sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mazzitelli, G.

Normalized to: Mazzitelli, G.

12 article(s) in total. 440 co-authors, from 1 to 7 common article(s). Median position in authors list is 15,5.

[1]  oai:arXiv.org:1808.01892  [pdf] - 1728123
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and Directional Detection of MeV Dark Matter
Comments:
Submitted: 2018-08-06
We propose to achieve the proof-of-principle of the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Each of the technological challenges described in [1,2] will be targeted and hopefully solved by the use of the latest experimental developments and profiting from the low background environment provided by the LNGS underground site. The first phase will focus on the graphene technology for a tritium target and the demonstration of TES microcalorimetry with an energy resolution of better than 0.05 eV for low energy electrons. These technologies will be evaluated using the PTOLEMY prototype, proposed for underground installation, using precision HV controls to step down the kinematic energy of endpoint electrons to match the calorimeter dynamic range and rate capabilities. The second phase will produce a novel implementation of the EM filter that is scalable to the full target size and which demonstrates intrinsic triggering capability for selecting endpoint electrons. Concurrent with the CNB program, we plan to exploit and develop the unique properties of graphene to implement an intermediate program for direct directional detection of MeV dark matter [3,4]. This program will evaluate the radio-purity and scalability of the graphene fabrication process with the goal of using recently identified ultra-high radio-purity CO2 sources. The direct detection of the CNB is a snapshot of early universe dynamics recorded by the thermal relic neutrino yield taken at a time that predates the epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to have a central role in the evolution of the Universe and a direct measurement with PTOLEMY will unequivocally establish the extent to which these predictions match present-day neutrino densities.
[2]  oai:arXiv.org:1807.08174  [pdf] - 1720368
The AMY (Air Microwave Yield) experiment to measure the GHz emission from air shower plasma
Comments: Proceedings of 6th International Conference on Acoustic and Radio EeV Neutrino Detection Activities, Annapolis (Maryland), USA, 2014
Submitted: 2018-07-21
The aim of the Air Microwave Yield (AMY) experiment is to investigate the Molecular Bremsstrahlung Radiation (MBR) emitted from an electron beam induced air-shower. The measurements have been performed with a 510 MeV electron beam at the Beam Test Facility (BTF) of Frascati INFN National Laboratories in a wide frequency range between 1 and 20 GHz. We present the experimental apparatus and the first results of the measurements. Contrary to what have been reported in a previous similar experiment~\cite{Gorham-SLAC}, we have found that the intensity of the emission is strongly influenced by the particular time structure of the accelerator beam. This makes very difficult the interpretation of the emission process and a realistic extrapolation of the emission yield to the plasma generated during the development of an atmospheric shower.
[3]  oai:arXiv.org:1805.10804  [pdf] - 1721139
Calibration of AGILE-GRID with on-ground data and Monte Carlo simulations
Comments: 19 page 12 figures
Submitted: 2018-05-28
AGILE is a mission of the Italian Space Agency (ASI) Scientific Program dedicated to gamma-ray astrophysics, operating in a low Earth orbit since April 23, 2007. It is designed to be a very light and compact instrument, capable of simultaneously detecting and imaging photons in the 18 keV to 60 keV X-ray energy band and in the 30 MeV{50 GeV gamma-ray energy with a good angular resolution (< 1 deg at 1 GeV). The core of the instrument is the Silicon Tracker complemented with a CsI calorimeter and a AntiCoincidence system forming the Gamma Ray Imaging Detector (GRID). Before launch, the GRID needed on-ground calibration with a tagged gamma-ray beam to estimate its performance and validate the Monte Carlo simulation. The GRID was calibrated using a tagged gamma-ray beam with energy up to 500 MeV at the Beam Test Facilities at the INFN Laboratori Nazionali di Frascati. These data are used to validate a GEANT3 based simulation by comparing the data and the Monte Carlo simulation by measuring the angular and energy resolutions. The GRID angular and energy resolutions obtained using the beam agree well with the Monte Carlo simulation. Therefore the simulation can be used to simulate the same performance on-light with high reliability.
