Normalized to: Mansanet, C.
[1]
oai:arXiv.org:1905.09060 [pdf] - 1887968
Temperature stability in the sub-milliHertz band with LISA Pathfinder
Armano, M.;
Audley, H.;
Baird, J.;
Binetruy, P.;
Born, M.;
Bortoluzzi, D.;
Castelli, E.;
Cavalleri, A.;
Cesarini, A.;
Cruise, A. M.;
Danzmann, K.;
Silva, M. de Deus;
Diepholz, I.;
Dixon, G.;
Dolesi, R.;
Ferraioli, L.;
Ferroni, V.;
Fitzsimons, E. D.;
Freschi, M.;
Gesa, L.;
Gibert, F.;
Giardini, D.;
Giusteri, R.;
Grimani, C.;
Grzymisch, J.;
Harrison, I.;
Heinzel, G.;
Hewitson, M.;
Hollington, D.;
Hoyland, D.;
Hueller, M.;
Inchauspé, H.;
Jennrich, O.;
Jetzer, P.;
Karnesis, N.;
Kaune, B.;
Korsakova, N.;
Killow, C. J.;
Lobo, J. A.;
Lloro, I.;
Liu, L.;
López-Zaragoza, J. P.;
Maarschalkerweerd, R.;
Mance, D.;
Mansanet, C.;
Martín, V.;
Martin-Polo, L.;
Martino, J.;
Martin-Porqueras, F.;
Mateos, I.;
McNamara, P. W.;
Mendes, J.;
Mendes, L.;
Meshksar, N.;
Nofrarias, M.;
Paczkowski, S.;
Perreur-Lloyd, M.;
Petiteau, A.;
Pivato, P.;
Plagnol, E.;
Ramos-Castro, J.;
Reiche, J.;
Robertson, D. I.;
Rivas, F.;
Russano, G.;
Sanjuán, J.;
Slutsky, J.;
Sopuerta, C. F.;
Sumner, T.;
Texier, D.;
Thorpe, J. I.;
Trenkel, C.;
Vetrugno, D.;
Vitale, S.;
Wanner, G.;
Ward, H.;
Wass, P. J.;
Wealthy, D.;
Weber, W. J.;
Wissel, L.;
Wittchen, A.;
Zweifel, P.
Submitted: 2019-05-22
LISA Pathfinder (LPF) was a technology pioneering mission designed to test
key technologies required for gravitational wave detection in space. In the low
frequency regime (milli-Hertz and below), where space-based gravitational wave
observatories will operate, temperature fluctuations play a crucial role since
they can couple into the interferometric measurement and the test masses'
free-fall accuracy in many ways. A dedicated temperature measurement subsystem,
with noise levels in 10$\,\mu$K$\,$Hz$^{-1/2}$ down to $1\,$mHz was part of the
diagnostics unit on board LPF. In this paper we report on the temperature
measurements throughout mission operations, characterize the thermal
environment, estimate transfer functions between different locations and report
temperature stability (and its time evolution) at frequencies as low as
10$\,\mu$Hz, where typically values around $1\,$K$\,$Hz$^{-1/2}$ were measured.
[2]
oai:arXiv.org:1807.09330 [pdf] - 1942050
The Wide Field Monitor onboard the eXTP mission
Hernanz, M.;
Brandt, S.;
Feroci, M.;
Orleanski, P.;
Santangelo, A.;
Schanne, S.;
Wu, Xin;
Zand, J. in't;
Zhang, S. N.;
Xu, Y. P.;
Bozzo, E.;
Evangelista, Y.;
Gálvez, J. L.;
Tenzer, C.;
Zwart, F.;
Lu, F. J.;
Zhang, S.;
Chen, T. X.;
Ambrosino, F.;
Argan, A.;
Del Monte, E.;
Budtz-Jørgensen, C.;
Lund, N.;
Olsen, P.;
Mansanet, C.;
Campana, R.;
Fuschino, F.;
Labanti, C.;
Rachevski, A.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Rashevskaya, I.;
Bellutti, P.;
Borghi, G.;
Ficorella, F.;
Picciotto, A.;
Zorzi, N.;
Limousin, O.;
Meuris, A.
Submitted: 2018-07-24
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project
of the Chinese Academy of Sciences (CAS) and China National Space
Administration (CNSA) currently performing an extended phase A study and
proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload
envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry
Focusing Array, Large Area Detector and Wide Field Monitor) offering
unprecedented simultaneous wide-band X-ray timing and polarimetry sensitivity.
A large European consortium is contributing to the eXTP study and it is
expected to provide key hardware elements, including a Wide Field Monitor
(WFM). The WFM instrument for eXTP is based on the design originally proposed
for the LOFT mission within the ESA context. The eXTP/WFM envisages a wide
field X-ray monitor system in the 2-50 keV energy range, achieved through the
technology of the large-area Silicon Drift Detectors. The WFM will consist of 3
pairs of coded mask cameras with a total combined Field of View (FoV) of 90x180
degrees at zero response and a source localization accuracy of ~1 arcmin. In
this paper we provide an overview of the WFM instrument design, including new
elements with respect to the earlier LOFT configuration, and anticipated
performance.