sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mannino, R.

Normalized to: Mannino, R.

25 article(s) in total. 443 co-authors, from 1 to 25 common article(s). Median position in authors list is 53,0.

[1]  oai:arXiv.org:2003.11141  [pdf] - 2070172
An Effective Field Theory Analysis of the First LUX Dark Matter Search
Comments: 11 pages, 6 figures
Submitted: 2020-03-24
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
[2]  oai:arXiv.org:1907.06272  [pdf] - 2050176
Extending light WIMP searches to single scintillation photons in LUX
Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Baxter, A.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Boxer, B.; Brás, P.; Burdin, S.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Genovesi, J.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Grace, E.; Gwilliam, C.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Jahangir, O.; Ji, W.; Kamdin, K.; Kazka, K.; Khaitan, D.; Knoche, R.; Korolkova, E. V.; Kravitz, S.; Kudryavtsev, V. A.; Larsen, N. A.; Leason, E.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Levy, C.; Liao, J.; Lin, J.; Lindote, A.; Lopes, M. I.; López-Paredes, B.; Manalaysay, A.; Mannino, R. L.; Marangou, N.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Naylor, A.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; Nilima, A.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Reichhart, L.; Riffard, Q.; Rischbieter, G. R. C.; Rossiter, P.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, R.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Utku, U.; Uvarov, S.; Vacheret, A.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Woodward, D.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
Comments:
Submitted: 2019-07-14, last modified: 2019-12-27
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
[3]  oai:arXiv.org:1802.06039  [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.; Akerlof, C. W.; Alsum, S. K.; Araújo, H. M.; Arthurs, M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Bauer, D.; Belle, J.; Beltrame, P.; Benson, T.; Bernard, E. P.; Biesiadzinski, T. P.; Boast, K. E.; Boxer, B.; Brás, P.; Buckley, J. H.; Bugaev, V. V.; Burdin, S.; Busenitz, J. K.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Chan, C.; Cherwinka, J. J.; Cole, A.; Cottle, A.; Craddock, W. W.; Currie, A.; Cutter, J. E.; Dahl, C. E.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edberg, T. K.; Edwards, W. R.; Fan, A.; Fayer, S.; Fiorucci, S.; Fruth, T.; Gaitskell, R. J.; Genovesi, J.; Ghag, C.; Gilchriese, M. G. D.; van der Grinten, M. G. D.; Hall, C. R.; Hans, S.; Hanzel, K.; Haselschwardt, S. J.; Hertel, S. A.; Hillbrand, S.; Hjemfelt, C.; Hoff, M. D.; Hor, J. Y-K.; Huang, D. Q.; Ignarra, C. M.; Ji, W.; Kaboth, A. C.; Kamdin, K.; Keefner, J.; Khaitan, D.; Khazov, A.; Kim, Y. D.; Kocher, C. D.; Korolkova, E. V.; Kraus, H.; Krebs, H. J.; Kreczko, L.; Krikler, B.; Kudryavtsev, V. A.; Kyre, S.; Lee, J.; Lenardo, B. G.; Leonard, D. S.; Lesko, K. T.; Levy, C.; Li, J.; Liao, J.; Liao, F. -T.; Lin, J.; Lindote, A.; Linehan, R.; Lippincott, W. H.; Liu, X.; Lopes, M. I.; Paredes, B. López; Lorenzon, W.; Luitz, S.; Lyle, J. M.; Majewski, P.; Manalaysay, A.; Mannino, R. L.; Maupin, C.; McKinsey, D. N.; Meng, Y.; Miller, E. H.; Mock, J.; Monzani, M. E.; Morad, J. A.; Morrison, E.; Mount, B. J.; Murphy, A. St. J.; Nelson, H. N.; Neves, F.; Nikoleyczik, J.; O'Sullivan, K.; Olcina, I.; Olevitch, M. A.; Oliver-Mallory, K. C.; Palladino, K. J.; Patton, S. J.; Pease, E. K.; Penning, B.; Piepke, A.; Powell, S.; Preece, R. M.; Pushkin, K.; Ratcliff, B. N.; Reichenbacher, J.; Rhyne, C. A.; Richards, A.; Rodrigues, J. P.; Rosero, R.; Rossiter, P.; Saba, J. S.; Sarychev, M.; Schnee, R. W.; Schubnell, M.; Scovell, P. R.; Shaw, S.; Shutt, T. A.; Silk, J. J.; Silva, C.; Skarpaas, K.; Skulski, W.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stancu, I.; Stark, M. R.; Stiegler, T. M.; Stifter, K.; Szydagis, M.; Taylor, W. C.; Taylor, R.; Taylor, D. J.; Temples, D.; Terman, P. A.; Thomas, K. J.; Timalsina, M.; To, W. H.; Tomás, A.; Tope, T. E.; Tripathi, M.; Tull, C. E.; Tvrznikova, L.; Utku, U.; Va'vra, J.; Vacheret, A.; Verbus, J. R.; Voirin, E.; Waldron, W. L.; Watson, J. R.; Webb, R. C.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Witherell, M. S.; Wolfs, F. L. H.; Woodward, D.; Worm, S. D.; Yeh, M.; Yin, J.; Young, I.
