sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Marino, M. G.

Normalized to: Marino, M.

8 article(s) in total. 101 co-authors, from 1 to 7 common article(s). Median position in authors list is 11,5.

[1]  oai:arXiv.org:1401.6234  [pdf] - 931856
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of CoGeNT Data
Comments: 10 pages, 11 figures. Submitted to Phys. Rev. D
Submitted: 2014-01-23, last modified: 2015-02-05
CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction rates for given observable nuclear recoil energies during differing periods of the Earth's annual orbit around the Sun. Cosmogenic and primordial radioactivity backgrounds are characterized by their energy signatures and in some cases decay half-lives. A third parameterizing variable -- pulse rise-time -- is added to the likelihood analysis to characterize slow rising pulses described in prior analyses. The contribution to each event category is analyzed for various dark matter signal hypotheses including a dark matter standard halo model and a case with free oscillation parameters (i.e., amplitude, period, and phase). The best-fit dark matter signal is in close proximity to previously reported results. We find that the significance of the extracted dark matter signal remains well below evidentiary at 1.7 $\sigma$.
[2]  oai:arXiv.org:1403.0475  [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana low-background BEGe detector at Kimballton (MALBEK)
Comments: This paper has been withdrawn by the authors. Recent results we were not aware of should be taken into account
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ model axions to electrons. The prospects for the sensitivity of the Majorana Demonstrator array of point-contact germanium detectors to solar axions are discussed in the context of the model-independent annual modulation due to the seasonal variation of the earth-sun distance.
[3]  oai:arXiv.org:1401.3295  [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
Comments: Three datasets and note on usage included as ancillary files
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.
[4]  oai:arXiv.org:1208.5737  [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
Comments: 20 pages, 31 figures. Several figures have been added, including an updated allowed region (both 90% and 99% confidence level contours) based on this analysis. There is also the addition of a Pb-210 background estimate
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data, or the previously observed temporal variation in the event rate. Also reported on for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results
[5]  oai:arXiv.org:1106.0650  [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector
Comments: Published version, slightly expanded discussion of ROI uncertainties, one reference added
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ~2.8 sigma, limited by the short exposure.
[6]  oai:arXiv.org:1002.4703  [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
Comments: 4 pages, 4 figures. v2: submitted version. Minimal changes in wording, one reference added
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.
[7]  oai:arXiv.org:0903.5068  [pdf] - 22863
Comments on arXiv:0902.4693v1 "Search for Axions with the CDMS Experiment"
Comments:
Submitted: 2009-03-29
We offer a few remarks that should help clarify the relative sensitivity of CoGeNT, CDMS and DAMA to dark pseudoscalars. An alternative dark matter origin for the DAMA modulation is briefly mentioned within this context.
[8]  oai:arXiv.org:0807.0879  [pdf] - 14236
Experimental constraints on a dark matter origin for the DAMA annual modulation effect
Comments: v4: introduces recent results from arXiv:0807.3279 and arXiv:0807.2926. Sensitivity to pseudoscalars is revised in light of the first. Discussion on the subject added
Submitted: 2008-07-05, last modified: 2008-07-31
A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.