;
Galitzki, Nicholas;
Healy, Erin;
Henderson, Shawn;
Ho, Shuay-Pwu Patty;
Hoh, Jonathan;
Kofman, Anna M.;
Kusaka, Akito;
Lee, Adrian T.;
Mangu, Aashrita;
Mathewson, Justin;
Mauskopf, Philip;
McCarrick, Heather;
Moore, Jenna;
Niemack, Michael D.;
Raum, Christopher;
Salatino, Maria;
Sasse, Trevor;
Seibert, Joseph;
Simon, Sara M.;
Staggs, Suzanne;
Stevens, Jason R.;
Teply, Grant;
Thornton, Robert;
Ullom, Joel;
Vavagiakis, Eve M.;
Westbrook, Benjamin;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2020-03-19
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic
Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with
large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC).
To enable the readout of \bigO(10,000) detectors in each of the four telescopes
of SO, we will employ the microwave SQUID multiplexing technology. With a
targeted multiplexing factor of \bigO{(1,000)}, microwave SQUID multiplexing
has never been deployed on the scale needed for SO. Here we present the design
of the cryogenic coaxial cable and RF component chain that connects room
temperature readout electronics to superconducting resonators that are coupled
to Transition Edge Sensor bolometers operating at sub-Kelvin temperatures. We
describe design considerations including cryogenic RF component selection,
system linearity, noise, and thermal power dissipation.
[2]
oai:arXiv.org:2001.07848 [pdf] - 2097303
Small Aperture Telescopes for the Simons Observatory
Ali, Aamir M.;
Adachi, Shunsuke;
Arnold, Kam;
Ashton, Peter;
Bazarko, Andrew;
Chinone, Yuji;
Coppi, Gabriele;
Corbett, Lance;
Crowley, Kevin D;
Crowley, Kevin T;
Devlin, Mark;
Dicker, Simon;
Duff, Shannon;
Ellis, Chris;
Galitzki, Nicholas;
Goeckner-Wald, Neil;
Harrington, Kathleen;
Healy, Erin;
Hill, Charles A;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Keating, Brian;
Kiuchi, Kenji;
Kusaka, Akito;
Lee, Adrian T;
Ludlam, Michael;
Mangu, Aashrita;
Matsuda, Frederick;
McCarrick, Heather;
Nati, Federico;
Niemack, Michael D.;
Nishino, Haruki;
Orlowski-Scherer, John;
Rao, Mayuri Sathyanarayana;
Raum, Christopher;
Sakurai, Yuki;
Salatino, Maria;
Sasse, Trevor;
Seibert, Joseph;
Sierra, Carlos;
Silva-Feaver, Maximiliano;
Spisak, Jacob;
Simon, Sara M;
Staggs, Suzanne;
Tajima, Osamu;
Teply, Grant;
Tsan, Tran;
Wollack, Edward;
Westbrook, Bejamin;
Xu, Zhilei;
Zannoni, Mario;
Zhu, Ningfeng
Submitted: 2020-01-21, last modified: 2020-01-23
The Simons Observatory (SO) is an upcoming cosmic microwave background (CMB)
experiment located on Cerro Toco, Chile, that will map the microwave sky in
temperature and polarization in six frequency bands spanning 27 to 285 GHz. SO
will consist of one 6-meter Large Aperture Telescope (LAT) fielding
$\sim$30,000 detectors and an array of three 0.42-meter Small Aperture
Telescopes (SATs) fielding an additional 30,000 detectors. This synergy will
allow for the extremely sensitive characterization of the CMB over angular
scales ranging from an arcmin to tens of degrees, enabling a wide range of
scientific output. Here we focus on the SATs targeting degree angular scales
with successive dichroic instruments observing at Mid-Frequency (MF: 93/145
GHz), Ultra-High-Frequency (UHF: 225/285 GHz), and Low-Frequency (LF: 27/39
GHz). The three SATs will be able to map $\sim$10% of the sky to a noise level
of 2 $\mu$K-arcmin when combining 93 and 145 GHz. The multiple frequency bands
will allow the CMB to be separated from galactic foregrounds (primarily
synchrotron and dust), with the primary science goal of characterizing the
primordial tensor-to-scalar ratio, $r$, at a target level of $\sigma
\left(r\right) \approx 0.003$.
