Normalized to: Malaspina, M.
[1]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[2]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[3]
oai:arXiv.org:1001.4661 [pdf] - 33165
Design, development, and verification of the Planck Low Frequency
Instrument 70 GHz Front-End and Back-End Modules
Varis, J.;
Hughes, N. J.;
Laaninen, M.;
Kilpia, V. -H.;
Jukkala, P.;
Tuovinen, J.;
Ovaska, S.;
Sjoman, P.;
Kangaslahti, P.;
Gaier, T.;
Hoyland, R.;
Meinhold, P.;
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
Franceschi, E.;
Leonardi, R.;
Leutenegger, P.;
Malaspina, M.;
Mandolesi, N.;
Miccolis, M.;
Poutanen, T.;
Kurki-Suonio, H.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.
Submitted: 2010-01-26
70 GHz radiometer front-end and back-end modules for the Low Frequency
Instrument of the European Space Agencys Planck Mission were built and tested.
The operating principles and the design details of the mechanical structures
are described along with the key InP MMIC low noise amplifiers and phase
switches of the units. The units were tested in specially designed cryogenic
vacuum chambers capable of producing the operating conditions required for
Planck radiometers, specifically, a physical temperature of 20 K for the
front-end modules, 300 K for the back-end modules and 4 K for the reference
signal sources. Test results of the low noise amplifiers and phase switches,
the front and back-end modules, and the combined results of both modules are
discussed.
At 70 GHz frequency, the system noise temperature of the front and back end
is 28 K; the effective bandwidth 16 GHz, and the 1/f spectrum knee frequency is
38 mHz. The test results indicate state-of-the-art performance at 70 GHz
frequency and fulfil the Planck performance requirements.
[4]
oai:arXiv.org:1001.4730 [pdf] - 33178
Level 1 on-ground telemetry handling in Planck LFI
Zacchei, A.;
Frailis, M.;
Maris, M.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Maino, D.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meinhold, P.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave
Background (CMB) by covering the frequency range 30-70 GHz in three bands. The
primary instrument data source are the temperature samples acquired by the 22
radiometers mounted on the Planck focal plane. Such samples represent the
scientific data of LFI. In addition, the LFI instrument generates the so called
housekeeping data by sampling regularly the on-board sensors and registers. The
housekeeping data provides information on the overall health status of the
instrument and on the scientific data quality. The scientific and housekeeping
data are collected on-board into telemetry packets compliant with the ESA
Packet Telemetry standards. They represent the primary input to the first
processing level of the LFI Data Processing Centre. In this work we show the
software systems which build the LFI Level 1. A real-time assessment system,
based on the ESA SCOS 2000 generic mission control system, has the main purpose
of monitoring the housekeeping parameters of LFI and detect possible anomalies.
A telemetry handler system processes the housekeeping and scientific telemetry
of LFI, generating timelines for each acquisition chain and each housekeeping
parameter. Such timelines represent the main input to the subsequent processing
levels of the LFI DPC. A telemetry quick-look system allows the real-time
visualization of the LFI scientific and housekeeping data, by also calculating
quick statistical functions and fast Fourier transforms. The LFI Level 1 has
been designed to support all the mission phases, from the instrument ground
tests and calibration to the flight operations, and developed according to the
ESA engineering standards.
[5]
oai:arXiv.org:1001.4787 [pdf] - 33194
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Malaspina, M.;
Franceschi, E.;
Battaglia, P.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gasparo, F.;
Gregorio, A.;
Lapolla, M.;
Leonardi, R.;
Maggio, G.;
Mandolesi, N.;
Manzato, P.;
Maris, M.;
Meharga, M.;
Meinhold, P.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Sandri, M.;
Tomasi, M.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST
(http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation
radiometers at 30, 44, and 70 GHz. Before integrating the overall array
assembly, a first set of tests has been performed for each radiometer chain
assembly (RCA), consisting of two radiometers. In this paper, we describe
Rachel, a software application which has been purposely developed and used
during the RCA test campaign to carry out both near-realtime on-line data
analysis and data storage (in FITS format) of the raw output from the
radiometric chains.
