Normalized to: Massai, M.
[1]
oai:arXiv.org:1309.6995 [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo;
Barcons, Xavier;
Bellazzini, Ronaldo;
Braga, João;
Costa, Enrico;
Fraser, George W.;
Gburek, Szymon;
Huovelin, Juhani;
Matt, Giorgio;
Pearce, Mark;
Poutanen, Juri;
Reglero, Victor;
Santangelo, Andrea;
Sunyaev, Rashid A.;
Tagliaferri, Gianpiero;
Weisskopf, Martin;
Aloisio, Roberto;
Amato, Elena;
Attiná, Primo;
Axelsson, Magnus;
Baldini, Luca;
Basso, Stefano;
Bianchi, Stefano;
Blasi, Pasquale;
Bregeon, Johan;
Brez, Alessandro;
Bucciantini, Niccoló;
Burderi, Luciano;
Burwitz, Vadim;
Casella, Piergiorgio;
Churazov, Eugene;
Civitani, Marta;
Covino, Stefano;
da Silva, Rui Miguel Curado;
Cusumano, Giancarlo;
Dadina, Mauro;
D'Amico, Flavio;
De Rosa, Alessandra;
Di Cosimo, Sergio;
Di Persio, Giuseppe;
Di Salvo, Tiziana;
Dovciak, Michal;
Elsner, Ronald;
Eyles, Chris J.;
Fabian, Andrew C.;
Fabiani, Sergio;
Feng, Hua;
Giarrusso, Salvatore;
Goosmann, René W.;
Grandi, Paola;
Grosso, Nicolas;
Israel, Gianluca;
Jackson, Miranda;
Kaaret, Philip;
Karas, Vladimir;
Kuss, Michael;
Lai, Dong;
La Rosa, Giovanni;
Larsson, Josefin;
Larsson, Stefan;
Latronico, Luca;
Maggio, Antonio;
Maia, Jorge;
Marin, Frédéric;
Massai, Marco Maria;
Mineo, Teresa;
Minuti, Massimo;
Moretti, Elena;
Muleri, Fabio;
O'Dell, Stephen L.;
Pareschi, Giovanni;
Peres, Giovanni;
Pesce, Melissa;
Petrucci, Pierre-Olivier;
Pinchera, Michele;
Porquet, Delphine;
Ramsey, Brian;
Rea, Nanda;
Reale, Fabio;
Rodrigo, Juana Maria;
Różańska, Agata;
Rubini, Alda;
Rudawy, Pawel;
Ryde, Felix;
Salvati, Marco;
Júnior, Valdivino Alexandre de Santiago;
Sazonov, Sergey;
Sgró, Carmelo;
Silver, Eric;
Spandre, Gloria;
Spiga, Daniele;
Stella, Luigi;
Tamagawa, Toru;
Tamborra, Francesco;
Tavecchio, Fabrizio;
Dias, Teresa Teixeira;
van Adelsberg, Matthew;
Wu, Kinwah;
Zane, Silvia
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and
temporal variability measurements and to imaging, allows a wealth of physical
phenomena in astrophysics to be studied. X-ray polarimetry investigates the
acceleration process, for example, including those typical of magnetic
reconnection in solar flares, but also emission in the strong magnetic fields
of neutron stars and white dwarfs. It detects scattering in asymmetric
structures such as accretion disks and columns, and in the so-called molecular
torus and ionization cones. In addition, it allows fundamental physics in
regimes of gravity and of magnetic field intensity not accessible to
experiments on the Earth to be probed. Finally, models that describe
fundamental interactions (e.g. quantum gravity and the extension of the
Standard Model) can be tested. We describe in this paper the X-ray Imaging
Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a
small mission with a launch in 2017 but not selected. XIPE is composed of two
out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD)
filled with a He-DME mixture at their focus and two additional GPDs filled with
pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 %
at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half
Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X
optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with
Malindi as down-link station and of a Mission Operation Center (MOC) at INPE
(Brazil).
[2]
oai:arXiv.org:physics/0703176 [pdf] - 119212
Imaging with the invisible light
Bellazzini, R.;
Spandre, G.;
Brez, A.;
Minuti, M.;
Baldini, L.;
Latronico, L.;
Massai, M. M.;
Omodei, N.;
Pesce-Rollins, M.;
Sgró, C;
Razzano, M.;
Pinchera, M.;
Bregeon, J.;
Kuss, M.;
Braem, A.