[3]
oai:arXiv.org:1907.08284 [pdf] - 1976842
The Simons Observatory: Astro2020 Decadal Project Whitepaper
The Simons Observatory Collaboration;
Abitbol, Maximilian H.;
Adachi, Shunsuke;
Ade, Peter;
Aguirre, James;
Ahmed, Zeeshan;
Aiola, Simone;
Ali, Aamir;
Alonso, David;
Alvarez, Marcelo A.;
Arnold, Kam;
Ashton, Peter;
Atkins, Zachary;
Austermann, Jason;
Awan, Humna;
Baccigalupi, Carlo;
Baildon, Taylor;
Lizancos, Anton Baleato;
Barron, Darcy;
Battaglia, Nick;
Battye, Richard;
Baxter, Eric;
Bazarko, Andrew;
Beall, James A.;
Bean, Rachel;
Beck, Dominic;
Beckman, Shawn;
Beringue, Benjamin;
Bhandarkar, Tanay;
Bhimani, Sanah;
Bianchini, Federico;
Boada, Steven;
Boettger, David;
Bolliet, Boris;
Bond, J. Richard;
Borrill, Julian;
Brown, Michael L.;
Bruno, Sarah Marie;
Bryan, Sean;
Calabrese, Erminia;
Calafut, Victoria;
Calisse, Paolo;
Carron, Julien;
Carl, Fred. M;
Cayuso, Juan;
Challinor, Anthony;
Chesmore, Grace;
Chinone, Yuji;
Chluba, Jens;
Cho, Hsiao-Mei Sherry;
Choi, Steve;
Clark, Susan;
Clarke, Philip;
Contaldi, Carlo;
Coppi, Gabriele;
Cothard, Nicholas F.;
Coughlin, Kevin;
Coulton, Will;
Crichton, Devin;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
D'Ewart, John M.;
Dünner, Rolando;
de Haan, Tijmen;
Devlin, Mark;
Dicker, Simon;
Dober, Bradley;
Duell, Cody J.;
Duff, Shannon;
Duivenvoorden, Adri;
Dunkley, Jo;
Bouhargani, Hamza El;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Fergusson, James;
Ferraro, Simone;
Fluxà, Pedro;
Freese, Katherine;
Frisch, Josef C.;
Frolov, Andrei;
Fuller, George;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Ghersi, Jose Tomas Galvez;
Gao, Jiansong;
Gawiser, Eric;
Gerbino, Martina;
Gluscevic, Vera;
Goeckner-Wald, Neil;
Golec, Joseph;
Gordon, Sam;
Gralla, Megan;
Green, Daniel;
Grigorian, Arpi;
Groh, John;
Groppi, Chris;
Guan, Yilun;
Gudmundsson, Jon E.;
Halpern, Mark;
Han, Dongwon;
Hargrave, Peter;
Harrington, Kathleen;
Hasegawa, Masaya;
Hasselfield, Matthew;
Hattori, Makoto;
Haynes, Victor;
Hazumi, Masashi;
Healy, Erin;
Henderson, Shawn W.;
Hensley, Brandon;
Hervias-Caimapo, Carlos;
Hill, Charles A.;
Hill, J. Colin;
Hilton, Gene;
Hilton, Matt;
Hincks, Adam D.;
Hinshaw, Gary;
Hložek, Renée;
Ho, Shirley;
Ho, Shuay-Pwu Patty;
Hoang, Thuong D.;
Hoh, Jonathan;
Hotinli, Selim C.;
Huang, Zhiqi;
Hubmayr, Johannes;
Huffenberger, Kevin;
Hughes, John P.;
Ijjas, Anna;
Ikape, Margaret;
Irwin, Kent;
Jaffe, Andrew H.;
Jain, Bhuvnesh;
Jeong, Oliver;
Johnson, Matthew;
Kaneko, Daisuke;
Karpel, Ethan D.;
Katayama, Nobuhiko;
Keating, Brian;
Keskitalo, Reijo;
Kisner, Theodore;
Kiuchi, Kenji;
Klein, Jeff;
Knowles, Kenda;
Kofman, Anna;
Koopman, Brian;
Kosowsky, Arthur;
Krachmalnicoff, Nicoletta;
Kusaka, Akito;
LaPlante, Phil;
Lashner, Jacob;
Lee, Adrian;
Lee, Eunseong;
Lewis, Antony;
Li, Yaqiong;
Li, Zack;
Limon, Michele;
Linder, Eric;
Liu, Jia;
Lopez-Caraballo, Carlos;
Louis, Thibaut;
Lungu, Marius;
Madhavacheril, Mathew;
Mak, Daisy;
Maldonado, Felipe;
Mani, Hamdi;
Mates, Ben;
Matsuda, Frederick;
Maurin, Loïc;
Mauskopf, Phil;
May, Andrew;
McCallum, Nialh;
McCarrick, Heather;
McKenney, Chris;
McMahon, Jeff;