[6]
oai:arXiv.org:1001.4838 [pdf] - 33213
A systematic approach to the Planck LFI end-to-end test and its
application to the DPC Level 1 pipeline
Frailis, M.;
Maris, M.;
Zacchei, A.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Lowe, S. R.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the
handling of the scientific and housekeeping telemetry. It is a critical
component of the Planck ground segment which has to strictly commit to the
project schedule to be ready for the launch and flight operations. In order to
guarantee the quality necessary to achieve the objectives of the Planck
mission, the design and development of the Level 1 software has followed the
ESA Software Engineering Standards. A fundamental step in the software life
cycle is the Verification and Validation of the software. The purpose of this
work is to show an example of procedures, test development and analysis
successfully applied to a key software project of an ESA mission. We present
the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by
detailing the methods used and the results obtained. Different approaches have
been used to test the scientific and housekeeping data processing. Scientific
data processing has been tested by injecting signals with known properties
directly into the acquisition electronics, in order to generate a test dataset
of real telemetry data and reproduce as much as possible nominal conditions.
For the HK telemetry processing, validation software have been developed to
inject known parameter values into a set of real housekeeping packets and
perform a comparison with the corresponding timelines generated by the Level 1.
With the proposed validation and verification procedure, where the on-board and
ground processing are viewed as a single pipeline, we demonstrated that the
scientific and housekeeping processing of the Planck-LFI raw data is correct
and meets the project requirements.
[7]
oai:arXiv.org:1001.4608 [pdf] - 33147
Noise Properties of the Planck-LFI Receivers
Meinhold, P.;
Leonardi, R.;
Aja, B.;
Artal, E.;
Battaglia, P.;
Bersanelli, M.;
Blackhurst, E.;
Butler, C. R.;
Cuevas, L. P.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R.;
de la Fuente, M. L.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gregorio, A.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Leutenegger, P.;
Lowe, S. R.;
Malaspina, M.;
Mandolesi, R.;
Maris, M.;
Martínez-González, E.;
Mendes, L.;
Mennella, A.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Seiffert, M.;
Salmón, M.;
Stringhetti, L.;
Poutanen, T.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Varis, J.;
Valenziano, L.;
Villa, F.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) radiometers have been tested
extensively during several dedicated campaigns. The present paper reports the
principal noise properties of the LFI radiometers.
[8]
oai:arXiv.org:1001.4642 [pdf] - 33158
Off-line radiometric analysis of Planck/LFI data
Tomasi, M.;
Mennella, A.;
Galeotta, S.;
Lowe, S. R.;
Mendes, L.;
Leonardi, R.;
Villa, F.;
Cappellini, B.;
Gregorio, A.;
Meinhold, P.;
Sandri, M.;
Cuttaia, F.;
Terenzi, L.;
Maris, M.;
Valenziano, L.;
Salmon, M. J.;
Bersanelli, M.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschi, E.;
Gasparo, F.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Morgante, G.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) is an array of 22
pseudo-correlation radiometers on-board the Planck satellite to measure
temperature and polarization anisotropies in the Cosmic Microwave Background
(CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the
performances of the LFI, a software suite named LIFE has been developed. Its
aims are to provide a common platform to use for analyzing the results of the
tests performed on the single components of the instrument (RCAs, Radiometric
Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA).
Moreover, its analysis tools are designed to be used during the flight as well
to produce periodic reports on the status of the instrument. The LIFE suite has
been developed using a multi-layered, cross-platform approach. It implements a
number of analysis modules written in RSI IDL, each accessing the data through
a portable and heavily optimized library of functions written in C and C++. One
of the most important features of LIFE is its ability to run the same data
analysis codes both using ground test data and real flight data as input. The
LIFE software suite has been successfully used during the RCA/RAA tests and the
Planck Integrated System Tests. Moreover, the software has also passed the
verification for its in-flight use during the System Operations Verification
Tests, held in October 2008.
[9]
oai:arXiv.org:1001.4737 [pdf] - 1937606
Optimization of Planck/LFI on--board data handling
Maris, M.;
Tomasi, M.;
Galeotta, S.;
Miccolis, M.;
Hildebrandt, S.;
Frailis, M.;
Rohlfs, R.;
Morisset, N.;
Zacchei, A.;
Bersanelli, M.;
Binko, P.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
Chulani, H.;
D'Arcangelo, O.;
Fogliani, S.;
Franceschi, E.;
Gasparo, F.;
Gomez, F.;
Gregorio, A.;
Herreros, J. M.;
Leonardi, R.;
Leutenegger, P.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Meinhold, P.;
Mennella, A.;
Pasian, F.;
Perrotta, F.;
Rebolo, R.;
Turler, M.;
Zonca, A.
