Normalized to: Manghisoni, M.
[1]
oai:arXiv.org:2002.04163 [pdf] - 2046557
Cosmic-ray Antinuclei as Messengers of New Physics: Status and Outlook
for the New Decade
von Doetinchem, P.;
Perez, K.;
Aramaki, T.;
Baker, S.;
Barwick, S.;
Bird, R.;
Boezio, M.;
Boggs, S. E.;
Cui, M.;
Datta, A.;
Donato, F.;
Evoli, C.;
Fabris, L.;
Fabbietti, L.;
Bueno, E. Ferronato;
Fornengo, N.;
Fuke, H.;
Gerrity, C.;
Coral, D. Gomez;
Hailey, C.;
Hooper, D.;
Kachelriess, M.;
Korsmeier, M.;
Kozai, M.;
Lea, R.;
Li, N.;
Lowell, A.;
Manghisoni, M.;
Moskalenko, I. V.;
Munini, R.;
Naskret, M.;
Nelson, T.;
Ng, K. C. Y.;
Nozzoli, F.;
Oliva, A.;
Ong, R. A.;
Osteria, G.;
Pierog, T.;
Poulin, V.;
Profumo, S.;
Poeschl, T.;
Quinn, S.;
Re, V.;
Rogers, F.;
Ryan, J.;
Saffold, N.;
Sakai, K.;
Salati, P.;
Schael, S.;
Serksnyte, L.;
Shukla, A.;
Stoessl, A.;
Tjemsland, J.;
Vannuccini, E.;
Vecchi, M.;
Winkler, M. W.;
Wright, D.;
Xiao, M.;
Xu, W.;
Yoshida, T.;
Zampa, G.;
Zuccon, P.
Submitted: 2020-02-10
The precise measurement of cosmic-ray antinuclei serves as an important means
for identifying the nature of dark matter and other new astrophysical
phenomena, and could be used with other cosmic-ray species to understand
cosmic-ray production and propagation in the Galaxy. For instance, low-energy
antideuterons would provide a "smoking gun" signature of dark matter
annihilation or decay, essentially free of astrophysical background. Studies in
recent years have emphasized that models for cosmic-ray antideuterons must be
considered together with the abundant cosmic antiprotons and any potential
observation of antihelium. Therefore, a second dedicated Antideuteron Workshop
was organized at UCLA in March 2019, bringing together a community of theorists
and experimentalists to review the status of current observations of cosmic-ray
antinuclei, the theoretical work towards understanding these signatures, and
the potential of upcoming measurements to illuminate ongoing controversies.
This review aims to synthesize this recent work and present implications for
the upcoming decade of antinuclei observations and searches. This includes
discussion of a possible dark matter signature in the AMS-02 antiproton
spectrum, the most recent limits from BESS Polar-II on the cosmic antideuteron
flux, and reports of candidate antihelium events by AMS-02; recent collider and
cosmic-ray measurements relevant for antinuclei production models; the state of
cosmic-ray transport models in light of AMS-02 and Voyager data; and the
prospects for upcoming experiments, such as GAPS. This provides a roadmap for
progress on cosmic antinuclei signatures of dark matter in the coming years.
[2]
oai:arXiv.org:1912.06571 [pdf] - 2014538
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking
for the GAPS Experiment
Rogers, Field;
Xiao, Mengjiao;
Perez, Kerstin;
Boggs, Steven;
Erjavec, Tyler;
Fabris, Lorenzo;
Fuke, Hideyuki;
Hailey, Charles J.;
Kozai, Masayoshi;
Lowell, Alex;
Madden, Norman;
Manghisoni, Massimo;
McBride, Steve;
Re, Valerio;
Riceputi, Elisa;
Saffold, Nathan;
Shimizu, Yuki;
Zampa, Gianluigi
Submitted: 2019-12-13
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150{\deg}C
above liquid nitrogen temperature, have been developed for the General
Antiparticle Spectrometer (GAPS) balloon mission and will form the first such
system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip
detectors have been verified in the lab to provide <4 keV FWHM energy
resolution for X-rays as well as tracking capability for charged particles,
while operating in conditions (~-40{\deg}C and ~1 Pa) achievable on a
long-duration balloon mission with a large detector payload. These
characteristics enable the GAPS silicon tracker system to identify cosmic
antinuclei via a novel technique based on exotic atom formation, de-excitation,
and annihilation. Production and large-scale calibration of ~1000 detectors has
begun for the first GAPS flight, scheduled for late 2021. The detectors
developed for GAPS may also have other applications, for example in heavy
nuclei identification.