Meerburg, P. Daniel;
Mertens, James;
Meyers, Joel;
Miller, Amber;
Mirmelstein, Mark;
Moodley, Kavilan;
Moore, Jenna;
Munchmeyer, Moritz;
Munson, Charles;
Murata, Masaaki;
Naess, Sigurd;
Namikawa, Toshiya;
Nati, Federico;
Navaroli, Martin;
Newburgh, Laura;
Nguyen, Ho Nam;
Nicola, Andrina;
Niemack, Mike;
Nishino, Haruki;
Nishinomiya, Yume;
Orlowski-Scherer, John;
Pagano, Luca;
Partridge, Bruce;
Perrotta, Francesca;
Phakathi, Phumlani;
Piccirillo, Lucio;
Pierpaoli, Elena;
Pisano, Giampaolo;
Poletti, Davide;
Puddu, Roberto;
Puglisi, Giuseppe;
Raum, Chris;
Reichardt, Christian L.;
Remazeilles, Mathieu;
Rephaeli, Yoel;
Riechers, Dominik;
Rojas, Felipe;
Rotti, Aditya;
Roy, Anirban;
Sadeh, Sharon;
Sakurai, Yuki;
Salatino, Maria;
Rao, Mayuri Sathyanarayana;
Saunders, Lauren;
Schaan, Emmanuel;
Schmittfull, Marcel;
Sehgal, Neelima;
Seibert, Joseph;
Seljak, Uros;
Shellard, Paul;
Sherwin, Blake;
Shimon, Meir;
Sierra, Carlos;
Sievers, Jonathan;
Sifon, Cristobal;
Sikhosana, Precious;
Silva-Feaver, Maximiliano;
Simon, Sara M.;
Sinclair, Adrian;
Smith, Kendrick;
Sohn, Wuhyun;
Sonka, Rita;
Spergel, David;
Spisak, Jacob;
Staggs, Suzanne T.;
Stein, George;
Stevens, Jason R.;
Stompor, Radek;
Suzuki, Aritoki;
Tajima, Osamu;
Takakura, Satoru;
Teply, Grant;
Thomas, Daniel B.;
Thorne, Ben;
Thornton, Robert;
Trac, Hy;
Treu, Jesse;
Tsai, Calvin;
Tucker, Carole;
Ullom, Joel;
Vagnozzi, Sunny;
van Engelen, Alexander;
Van Lanen, Jeff;
Van Winkle, Daniel D.;
Vavagiakis, Eve M.;
Vergès, Clara;
Vissers, Michael;
Wagoner, Kasey;
Walker, Samantha;
Wang, Yuhan;
Ward, Jon;
Westbrook, Ben;
Whitehorn, Nathan;
Williams, Jason;
Williams, Joel;
Wollack, Edward;
Xu, Zhilei;
Yasini, Siavash;
Young, Edward;
Yu, Byeonghee;
Yu, Cyndia;
Zago, Fernando;
Zannoni, Mario;
Zhang, Hezi;
Zheng, Kaiwen;
Zhu, Ningfeng;
Zonca, Andrea
Submitted: 2019-07-16
The Simons Observatory (SO) is a ground-based cosmic microwave background
(CMB) experiment sited on Cerro Toco in the Atacama Desert in Chile that
promises to provide breakthrough discoveries in fundamental physics, cosmology,
and astrophysics. Supported by the Simons Foundation, the Heising-Simons
Foundation, and with contributions from collaborating institutions, SO will see
first light in 2021 and start a five year survey in 2022. SO has 287
collaborators from 12 countries and 53 institutions, including 85 students and
90 postdocs.
The SO experiment in its currently funded form ('SO-Nominal') consists of
three 0.4 m Small Aperture Telescopes (SATs) and one 6 m Large Aperture
Telescope (LAT). Optimized for minimizing systematic errors in polarization
measurements at large angular scales, the SATs will perform a deep,
degree-scale survey of 10% of the sky to search for the signature of primordial
gravitational waves. The LAT will survey 40% of the sky with arc-minute
resolution. These observations will measure (or limit) the sum of neutrino
masses, search for light relics, measure the early behavior of Dark Energy, and
refine our understanding of the intergalactic medium, clusters and the role of
feedback in galaxy formation.