Submitted: 2010-01-26
To asses stability against 1/f noise, the Low Frequency Instrument (LFI)
onboard the Planck mission will acquire data at a rate much higher than the
data rate allowed by its telemetry bandwith of 35.5 kbps. The data are
processed by an onboard pipeline, followed onground by a reversing step. This
paper illustrates the LFI scientific onboard processing to fit the allowed
datarate. This is a lossy process tuned by using a set of 5 parameters Naver,
r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level
of distortion introduced by the onboard processing, EpsilonQ, as a function of
these parameters. It describes the method of optimizing the onboard processing
chain. The tuning procedure is based on a optimization algorithm applied to
unprocessed and uncompressed raw data provided either by simulations, prelaunch
tests or data taken from LFI operating in diagnostic mode. All the needed
optimization steps are performed by an automated tool, OCA2, which ends with
optimized parameters and produces a set of statistical indicators, among them
the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr =
2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup
the process an analytical model is developed that is able to extract most of
the relevant information on EpsilonQ and Cr as a function of the signal
statistics and the processing parameters. This model will be of interest for
the instrument data analysis. The method was applied during ground tests when
the instrument was operating in conditions representative of flight. Optimized
parameters were obtained and the performance has been verified, the required
data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of
3.8% of white noise rms well within the requirements.
[10]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[11]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[12]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[13]
oai:arXiv.org:astro-ph/0411412 [pdf] - 69011
The Planck Low Frequency Instrument
Mandolesi, N.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
De Rosa, A.;
Finelli, F.;
Franceschi, E.;
Gruppuso, A.;
Malaspina, M.;
Morgante, G.;
Morigi, G.;
Popa, L.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Valenziano, L.;
Villa, F.
Submitted: 2004-11-15
Planck is the third generation of mm-wave instruments designed for space
observations of the cosmic microwave background (CMB) anisotropies within the
new Cosmic Vision 2020 ESA Science Program. Planck will map the whole sky with
unprecedented sensitivity, angular resolution, and frequency coverage, and it
likely leads us to the final comprehension of the CMB anisotropies. The Low
Frequency Instrument (LFI), operating in the 30-70 GHz range, is one of the two
instruments onboard Planck satellite, sharing the focal region of a 1.5 meter
off-axis dual reflector telescope together with the High Frequency Instrument
(HFI) operating at 100-857 GHz. We present LFI and discuss the major
instrumental systematic effects that could degrade the measurements and the
solutions adopted in the design and data analysis phase in order to adequately
reduce and control them.
[14]
oai:arXiv.org:astro-ph/0304146 [pdf] - 56054
Planck Low Frequency Instrument: Beam Patterns
Sandri, M.;
Bersanelli, M.;
Burigana, C.;
Butler, R. C.;
Malaspina, M.;
Mandolesi, N.;
Mennella, A.;
Morgante, G.;
Terenzi, L.;
Valenziano, L.;
Villa, F.
Submitted: 2003-04-08
The Low Frequency Instrument on board the ESA Planck satellite is coupled to
the Planck 1.5 meter off-axis dual reflector telescope by an array of 27
corrugated feed horns operating at 30, 44, 70, and 100 GHz. We briefly present
here a detailed study of the optical interface devoted to optimize the angular
resolution (10 arcmin at 100 GHz as a goal) and at the same time to minimize
all the systematics coming from the sidelobes of the radiation pattern. Through
optical simulations, we provide shapes, locations on the sky, angular
resolutions, and polarization properties of each beam.
