sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Malinine, A.

Normalized to: Malinine, A.

10 article(s) in total. 93 co-authors, from 1 to 10 common article(s). Median position in authors list is 18,5.

[1]  oai:arXiv.org:1003.4745  [pdf] - 1700287
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Comments: This submission has been withdrawn by arXiv administrators because it is a duplicate of arXiv:physics/0507174
Submitted: 2010-03-24, last modified: 2018-06-15
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
[2]  oai:arXiv.org:1102.2575  [pdf] - 391297
Cosmic-Ray Proton and Helium Spectra from the First CREAM Flight
Comments: 20 pages, 4 figures
Submitted: 2011-02-13
Cosmic-ray proton and helium spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data were collected at an average altitude of ~38.5 km with an average atmospheric overburden of ~3.9 g cm$^{-2}$. Individual elements are clearly separated with a charge resolution of ~0.15 e (in charge units) and ~0.2 e for protons and helium nuclei, respectively. The measured spectra at the top of the atmosphere are represented by power laws with a spectral index of -2.66 $\pm$ 0.02 for protons from 2.5 TeV to 250 TeV and -2.58 $\pm$ 0.02 for helium nuclei from 630 GeV/nucleon to 63 TeV/nucleon. They are harder than previous measurements at a few tens of GeV/nucleon. The helium flux is higher than that expected from the extrapolation of the power law fitted to the lower-energy data. The relative abundance of protons to helium nuclei is 9.1 $\pm$ 0.5 for the range from 2.5 TeV/nucleon to 63 TeV/nucleon. This ratio is considerably smaller than the previous measurements at a few tens of GeV/nucleon.
[3]  oai:arXiv.org:1003.4983  [pdf] - 1025943
Elemental Spectra from the CREAM-I Flight
Comments: Proc. 30th Int. Cosmic Ray Conf., Merida, 2, 63-66, 2007
Submitted: 2010-03-25, last modified: 2010-03-30
The Cosmic Ray Energetics And Mass (CREAM) is a balloon-borne experiment designed to measure the composition and energy spectra of cosmic rays of charge Z = 1 to 26 up to an energy of ~ 10^15 eV. CREAM had two successful flights on long-duration balloons (LDB) launched from Mc- Murdo Station, Antarctica, in December 2004 and December 2005. CREAM-I achieves a substantial measurement redundancy by employing multiple detector systems, namely a Timing Charge Detector and a Silicon Charge Detector (SCD) for particle identification, and a Transition Radiation Detector and a sampling tungsten/scintillating-fiber ionization calorimeter (CAL) for energy measurement. In this paper, preliminary energy spectra of various elements measured with CAL/SCD during the first 42-day flight are presented.
[4]  oai:arXiv.org:1003.5753  [pdf] - 138200
Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter
Comments: 4 pages, 3 figures, presented at ICRC 2008
Submitted: 2010-03-30
The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicraynuclei. Each detector was calibrated with particle beams in a limited range of energies. In order to assess the absolute energy scale of the instrument and to investigate the systematic effects of each technique, a cross-calibration was performed by comparing the two independent energy estimates on selected samples of oxygen and carbon nuclei.
[5]  oai:arXiv.org:1003.5759  [pdf] - 138204
Elemental energy spectra of cosmic rays measured by CREAM-II
Comments: 4 pages, 3 figures, presented at ICRC 2009, Lodz, Poland
Submitted: 2010-03-30
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment CREAM (Cosmic Ray Energetics And Mass). The instrument (CREAM-II) was comprised of detectors based on different techniques (Cherenkov light, specific ionization in scintillators and silicon sensors) to provide a redundant charge identification and a thin ionization calorimeter capable of measuring the energy of cosmic rays up to several hundreds of TeV. The data analysis is described and the individual energy spectra of C, O, Ne, Mg, Si and Fe are reported up to ~ 10^14 eV. The spectral shape looks nearly the same for all the primary elements and can be expressed as a power law in energy E^{-2.66+/-0.04}. The nitrogen absolute intensity in the energy range 100-800 GeV/n is also measured.