Comments: 14 pages, 11 figures
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$ cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$ discovery potential is projected reaching cross sections below the existing and projected exclusion limits of similar experiments that are currently operating. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7 \times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
[4]  oai:arXiv.org:1910.09124  [pdf] - 1990394
The LUX-ZEPLIN (LZ) Experiment
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alquahtani, A.; Alsum, S. K.; Anderson, T. J.; Angelides, N.; Araújo, H. M.; Arbuckle, A.; Armstrong, J. E.; Arthurs, M.; Auyeung, H.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Bang, J.; Barry, M. J.; Barthel, J.; Bauer, D.; Bauer, P.; Baxter, A.; Belle, J.; Beltrame, P.; Bensinger, J.; Benson, T.; Bernard, E. P.; Bernstein, A.; Bhatti, A.; Biekert, A.; Biesiadzinski, T. P.; Birrittella, B.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Boxer, B.; Bramante, R.; Branson, S.; Brás, P.; Breidenbach, M.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Campbell, J. S.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Chott, N. I.; Cole, A.; Coleman, J.; Colling, D.; Conley, R. A.; Cottle, A.; Coughlen, R.; Craddock, W. W.; Curran, D.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dardin, S.; Dasu, S.; Davis, J.; Davison, T. J. R.; de Viveiros, L.; Decheine, N.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Dushkin, A.; Edberg, T. K.; Edwards, W. R.; Edwards, B. N.; Edwards, J.; Elnimr, M. M.; Emmet, W. T.; Eriksen, S. R.; Faham, C. H.; Fan, A.; Fayer, S.; Fiorucci, S.; Flaecher, H.; Florang, I. M. Fogarty; Ford, P.; Francis, V. B.; Froborg, F.; Fruth, T.; Gaitskell, R. J.; Gantos, N. J.; Garcia, D.; Geffre, A.; Gehman, V. M.; Gelfand, R.; Genovesi, J.; Gerhard, R. M.; Ghag, C.; Gibson, E.; Gilchriese, M. G. D.; Gokhale, S.; Gomber, B.; Gonda, T. G.; Greenall, A.; Greenwood, S.; Gregerson, G.; van der Grinten, M. G. D.; Gwilliam, C. B.; Hall, C. R.; Hamilton, D.; Hans, S.; Hanzel, K.; Harrington, T.; Harrison, A.; Hasselkus, C.; Haselschwardt, S. J.; Hemer, D.; Hertel, S. A.; Heise, J.; Hillbrand, S.; Hitchcock, O.; Hjemfelt, C.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Hor, J. Y-K.; Horn, M.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Irving, M. N.; Jacobsen, R. G.; Jahangir, O.; Jeffery, S. N.; Ji, W.; Johnson, M.; Johnson, J.; Johnson, P.; Jones, W. G.; Kaboth, A. C.; Kamaha, A.; Kamdin, K.; Kasey, V.; Kazkaz, K.; Keefner, J.; Khaitan, D.; Khaleeq, M.; Khazov, A.; Khromov, A. V.; Khurana, I.; Kim, Y. D.; Kim, W. T.; Kocher, C. D.; Konovalov, A. M.; Korley, L.; Korolkova, E. V.; Koyuncu, M.; Kras, J.; Kraus, H.; Kravitz, S. W.; Krebs, H. J.; Kreczko, L.; Krikler, B.