sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mas, Marion

Normalized to: Mas, M.

3 article(s) in total. 5 co-authors, from 1 to 3 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1710.03520  [pdf] - 1589521
Experimental parametric study of the self-coherent camera
Comments: Space Telescopes and Instrumentation 2012: Optical, Infrared, and Millimeter Wave. Proceedings of the SPIE, Volume 8442, article id. 844250, 10 pp. (2012)
Submitted: 2017-10-10
Direct imaging of exoplanets requires the detection of very faint objects orbiting close to very bright stars. In this context, the SPICES mission was proposed to the European Space Agency for planet characterization at visible wavelength. SPICES is a 1.5m space telescope which uses a coronagraph to strongly attenuate the central source. However, small optical aberrations, which appear even in space telescopes, dramatically decrease coronagraph performance. To reduce these aberrations, we want to estimate, directly on the coronagraphic image, the electric field, and, with the help of a deformable mirror, correct the wavefront upstream of the coronagraph. We propose an instrument, the Self-Coherent Camera (SCC) for this purpose. By adding a small "reference hole" into the Lyot stop, located after the coronagraph, we can produce interferences in the focal plane, using the coherence of the stellar light. We developed algorithms to decode the information contained in these Fizeau fringes and retrieve an estimation of the field in the focal plane. After briefly recalling the SCC principle, we will present the results of a study, based on both experiment and numerical simulation, analyzing the impact of the size of the reference hole.
[2]  oai:arXiv.org:1306.5561  [pdf] - 1172236
Estimation and correction of wavefront aberrations using the self-coherent camera: laboratory results
Comments: 14 pages, 16 figures, accepted in Astronomy and Astrophysics, 2013, 2nd version after language-editor corrections
Submitted: 2013-06-24, last modified: 2013-09-09
Direct imaging of exoplanets requires very high contrast levels, which are obtained using coronagraphs. But residual quasi-static aberrations create speckles in the focal plane downstream of the coronagraph which mask the planet. This problem appears in ground-based instruments as well as in space-based telescopes. An active correction of these wavefront errors using a deformable mirror upstream of the coronagraph is mandatory, but conventional adaptive optics are limited by differential path aberrations. Dedicated techniques have to be implemented to measure phase and amplitude errors directly in the science focal plane. First, we propose a method for estimating phase and amplitude aberrations upstream of a coronagraph from the speckle complex field in the downstream focal plane. Then, we present the self-coherent camera, which uses the coherence of light to spatially encode the focal plane speckles and retrieve the associated complex field. This enable us to estimate and compensate in a closed loop for the aberrations upstream of the coronagraph. We conducted numerical simulations as well as laboratory tests using a four-quadrant phase mask and a 32x32 actuator deformable mirror. We demonstrated in the laboratory our capability to achieve a stable closed loop and compensate for phase and amplitude quasi-static aberrations. We determined the best-suited parameter values to implement our technique. Contrasts better than 10-6 between 2 and 12 lambda/D and even 3.10-7 (RMS) between 7 and 11 lambda/D were reached in the focal plane. It seems that the contrast level is mainly limited by amplitude defects created by the surface of the deformable mirror and by the dynamic of the detector. These results are promising for a future application to a dedicated space mission for exoplanet characterization. A number of possible improvements have been identified.
[3]  oai:arXiv.org:0911.2465  [pdf] - 1018344
Self-coherent camera as a focal plane wavefront sensor: simulations
Comments: 15 pages, 14 figures, accepted in A&A (here is the final version)
Submitted: 2009-11-12
Direct detection of exoplanets requires high dynamic range imaging. Coronagraphs could be the solution, but their performance in space is limited by wavefront errors (manufacturing errors on optics, temperature variations, etc.), which create quasi-static stellar speckles in the final image. Several solutions have been suggested for tackling this speckle noise. Differential imaging techniques substract a reference image to the coronagraphic residue in a post-processing imaging. Other techniques attempt to actively correct wavefront errors using a deformable mirror. In that case, wavefront aberrations have to be measured in the science image to extremely high accuracy. We propose the self-coherent camera sequentially used as a focal-plane wavefront sensor for active correction and differential imaging. For both uses, stellar speckles are spatially encoded in the science image so that differential aberrations are strongly minimized. The encoding is based on the principle of light incoherence between the hosting star and its environment. In this paper, we first discuss one intrinsic limitation of deformable mirrors. Then, several parameters of the self-coherent camera are studied in detail. We also propose an easy and robust design to associate the self-coherent camera with a coronagraph that uses a Lyot stop. Finally, we discuss the case of the association with a four-quadrant phase mask and numerically demonstrate that such a device enables the detection of Earth-like planets under realistic conditions. The parametric study of the technique lets us believe it can be implemented quite easily in future instruments dedicated to direct imaging of exoplanets.