Normalized to: Mancuso, M.
[1]
oai:arXiv.org:2005.02692 [pdf] - 2090731
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on
spin-dependent dark matter interactions with ordinary matter
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Breier, R.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuchs, D.;
Fuss, A.;
Ghete, V. M.;
Garai, A.;
Gorla, P.;
Hauff, D.;
Ješkovský, M.;
Jochum, J.;
Kaizer, J.;
Kaznacheeva, M.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Palušová, V.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Povinec, P.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Usherov, I.;
Wagner, F.;
Willers, M.;
Zema, V.;
Zeman, J.;
Brützam, M.;
Ganschow, S.
Submitted: 2020-05-06
In this work, a first cryogenic characterization of a scintillating
LiAlO$_{2}$ single crystal is presented. The results achieved show that this
material holds great potential as a target for direct dark matter search
experiments. Three different detector modules obtained from one crystal grown
at the Leibniz-Institut f\"ur Kristallz\"uchtung (IKZ) have been tested to
study different properties at cryogenic temperatures. Firstly, two 2.8 g twin
crystals were used to build different detector modules which were operated in
an above-ground laboratory at the Max Planck Institute for Physics (MPP) in
Munich, Germany. The first detector module was used to study the scintillation
properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an
energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive
limit on the spin-dependent dark matter particle-proton scattering cross
section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50
GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as
the main absorber was tested in an underground facility at the Laboratori
Nazionali del Gran Sasso (LNGS): from this measurement it was possible to
determine the radiopurity of the crystal and study the feasibility of using
this material as a neutron flux monitor for low-background experiments.
[2]
oai:arXiv.org:2004.08121 [pdf] - 2119942
New limits on the resonant absorption of solar axions obtained with a
$^{169}$Tm-containing cryogenic detector
Abdelhameed, A. H.;
Bakhlanov, S. V.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Canonica, L.;
Derbin, A. V.;
Drachnev, I. S.;
Iachellini, N. Ferreiro;
Fuchs, D.;
Hauff, D.;
Laubenstein, M.;
Lis, D. A.;
Lomskaya, I. S.;
Mancuso, M.;
Muratova, V. N.;
Nagorny, S.;
Nisi, S.;
Petricca, F.;
Proebst, F.;
Rothe, J.;
Ryabchenkov, V. V.;
Sarkisov, S. E.;
Semenov, D. A.;
Subbotin, K. A.;
Trushin, M . V.;
Unzhakov, E. V.;
Zharikov, E. V.
Submitted: 2020-04-17
A search for resonant absorption of solar axions by $^{169}$Tm nuclei was
carried out. A newly developed approach involving low-background cryogenic
bolometer based on Tm$_3$Al$_5$O$_{12}$ crystal was used that allowed for
significant improvement of sensitivity in comparison with previous $^{169}$Tm
based experiments. The measurements performed with $8.18$ g crystal during
$6.6$ days exposure yielded the following limits on axion couplings:
$|g_{A\gamma} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14}$ GeV$^{-1}$ and
$|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}$.
[3]
oai:arXiv.org:1905.07335 [pdf] - 2075555
Description of CRESST-III Data
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-05-17, last modified: 2020-04-06
In CRESST-III, 10 cryogenic detector modules optimized for low energy
thresholds were operated for almost two years (May 2016 - February 2018).
Together with this document we are publishing data from the best performing
detector module which has a nuclear recoil threshold of 30.1eV. With this
data-set we were able to set limits on the cross-section for spin-dependent and
spin-independent elastic scattering of dark matter particles off nuclei at dark
matter masses down to 160MeV/c$^2$. We publish the energies of all events after
data selection as well as of all events within the acceptance region for
dark-matter searches. In this document we describe how to use these data sets.
[4]
oai:arXiv.org:1902.07587 [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with
$^{7}$Li
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Chapellier, M.;
Giuliani, A.;
Nones, C.;
Poda, D. V.;
Shlegel, V. N.;
Velázquez, M.;
Zolotarova, A. S.
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for
spin-dependent dark matter search in cryogenic experiments, with a special
focus on the low-mass region of the parameter space. We operated a prototype
detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground
laboratory. Despite the high background environment, the detector sets
competitive limits on spin-dependent interactions of dark matter particles with
protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[5]
oai:arXiv.org:1908.06755 [pdf] - 2001880
Geant4-based electromagnetic background model for the CRESST dark matter
experiment
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Breier, R.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Ješkovský, M.;
Jochum, J.;
Kaizer, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragón, E.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Palušová, V.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Povinec, P.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoğlu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Zeman, J.