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Lambert, A. R.; Landerud, B.; Larsen, N. A.; Laundrie, A.; Leason, E. A.; Lee, H. S.; Lee, J.; Lee, C.; Lenardo, B. G.; Leonard, D. S.; Leonard, R.; Lesko, K. T.; Levy, C.; Li, J.; Liu, Y.; Liao, J.; Liao, F. -T.; Lin, J.; Lindote, A.; Linehan, R.; Lippincott, W. H.; Liu, R.; Liu, X.; Loniewski, C.; Lopes, M. I.; Paredes, B. López; Lorenzon, W.; Lucero, D.; Luitz, S.; Lyle, J. M.; Lynch, C.; Majewski, P. A.; Makkinje, J.; Malling, D. C.; Manalaysay, A.; Manenti, L.; Mannino, R. L.; Marangou, N.; Markley, D. J.; MarrLaundrie, P.; Martin, T. J.; Marzioni, M. F.; Maupin, C.; McConnell, C. T.; McKinsey, D. N.; McLaughlin, J.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Minaker, Z. J.; Mizrachi, E.; Mock, J.; Molash, D.; Monte, A.; Monzani, M. E.; Morad, J. A.; Morrison, E.; Mount, B. J.; Murphy, A. St. J.; Naim, D.; Naylor, A.; Nedlik, C.; Nehrkorn, C.; Nelson, H. N.; Nesbit, J.; Neves, F.; Nikkel, J. A.; Nikoleyczik, J. A.; Nilima, A.; O'Dell, J.; Oh, H.; O'Neill, F. G.; O'Sullivan, K.; Olcina, I.; Olevitch, M. A.; Oliver-Mallory, K. C.; Oxborough, L.; Pagac, A.; Pagenkopf, D.; Pal, S.; Palladino, K. J.; Palmaccio, V. M.; Palmer, J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Penning, B. P.; Pereira, G.; Pereira, C.; Peterson, I. B.; Piepke, A.; Pierson, S.; Powell, S.; Preece, R. M.; Pushkin, K.; Qie, Y.; Racine, M.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C. A.; Richards, A.; Riffard, Q.; Rischbieter, G. R. C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Rossiter, P.; Rucinski, R.; Rutherford, G.; Rynders, D.; Saba, J. S.; Sabarots, L.; Santone, D.; Sarychev, M.; Sazzad, A. B. M. R.; Schnee, R. W.; Schubnell, M.; Scovell, P. R.; Severson, M.; Seymour, D.; Shaw, S.; Shutt, G. W.; Shutt, T. A.; Silk, J. J.; Silva, C.; Skarpaas, K.; Skulski, W.; Smith, A. R.; Smith, R. J.; Smith, R. E.; So, J.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stern, N.; Stevens, A.; Stiegler, T. M.; Stifter, K.; Studley, R.; Sumner, T. J.; Sundarnath, K.; Sutcliffe, P.; Swanson, N.; Szydagis, M.; Tan, M.; Taylor, W. C.; Taylor, R.; Taylor, D. J.; Temples, D.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; Timalsina, M.; To, W. H.; Tomás, A.; Tope, T. E.; Tripathi, M.; Tronstad, D. R.; Tull, C. E.; Turner, W.; Tvrznikova, L.; Utes, M.; Utku, U.; Uvarov, S.; Va'vra, J.; Vacheret, A.; Vaitkus, A.; Verbus, J. R.; Vietanen, T.; Voirin, E.; Vuosalo, C. O.; Walcott, S.; Waldron, W. L.; Walker, K.; Wang, J. J.; Wang, R.; Wang, L.; Wang, Y.; Watson, J. R.; Migneault, J.; Weatherly, S.; Webb, R. C.; Wei, W. -Z.; While, M.; White, R. G.; White, J. T.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Wilson, K.; Witherell, M. S.; Wolfs, F. L. H.; Wolfs, J. D.; Woodward, D.; Worm, S. D.; Xiang, X.; Xiao, Q.; Xu, J.; Yeh, M.; Yin, J.; Young, I.; Zhang, C.
