Normalized to: Mates, J.
[1]
oai:arXiv.org:1909.01305 [pdf] - 2034407
Microwave multiplexing on the Keck Array
Cukierman, Ari;
Ahmed, Zeeshan;
Henderson, Shawn;
Young, Edward;
Yu, Cyndia;
Barkats, Denis;
Brown, David;
Chaudhuri, Saptarshi;
Cornelison, James;
D'Ewart, John M.;
Dierickx, Marion;
Dober, Bradley J.;
Dusatko, John;
Fatigoni, Sofia;
Filippini, Jeff P.;
Frisch, Josef C.;
Haller, Gunther;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karkare, Kirit S.;
Karpel, Ethan;
Kernasovskiy, Sarah A.;
Kovac, John M.;
Kovacs, Attila;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Smith, Stephen;
Germaine, Tyler St.;
Ullom, Joel N.;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vasquez, Jesus;
Willmert, Justin;
Zeng, Lingzhen;
Ade, P. A. R.;
Amiri, M.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Crumrine, M.;
Duband, L.;
Hall, G.;
Harrison, S.;
Hildebrandt, S. R.;
Hui, H.;
Kang, J.;
Kefeli, S.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Wu, W. L. K.;
Yang, H.;
Yoon, K. W.;
Zhang, C.
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout
system in one of the receivers of the Keck Array, a polarimetry experiment
observing the cosmic microwave background at the South Pole. During the austral
summer of 2018-2019, we replaced the time-division multiplexing readout system
with microwave-multiplexing components including superconducting microwave
resonators coupled to radio-frequency superconducting quantum interference
devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification
between room temperature and the cold stages, and a SLAC Microresonator Radio
Frequency system for the warm electronics. In the range 5-6 GHz, a single
coaxial cable reads out 528 channels. The readout system is coupled to
transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole
phased-array antennas. Observations began in April 2019, and we report here on
an initial characterization of the system performance.
[2]
oai:arXiv.org:1809.03689 [pdf] - 1748092
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator
Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Henderson, Shawn W.;
Ahmed, Zeeshan;
Austermann, Jason;
Becker, Daniel;
Bennett, Douglas A.;
Brown, David;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei Sherry;
D'Ewart, John M.;
Dober, Bradley;
Duff, Shannon M.;
Dusatko, John E.;
Fatigoni, Sofia;
Frisch, Josef C.;
Gard, Jonathon D.;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karpel, Ethan D.;
Kernasovskiy, Sarah S.;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Reintsema, Carl D.;
Smith, Stephen R.;
Ullom, Joel;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vissers, Michael;
Yu, Cyndia
Submitted: 2018-09-11
The next generation of cryogenic CMB and submillimeter cameras under
development require densely instrumented sensor arrays to meet their science
goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of
sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will
require substantial improvements in cold and warm readout techniques. To reduce
the readout cost per sensor and integration complexity, efforts are presently
focused on achieving higher multiplexing density while maintaining readout
noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout
technologies in active development include Microwave Kinetic Inductance Sensors
(MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of
superconducting microwave resonators to densely channelize sub-Kelvin sensors
into the bandwidth of a microwave transmission line. We present advancements in
the development of a new warm readout system for microwave SQUID multiplexing,
the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF
system is unique in its ability to track each tone, minimizing the total RF
power required to read out each resonator, thereby significantly reducing the
linearity requirements on the cold and warm readout. Here, we present
measurements of the readout noise and linearity of the first full SMuRF system,
including a demonstration of closed-loop tone tracking on a 528 channel
cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential
readout solution for several future CMB projects including Simons Observatory,
BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the
platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES
calorimeter arrays.
[3]
oai:arXiv.org:1805.08363 [pdf] - 1709494
SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of
Frequency-Division-Multiplexed Cryogenic Sensors
Kernasovskiy, S. A.;
Kuenstner, S. E.;
Karpel, E.;
Ahmed, Z.;
Van Winkle, D. D.;
Smith, S.;
Dusatko, J.;
Frisch, J. C.;
Chaudhuri, S.;
Cho, H. M.;
Dober, B. J.;
Henderson, S. W.;
Hilton, G. C.;
Hubmayr, J.;
Irwin, K. D.;
Kuo, C. L.;
Li, D.;
Mates, J. A. B.;
Nasr, M.;
Tantawi, S.;
Ullom, J.;
Vale, L.;
Young, B.