With up to ten times the sensitivity and five times the angular resolution of
the Planck satellite, and roughly an order of magnitude increase in mapping
speed over currently operating ("Stage 3") experiments, SO will measure the CMB
temperature and polarization fluctuations to exquisite precision in six
frequency bands from 27 to 280 GHz. SO will rapidly advance CMB science while
informing the design of future observatories such as CMB-S4.
[4]
oai:arXiv.org:1711.02523 [pdf] - 1723973
Development of Multi-Chroic MKIDs for Next-Generation CMB Polarization
Studies
Johnson, B. R.;
Flanigan, D.;
Abitbol, M. H.;
Ade, P. A. R.;
Bryan, S.;
Cho, H. -M.;
Datta, R.;
Day, P.;
Doyle, S.;
Irwin, K.;
Jones, G.;
Li, D.;
Mauskopf, P.;
McCarrick, H.;
McMahon, J.;
Miller, A.;
Pisano, G.;
Song, Y.;
Surdi, H.;
Tucker, C.
Submitted: 2017-11-07, last modified: 2018-07-29
We report on the status of an ongoing effort to develop arrays of
horn-coupled, polarization-sensitive microwave kinetic inductance detectors
(MKIDs) that are each sensitive to two spectral bands between 125 and 280 GHz.
These multi-chroic MKID arrays are tailored for next-generation,
large-detector-count experiments that are being designed to simultaneously
characterize the polarization properties of both the cosmic microwave
background (CMB) and Galactic dust emission. We present our device design and
describe laboratory-based measurement results from two 23-element prototype
arrays. From dark measurements of our first engineering array we demonstrated a
multiplexing factor of 92, showed the resonators respond to bath temperature
changes as expected, and found that the fabrication yield was 100%. From our
first optically loaded array we found the MKIDs respond to millimeter-wave
pulses, additional optical characterization measurements are ongoing. We end by
discussing our plans for scaling up this technology to kilo-pixel arrays over
the next two years.
[5]
oai:arXiv.org:1710.02239 [pdf] - 1641296
Design and performance of dual-polarization lumped-element kinetic
inductance detectors for millimeter-wave polarimetry
McCarrick, H.;
Jones, G.;
Johnson, B. R.;
Abitbol, M. H.;
Ade, P. A. R.;
Bryan, S.;
Day, P.;
Essinger-Hileman, T.;
Flanigan, D.;
Leduc, H. G.;
Limon, M.;
Mauskopf, P.;
Miller, A.;
Tucker, C.
Submitted: 2017-10-05, last modified: 2017-11-19
Lumped-element kinetic inductance detectors (LEKIDs) are an attractive
technology for millimeter-wave observations that require large arrays of
extremely low-noise detectors. We designed, fabricated and characterized
64-element (128 LEKID) arrays of horn-coupled, dual-polarization LEKIDs
optimized for ground-based CMB polarimetry. Our devices are sensitive to two
orthogonal polarizations in a single spectral band centered on 150 GHz with
$\Delta\nu/\nu=0.2$. The $65\times 65$ mm square arrays are designed to be
tiled into the focal plane of an optical system. We demonstrate the viability
of these dual-polarization LEKIDs with laboratory measurements. The LEKID
modules are tested with an FPGA-based readout system in a sub-kelvin cryostat
that uses a two-stage adiabatic demagnetization refrigerator. The devices are
characterized using a blackbody and a millimeter-wave source. The polarization
properties are measured with a cryogenic stepped half-wave plate. We measure
the resonator parameters and the detector sensitivity, noise spectrum, dynamic
range, and polarization response. The resonators have internal quality factors
approaching $1\times 10^{6}$. The detectors have uniform response between
orthogonal polarizations and a large dynamic range. The detectors are
photon-noise limited above 1 pW of absorbed power. The noise-equivalent
temperatures under a 3.4 K blackbody load are $<100~\mu\mathrm{K\sqrt{s}}$. The
polarization fractions of detectors sensitive to orthogonal polarizations are
>80%. The entire array is multiplexed on a single readout line, demonstrating a
multiplexing factor of 128. The array and readout meet the requirements for 4
arrays to be read out simultaneously for a multiplexing factor of 512. This
laboratory study demonstrates the first dual-polarization LEKID array optimized
for CMB polarimetry and shows the readiness of the detectors for on-sky
observations.
