Normalized to: Majewski, P.
[1]
oai:arXiv.org:1911.11755 [pdf] - 2091674
AION: An Atom Interferometer Observatory and Network
Badurina, L.;
Bentine, E.;
Blas, D.;
Bongs, K.;
Bortoletto, D.;
Bowcock, T.;
Bridges, K.;
Bowden, W.;
Buchmueller, O.;
Burrage, C.;
Coleman, J.;
Elertas, G.;
Ellis, J.;
Foot, C.;
Gibson, V.;
Haehnelt, M. G.;
Harte, T.;
Hedges, S.;
Hobson, R.;
Holynski, M.;
Jones, T.;
Langlois, M.;
Lellouch, S.;
Lewicki, M.;
Maiolino, R.;
Majewski, P.;
Malik, S.;
March-Russell, J.;
McCabe, C.;
Newbold, D.;
Sauer, B.;
Schneider, U.;
Shipsey, I.;
Singh, Y.;
Uchida, M. A.;
Valenzuela, T.;
van der Grinten, M.;
Vaskonen, V.;
Vossebeld, J.;
Weatherill, D.;
Wilmut, I.
Submitted: 2019-11-26, last modified: 2020-05-08
We outline the experimental concept and key scientific capabilities of AION
(Atom Interferometer Observatory and Network), a proposed UK-based experimental
programme using cold strontium atoms to search for ultra-light dark matter, to
explore gravitational waves in the mid-frequency range between the peak
sensitivities of the LISA and LIGO/Virgo/ KAGRA/INDIGO/Einstein
Telescope/Cosmic Explorer experiments, and to probe other frontiers in
fundamental physics. AION would complement other planned searches for dark
matter, as well as probe mergers involving intermediate mass black holes and
explore early universe cosmology. AION would share many technical features with
the MAGIS experimental programme in the US, and synergies would flow from
operating AION in a network with this experiment, as well as with other atom
interferometer experiments such as MIGA, ZAIGA and ELGAR. Operating AION in a
network with other gravitational wave detectors such as LIGO, Virgo and LISA
would also offer many synergies.
[2]
oai:arXiv.org:1802.06039 [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.;
Akerlof, C. W.;
Alsum, S. K.;
Araújo, H. M.;
Arthurs, M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Bauer, D.;
Belle, J.;
Beltrame, P.;
Benson, T.;
Bernard, E. P.;
Biesiadzinski, T. P.;
Boast, K. E.;
Boxer, B.;
Brás, P.;
Buckley, J. H.;
Bugaev, V. V.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Chan, C.;
Cherwinka, J. J.;
Cole, A.;
Cottle, A.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
Dahl, C. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, W. R.;
Fan, A.;
Fayer, S.;
Fiorucci, S.;
Fruth, T.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
van der Grinten, M. G. D.;
Hall, C. R.;
Hans, S.;
Hanzel, K.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hillbrand, S.;
Hjemfelt, C.;
Hoff, M. D.;
Hor, J. Y-K.;
Huang, D. Q.;
Ignarra, C. M.;
Ji, W.;
Kaboth, A. C.;
Kamdin, K.;
Keefner, J.;
Khaitan, D.;
Khazov, A.;
Kim, Y. D.;
Kocher, C. D.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kreczko, L.;
Krikler, B.;
Kudryavtsev, V. A.;
Kyre, S.;
Lee, J.;
Lenardo, B. G.;
Leonard, D. S.;
Lesko, K. T.;
Levy, C.;
Li, J.;
Liao, J.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Linehan, R.;
Lippincott, W. H.;
Liu, X.;
Lopes, M. I.;
Paredes, B. López;
Lorenzon, W.;
Luitz, S.;
Lyle, J. M.;
Majewski, P.;
Manalaysay, A.;
Mannino, R. L.;
Maupin, C.;
McKinsey, D. N.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Morrison, E.;
Mount, B. J.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikoleyczik, J.;
O'Sullivan, K.;
Olcina, I.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Patton, S. J.;
Pease, E. K.;
Penning, B.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Rhyne, C. A.;
Richards, A.;
Rodrigues, J. P.;
Rosero, R.;
Rossiter, P.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silk, J. J.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stancu, I.;
Stark, M. R.;
Stiegler, T. M.;
Stifter, K.;
Szydagis, M.;
Taylor, W. C.;
Taylor, R.;
Taylor, D. J.;
Temples, D.;
Terman, P. A.;
Thomas, K. J.;
Timalsina, M.;
To, W. H.;
Tomás, A.;
Tope, T. E.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Utku, U.;
Va'vra, J.;
Vacheret, A.;
Verbus, J. R.;
Voirin, E.;
Waldron, W. L.;
Watson, J. R.;
Webb, R. C.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, I.
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well
underway, LZ is on track for commissioning at SURF in 2020.
[4]
oai:arXiv.org:1902.04048 [pdf] - 1924972
Search for dark matter with a 231-day exposure of liquid argon using
DEAP-3600 at SNOLAB
Ajaj, R.;
Amaudruz, P. -A.;
Araujo, G. R.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Doria, L.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Gallacher, D.;
Garcés, E. A.;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Lidgard, J.;
Lindner, T.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-02-11, last modified: 2019-07-04
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter
experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The
detector consists of 3279 kg of LAr contained in a spherical acrylic vessel.
This paper reports on the analysis of a 758 tonne\cdot day exposure taken over
a period of 231 live-days during the first year of operation. No candidate
signal events are observed in the WIMP-search region of interest, which results
in the leading limit on the WIMP-nucleon spin-independent cross section on a
LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a
100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a
detailed background model, this analysis demonstrates the best pulse-shape
discrimination in LAr at threshold, employs a Bayesian photoelectron-counting
technique to improve the energy resolution and discrimination efficiency, and
utilizes two position reconstruction algorithms based on PMT charge and photon
arrival times.