Comments:
Submitted: 2019-10-20, last modified: 2019-11-03
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
[5]  oai:arXiv.org:1811.11241  [pdf] - 1981692
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Comments:
Submitted: 2018-11-27, last modified: 2019-10-16
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
[6]  oai:arXiv.org:1903.12372  [pdf] - 1916847
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Comments:
Submitted: 2019-03-29, last modified: 2019-06-07
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
[7]  oai:arXiv.org:1807.07113  [pdf] - 1758152
Search for annual and diurnal rate modulations in the LUX experiment
Comments: 12 pages, 9 figures
Submitted: 2018-07-18, last modified: 2018-09-27
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$\sigma$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
[8]  oai:arXiv.org:1709.00800  [pdf] - 1611913
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Comments: 10 pages, 10 figures, 2 tables
Submitted: 2017-09-03
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
[9]  oai:arXiv.org:1704.02297  [pdf] - 1582421
First Searches for Axions and Axion-Like Particles with the LUX Experiment
Comments:
Submitted: 2017-04-07, last modified: 2017-06-30
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90% C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are excluded. For galactic axion-like particles, values of gAe larger than 4.2 $\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16 keV/c$^{2}$. These are the most stringent constraints to date for these interactions.
[10]  oai:arXiv.org:1705.03380  [pdf] - 1583256
Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
Comments: 7 pages, 3 figures, version accepted by PRL
Submitted: 2017-05-09, last modified: 2017-06-23
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ = 5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
[11]  oai:arXiv.org:1703.09144  [pdf] - 1554108
LUX-ZEPLIN (LZ) Technical Design Report
Mount, B. J.; Hans, S.; Rosero, R.; Yeh, M.; Chan, C.; Gaitskell, R. J.; Huang, D. Q.; Makkinje, J.; Malling, D. C.; Pangilinan, M.; Rhyne, C. A.; Taylor, W. C.; Verbus, J. R.; Kim, Y. D.; Lee, H. S.; Lee, J.; Leonard, D. S.; Li, J.; Belle, J.; Cottle, A.; Lippincott, W. H.; Markley, D. J.; Martin, T. J.; Sarychev, M.; Tope, T. E.; Utes, M.; Wang, R.; Young, I.; Araújo, H. M.; Bailey, A. J.; Bauer, D.; Colling, D.; Currie, A.; Fayer, S.; Froborg, F.; Greenwood, S.; Jones, W. G.; Kasey, V.; Khaleeq, M.; Olcina, I.; Paredes, B. López; Richards, A.; Sumner, T. J.; Tomás, A.; Vacheret, A.; Brás, P.; Lindote, A.; Lopes, M. I.; Neves, F.; Rodrigues, J. P.; Silva, C.; Solovov, V. N.; Barry, M. J.; Cole, A.; Dobi, A.; Edwards, W. R.; Faham, C. H.; Fiorucci, S.; Gantos, N. J.; Gehman, V. M.; Gilchriese, M. G. D.; Hanzel, K.; Hoff, M. D.; Kamdin, K.; Lesko, K. T.; McConnell, C. T.; O'Sullivan, K.; Oliver-Mallory, K. C.; Patton, S. J.; Saba, J. S.; Sorensen, P.; Thomas, K. J.; Tull, C. E.; Waldron, W. L.; Witherell, M. S.; Bernstein, A.; Kazkaz, K.; Xu, J.; Akimov, D. Yu.; Bolozdynya, A. I.; Khromov, A. V.; Konovalov, A. M.; Kumpan, A. V.; Sosnovtsev, V. V.; Dahl, C. E.; Temples, D.; Carmona-Benitez, M. C.; de