[4]  oai:arXiv.org:1707.04591  [pdf] - 1585955
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Battaglieri, Marco; Belloni, Alberto; Chou, Aaron; Cushman, Priscilla; Echenard, Bertrand; Essig, Rouven; Estrada, Juan; Feng, Jonathan L.; Flaugher, Brenna; Fox, Patrick J.; Graham, Peter; Hall, Carter; Harnik, Roni; Hewett, JoAnne; Incandela, Joseph; Izaguirre, Eder; McKinsey, Daniel; Pyle, Matthew; Roe, Natalie; Rybka, Gray; Sikivie, Pierre; Tait, Tim M. P.; Toro, Natalia; Van De Water, Richard; Weiner, Neal; Zurek, Kathryn; Adelberger, Eric; Afanasev, Andrei; Alexander, Derbin; Alexander, James; Antochi, Vasile Cristian; Asner, David Mark; Baer, Howard; Banerjee, Dipanwita; Baracchini, Elisabetta; Barbeau, Phillip; Barrow, Joshua; Bastidon, Noemie; Battat, James; Benson, Stephen; Berlin, Asher; Bird, Mark; Blinov, Nikita; Boddy, Kimberly K.; Bondi, Mariangela; Bonivento, Walter M.; Boulay, Mark; Boyce, James; Brodeur, Maxime; Broussard, Leah; Budnik, Ranny; Bunting, Philip; Caffee, Marc; Caiazza, Sabato Stefano; Campbell, Sheldon; Cao, Tongtong; Carosi, Gianpaolo; Carpinelli, Massimo; Cavoto, Gianluca; Celentano, Andrea; Chang, Jae Hyeok; Chattopadhyay, Swapan; Chavarria, Alvaro; Chen, Chien-Yi; Clark, Kenneth; Clarke, John; Colegrove, Owen; Coleman, Jonathon; Cooke, David; Cooper, Robert; Crisler, Michael; Crivelli, Paolo; D'Eramo, Francesco; D'Urso, Domenico; Dahl, Eric; Dawson, William; De Napoli, Marzio; De Vita, Raffaella; DeNiverville, Patrick; Derenzo, Stephen; Di Crescenzo, Antonia; Di Marco, Emanuele; Dienes, Keith R.; Diwan, Milind; Dongwi, Dongwi Handiipondola; Drlica-Wagner, Alex; Ellis, Sebastian; Ezeribe, Anthony Chigbo; Farrar, Glennys; Ferrer, Francesc; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fiorillo, Giuliana; Fornal, Bartosz; Freyberger, Arne; Frugiuele, Claudia; Galbiati, Cristian; Galon, Iftah; Gardner, Susan; Geraci, Andrew; Gerbier, Gilles; Graham, Mathew; Gschwendtner, Edda; Hearty, Christopher; Heise, Jaret; Henning, Reyco; Hill, Richard J.; Hitlin, David; Hochberg, Yonit; Hogan, Jason; Holtrop, Maurik; Hong, Ziqing; Hossbach, Todd; Humensky, T. B.; Ilten, Philip; Irwin, Kent; Jaros, John; Johnson, Robert; Jones, Matthew; Kahn, Yonatan; Kalantarians, Narbe; Kaplinghat, Manoj; Khatiwada, Rakshya; Knapen, Simon; Kohl, Michael; Kouvaris, Chris; Kozaczuk, Jonathan; Krnjaic, Gordan; Kubarovsky, Valery; Kuflik, Eric; Kusenko, Alexander; Lang, Rafael; Leach, Kyle; Lin, Tongyan; Lisanti, Mariangela; Liu, Jing; Liu, Kun; Liu, Ming; Loomba, Dinesh; Lykken, Joseph; Mack, Katherine; Mans, Jeremiah; Maris, Humphrey; Markiewicz, Thomas; Marsicano, Luca; Martoff, C. J.; Mazzitelli, Giovanni; McCabe, Christopher; McDermott, Samuel D.; McDonald, Art; McKinnon, Bryan; Mei, Dongming; Melia, Tom; Miller, Gerald A.; Miuchi, Kentaro; Nazeer, Sahara Mohammed Prem; Moreno, Omar; Morozov, Vasiliy; Mouton, Frederic; Mueller, Holger; Murphy, Alexander; Neilson, Russell; Nelson, Tim; Neu, Christopher; Nosochkov, Yuri; O'Hare, Ciaran; Oblath, Noah; Orrell, John; Ouellet, Jonathan; Pastore, Saori; Paul, Sebouh; Perelstein, Maxim; Peter, Annika; Phan, Nguyen; Phinney, Nan; Pivovaroff, Michael; Pocar, Andrea; Pospelov, Maxim; Pradler, Josef; Privitera, Paolo; Profumo, Stefano; Raggi, Mauro; Rajendran, Surjeet; Randazzo, Nunzio; Raubenheimer, Tor; Regenfus, Christian; Renshaw, Andrew; Ritz, Adam; Rizzo, Thomas; Rosenberg, Leslie; Rubbia, Andre; Rybolt, Ben; Saab, Tarek; Safdi, Benjamin R.; Santopinto, Elena; Scarff, Andrew; Schneider, Michael; Schuster, Philip; Seidel, George; Sekiya, Hiroyuki; Seong, Ilsoo; Simi, Gabriele; Sipala, Valeria; Slatyer, Tracy; Slone, Oren; Smith, Peter