Submitted: 2019-08-19
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers)
dark matter search experiment aims for the detection of dark matter particles
via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand
the CRESST electromagnetic background due to the bulk contamination in the
employed materials, a model based on Monte Carlo simulations was developed
using the Geant4 simulation toolkit. The results of the simulation are applied
to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to
$(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy
range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.
[6]
oai:arXiv.org:1905.12952 [pdf] - 2025534
A Test of Bolometric Properties of Tm-containing Crystals as a
Perspective Detector for the Solar Axion Search
Bertoldo, E.;
Derbin, A. V.;
Drachnev, I. S.;
Laubenstein, M.;
Lis, D. A.;
Mancuso, M.;
Muratova, V. N.;
Nagorny, S.;
Nisi, S.;
Petricca, F.;
Ryabchenkov, V. V.;
Sarkisov, S. E.;
Semenov, D. A.;
Subbotin, K. A.;
Unzhakov, E. V.;
Zharikov, E. V.
Submitted: 2019-05-30
The $^{169}$Tm nuclide has first nuclear level at 8.41 keV with magnetic type
transition to the ground state and, therefore, can be used as a target nucleus
for the search of resonant absorption of solar axions. We plan to use a
Tm-containing crystal of a garnet family Tm$_3$Al$_5$O$_{12}$ as a bolometric
detector in order to search for the excitation of the first nuclear level of
$^{169}$Tm via the resonant absorption of solar axions. With this perspective
in mind, a sample of the Tm$_3$Al$_5$O$_{12}$ crystal was grown and tested for
its bolometric and optical properties. Measurements of chemical and/or
radioactive contaminations were performed as well. In this paper we present the
test results and estimate the requirements for a future low-background
experimental setup.
[7]
oai:arXiv.org:1904.00498 [pdf] - 2007901
First results from the CRESST-III low-mass dark matter program
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-03-31
The CRESST experiment is a direct dark matter search which aims to measure
interactions of potential dark matter particles in an earth-bound detector.
With the current stage, CRESST-III, we focus on a low energy threshold for
increased sensitivity towards light dark matter particles. In this manuscript
we describe the analysis of one detector operated in the first run of
CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV.
This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic
scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del
Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously
emitted scintillation light, which is absorbed in a separate
silicon-on-sapphire light absorber, are measured with highly sensitive
transition edge sensors operated at ~15mK. The unique combination of these
sensors with the light element oxygen present in our target yields sensitivity
to dark matter particle masses as low as 160MeV/c$^2$.
[8]
oai:arXiv.org:1711.07692 [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaboration;
Petricca, F.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Lagenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in
Italy, searches for dark matter particles via their elastic scattering off
nuclei in a target material. The CRESST target consists of scintillating
CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin
temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon
signal and a light signal that is measured by a second cryogenic calorimeter.
Since the CRESST-II result in 2015, the experiment is leading the field of
direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$,
extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For
CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized
to reach the performance required to further probe the low-mass region with
unprecedented sensitivity. In this contribution the achievements of the
CRESST-III detectors will be discussed together with preliminary results and
perspectives of Phase 1.
[9]
oai:arXiv.org:1711.01482 [pdf] - 2082284
Results of the first NaI scintillating calorimeter prototypes by COSINUS
COSINUS collaboration;
Reindl, F.;
Angloher, G.;
Carniti, P.;
Cassina, L.;
Gironi, L.;
Gotti, C.;
Gütlein, A.;
Maino, M.;
Mancuso, M.;
Di Marco, N.;
Pagnanini, L.;
Pessina, G.;
Petricca, F.;
Pirro, S.;
Pröbst, F.;
Puig, R.;
Schäffner, K.;
Schieck, J.
Submitted: 2017-11-04
Over almost three decades the TAUP conference has seen a remarkable momentum
gain in direct dark matter search. An important accelerator were first
indications for a modulating signal rate in the DAMA/NaI experiment reported in
1997. Today the presence of an annual modulation, which matches in period and
phase the expectation for dark matter, is supported at > 9$\sigma$ confidence.