[3]
oai:arXiv.org:1906.00054 [pdf] - 1995412
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking
in the GAPS experiment
Rogers, Field;
Xiao, Mengjiao;
Perez, Kerstin M.;
Boggs, Steven;
Erjavec, Tyler;
Fabris, Lorenzo;
Fuke, Hideyuki;
Hailey, Charles J.;
Kozai, Masayoshi;
Lowell, Alex;
Madden, Norman;
Manghisoni, Massimo;
McBride, Steve;
Re, Valerio;
Riceputi, Elisa;
Saffold, Nathan;
Shimizu, Yuki
Submitted: 2019-05-31, last modified: 2019-11-08
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique
geometric, performance, and cost requirements of the General Antiparticle
Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The
GAPS Si(Li) detectors will form the first large-area, relatively
high-temperature Si(Li) detector system with sensitivity to X-rays to operate
at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors
provide the active area, X-ray absorption efficiency, energy resolution, and
particle tracking capability necessary for the GAPS exotic-atom particle
identification technique. In this paper, the detector performance is validated
on the bases of X-ray energy resolution and reconstruction of cosmic minimum
ionizing particle (MIP) signals. We use the established noise model for
semiconductor detectors to distinguish sources of noise due to the detector
from those due to signal processing electronics. We demonstrate that detectors
with either 4 strips or 8 strips can provide the required $\lesssim$4 keV
(FWHM) X-ray energy resolution at flight temperatures of $-35$ to
$-45^{\circ}$C, given the proper choice of signal processing electronics.
Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic
balloon flight, scheduled for late 2021.
[4]
oai:arXiv.org:1909.01682 [pdf] - 1955438
Front-end electronics for the GAPS tracker
Submitted: 2019-09-04
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne
mission to indirectly search for dark matter through sensitive observation of
cosmic antiparticles. The first flight is planned for late 2021. GAPS is the
first experiment optimized specifically for detection of low-energy (< 0.25
GeV/n) antideuterons, which are recognized as distinctive signals from dark
matter annihilation or decay in the Galactic halo. To achieve high sensitivity
to cosmic antinuclei in this low-energy range, GAPS uses a novel particle
identification method based on exotic atom capture and decay. The GAPS
instrument consists of ten planes of 1440 10 cm-diameter, 2.5 mm-thick, 8-strip
lithium drifted silicon (Si(Li)) detectors, which constitutes the tracker,
surrounded by a plastic scintillator time-of-flight system. A new fabrication
technique has been developed to satisfy the stringent requirements of the
mission. In this contribution, we describe the front-end electronics of the
tracker of GAPS. The system is composed of front-end ASICs and power supplies.
The ASICs provide readout and digitization of the signal (with an 11-bit ADC)
in a wide dynamic range (10 keV - 100 MeV). Every ASIC has 32 channels and
performs the readout for 4 detectors, for a total amount of 11520 channels. The
ASIC analog front-end is based on a dynamic compression technique to handle a
large range of signal amplitudes and features a low noise performance,
achieving the required 4 keV resolution at low energies. The power system
supplies both bias voltages for the Si(Li) detectors and low voltages for the
electronics. 36th
[5]
oai:arXiv.org:1908.03154 [pdf] - 1931578
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Bird, R.;
Aramaki, T.;
Boezio, M.;
Boggs, S. E.;
Bonvicini, V.;
Campana, D.;
Craig, W. W.;
Everson, E.;
Fabris, L.;
Fuke, H.;
Gahbauer, F.;
Garcia, I.;
Gerrity, C.;
Hailey, C. J.;
Hayashi, T.;
Kato, C.;
Kawachi, A.;
Kondo, M.;
Kozai, M.;
Lowell, A.;
Manghisoni, M.;
Marcelli, N.;
Martucci, M.;
Mognet, S. I.;
Munakata, K.;
Munini, R.;
Okazaki, S.;
Olson, J.;
Ong, R. A.;
Osteria, G.;
Perez, K.;
Quinn, S.;
Re, V.;
Riceputi, E.;
Rogers, F.;
Ryan, J. L.;
Saffold, N.;
Scotti, V.;
Shimizu, Y.;
Sparvoli, R.;
Stoessl, A.;
Takeuchi, S.;
Vannuccini, E.;
von Doetinchem, P.;
Wada, T.;
Xiao, M.;
Yoshida, A.;
Yoshida, T.;
Zampa, G.;
Zweerink, J.
Submitted: 2019-08-08
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark
matter search by measuring low-energy ($\mathrm{E} < 0.25
\mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are
low-energy antideuterons produced in the annihilation or decay of dark matter.
At these energies antideuterons from secondary/tertiary interactions are
expected to have very low fluxes, significantly below those predicted by
well-motivated, beyond the standard model theories. GAPS will also conduct
low-energy antiproton and antihelium searches. Combined, these observations
will provide a powerful search for dark matter and provide the best
observations to date on primordial black hole evaporation on Galactic length
scales.
The GAPS instrument detects antinuclei using the novel exotic atom technique.
It consists of a central tracker with a surrounding time-of-flight (TOF)
system. The tracker is a one cubic meter volume containing 10 cm-diameter
lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator
system that will both trigger the Si(Li) tracker and enable better
reconstruction of particle tracks. After coming to rest in the tracker,
antinuclei will form an excited exotic atom. This will then de-excite via
characteristic X-ray transitions before producing a pion/proton star when the
antiparticle annihilates with the nucleus. This unique event topology will give
GAPS the nearly background-free detection capability required for a rare-event
search.
Here we present the scientific motivation for the GAPS experiment, its design
and its current status as it prepares for flight in the austral summer of
2021-22.