sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Matalon, A.

Normalized to: Matalon, A.

5 article(s) in total. 75 co-authors, from 1 to 5 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1907.12628  [pdf] - 2076614
Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB
Comments: 6 pages, 4 figures
Submitted: 2019-07-29, last modified: 2020-04-08
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with masses in the range $1.2$-$30$ eV$c^{-2}$.
[2]  oai:arXiv.org:1708.01379  [pdf] - 1586763
The Fluorescence detector Array of Single-pixel Telescopes: Contributions to the 35th International Cosmic Ray Conference (ICRC 2017)
Comments: 2 proceedings of FAST will be appeared in PoS (ICRC2017)
Submitted: 2017-08-04
Contributions of the Fluorescence detector Array of Single-pixel Telescopes (FAST) to the 35th International Cosmic Ray Conference, 12-20 July 2017, Busan, Korea
[3]  oai:arXiv.org:1706.06053  [pdf] - 1584871
Measurement of low energy ionization signals from Compton scattering in a CCD dark matter detector
Comments: 8 pages, 9 figures
Submitted: 2017-06-19
An important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental $\gamma$ rays. We report detailed measurements of low-energy spectra from Compton scattering of $\gamma$ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by $\gamma$ rays from $^{57}$Co and $^{241}$Am radioactive sources are measured between 60 eV and 4 keV. The observed spectra agree qualitatively with theoretical predictions, and characteristic spectral features associated with the atomic structure of the silicon target are accurately measured for the first time. A theoretically-motivated parametrization of the data that describes the Compton spectrum at low energies for any incident $\gamma$-ray flux is derived. The result is directly applicable to background estimations for low-mass dark matter direct-detection experiments based on silicon detectors, in particular for the DAMIC experiment down to its current energy threshold.
[4]  oai:arXiv.org:1611.03066  [pdf] - 1561044
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
Comments: 5 pages, 5 figures
Submitted: 2016-11-09, last modified: 2017-04-11
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $\kappa$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.
[5]  oai:arXiv.org:1504.00692  [pdf] - 1311063
Detection of ultra-high energy cosmic ray showers with a single-pixel fluorescence telescope
Comments: Accepted for publication in Astroparticle Physics
Submitted: 2015-04-02, last modified: 2015-10-15
We present a concept for large-area, low-cost detection of ultra-high energy cosmic rays (UHECRs) with a Fluorescence detector Array of Single-pixel Telescopes (FAST), addressing the requirements for the next generation of UHECR experiments. In the FAST design, a large field of view is covered by a few pixels at the focal plane of a mirror or Fresnel lens. We report first results of a FAST prototype installed at the Telescope Array site, consisting of a single 200 mm photomultiplier tube at the focal plane of a 1 m$^2$ Fresnel lens system taken from the prototype of the JEM-EUSO experiment. The FAST prototype took data for 19 nights, demonstrating remarkable operational stability. We detected laser shots at distances of several kilometres as well as 16 highly significant UHECR shower candidates.