[15]
oai:arXiv.org:astro-ph/0302034 [pdf] - 54661
A Map of the Cosmic Microwave Background from the BEAST Experiment
Meinhold, Peter R.;
Bersanelli, Marco;
Childers, Jeffrey;
Figueiredo, Newton;
Gaier, Todd C.;
Halevi, Doron;
Lawrence, Charles R.;
Kangas, Miikka;
Levy, Alan;
Lubin, Philip M.;
Malaspina, Marco;
Mandolesi, Nazzareno;
Marvil, Joshua;
Mejia, Jorge;
Natoli, Paolo;
O'Dwyer, Ian;
O'Neill, Hugh;
Parendo, Shane;
Pina, Agenor;
Seiffert, Michael D.;
Stebor, Nathan C.;
Tello, Camilo;
Villa, Fabrizio;
Villela, Thyrso;
Wandelt, Benjamin D.;
Williams, Brian;
Wuensche, Carlos Alexandre
Submitted: 2003-02-03, last modified: 2003-03-02
We present the first sky maps from the BEAST (Background Emission Anisotropy
Scanning Telescope) experiment. BEAST consists of a 2.2 meter off axis
Gregorian telescope fed by a cryogenic millimeter wavelength focal plane
currently consisting of 6 Q band (40 GHz) and 2 Ka band (30 GHz) scalar feed
horns feeding cryogenic HEMT amplifiers. Data were collected from two
balloon-borne flights in 2000, followed by a lengthy ground observing campaign
from the 3.8 Km altitude University of California White Mountain Research
Station. This paper reports the initial results from the ground based
observations. The instrument produced an annular map covering the sky from
declinateion 33 to 42 degrees. The maps cover an area of 2470 square degrees
with an effective resolution of 23 arcminutes FWHM at 40 GHz and 30 arcminutes
at 30 GHz. The map RMS (smoothed to 30 arcminutes and excluding galactic
foregrounds) is 54 +-5 microK at 40 GHz. Comparison with the instrument noise
gives a cosmic signal RMS contribution of 28 +-3 microK. An estimate of the
actual CMB sky signal requires taking into account the l-space filter function
of our experiment and analysis techniques, carried out in a companion paper
(O'Dwyer et al. 2003). In addition to the robust detection of CMB anisotropies,
we find a strong correlation between small portions of our maps and features in
recent H$\alpha$ maps (Finkbeiner, 2003). In this work we describe the data set
and analysis techniques leading to the maps, including data selection,
filtering, pointing reconstruction, mapmaking algorithms and systematic
effects. A detailed description of the experiment appears in Childers et al.
(2003).
[16]
oai:arXiv.org:astro-ph/9906360 [pdf] - 107081
A preliminary study on destriping techniques of PLANCK/LFI measurements
versus observational strategy
Submitted: 1999-06-23
We present here the basic issues of our simulations of PLANCK/LFI
observations focussing on the study of the stripes generated by the 1/f noise,
including realistic estimates of the 1/f knee frequency, based on the Seiffert
et al. (1997) study of the properties of the PLANCK/LFI radiometers. The
destriping method presented in the report on the PLANCK PHASE A study has been
implemented to be applied to different scanning strategies with the freedom of
choosing more or less stringent crossing conditions. Numerical methods for
saving the amount of required RAM in the solution of the destriping linear
system are presented. We provide preliminary results of the efficiency of this
destriping technique for different scanning strategies. We focus here on
methodological aspects and remind the reader to the Maino et al. (1999) paper
(astro-ph/9906010) for further analyses and a more complete discussion.
[17]
oai:arXiv.org:astro-ph/9906010 [pdf] - 106731
The Planck-LFI instrument: analysis of the 1/f noise and implications
for the scanning strategy
Maino, D.;
Burigana, C.;
Maltoni, M.;
Wandelt, B. D.;
Gorski, K. M.;
Malaspina, M.;
Bersanelli, M.;
Mandolesi, N.;
Banday, A. J.;
Hivon, E.
Submitted: 1999-06-01
We study the impact of the 1/f noise on the PLANCK Low Frequency Instrument
(LFI) osbervations (Mandolesi et al 1998) and describe a simple method for
removing striping effects from the maps for a number of different scanning
stategies. A configuration with an angle between telescope optical axis and
spin-axis just less than 90 degrees (namely 85 degress) shows good destriping
efficiency for all receivers in the focal plane, with residual noise
degradation < 1-2 %. In this configuration, the full sky coverage can be
achieved for each channel separately with a 5 degrees spin-axis precession to
maintain a constant solar aspect angle.