[6]
oai:arXiv.org:1510.06609 [pdf] - 1579736
Photon noise from chaotic and coherent millimeter-wave sources measured
with horn-coupled, aluminum lumped-element kinetic inductance detectors
Flanigan, Daniel;
McCarrick, Heather;
Jones, Glenn;
Johnson, Bradley R.;
Abitbol, Maximilian H.;
Ade, Peter;
Araujo, Derek;
Bradford, Kristi;
Cantor, Robin;
Che, George;
Day, Peter K.;
Doyle, Simon;
Kjellstrand, Carl Bjorn;
LeDuc, Henry G;
Limon, Michele;
Luu, Vy;
Mauskopf, Philip;
Miller, Amber;
Mroczkowski, Tony;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2015-10-22, last modified: 2017-05-24
We report photon-noise limited performance of horn-coupled, aluminum
lumped-element kinetic inductance detectors at millimeter wavelengths. The
detectors are illuminated by a millimeter-wave source that uses an active
multiplier chain to produce radiation between 140 and 160 GHz. We feed the
multiplier with either amplified broadband noise or a continuous-wave tone from
a microwave signal generator. We demonstrate that the detector response over a
40 dB range of source power is well-described by a simple model that considers
the number of quasiparticles. The detector noise-equivalent power (NEP) is
dominated by photon noise when the absorbed power is greater than approximately
1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \,
\mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher
source power levels we observe the relationships between noise and power
expected from the photon statistics of the source signal: $\mathrm{NEP} \propto
P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for
continuous-wave (coherent) illumination.
[7]
oai:arXiv.org:1701.08461 [pdf] - 1581309
High quality factor manganese-doped aluminum lumped-element kinetic
inductance detectors sensitive to frequencies below 100 GHz
Jones, G.;
Johnson, B. R.;
Abitbol, M. H.;
Ade, P. A. R.;
Bryan, S.;
Cho, H. -M.;
Day, P.;
Flanigan, D.;
Irwin, K. D.;
Li, D.;
Mauskopf, P.;
McCarrick, H.;
Miller, A.;
Song, Y. R.;
Tucker, C.
Submitted: 2017-01-29, last modified: 2017-04-15
Aluminum lumped-element kinetic inductance detectors (LEKIDs) sensitive to
millimeter-wave photons have been shown to exhibit high quality factors, making
them highly sensitive and multiplexable. The superconducting gap of aluminum
limits aluminum LEKIDs to photon frequencies above 100 GHz. Manganese-doped
aluminum (Al-Mn) has a tunable critical temperature and could therefore be an
attractive material for LEKIDs sensitive to frequencies below 100 GHz if the
internal quality factor remains sufficiently high when manganese is added to
the film. To investigate, we measured some of the key properties of Al-Mn
LEKIDs. A prototype eight-element LEKID array was fabricated using a 40 nm
thick film of Al-Mn deposited on a 500 {\mu}m thick high-resistivity,
float-zone silicon substrate. The manganese content was 900 ppm, the measured
$T_c = 694\pm1$ mK, and the resonance frequencies were near 150 MHz. Using
measurements of the forward scattering parameter $S_{21}$ at various bath
temperatures between 65 and 250 mK, we determined that the Al-Mn LEKIDs we
fabricated have internal quality factors greater than $2 \times 10^5$, which is
high enough for millimeter-wave astrophysical observations. In the dark
conditions under which these devices were measured, the fractional frequency
noise spectrum shows a shallow slope that depends on bath temperature and probe
tone amplitude, which could be two-level system noise. The anticipated white
photon noise should dominate this level of low-frequency noise when the
detectors are illuminated with millimeter-waves in future measurements. The
LEKIDs responded to light pulses from a 1550 nm light-emitting diode, and we
used these light pulses to determine that the quasiparticle lifetime is 60
{\mu}s.
[8]
oai:arXiv.org:1609.06352 [pdf] - 1492815
Magnetic field dependence of the internal quality factor and noise
performance of lumped-element kinetic inductance detectors
Flanigan, Daniel;
Johnson, Bradley R.;
Abitbol, Maximilian H.;
Bryan, Sean;
Cantor, Robin;
Day, Peter K.;
Jones, Glenn;
Mauskopf, Philip;
McCarrick, Heather;
Miller, Amber;
Zmuidzinas, Jonas
Submitted: 2016-09-20
We present a technique for increasing the internal quality factor of kinetic
inductance detectors (KIDs) by nulling ambient magnetic fields with a properly
applied magnetic field. The KIDs used in this study are made from thin-film
aluminum, they are mounted inside a light-tight package made from bulk
aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film
aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \,
\mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2
\, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient
magnetic fields as small as approximately $30 \, \mathrm{\mu T}$ can produce
vortices in the thin-film aluminum as it transitions because the bulk aluminum
package has not yet transitioned and therefore is not yet shielding. These
vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$
and ultimately produce low internal quality factors in the thin-film
superconducting resonators. We show that by controlling the strength of the
magnetic field present when the thin film transitions, we can control the
internal quality factor of the resonators. We also compare the noise
performance with and without vortices present, and find no evidence for excess
noise beyond the increase in amplifier noise, which is expected with increasing
loss.