Viveiros, L.; Akerib, D. S.; Auyeung, H.; Biesiadzinski, T. P.; Breidenbach, M.; Bramante, R.; Conley, R.; Craddock, W. W.; Fan, A.; Hau, A.; Ignarra, C. M.; Ji, W.; Krebs, H. J.; Linehan, R.; Lee, C.; Luitz, S.; Mizrachi, E.; Monzani, M. E.; O'Neill, F. G.; Pierson, S.; Racine, M.; Ratcliff, B. N.; Shutt, G. W.; Shutt, T. A.; Skarpaas, K.; Stifter, K.; To, W. H.; Va'vra, J.; Whitis, T. J.; Wisniewski, W. J.; Bai, X.; Bunker, R.; Coughlen, R.; Hjemfelt, C.; Leonard, R.; Miller, E. H.; Morrison, E.; Reichenbacher, J.; Schnee, R. W.; Stark, M. R.; Sundarnath, K.; Tiedt, D. R.; Timalsina, M.; Bauer, P.; Carlson, B.; Horn, M.; Johnson, M.; Keefner, J.; Maupin, C.; Taylor, D. J.; Balashov, S.; Ford, P.; Francis, V.; Holtom, E.; Khazov, A.; Kaboth, A.; Majewski, P.; Nikkel, J. A.; O'Dell, J.; Preece, R. M.; van der Grinten, M. G. D.; Worm, S. D.; Mannino, R. L.; Stiegler, T. M.; Terman, P. A.; Webb, R. C.; Levy, C.; Mock, J.; Szydagis, M.; Busenitz, J. K.; Elnimr, M.; Hor, J. Y-K.; Meng, Y.; Piepke, A.; Stancu, I.; Kreczko, L.; Krikler, B.; Penning, B.; Bernard, E. P.; Jacobsen, R. G.; McKinsey, D. N.; Watson, R.; Cutter, J. E.; El-Jurf, S.; Gerhard, R. M.; Hemer, D.; Hillbrand, S.; Holbrook, B.; Lenardo, B. G.; Manalaysay, A. G.; Morad, J. A.; Stephenson, S.; Thomson, J. A.; Tripathi, M.; Uvarov, S.; Haselschwardt, S. J.; Kyre, S.; Nehrkorn, C.; Nelson, H. N.; Solmaz, M.; White, D. T.; Cascella, M.; Dobson, J. E. Y.; Ghag, C.; Liu, X.; Manenti, L.; Reichhart, L.; Shaw, S.; Utku, U.; Beltrame, P.; Davison, T. J. R.; Marzioni, M. F.; Murphy, A. St. J.; Nilima, A.; Boxer, B.; Burdin, S.; Greenall, A.; Powell, S.; Rose, H. J.; Sutcliffe, P.; Balajthy, J.; Edberg, T. K.; Hall, C. R.; Silk, J. S.; Hertel, S.; Akerlof, C. W.; Arthurs, M.; Lorenzon, W.; Pushkin, K.; Schubnell, M.; Boast, K. E.; Carels, C.; Fruth, T.; Kraus, H.; Liao, F. -T.; Lin, J.; Scovell, P. R.; Druszkiewicz, E.; Khaitan, D.; Koyuncu, M.; Skulski, W.; Wolfs, F. L. H.; Yin, J.; Korolkova, E. V.; Kudryavtsev, V. A.; Rossiter, P.; Woodward, D.; Chiller, A. A.; Chiller, C.; Mei, D. -M.; Wang, L.; Wei, W. -Z.; While, M.; Zhang, C.; Alsum, S. K.; Benson, T.; Carlsmith, D. L.; Cherwinka, J. J.; Dasu, S.; Gregerson, G.; Gomber, B.; Pagac, A.; Palladino, K. J.; Vuosalo, C. O.; Xiao, Q.; Buckley, J. H.; Bugaev, V. V.; Olevitch, M. A.; Boulton, E. M.; Emmet, W. T.; Hurteau, T. W.; Larsen, N. A.; Pease, E. K.; Tennyson, B. P.; Tvrznikova, L.
Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>
Submitted: 2017-03-27
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
[12]  oai:arXiv.org:1608.07648  [pdf] - 1531370
Results from a search for dark matter in the complete LUX exposure
Comments: This version includes a combined analysis with previously published LUX results, and matches the version published in PRL
Submitted: 2016-08-26, last modified: 2017-01-13
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
[13]  oai:arXiv.org:1608.05381  [pdf] - 1503451
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration; Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bradley, A.; Bramante, R.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chapman, J. J.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Malling, D. C.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Pease, E. K.; Phelps, P.; Reichhart, L.; Rhyne, C. A.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
Comments: 24 pages, 15 figures, 6 tables
Submitted: 2016-08-18, last modified: 2016-10-26
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
[14]  oai:arXiv.org:1512.03506  [pdf] - 1406496
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Comments: Accepted by Phys. Rev. Lett
Submitted: 2015-12-10, last modified: 2016-05-16
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $\beta$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
[15]  oai:arXiv.org:1512.03133  [pdf] - 1402511
Tritium calibration of the LUX dark matter experiment
Comments:
Submitted: 2015-12-09, last modified: 2016-05-05
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
[16]  oai:arXiv.org:1509.02910  [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alsum, S. K.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Barry, M. J.; Bauer, P.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Bramante, R.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Craddock, W. W.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dasu, S.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edberg, T. K.; Edwards, B. N.; Edwards, W. R.; Elnimr, M. M.; Emmet, W. T.; Faham, C. H.; Fiorucci, S.; Ford, P.; Francis, V. B.; Fu, C.; Gaitskell, R. J.; Gantos, N. J.; Gehman, V. M.; Gerhard, R. M.; Ghag, C.; Gilchriese, M. G. D.; Gomber, B.; Hall, C. R.; Harris, A.; Haselschwardt, S. J.; Hertel, S. A.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Ji, X.; Johnson, M.; Ju, Y.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Khazov, A.; Khromov, A. V.; Konovalov, A. M.; Korolkova, E. V.; Kraus, H.; Krebs, H. J.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Liao, F. -T.; Lin, J.; Lindote, A.; Lippincott, W. H.; Liu, J.; Liu, X.; Lopes, M. I.; Lorenzon, W.; Luitz, S.; Majewski, P.; Malling, D. C.; Manalaysay, A. G.; Manenti, L.; Mannino, R. L.; Markley, D. J.; Martin, T. J.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Mock, J.; Monzani, M. E.; Morad, J. A.; Murphy, A. St. J.; Nelson, H. N.; Neves, F.; Nikkel, J. A.; O'Neill, F. G.; O'Dell, J.; O'Sullivan, K.; Olevitch, M. A.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Piepke, A.; Powell, S.; Preece, R. M.; Pushkin, K.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Saba, J. S.; Sarychev, M.; Schnee, R. W.; Schubnell, M. S. G.; Scovell, P. R.; Shaw, S.; Shutt, T. A.; Silva, C.; Skarpaas, K.; Skulski, W.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stiegler, T. M.; Sumner, T. J.; Sundarnath, K.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; To, W. H.; Tomás, A.; Tripathi, M.; Tull, C. E.; Tvrznikova, L.; Uvarov, S.; Va'vra, J.; van der Grinten, M. G. D.; Verbus, J. R.; Vuosalo, C. O.; Waldron, W. L.; Wang, L.; Webb, R. C.; Wei, W. -Z.; While, M.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Witherell, M. S.; Wolfs, F. L. H.; Woods, E.; Woodward, D.; Worm, S. D.; Yeh, M.; Yin, J.; Young, S. K.; Zhang, C.
Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
[17]  oai:arXiv.org:1403.1299  [pdf] - 862558
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Comments: 18 pages, 12 figures / 17 images, submitted to Astropart. Phys
Submitted: 2014-03-05
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
[18]  oai:arXiv.org:1402.3731  [pdf] - 788195
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Comments: 16 pages, 3 figures, to appear in the proceedings of The 10th International Symposium on Cosmology and Particle Astrophysics (CosPA2013); fixed author list and added info on new calibration
Submitted: 2014-02-15, last modified: 2014-02-25
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
[19]  oai:arXiv.org:1310.8214  [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
[20]  oai:arXiv.org:1205.2272  [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Comments: v2 updated to include content after reviewer comments (Sep 2012)
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
[21]  oai:arXiv.org:1210.4569  [pdf] - 630139
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Comments:
Submitted: 2012-10-16, last modified: 2013-02-22
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
[22]  oai:arXiv.org:1207.3665  [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Comments: 12 pages, 9 figures
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.
[23]  oai:arXiv.org:1110.0103  [pdf] - 967104
After LUX: The LZ Program
Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
[24]  oai:arXiv.org:1108.1836  [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Comments:
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
[25]  oai:arXiv.org:0912.0482  [pdf] - 902613
Status of the LUX Dark Matter Search
Comments: 4 pages, in proceedings of the SUSY09 conference
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.