F; Smolinsky, Jordan; Snowden-Ifft, Daniel; Solt, Matthew; Sonnenschein, Andrew; Sorensen, Peter; Spooner, Neil; Srivastava, Brijesh; Stancu, Ion; Strigari, Louis; Strube, Jan; Sushkov, Alexander O.; Szydagis, Matthew; Tanedo, Philip; Tanner, David; Tayloe, Rex; Terrano, William; Thaler, Jesse; Thomas, Brooks; Thorpe, Brianna; Thorpe, Thomas; Tiffenberg, Javier; Tran, Nhan; Trovato, Marco; Tully, Christopher; Tyson, Tony; Vachaspati, Tanmay; Vahsen, Sven; van Bibber, Karl; Vandenbroucke, Justin; Villano, Anthony; Volansky, Tomer; Wang, Guojian; Ward, Thomas; Wester, William; Whitbeck, Andrew; Williams, David A.; Wing, Matthew; Winslow, Lindley; Wojtsekhowski, Bogdan; Yu, Hai-Bo; Yu, Shin-Shan; Yu, Tien-Tien; Zhang, Xilin; Zhao, Yue; Zhong, Yi-Ming
Comments: 102 pages + references
Submitted: 2017-07-14
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
[5]  oai:arXiv.org:1310.4662  [pdf] - 786435
The Air Microwave Yield (AMY) experiment - A laboratory measurement of the microwave emission from extensive air showers
Comments: 3 pages -- EPS-HEP'13 European Physical Society Conference on High Energy Physics (July, 18-24, 2013) at Stockholm, Sweden
Submitted: 2013-10-17
The AMY experiment aims to measure the microwave bremsstrahlung radiation (MBR) emitted by air-showers secondary electrons accelerating in collisions with neutral molecules of the atmosphere. The measurements are performed using a beam of 510 MeV electrons at the Beam Test Facility (BTF) of Frascati INFN National Laboratories. The goal of the AMY experiment is to measure in laboratory conditions the yield and the spectrum of the GHz emission in the frequency range between 1 and 20 GHz. The final purpose is to characterise the process to be used in a next generation detectors of ultra-high energy cosmic rays. A description of the experimental setup and the first results are presented.
[6]  oai:arXiv.org:1212.0368  [pdf] - 1158220
Measurement of the thermal expansion coefficient of an Al-Mg alloy at ultra-low temperatures
Comments: 13 pages, 4 figures
Submitted: 2012-12-03, last modified: 2013-03-11
We describe a result coming from an experiment based on an Al-Mg alloy (~ 5% Mg) suspended bar hit by an electron beam and operated above and below the termperature of transition from superconducting to normal state of the material. The amplitude of the bar first longitudinal mode of oscillation, excited by the beam interacting with the bulk, and the energy deposited by the beam in the bar are the quantities measured by the experiment. These quantities, inserted in the equations describing the mechanism of the mode excitation and complemented by an independent measurement of the specific heat, allow us to determine the linear expansion coefficient of the material.
[7]  oai:arXiv.org:1111.6147  [pdf] - 637683
Characterization of a tagged $\gamma$-ray beam line at the DA$\Phi$NE Beam Test Facility
Comments: 23 pages; 17 figures. Second and final version accepted by Nucl. Instr. & Meth. A
Submitted: 2011-11-26, last modified: 2012-01-19
At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $\gamma$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $\gamma$ rays. A tagged $\gamma$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $\gamma$ rays through bremsstrahlung in a position-sensitive target. The $\gamma$-ray energy is deduced by difference with the post-bremsstrahlung electron energy \cite{prest}-\cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the combined BTF-PTS system as tagged photon beam requires understanding the efficiency of $\gamma$-ray tagging, the probability of fake tagging, the energy resolution and the relation of the PTS hit position versus the $\gamma$-ray energy. This paper describes this study comparing data taken during the AGILE calibration occurred in 2005 with simulation.
