Submitted: 2011-01-10
We report on the construction, tests, calibrations and commissioning of an
Optical Readout Time Projection Chamber (O-TPC) detector operating with a
CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure
the cross sections of several key nuclear reactions involved in stellar
evolution. In particular, a study of the rate of formation of oxygen and carbon
during the process of helium burning will be performed by exposing the chamber
gas to intense nearly mono-energetic gamma-ray beams at the High Intensity
Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of
30x30x21 cm^3. Ionization electrons drift towards a double parallel grid
avalanche multiplier, yielding charge multiplication and light emission.
Avalanche induced photons from N2 emission are collected, intensified and
recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional
track images. The event's time projection (third coordinate) and the deposited
energy are recorded by photomultipliers and by the TPC charge-signal,
respectively. A dedicated VME-based data acquisition system and associated data
analysis tools were developed to record and analyze these data. The O-TPC has
been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd
source placed within its volume with a measured energy resolution of 3.0%.
Tracks of alpha and 12C particles from the dissociation of 16O and of three
alpha-particles from the dissociation of 12C have been measured during initial
in-beam test experiments performed at the HIgS facility at Duke University. The
full detection system and its performance are described and the results of the
preliminary in-beam test experiments are reported.