Submitted: 2018-05-21
Large arrays of cryogenic sensors for various imaging applications ranging
across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well
as particle detection increasingly rely on superconducting microresonators for
high multiplexing factors. These microresonators take the form of microwave
SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic
Inductance Detectors (MKIDs). In principle, such arrays can be read out with
vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In
this work, we share plans and show initial results for SLAC Microresonator
Radio Frequency (SMuRF) electronics, a next-generation control and readout
system for superconducting microresonators. SMuRF electronics are unique in
their implementation of specialized algorithms for closed-loop tone tracking,
which consists of fast feedback and feedforward to each resonator's excitation
parameters based on transmission measurements. Closed-loop tone tracking
enables improved system linearity, a significant increase in sensor count per
readout line, and the possibility of overcoupled resonator designs for enhanced
dynamic range. Low-bandwidth prototype electronics were used to demonstrate
closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators,
spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve
multi-kHz tracking bandwidth and demonstrate that the noise floor of the
electronics is subdominant to the noise intrinsic in the multiplexer.
[4]
oai:arXiv.org:1710.04326 [pdf] - 1604980
Microwave SQUID Multiplexer demonstration for Cosmic Microwave
Background Imagers
Dober, B.;
Becker, D. T.;
Bennett, D. A.;
Bryan, S. A.;
Duff, S. M.;
Gard, J. D.;
Hays-Wehle, J. P.;
Hilton, G. C.;
Hubmayr, J.;
Mates, J. A. B.;
Reintsema, C. D.;
Vale, L. R.;
Ullom, J. N.
Submitted: 2017-10-11, last modified: 2017-12-15
Key performance characteristics are demonstrated for the microwave SQUID
multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that
have been optimized for cosmic microwave background (CMB) observations. In a
64-channel demonstration, we show that the $\mu$MUX produces a white, input
referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave
probe tone power, which is well below expected fundamental detector and photon
noise sources for a ground-based CMB-optimized bolometer. Operated with
negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the
TES-coupled channels biased at 65% of the sensor normal resistance. This noise
level is consistent with that predicted from bolometer thermal fluctuation
(i.e., phonon) noise. Furthermore, the power spectral density exhibits a white
spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on
large angular scales that constrain the physics of inflation. Additionally, we
report cross-talk measurements that indicate a level below 0.3%, which is less
than the level of cross-talk from multiplexed readout systems in deployed CMB
imagers. These measurements demonstrate the $\mu$MUX as a viable readout
technique for future CMB imaging instruments.
[5]
oai:arXiv.org:1310.7287 [pdf] - 1180273
High-resolution gamma-ray spectroscopy with a microwave-multiplexed
transition-edge sensor array
Noroozian, Omid;
Mates, John A. B.;
Bennett, Douglas A.;
Brevik, Justus A.;
Fowler, Joseph W.;
Gao, Jiansong;
Hilton, Gene C.;
Horansky, Robert D.;
Irwin, Kent D.;
Kang, Zhao;
Schmidt, Daniel R.;
Vale, Leila R.;
Ullom, Joel N.
Submitted: 2013-10-27
We demonstrate very high resolution photon spectroscopy with a
microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured
a $^{153}$Gd photon source and achieved an energy resolution of 63 eV
full-width-at-half-maximum at 97 keV and an equivalent readout system noise of
86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of
superconducting microwave resonators coupled to radio-frequency
superconducting-quantum-interference-devices (SQUID) and transduces changes in
input current to changes in phase of a microwave signal. We use flux-ramp
modulation to linearize the response and evade low-frequency noise. This
demonstration establishes one path for the readout of cryogenic X-ray and
gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving
powers $R=\lambda/\Delta\lambda > 10^3$.
[6]
oai:arXiv.org:1008.5106 [pdf] - 1034561
Time-division SQUID multiplexers with reduced sensitivity to external
magnetic fields
Submitted: 2010-08-30
Time-division SQUID multiplexers are used in many applications that require
exquisite control of systematic error. One potential source of systematic error
is the pickup of external magnetic fields in the multiplexer. We present
measurements of the field sensitivity figure of merit, effective area, for both
the first stage and second stage SQUID amplifiers in three NIST SQUID
multiplexer designs. These designs include a new variety with improved
gradiometry that significantly reduces the effective area of both the first and
second stage SQUID amplifiers.