The underlying nature of dark matter, however, is still considered an open and
fundamental question of particle physics. No other direct dark matter search
could confirm the DAMA claim up to now; moreover, numerous null-results are in
clear contradiction under so-called standard assumptions for the dark matter
halo and the interaction mechanism of dark with ordinary matter. As both bear a
dependence on the target material, resolving this controversial situation will
convincingly only be possible with an experiment using sodium iodide (NaI) as
target. COSINUS aims to even go a step further by combining NaI with a novel
detection approach. COSINUS aims to operate NaI as a cryogenic calorimeter
reading scintillation light and phonon/heat signal. Two distinct advantages
arise from this approach, a substantially lower energy threshold for nuclear
recoils and particle identification on an event-by-event basis. These key
benefits will allow COSINUS to clarify a possible nuclear recoil origin of the
DAMA signal with comparatively little exposure of O(100kg days) and, thereby,
answer a long-standing question of particle physics. Today COSINUS is in R&D
phase; in this contribution we show results from the 2nd prototype, albeit the
first one of the final foreseen detector design. The key finding of this
measurement is that pure, undoped NaI is a truly excellent scintillator at low
temperatures: We measure 13.1% of the total deposited energy in the NaI crystal
in the form of scintillation light (in the light detector).
[10]
oai:arXiv.org:1711.01285 [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Kluck, H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM)
using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading
limits for the spin-independent DM-nucleon cross section down to DM-particle
masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST
performed a dedicated search for dark photons (DP) which excludes new parameter
space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to
$700\,\mathrm{eV/c^2}$.
In this contribution we will discuss the latest results based on the previous
CRESST-II phase 2 and we will report on the status of the current CRESST-III
phase 1: in this stage we have been operating 10 upgraded detectors with
$24,\mathrm{g}$ target mass each and enhanced detector performance since summer
2016. The improved detector design in terms of background suppression and
reduction of the detection threshold will be discussed with respect to the
previous stage. We will conclude with an outlook on the potential of the next
stage, CRESST-III phase 2.
[11]
oai:arXiv.org:1707.06749 [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter
operated above ground
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, A. Langenkämper J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Oberauer, L.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoglu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[12]
oai:arXiv.org:1708.01581 [pdf] - 1586787
Performance of a CRESST-II Detector Module with True $4\pi$-veto
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, V. Schipperges S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-08-04
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
[13]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[14]
oai:arXiv.org:1611.02113 [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Schieck, J;
Angloher, G;
Bento, A;
Bucci, C;
Canonica, L;
Defay, X;
Erb, A;
Feilitzsch, F v;
Iachellini, N Ferreiro;
Gorla, P;
Guetlein, A;
Hauff, D;
Jochum, J;
Kiefer, M;
Kluck, H;
Kraus, H;
Lanfranchi, J-C;
Loebell, J;
Mancuso, M;
Muenster, A;
Pagliarone, C;
Petricca, F;
Potzel, W;
Pröbst, F;
Puig, R;
Reindl, F;
Schaeffner, K;
Schoenert, S;
Seidel, W;
Stahlberg, M;
Stodolsky, L;
Strandhagen, C;
Strauss, R;
Tanzke, A;
Thi, H H Trinh;
Turkoglu, C;
Uffinger, M;
Ulrich, A;
Usherov, I;
Wawoczny, S;
Willers, M;
Wueustrich, M;
Zoeller, A
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open
questions of modern physics. A well motivated candidate for dark matter is the
so-called WIMP - a weakly interacting massive particle. Recently several
theoretically well-motivated models with dark matter candidates in a mass
region below the WIMP mass-scale gained also a lot of interest, theoretically
and experimentally. The CRESST II experiment located at the Gran Sasso
laboratory in Italy is optimised for the detection of the elastic scattering of
these low-mass dark matter particles with ordinary matter. We show the results
obtained with an improved detector setup with increased radio purity and
enhanced background rejection and the results obtained with a dedicated
low-threshold analysis of a single conventional detector module. The limit
achieved is the most stringent limit achieved for direct dark matter
experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the
expected performance for new small CRESST-type detectors to be used during the
next data taking phase. We conclude with an outlook of the future potential for
direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic
detectors.
[15]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[16]
oai:arXiv.org:1307.1488 [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoit, A.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
de Boissière, T.;
De Jesus, M.;
Dolgorouky, Y.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Holtzer, N.;
Humbert, V.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Mancuso, M.;
Marrache-Kikuchi, C.;
Marnieros, S.;
Menshikov, A.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. C.;
Rigaut, O.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Tenconi, M.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more
indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times
g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the
effective axion-nucleon coupling for $^{57}$Fe. Combining these results we
fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and
$5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.