[9]
oai:arXiv.org:1607.03796 [pdf] - 1441570
Polarization Sensitive Multi-Chroic MKIDs
Johnson, Bradley R.;
Flanigan, Daniel;
Abitbol, Maximilian H.;
Ade, Peter A. R.;
Bryan, Sean;
Cho, Hsiao-Mei;
Datta, Rahul;
Day, Peter;
Doyle, Simon;
Irwin, Kent;
Jones, Glenn;
Kernasovskiy, Sarah;
Li, Dale;
Mauskopf, Phil;
McCarrick, Heather;
McMahon, Jeff;
Miller, Amber;
Pisano, Giampaolo;
Song, Yanru;
Surdi, Harshad;
Tucker, Carole
Submitted: 2016-07-13
We report on the development of scalable prototype microwave kinetic
inductance detector (MKID) arrays tailored for future multi-kilo-pixel
experiments that are designed to simultaneously characterize the polarization
properties of both the cosmic microwave background (CMB) and Galactic dust
emission. These modular arrays are composed of horn-coupled,
polarization-sensitive MKIDs, and each pixel has four detectors: two
polarizations in two spectral bands between 125 and 280 GHz. A horn is used to
feed each array element, and a planar orthomode transducer, composed of two
waveguide probe pairs, separates the incoming light into two linear
polarizations. Diplexers composed of resonant-stub band-pass filters separate
the radiation into 125 to 170 GHz and 190 to 280 GHz pass bands. The
millimeter-wave power is ultimately coupled to a hybrid co-planar waveguide
microwave kinetic inductance detector using a novel, broadband circuit
developed by our collaboration. Electromagnetic simulations show the expected
absorption efficiency of the detector is approximately 90%. Array fabrication
will begin in the summer of 2016.
[10]
oai:arXiv.org:1607.03448 [pdf] - 1531012
Development of dual-polarization LEKIDs for CMB observations
McCarrick, Heather;
Abitbol, Maximilian H.;
Ade, Peter A. R.;
Barry, Peter;
Bryan, Sean;
Che, George;
Day, Peter;
Doyle, Simon;
Flanigan, Daniel;
Johnson, Bradley R.;
Jones, Glenn;
LeDuc, Henry G.;
Limon, Michele;
Mauskopf, Philip;
Miller, Amber;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2016-07-12
We discuss the design considerations and initial measurements from arrays of
dual-polarization, lumped element kinetic inductance detectors (LEKIDs)
nominally designed for cosmic microwave background (CMB) studies. The detectors
are horn-coupled, and each array element contains two single-polarization
LEKIDs, which are made from thin-film aluminum and optimized for a single
spectral band centered on 150 GHz. We are developing two array architectures,
one based on 160 micron thick silicon wafers and the other based on
silicon-on-insulator (SOI) wafers with a 30 micron thick device layer. The
20-element test arrays (40 LEKIDs) are characterized with both a
linearly-polarized electronic millimeter wave source and a thermal source. We
present initial measurements including the noise spectra, noise-equivalent
temperature, and responsivity. We discuss future testing and further design
optimizations to be implemented.
[11]
oai:arXiv.org:1512.01847 [pdf] - 1347758
A Titanium Nitride Absorber for Controlling Optical Crosstalk in
Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P. A. R.;
Bradford, K.;
Bryan, S.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2015-12-06
We discuss the design and measured performance of a titanium nitride (TiN)
mesh absorber we are developing for controlling optical crosstalk in
horn-coupled lumped-element kinetic inductance detector arrays for
millimeter-wavelengths. This absorber was added to the fused silica
anti-reflection coating attached to previously-characterized, 20-element
prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon
substrates. To test the TiN crosstalk absorber, we compared the measured
response and noise properties of LEKID arrays with and without the TiN mesh.