[8]  oai:arXiv.org:1112.2600  [pdf] - 450234
First results about on-ground calibration of the Silicon Tracker for the AGILE satellite
Comments: Presented at the 2nd Roma International Conference on Astroparticle Physics 2009, Villa Mondragone, Rome, Italy, May 13-15 2009. Pages 6, Figures 10
Submitted: 2011-12-12
The AGILE scientific instrument has been calibrated with a tagged $\gamma$-ray beam at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF). The goal of the calibration was the measure of the Point Spread Function (PSF) as a function of the photon energy and incident angle and the validation of the Monte Carlo (MC) simulation of the silicon tracker operation. The calibration setup is described and some preliminary results are presented.
[9]  oai:arXiv.org:1105.4724  [pdf] - 1076835
Vibrational excitation induced by electron beam and cosmic rays in normal and superconductive aluminum bars
Comments: 28 pages, 13 figures
Submitted: 2011-05-24, last modified: 2011-08-02
We report new measurements of the acoustic excitation of an Al5056 superconductive bar when hit by an electron beam, in a previously unexplored temperature range, down to 0.35 K. These data, analyzed together with previous results of the RAP experiment obtained for T > 0.54 K, show a vibrational response enhanced by a factor 4.9 with respect to that measured in the normal state. This enhancement explains the anomalous large signals due to cosmic rays previously detected in the NAUTILUS gravitational wave detector.
[10]  oai:arXiv.org:gr-qc/0009066  [pdf] - 398742
Energetic Cosmic Rays observed by the resonant gravitational wave detector NAUTILUS
Comments: Submitted to Phys. Letters B
Submitted: 2000-09-19
Cosmic ray showers interacting with the resonant mass gravitational wave antenna NAUTILUS have been detected. The experimental results show large signals at a rate much greater than expected. The largest signal corresponds to an energy release in NAUTILUS of 87 TeV. We remark that a resonant mass gravitational wave detector used as particle detector has characteristics different from the usual particle detectors, and it could detect new features of cosmic rays. Among several possibilities, one can invoke unexpected behaviour of superconducting Aluminium as particle detector, producing enhanced signals, the excitation of non-elastic modes with large energy release or anomalies in cosmic rays (for instance, the showers might include exotic particles as nuclearites or Q-balls). Suggestions for explaining these observations are solicited.
[11]  oai:arXiv.org:physics/0001023  [pdf] - 278235
Measurement of mechanical vibrations excited in aluminium resonators by 0.6 GeV electrons
Comments: Tex-Article with epsfile, 34 pages including 13 figures and 5 tables. To be published in Rev. Scient. Instr., May 2000
Submitted: 2000-01-11
We present measurements of mechanical vibrations induced by 0.6 GeV electrons impinging on cylindrical and spherical aluminium resonators. To monitor the amplitude of the resonator's vibrational modes we used piezoelectric ceramic sensors, calibrated by standard accelerometers. Calculations using the thermo-acoustic conversion model, agree well with the experimental data, as demonstrated by the specific variation of the excitation strengths with the absorbed energy, and with the traversing particles' track positions. For the first longitudinal mode of the cylindrical resonator we measured a conversion factor of 7.4 +- 1.4 nm/J, confirming the model value of 10 nm/J. Also, for the spherical resonator, we found the model values for the L=2 and L=1 mode amplitudes to be consistent with our measurement. We thus have confirmed the applicability of the model, and we note that calculations based on the model have shown that next generation resonant mass gravitational wave detectors can only be expected to reach their intended ultra high sensitivity if they will be shielded by an appreciable amount of rock, where a veto detector can reduce the background of remaining impinging cosmic rays effectively.
[12]  oai:arXiv.org:astro-ph/9806391  [pdf] - 101984
Ionization balance for optically thin plasmas: rate coefficients for all atoms and ions of the elements H to Ni
Comments: 7 pages, 10 figures, 2 tables, accepted for publication in A&AS
Submitted: 1998-06-30
We present in this paper new and updated calculations of the ionization equilibrium for all the elements from H to Ni. We collected for these elements all the data available in the literature for the ionization and radiative plus dielectronic recombination rates. In particular, the dielectronic rates have been fitted with a single formula and the related coefficients are tabulated. Our results are compared with previous works.