Normalized to: Martinez-Galarza, J.
[1]
oai:arXiv.org:1508.03070 [pdf] - 1264215
The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The
Medium Resolution Spectrometer
Wells, Martyn;
Pel, J. -W.;
Glasse, Alistair;
Wright, G. S.;
Aitink-Kroes, Gabby;
Azzollini, Ruyman;
Beard, Steven;
Brandl, B. R.;
Gallie, Angus;
Geers, V. C.;
Glauser, A. M.;
Hastings, Peter;
Henning, Th.;
Jager, Rieks;
Justtanont, K.;
Kruizinga, Bob;
Lahuis, Fred;
Lee, David;
Martinez-Delgado, I.;
Martinez-Galarza, J. R.;
Meijers, M.;
Morrison, Jane E.;
Mueller, Friedrich;
Nakos, Thodori;
O'Sullivan, Brian;
Oudenhuysen, Ad;
Parr-Burman, P.;
Pauwels, Evert;
Rohloff, R. -R.;
Schmalzl, Eva;
Sykes, Jon;
Thelen, M. P.;
van Dishoeck, E. F.;
Vandenbussche, Bart;
Venema, Lars B.;
Visser, Huib;
Waters, L. B. F. M.;
Wright, David
Submitted: 2015-08-12
We describe the design and performance of the Medium Resolution Spectrometer
(MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral
channels in a compact opto-mechanical layout that generates spectral images
over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral
resolving powers ranging from 1,300 to 3,700. Each channel includes an
all-reflective integral field unit (IFU): an 'image slicer' that reformats the
input field for presentation to a grating spectrometer. Two 1024 X 1024 focal
plane arrays record the output spectral images with an instantaneous spectral
coverage of approximately one third of the full wavelength range of each
channel. The full 5 to 28.5 micron spectrum is then obtained by making three
exposures using gratings and pass-band-determining filters that are selected
using just two three-position mechanisms. The expected on-orbit optical
performance is presented, based on testing of the MIRI Flight Model and
including spectral and spatial coverage and resolution. The point spread
function of the reconstructed images is shown to be diffraction limited and the
optical transmission is shown to be consistent with the design expectations.
[2]
oai:arXiv.org:1507.02966 [pdf] - 1277097
A WISE Census of Young Stellar Objects in Perseus OB2 Association
Submitted: 2015-07-10
We have performed a WISE (Wide-Field Infrared Survey Explorer) based study to
identify and characterize young stellar objects (YSOs) in 12x12 degree Perseus
OB2 association. Spectral energy distribution (SED) slope in range of 3.4-12
micron and a 5sigma selection criteria were used to select our initial sample.
Further manual inspection reduced our final catalog to 156 known and 119 YSO
candidate. The spatial distribution of newly found YSOs all over the field
shows an older generation of star formation which most of its massive members
have evolved into main sequence stars. In contrast, the majority of younger
members lie within the Perseus molecular cloud and currently active star
forming clusters such as NGC1333 and IC348. We also identified additional 66
point sources which passed YSO selection criteria but are likely AGB stars.
However their spatial distribution suggests that they may contain a fraction of
the YSOs. Comparing our results with the commonly used color-color selections,
we found that while color selection method fails in picking up bright but
evolved weak disks, our SED fitting method can identify such sources, including
transitional disks. In addition we have less contamination with background
sources such as galaxies, but in a price of loosing fainter (Jmag > 12) YSOs.
Finally we employed a Bayesian Monte Carlo SED fitting method to determine the
characteristics of each YSO candidate. Distribution of SED slopes and model
driven age and mass confirms separated YSO populations with suggested three age
groups of younger than 1 Myr old, 1-5 Myr old, and older than 5 Myrs which
agrees with the age of Per OB2 association and currently star forming sites
within the cloud.
[3]
oai:arXiv.org:1006.5243 [pdf] - 1033350
Wavelength calibration of the JWST-MIRI medium resolution spectrometer
Submitted: 2010-06-27
We present the wavelength and spectral resolution characterisation of the
Integral Field Unit (IFU) Medium Resolution Spectrometer for the Mid-InfraRed
Instrument (MIRI), to fly onboard the James Webb Space Telescope in 2014. We
use data collected using the Verification Model of the instrument and develop
an empirical method to calibrate properties such as wavelength range and
resolving power in a portion of the spectrometer's full spectral range (5-28
microns). We test our results against optical models to verify the system
requirements and combine them with a study of the fringing pattern in the
instrument's detector to provide a more accurate calibration. We show that
MIRI's IFU spectrometer will be able to produce spectra with a resolving power
above R=2800 in the wavelength range 6.46-7.70 microns, and that the unresolved
spectral lines are well fitted by a Gaussian profile.