Normalized to: McBride, S.
[1]
oai:arXiv.org:1912.06571 [pdf] - 2014538
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking
for the GAPS Experiment
Rogers, Field;
Xiao, Mengjiao;
Perez, Kerstin;
Boggs, Steven;
Erjavec, Tyler;
Fabris, Lorenzo;
Fuke, Hideyuki;
Hailey, Charles J.;
Kozai, Masayoshi;
Lowell, Alex;
Madden, Norman;
Manghisoni, Massimo;
McBride, Steve;
Re, Valerio;
Riceputi, Elisa;
Saffold, Nathan;
Shimizu, Yuki;
Zampa, Gianluigi
Submitted: 2019-12-13
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150{\deg}C
above liquid nitrogen temperature, have been developed for the General
Antiparticle Spectrometer (GAPS) balloon mission and will form the first such
system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip
detectors have been verified in the lab to provide <4 keV FWHM energy
resolution for X-rays as well as tracking capability for charged particles,
while operating in conditions (~-40{\deg}C and ~1 Pa) achievable on a
long-duration balloon mission with a large detector payload. These
characteristics enable the GAPS silicon tracker system to identify cosmic
antinuclei via a novel technique based on exotic atom formation, de-excitation,
and annihilation. Production and large-scale calibration of ~1000 detectors has
begun for the first GAPS flight, scheduled for late 2021. The detectors
developed for GAPS may also have other applications, for example in heavy
nuclei identification.
[2]
oai:arXiv.org:1906.00054 [pdf] - 1995412
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking
in the GAPS experiment
Rogers, Field;
Xiao, Mengjiao;
Perez, Kerstin M.;
Boggs, Steven;
Erjavec, Tyler;
Fabris, Lorenzo;
Fuke, Hideyuki;
Hailey, Charles J.;
Kozai, Masayoshi;
Lowell, Alex;
Madden, Norman;
Manghisoni, Massimo;
McBride, Steve;
Re, Valerio;
Riceputi, Elisa;
Saffold, Nathan;
Shimizu, Yuki
Submitted: 2019-05-31, last modified: 2019-11-08
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique
geometric, performance, and cost requirements of the General Antiparticle
Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The
GAPS Si(Li) detectors will form the first large-area, relatively
high-temperature Si(Li) detector system with sensitivity to X-rays to operate
at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors
provide the active area, X-ray absorption efficiency, energy resolution, and
particle tracking capability necessary for the GAPS exotic-atom particle
identification technique. In this paper, the detector performance is validated
on the bases of X-ray energy resolution and reconstruction of cosmic minimum
ionizing particle (MIP) signals. We use the established noise model for
semiconductor detectors to distinguish sources of noise due to the detector
from those due to signal processing electronics. We demonstrate that detectors
with either 4 strips or 8 strips can provide the required $\lesssim$4 keV
(FWHM) X-ray energy resolution at flight temperatures of $-35$ to
$-45^{\circ}$C, given the proper choice of signal processing electronics.
Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic
balloon flight, scheduled for late 2021.
[3]
oai:arXiv.org:1509.05717 [pdf] - 1279393
Fine-pitch semiconductor detector for the FOXSI mission
Ishikawa, Shin-nosuke;
Saito, Shinya;
Tajima, Hiroyasu;
Tanaka, Takaaki;
Watanabe, Shin;
Odaka, Hirokazu;
Fukuyama, Taro;
Kokubun, Motohide;
Takahashi, Tadayuki;
Terada, Yukikatsu;
Krucker, Sam;
Christe, Steven;
McBride, Steve;
Glesener, Lindsay
Submitted: 2015-09-18
The Focusing Optics X-ray Solar Imager (FOXSI) is a NASA sounding rocket
mission which will study particle acceleration and coronal heating on the Sun
through high sensitivity observations in the hard X-ray energy band (5-15 keV).
Combining high-resolution focusing X-ray optics and fine-pitch imaging sensors,
FOXSI will achieve superior sensitivity; two orders of magnitude better than
that of the RHESSI satellite. As the focal plane detector, a Double-sided Si
Strip Detector (DSSD) with a front-end ASIC (Application Specific Integrated
Circuit) will fulfill the scientific requirements of spatial and energy
resolution, low energy threshold and time resolution. We have designed and
fabricated a DSSD with a thickness of 500 {\mu}m and a dimension of 9.6 mm x
9.6 mm, containing 128 strips with a pitch of 75 {\mu}m, which corresponds to 8
arcsec at the focal length of 2 m. We also developed a low-noise ASIC specified
to FOXSI. The detector was successfully operated in the laboratory at a
temperature of -20 C and with an applied bias voltage of 300 V, and the energy
resolution of 430 eV at a 14 keV line was achieved. We also demonstrated
fine-pitch imaging successfully by obtaining a shadow image, hence the
implementation of scientific requirements was confirmed.