sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Malinin, A.

Normalized to: Malinin, A.

5 article(s) in total. 75 co-authors, from 1 to 5 common article(s). Median position in authors list is 21,0.

[1]  oai:arXiv.org:1004.1123  [pdf] - 144585
Discrepant hardening observed in cosmic-ray elemental spectra
Comments: 21 pages, 5 figures, published in ApJL (corresponding author: seo@umd.edu)
Submitted: 2010-04-07
The balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment launched five times from Antarctica has achieved a cumulative flight duration of about 156 days above 99.5% of the atmosphere. The instrument is configured with complementary and redundant particle detectors designed to extend direct measurements of cosmic-ray composition to the highest energies practical with balloon flights. All elements from protons to iron nuclei are separated with excellent charge resolution. Here we report results from the first two flights of ~70 days, which indicate hardening of the elemental spectra above ~200 GeV/nucleon and a spectral difference between the two most abundant species, protons and helium nuclei. These results challenge the view that cosmic-ray spectra are simple power laws below the so-called knee at ~1015 eV. This discrepant hardening may result from a relatively nearby source, or it could represent spectral concavity caused by interactions of cosmic rays with the accelerating shock. Other possible explanations should also be investigated.
[2]  oai:arXiv.org:1003.4737  [pdf] - 137061
Calibration of the CREAM-I calorimeter
Comments: Proc. 30th Int. Cosmic Ray Conf., Merida, 2, 421-424, 2007
Submitted: 2010-03-24
The Cosmic Ray Energetics And Mass (CREAM) calorimeter is designed to measure the spectra of cosmic-ray particles over the energy range from ~10^11 eV to ~10^15 eV. Its first flight as part of the CREAM-I balloon-borne payload in Antarctica during the 2004/05 season resulted in a recordbreaking 42 days of exposure. Calorimeter calibration using various beam test data will be discussed in an attempt to assess the uncertainties of the energy measurements.
[3]  oai:arXiv.org:0808.1718  [pdf] - 15339
Measurements of cosmic-ray secondary nuclei at high energies with the first flight of the CREAM balloon-borne experiment
Comments: Accepted for publication in Astroparticle Physics
Submitted: 2008-08-12
We present new measurements of heavy cosmic-ray nuclei at high energies per- formed during the first flight of the balloon-borne cosmic-ray experiment CREAM (Cosmic-Ray Energetics And Mass). This instrument uses multiple charge detectors and a transition radiation detector to provide the first high accuracy measurements of the relative abundances of elements from boron to oxygen up to energies around 1 TeV/n. The data agree with previous measurements at lower energies and show a relatively steep decline (~E$^-0.6$ to E$^-0.5$) at high energies. They further show the source abundance of nitrogen relative to oxygen is ~10% in the TeV/n region.
[4]  oai:arXiv.org:0801.3250  [pdf] - 1579278
The RICH detector of the AMS-02 experiment: status and physics prospects
Comments: 5 pages. Contribution to the 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications (Como 2007). Presenter: Rui Pereira
Submitted: 2008-01-21
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and with high energy photon detection capability up to a few hundred GeV. It is equipped with several subsystems, one of which is a proximity focusing RICH detector with a dual radiator (aerogel+NaF) that provides reliable measurements for particle velocity and charge. The assembly and testing of the AMS RICH is currently being finished and the full AMS detector is expected to be ready by the end of 2008. The RICH detector of AMS-02 is presented. Physics prospects are briefly discussed.
[5]  oai:arXiv.org:0709.2154  [pdf] - 4935
The AMS-RICH velocity and charge reconstruction
Comments: Contribution to the ICRC07, Merida, Mexico (2007); Presenter: F. Barao
Submitted: 2007-09-13
The AMS detector, to be installed on the International Space Station, includes a Ring Imaging Cerenkov detector with two different radiators, silica aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to provide very precise measurements of velocity and electric charge in a wide range of cosmic nuclei energies and atomic numbers. The detector geometry, in particular the presence of a reflector for acceptance purposes, leads to complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The results of different reconstruction methods applied to test beam data as well as to simulated samples are presented. To ensure nominal performances throughout the flight, several detector parameters have to be carefully monitored. The algorithms developed to fulfill these requirements are presented. The velocity and charge measurements provided by the RICH detector endow the AMS spectrometer with precise particle identification capabilities in a wide energy range. The expected performances on light isotope separation are discussed.