Submitted: 2007-03-19, last modified: 2007-03-20
We describe a UV photo-detector with single photon(electron) counting and
imaging capability. It is based on a CsI photocathode, a GEM charge multiplier
and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron
pitch. The single photoelectron produced by the absorption of a UV photon is
drifted to and multiplied inside a single GEM hole. The coordinates of the GEM
avalanche are reconstructed with high accuracy (4 micron rms) by the pixel
chip. As a result the map of the GEM holes, arranged on a triangular pattern at
50micron pitch, is finely imaged.
[3]
oai:arXiv.org:astro-ph/0611512 [pdf] - 86898
A Sealed Gas Pixel Detector for X-ray Astronomy
Bellazzini, R.;
Spandre, G.;
Minuti, M.;
Baldini, L.;
Brez, A.;
Latronico, L.;
Omodei, N.;
Razzano, M.;
Massai, M. M.;
Pinchera, M.;
Pesce-Rollins, M.;
Sgro, C.;
Costa, E.;
Soffitta, P.;
Sipila, H.;
Lempinen, E.
Submitted: 2006-11-16, last modified: 2006-11-20
We report on the results of a new, sealed, Gas Pixel Detector. The very
compact design and the absence of the gas flow system, make this detector
substantially ready for use as focal plane detector for future X-ray space
telescopes. The instrument brings high sensitivity to X-ray polarimetry, which
is the last unexplored field of X-ray astronomy. It derives the polarization
information from the track of the photoelectrons that are imaged by a high gain
(>1000), fine pitch GEM that matches the pitch of a pixel ASIC which is the
collecting anode of the GPD (105k, 50 micron wide, hexagonal cells). The device
is able to simultaneously perform good imaging (50-60 micron), moderate
spectroscopy (~15% at 6 keV) as well as fast, high rate timing in the 1-10keV
range. Moreover, being truly 2D, it is non dispersive and does not require any
rotation. The great improvement of sensitivity, at least two orders of
magnitude with respect to traditional polarimeters (based on Bragg crystals or
Thomson scattering), will allow the direct exploration of the most dramatic
objects of the X-ray sky. At the focus of the large mirror area of the XEUS
telescope it will be decisive in reaching many of the scientific goals of the
mission. With integration times of the order of one day, polarimetry of Active
Galactic Nuclei at the per cent level will be possible, making for a real
breakthrough in high energy astrophysics.
[4]
oai:arXiv.org:astro-ph/0609573 [pdf] - 85165
An X-ray polarimeter for hard X-ray optics
Muleri, Fabio;
Bellazzini, Ronaldo;
Costa, Enrico;
Soffitta, Paolo;
Lazzarotto, Francesco;
Feroci, Marco;
Pacciani, Luigi;
Rubini, Alda;
Morelli, Ennio;
Baldini, Luca;
Bitti, Francesco;
Brez, Alessandro;
Cavalca, Francesco;
Latronico, Luca;
Massai, Marco Maria;
Omodei, Nicola;
Pinchera, Michele;
Sgro', Carmelo;
Spandre, Gloria;
Matt, Giorgio;
Perola, Giuseppe Cesare;
Citterio, Oberto;
Pareschi, Giovanni;
Cotroneo, Vincenzo;
Spiga, Daniele;
Canestrari, Rodolfo
Submitted: 2006-09-20
Development of multi-layer optics makes feasible the use of X-ray telescope
at energy up to 60-80 keV: in this paper we discuss the extension of
photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy
X-rays. We calculated the sensitivity with Neon and Argon based mixtures at
high pressure with thick absorption gap: placing the MPGC at focus of a next
generation multi-layer optics, galatic and extragalactic X-ray polarimetry can
be done up till 30 keV.
