Normalized to: Mayfield, D.
[1]
oai:arXiv.org:1509.00129 [pdf] - 1530302
First Light Results from the Hermes Spectrograph at the AAT
Sheinis, Andrew;
Anguiano, Borja;
Asplund, Martin;
Bacigalupo, Carlos;
Barden, Sam;
Birchall, Michael;
Bland-Hawthorn, Joss;
Brzeski, Jurek;
Cannon, Russell;
Carollo, Daniela;
Case, Scott;
Casey, Andrew;
Churilov, Vladimir;
Warrick, Couch;
Dean, Robert;
De Silva, Gayandhi;
D'Orazi, Valentina;
Duong, Ly;
Farrell, Tony;
Fiegert, Kristin;
Freeman, Kenneth;
Gabriella, Frost;
Gers, Luke;
Goodwin, Michael;
Gray, Doug;
Green, Andrew;
Heald, Ron;
Heijmans, Jeroen;
Ireland, Michael;
Jones, Damien;
Kafle, Prajwal;
Keller, Stefan;
Klauser, Urs;
Kondrat, Yuriy;
Kos, Janez;
Lawrence, Jon;
Lee, Steve;
Mali, Slavko;
Martell, Sarah;
Mathews, Darren;
Mayfield, Don;
Miziarski, Stan;
Muller, Rolf;
Pai, Naveen;
Patterson, Robert;
Penny, Ed;
Orr, David;
Schlesinger, Katharine;
Sharma, Sanjib;
Shortridge, Keith;
Simpson, Jeffrey;
Smedley, Scott;
Smith, Greg;
Stafford, Darren;
Staszak, Nicholas;
Vuong, Minh;
Waller, Lewis;
de Boer, Elizabeth Wylie;
Xavier, Pascal;
Zheng, Jessica;
Zhelem, Ross;
Zucker, Daniel;
Zwitter, Tomaz
Submitted: 2015-08-31
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a
facility-class optical spectrograph for the Anglo-Australian Telescope (AAT).
It is designed primarily for Galactic Archaeology, the first major attempt to
create a detailed understanding of galaxy formation and evolution by studying
the history of our own galaxy, the Milky Way. The goal of the GALAH survey is
to reconstruct the mass assembly history of the Milky Way through a detailed
chemical abundance study of one million stars. The spectrograph is based at the
AAT and is fed by the existing 2dF robotic fiber positioning system. The
spectrograph uses volume phase holographic gratings to achieve a spectral
resolving power of 28,000 in standard mode and also provides a high-resolution
mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey
requires an SNR greater than 100 for a star brightness of V ?= 14 in an
exposure time of one hour. The total spectral coverage of the four channels is
about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within
the 2-degree field of view. HERMES has been commissioned over three runs,
during bright time in October, November, and December 2013, in parallel with
the beginning of the GALAH pilot survey, which started in November 2013. We
present the first-light results from the commissioning run and the beginning of
the GALAH survey, including performance results such as throughput and
resolution, as well as instrument reliability.
[2]
oai:arXiv.org:astro-ph/0606137 [pdf] - 329112
Performance of AAOmega: the AAT multi-purpose fibre-fed spectrograph
Sharp, R.;
Saunder, W.;
Smith, G.;
Churilov, V.;
Correll, D.;
Dawson, J.;
Farrel, T.;
Frost, G.;
Haynes, R.;
Heald, R.;
Lankshear, A.;
Mayfield, D.;
Waller, L.;
Whittard, D.
Submitted: 2006-06-06
AAOmega is the new spectrograph for the 2dF fibre-positioning system on the
Anglo-Australian Telescope. It is a bench-mounted, double-beamed design, using
volume phase holographic (VPH) gratings and articulating cameras. It is fed by
392 fibres from either of the two 2dF field plates, or by the 512 fibre SPIRAL
integral field unit (IFU) at Cassegrain focus. Wavelength coverage is 370 to
950nm and spectral resolution 1,000-8,000 in multi-Object mode, or 1,500-10,000
in IFU mode. Multi-object mode was commissioned in January 2006 and the IFU
system will be commissioned in June 2006.
The spectrograph is located off the telescope in a thermally isolated room
and the 2dF fibres have been replaced by new 38m broadband fibres. Despite the
increased fibre length, we have achieved a large increase in throughput by use
of VPH gratings, more efficient coatings and new detectors - amounting to a
factor of at least 2 in the red. The number of spectral resolution elements and
the maximum resolution are both more than doubled, and the stability is an
order of magnitude better.
The spectrograph comprises: an f/3.15 Schmidt collimator, incorporating a
dichroic beam-splitter; interchangeable VPH gratings; and articulating red and
blue f/1.3 Schmidt cameras. Pupil size is 190mm, determined by the competing
demands of cost, obstruction losses, and maximum resolution. A full suite of
VPH gratings has been provided to cover resolutions 1,000 to 7,500, and up to
10,000 at particular wavelengths.