[6]  oai:arXiv.org:1003.5757  [pdf] - 270038
Measurements of cosmic-ray energy spectra with the 2nd CREAM flight
Comments: 4 pages, 3 figures, presented at XV International Symposium on Very High Energy Cosmic Ray Interactions (ISVHECRI 2008)
Submitted: 2010-03-30
During its second Antarctic flight, the CREAM (Cosmic Ray Energetics And Mass) balloon experiment collected data for 28 days, measuring the charge and the energy of cosmic rays (CR) with a redundant system of particle identification and an imaging thin ionization calorimeter. Preliminary direct measurements of the absolute intensities of individual CR nuclei are reported in the elemental range from carbon to iron at very high energy.
[7]  oai:arXiv.org:1003.4743  [pdf] - 137064
Performance of the CREAM calorimeter in accelerator beam test
Comments: 29th International Cosmic Ray Conference Pune (2005) 8, 371-374
Submitted: 2010-03-24
The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20 layers of scintillating fiber ribbons, and is preceded by a pair of graphite interaction targets providing about 0.42 proton interaction lengths (\lambda int). The calorimeter was placed in one of CERN's SPS accelerator beams for calibration and testing. Beams of 150 GeV electrons were used for calibration, and a variety of electron, proton, and nuclear fragment beams were used to test the simulation model of the detector. In this paper we discuss the performance of the calorimeter in the electron beam and compare electron beam data with simulation results.
[8]  oai:arXiv.org:0911.1889  [pdf] - 902364
Energy spectra of cosmic-ray nuclei at high energies
Comments: 32 pages, 10 figures. Accepted for publication in Astrophysical Journal
Submitted: 2009-11-10
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment Cosmic Ray Energetics And Mass (CREAM). The instrument included different particle detectors to provide redundant charge identification and measure the energy of CRs up to several hundred TeV. The measured individual energy spectra of C, O, Ne, Mg, Si, and Fe are presented up to $\sim 10^{14}$ eV. The spectral shape looks nearly the same for these primary elements and it can be fitted to an $E^{-2.66 \pm 0.04}$ power law in energy. Moreover, a new measurement of the absolute intensity of nitrogen in the 100-800 GeV/$n$ energy range with smaller errors than previous observations, clearly indicates a hardening of the spectrum at high energy. The relative abundance of N/O at the top of the atmosphere is measured to be $0.080 \pm 0.025 $(stat.)$ \pm 0.025 $(sys.) at $\sim $800 GeV/$n$, in good agreement with a recent result from the first CREAM flight.
[9]  oai:arXiv.org:astro-ph/0603852  [pdf] - 81061
The Ring Imaging Cherenkov detector (RICH) of the AMS experiment
Comments: 29th International Conference on Cosmic Rays (Pune, India)
Submitted: 2006-03-31
The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and velocity of the charged cosmic particles. A RICH prototype consisting of 96 photomultiplier units, including a piece of the conical reflector, was built and its performance evaluated with ion beam data. Preliminary results of the in-beam tests performed with ion fragments resulting from collisions of a 158 GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported. The collected data included tests to the final front-end electronics and to different aerogel radiators. Cherenkov rings for a large range of charged nuclei and with reflected photons were observed. The data analysis confirms the design goals. Charge separation up to Fe and velocity resolution of the order of 0.1% for singly charged particles are obtained.
[10]  oai:arXiv.org:astro-ph/0306224  [pdf] - 57305
The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -
Comments: 4 pages, contribution to the ICRC 2003
Submitted: 2003-06-11
A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by means of a low intensity 20 GeV/c per nucleon ion beam obtained by fragmentation of a primary beam of Pb ions. Data have been collected with a single beam setting, over the range of nuclear charges 2<Z<~45 in various beam conditions and using different radiators. The charge Z and velocity beta resolutions have been measured.