[5]
oai:arXiv.org:astro-ph/0609576 [pdf] - 85168
POLARIX: a small mission of x-ray polarimetry
Costa, Enrico;
Bellazzini, Ronaldo;
Soffitta, Paolo;
Muleri, Fabio;
Feroci, Marco;
Frutti, Massimo;
Mastropietro, Marcello;
Pacciani, Luigi;
Rubini, Alda;
Morelli, Ennio;
Baldini, Luca;
Bitti, Francesco;
Brez, Alessandro;
Cavalca, Francesco;
Latronico, Luca;
Massai, Marco Maria;
Omodei, Nicola;
Pinchera, Michele;
Sgro', Carmelo;
Spandre, Gloria;
Matt, Giorgio;
Perola, Giuseppe Cesare;
Chincarini, Guido;
Citterio, Oberto;
Tagliaferri, Gianpiero;
Pareschi, Giovanni;
Cotroneo, Vincenzo
Submitted: 2006-09-20
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber
in the focus of a telescope. It requires large area optics for most important
scientific targets. But since the technique is additive a dedicated mission
with a cluster of small telescopes can perform many important measurements and
bridge the 40 year gap between OSO-8 data and future big telescopes such as
XEUS. POLARIX has been conceived as such a pathfinder. It is a Small Satellite
based on the optics of JET-X. Two telescopes are available in flight
configuration and three more can be easily produced starting from the available
superpolished mandrels. We show the capabilities of such a cluster of
telescopes each equipped with a focal plane photoelectric polarimeter and
discuss a few alternative solutions.
[6]
oai:arXiv.org:astro-ph/0609571 [pdf] - 85163
A photoelectric polarimeter for XEUS: a new window in x-ray sky
Bellazzini, Ronaldo;
Baldini, Luca;
Bitti, Francesco;
Brez, Alessandro;
Cavalca, Francesco;
Latronico, Luca;
Massai, Marco Maria;
Omodei, Nicola;
Pinchera, Michele;
Sgro', Carmelo;
Spandre, Gloria;
Costa, Enrico;
Soffitta, Paolo;
Di Persio, Giuseppe;
Feroci, Marco;
Muleri, Fabio;
Pacciani, Luigi;
Rubini, Alda;
Morelli, Ennio;
Matt, Giorgio;
Perola, Giuseppe Cesare
Submitted: 2006-09-20
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of
Optical Astronomy in terms of collecting areas. It will be based on two
satellites, locked on a formation flight, one with the optics, one with the
focal plane. The present design of the focal plane foresees, as an auxiliary
instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We
show how such a device is capable to solve open problems on many classes of
High Energy Astrophysics objects and to use X-ray sources as a laboratory for a
substantial progress on Fundamental Physics.
[7]
oai:arXiv.org:physics/0604114 [pdf] - 119160
Direct reading of charge multipliers with a self-triggering CMOS analog
chip with 105k pixels at 50 micron pitch
Bellazzini, R.;
Spandre, G.;
Minuti, M.;
Baldini, L.;
Brez, A.;
Cavalca, F.;
Latronico, L.;
Omodei, N.;
Massai, M. M.;
Sgro, C.;
Costa, E.;
Krummenacher, P. Soffitta F.;
DeOliveira, R.
Submitted: 2006-04-14, last modified: 2006-04-26
We report on a large active area (15x15mm2), high channel density (470
pixels/mm2), self-triggering CMOS analog chip that we have developed as
pixelized charge collecting electrode of a Micropattern Gas Detector. This
device, which represents a big step forward both in terms of size and
performance, is the last version of three generations of custom ASICs of
increasing complexity. The CMOS pixel array has the top metal layer patterned
in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is
directly connected to the underneath full electronics chain which has been
realized in the remaining five metal and two poly-silicon layers of a 0.18
micron VLSI technology. The chip has customizable self-triggering capability
and includes a signal pre-processing function for the automatic localization of
the event coordinates. In this way it is possible to reduce significantly the
readout time and the data volume by limiting the signal output only to those
pixels belonging to the region of interest. The very small pixel area and the
use of a deep sub-micron CMOS technology has brought the noise down to 50
electrons ENC. Results from in depth tests of this device when coupled to a
fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are
presented. The matching of readout and gas amplification pitch allows to get
optimal results. The application of this detector for Astronomical X-Ray
Polarimetry is discussed. The experimental detector response to polarized and
unpolarized X-ray radiation when working with two gas mixtures and two
different photon energies is shown. Results from a full MonteCarlo simulation
for several galactic and extragalactic atronomical sources are also reported.