For this test, the LEKIDs were illuminated with an adjustable, incoherent
electronic millimeter-wave source. Our measurements show that the optical
crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on
average, so the approach is effective and a viable candidate for future
kilo-pixel arrays.
[12]
oai:arXiv.org:1509.04658 [pdf] - 1347523
WSPEC: A waveguide filter-bank focal plane array spectrometer for
millimeter wave astronomy and cosmology
Bryan, Sean;
Aguirre, James;
Che, George;
Doyle, Simon;
Flanigan, Daniel;
Groppi, Christopher;
Johnson, Bradley;
Jones, Glenn;
Mauskopf, Philip;
McCarrick, Heather;
Monfardini, Alessandro;
Mroczkowski, Tony
Submitted: 2015-09-15
Imaging and spectroscopy at (sub-)millimeter wavelengths are key frontiers in
astronomy and cosmology. Large area spectral surveys with moderate spectral
resolution (R=50-200) will be used to characterize large scale structure and
star formation through intensity mapping surveys in emission lines such as the
CO rotational transitions. Such surveys will also be used to study the SZ
effect, and will detect the emission lines and continuum spectrum of individual
objects. WSPEC is an instrument proposed to target these science goals. It is a
channelizing spectrometer realized in rectangular waveguide, fabricated using
conventional high-precision metal machining. Each spectrometer is coupled to
free space with a machined feed horn, and the devices are tiled into a 2D array
to fill the focal plane of the telescope. The detectors will be aluminum
Lumped-Element Kinetic Inductance Detectors (LEKIDs). To target the CO lines
and SZ effect, we will have bands at 135-175 GHz and 190-250 GHz, each
Nyquist-sampled at R~200 resolution. Here we discuss the instrument concept and
design, and successful initial testing of a WR10 (i.e. 90 GHz) prototype
spectrometer. We recently tested a WR5 (180 GHz) prototype to verify that the
concept works at higher frequencies, and also designed a resonant backshort
structure that may further increase the optical efficiency. We are making
progress towards integrating a spectrometer with a LEKID array and deploying a
prototype device to a telescope for first light.
[13]
oai:arXiv.org:1407.7749 [pdf] - 971383
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic
Inductance Detectors for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P.;
Araujo, D.;
Bradford, K.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Luu, V.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2014-07-29, last modified: 2015-03-26
We discuss the design, fabrication, and testing of prototype horn-coupled,
lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic
microwave background (CMB) studies. The LEKIDs are made from a thin aluminum
film deposited on a silicon wafer and patterned using standard
photolithographic techniques at STAR Cryoelectronics, a commercial device
foundry. We fabricated twenty-element arrays, optimized for a spectral band
centered on 150 GHz, to test the sensitivity and yield of the devices as well
as the multiplexing scheme. We characterized the detectors in two
configurations. First, the detectors were tested in a dark environment with the
horn apertures covered, and second, the horn apertures were pointed towards a
beam-filling cryogenic blackbody load. These tests show that the multiplexing
scheme is robust and scalable, the yield across multiple LEKID arrays is 91%,
and the noise-equivalent temperatures (NET) for a 4 K optical load are in the
range 26$\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}$.
[14]
oai:arXiv.org:1503.06528 [pdf] - 969448
WSPEC: A Waveguide Filter Bank Spectrometer
Che, George;
Bryan, Sean;
Underhill, Matthew;
Mauskopf, Philip;
Groppi, Christopher;
Jones, Glenn;
Johnson, Bradley;
McCarrick, Heather;
Flanigan, Daniel;
Day, Peter
Submitted: 2015-03-23
We have designed, fabricated, and measured a 5-channel prototype spectrometer
pixel operating in the WR10 band to demonstrate a novel moderate-resolution
(R=f/{\Delta}f~100), multi-pixel, broadband, spectrometer concept for mm and
submm-wave astronomy. Our design implements a transmission line filter bank
using waveguide resonant cavities as a series of narrow-band filters, each
coupled to an aluminum kinetic inductance detector (KID). This technology has
the potential to perform the next generation of spectroscopic observations
needed to drastically improve our understanding of the epoch of reionization
(EoR), star formation, and large-scale structure of the universe. We present
our design concept, results from measurements on our prototype device, and the
latest progress on our efforts to develop a 4-pixel demonstrator instrument
operating in the 130-250 GHz band.