[8]
oai:arXiv.org:astro-ph/0603399 [pdf] - 80608
Opening a New Window to Fundamental Physics and Astrophysics: X-ray
Polarimetry
Costa, E.;
Bellazzini, R.;
Soffitta, P.;
di Persio, G.;
Feroci, M.;
Morelli, E.;
Muleri, F.;
Pacciani, L.;
Rubini, A.;
Baldini, L.;
Bitti, F.;
Brez, A.;
Cavalca, F.;
Latronico, L.;
Massai, M. M.;
Omodei, N.;
Sgro', C.;
Spandre, G.;
Matt, G.;
Perola, G. C.;
Santangelo, A.;
Celotti, A.;
Barret, D.;
Vilhu, O.;
Piro, L.;
Fraser, G.;
Courvoisier, T. J. -L.;
Barcons, X.
Submitted: 2006-03-15
An extensive theoretical literature predicts that X-ray Polarimetry can
directly determine relevant physical and geometrical parameters of
astrophysical sources, and discriminate between models further than allowed by
spectral and timing data only. X-ray Polarimetry can also provide tests of
Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New
Generation X-ray telescope could open this new window in the High Energy Sky.
[9]
oai:arXiv.org:astro-ph/0512242 [pdf] - 78442
Gas Pixel Detectors for X-ray Polarimetry applications
Bellazzini, R.;
Angelini, F.;
Baldini, L.;
Bitti, F.;
Brez, A.;
Cavalca, F.;
Del Prete, M.;
Kuss, M.;
Latronico, L.;
Omodei, N.;
Pinchera, M.;
Massai, M. M.;
Minuti, M.;
Razzano, M.;
Sgro, C.;
Spandre, G.;
Tenze, A.;
Costa, E.;
Soffitta, P.
Submitted: 2005-12-09, last modified: 2006-02-08
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector
(GPD), in which a complete integration between the gas amplification structure
and the read-out electronics has been reached. An Application-Specific
Integrated Circuit (ASIC) built in deep sub-micron technology has been
developed to realize a monolithic device that is, at the same time, the
pixelized charge collecting electrode and the amplifying, shaping and charge
measuring front-end electronics. The CMOS chip has the top metal layer
patterned in a matrix of 80 micron pitch hexagonal pixels, each of them
directly connected to the underneath electronics chain which has been realized
in the remaining five layers of the 0.35 micron VLSI technology. Results from
tests of a first prototype of such detector with 2k pixels and a full scale
version with 22k pixels are presented. The application of this device for
Astronomical X-Ray Polarimetry is discussed. The experimental detector response
to polarized and unpolarized X-ray radiation is shown. Results from a full
MonteCarlo simulation for two astronomical sources, the Crab Nebula and the
Hercules X1, are also reported.
[10]
oai:arXiv.org:physics/0403019 [pdf] - 1238072
Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting
anode
Bellazzini, R.;
Angelini, F.;
Baldini, L.;
Bitti, F.;
Brez, A.;
Latronico, L.;
Massai, M. M.;
Minuti, M.;
Omodei, N.;
Razzano, M.;
Sgro, C.;
Spandre, G.;
Costa, E.;
Soffitta, P.
Submitted: 2004-03-01
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron
and the number of pixels is large (above 1000) it is virtually impossible to
use the conventional PCB read-out approach to bring the signal charge from the
individual pixel to the external electronics chain. For this reason a custom
CMOS array of 2101 active pixels with 80 micron pitch, directly used as the
charge collecting anode of a GEM amplifying structure, has been developed and
built. Each charge collecting pad, hexagonally shaped, realized using the top
metal layer of a deep submicron VLSI technology is individually connected to a
full electronics chain (pre-amplifier, shaping-amplifier, sample and hold,
multiplexer) which is built immediately below it by using the remaining five
active layers. The GEM and the drift electrode window are assembled directly
over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern
Gas Detector. With this approach, for the first time, gas detectors have
reached the level of integration and resolution typical of solid state pixel
detectors. Results from the first tests of this new read-out concept are
presented. An Astronomical X-Ray Polarimetry application is also discussed.