[15]
oai:arXiv.org:1503.04684 [pdf] - 957156
Design of Dual-Polarization Horn-Coupled Kinetic Inductance Detectors
for Cosmic Microwave Background Polarimetry
Bryan, Sean;
Bradford, Kristi;
Che, George;
Day, Peter;
Flanigan, Daniel;
Johnson, Bradley R.;
Jones, Glenn;
Kjellstrand, Bjorn;
Limon, Michele;
Mauskopf, Philip;
McCarrick, Heather;
Miller, Amber;
Smiley, Brian
Submitted: 2015-03-16
Mapping the polarization of the Cosmic Microwave Background is yielding
exciting data on the origin of the universe, the reionization of the universe,
and the growth of cosmic structure. Kilopixel arrays represent the current
state of the art, but advances in detector technology are needed to enable the
larger detector arrays needed for future measurements. Here we present a design
for single-band dual-polarization Kinetic Inductance Detectors (KIDs) at 20%
bandwidths centered at 145, 220, and 280 GHz. The detection and readout system
is nearly identical to the successful photon-noise-limited aluminum
Lumped-Element KIDs that have been recently built and tested by some of the
authors. Fabricating large focal plane arrays of the feed horns and
quarter-wave backshorts requires only conventional precision machining. Since
the detectors and readout lines consist only of a single patterned aluminum
layer on a SOI wafer, arrays of the detectors can be built commercially or at a
standard university cleanroom.
[16]
oai:arXiv.org:1407.6249 [pdf] - 880220
A LEKID-based CMB instrument design for large-scale observations in
Greenland
Araujo, D. C.;
Ade, P. A. R.;
Bond, J. R.;
Bradford, K. J.;
Chapman, D.;
Che, G.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C. E.;
Hillbrand, S. N.;
Johnson, B. R.;
Jones, G.;
Limon, M.;
Miller, A. D.;
Mauskopf, P.;
McCarrick, H.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2014-07-10, last modified: 2014-10-10
We present the results of a feasibility study, which examined deployment of a
ground-based millimeter-wave polarimeter, tailored for observing the cosmic
microwave background (CMB), to Isi Station in Greenland. The instrument for
this study is based on lumped-element kinetic inductance detectors (LEKIDs) and
an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The
telescope is mounted inside the receiver and cooled to $<\,4$ K by a
closed-cycle $^4$He refrigerator to reduce background loading on the detectors.
Linearly polarized signals from the sky are modulated with a metal-mesh
half-wave plate that is rotated at the aperture stop of the telescope with a
hollow-shaft motor based on a superconducting magnetic bearing. The modular
detector array design includes at least 2300 LEKIDs, and it can be configured
for spectral bands centered on 150~GHz or greater. Our study considered
configurations for observing in spectral bands centered on 150, 210 and
267~GHz. The entire polarimeter is mounted on a commercial precision rotary air
bearing, which allows fast azimuth scan speeds with negligible vibration and
mechanical wear over time. A slip ring provides power to the instrument,
enabling circular scans (360 degrees of continuous rotation). This mount, when
combined with sky rotation and the latitude of the observation site, produces a
hypotrochoid scan pattern, which yields excellent cross-linking and enables
34\% of the sky to be observed using a range of constant elevation scans. This
scan pattern and sky coverage combined with the beam size (15~arcmin at
150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular
power spectra.
[17]
oai:arXiv.org:1308.0235 [pdf] - 857218
The Detector System for the Stratospheric Kinetic Inductance Polarimeter
(SKIP)
Johnson, B. R.;
Ade, P. A. R.;
Araujo, D.;
Bradford, K. J.;
Chapman, D.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C.;
Hillbrand, S.;
Jones, G.;
Limon, M.;
Mauskopf, P.;
McCarrick, H.;
Miller, A.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2013-08-01, last modified: 2014-01-05
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed
balloon-borne experiment designed to study the cosmic microwave background, the
cosmic infrared background and Galactic dust emission by observing 1133 square
degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden.
The instrument contains 2317 single-polarization, horn-coupled, aluminum
lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be
maintained at 100 mK with an adiabatic demagnetization refrigerator. The
polarimeter operates in two configurations, one sensitive to a spectral band
centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The
detector readout system is based on the ROACH-1 board, and the detectors will
be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone
telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To
minimize detector loading and maximize sensitivity, the entire optical system
will be cooled to 1 K. Linearly polarized sky signals will be modulated with a
metal-mesh half-wave plate that is mounted at the telescope aperture and
rotated by a superconducting magnetic bearing. The observation program consists
of at least two, five-day flights beginning with the 150 GHz observations.