[5]
oai:arXiv.org:1905.05811 [pdf] - 1994027
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600
Dark Matter Detector
Ajaj, R.;
Araujo, G. R.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cárdenas-Montes, M.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Dering, K.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Flower, A.;
Ford, R. J.;
Gallacher, D.;
Abia, P. García;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pesudo, V.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
García, E. Sanchez;
Santorelli, R.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-05-14
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne
single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB.
The experimental signature of dark matter interactions is keV-scale $^{40}$Ar
nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by
PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced
by $\beta$ and $\gamma$-rays originating from internal and external
radioactivity in the detector material. A background model of the ER
interactions in DEAP-3600 was developed and is described in this work. The
model is based on several components which are expected from radioisotopes in
the LAr, from ex-situ material assay measurements, and from dedicated
independent in-situ analyses. This prior information is used in a Bayesian fit
of the ER components to a 247.2 d dataset to model the radioactivity in the
surrounding detector materials. While excellent discrimination between ERs and
NRs is reached with pulse shape discrimination, utilizing the large difference
between fast and slow components of LAr scintillation light, detailed knowledge
of the ER background and activity of detector components, sets valuable
constraints on other key types of backgrounds in the detector: neutrons and
alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is
determined by measuring the daughter decay of $^{42}$K. This cosmogenically
activated trace isotope is a relevant background at higher energies for other
rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND.
The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm
5.9$ $\mu$Bq/kg of argon.
[6]
oai:arXiv.org:1707.08042 [pdf] - 1735166
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Collaboration, DEAP-3600;
:;
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Gulyev, E.;
Hakobyan, R.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Lidgard, J. J.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-07-25, last modified: 2018-08-13
This paper reports the first results of a direct dark matter search with the
DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was
performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target
mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg
capacity. The LAr is viewed by an array of PMTs, which would register
scintillation light produced by rare nuclear recoil signals induced by dark
matter particle scattering. An analysis of 4.44 live days (fiducial exposure of
9.87 tonne-days) of data taken with the nearly full detector during the initial
filling phase demonstrates the detector performance and the best electronic
recoil rejection using pulse-shape discrimination in argon, with leakage
$<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate
signal events are observed, which results in the leading limit on WIMP-nucleon
spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100
GeV/c$^2$ WIMP mass (90% C.L.).
[7]
oai:arXiv.org:1712.01982 [pdf] - 1832993
Design and Construction of the DEAP-3600 Dark Matter Detector
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Churchwell, S.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Gulyev, E.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
White, R.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-12-05, last modified: 2018-04-10
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has
been designed for a direct detection search for particle dark matter using a
single-phase liquid argon target. The projected cross section sensitivity for
DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$
WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the
physical properties and construction of the DEAP-3600 detector.
[9]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[10]
oai:arXiv.org:1410.7673 [pdf] - 1416317
DEAP-3600 Dark Matter Search
DEAP Collaboration;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Dering, K.;
DiGioseffo, J.;
Duncan, F.;
Flower, T.;
Ford, R.;
Giampa, P.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Guliyev, E.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Liimatainen, P.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2014-10-27, last modified: 2015-08-25
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury,
Ontario. It is a single-phase detector that searches for dark matter particle
interactions within a 1000-kg fiducial mass target of liquid argon. A first
generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass
demonstrated a high level of pulse-shape discrimination (PSD) for reducing
$\beta$/$\gamma$ backgrounds and helped to develop low radioactivity techniques
to mitigate surface-related $\alpha$ backgrounds. Construction of the DEAP-3600
detector is nearly complete and commissioning is starting in 2014. The target
sensitivity to spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of
magnitude improvement in sensitivity over current searches at 100 GeV WIMP
mass. This paper presents an overview and status of the DEAP-3600 project and
discusses plans for a future multi-tonne experiment, DEAP-50T.
[11]
oai:arXiv.org:1112.1481 [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Solovov, V. N.;
Belov, V. A.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.
[12]
oai:arXiv.org:1110.4769 [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of
ZEPLIN-III
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Bewick, A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Jones, W. G.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach.
[13]
oai:arXiv.org:1111.2248 [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic
Scintillator
Reichhart, L.;
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.
[14]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[15]
oai:arXiv.org:1106.0808 [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Neves, F.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Rodrigues, S.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from
the ZEPLIN-III dark matter experiment and its reduction into a set of
parameters used in all subsequent analyses. The detector is a liquid xenon time
projection chamber with scintillation and electroluminescence signals read out
by an array of 31 photomultipliers. The dual range 62-channel data stream is
optimised for the detection of scintillation pulses down to a single
photoelectron and of ionisation signals as small as those produced by single
electrons. We discuss in particular several strategies related to data
filtering, pulse finding and pulse clustering which are tuned to recover the
best electron/nuclear recoil discrimination near the detection threshold, where
most dark matter elastic scattering signatures are expected. The software was
designed assuming only minimal knowledge of the physics underlying the
detection principle, allowing an unbiased analysis of the experimental results
and easy extension to other detectors with similar requirements.
[16]
oai:arXiv.org:1103.0393 [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III
experiment
Ghag, C.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Lyons, K.;
Majewski, P.;
St, A.;
Murphy, J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby
Underground Laboratory in search of dark matter WIMPs. The major upgrades to
the instrument over its first science run include lower background
photomultiplier tubes and installation of a plastic scintillator veto system.
Performance results from the veto detector using calibration and science data
in its first six months of operation in coincidence with ZEPLIN-III are
presented. With fully automated operation and calibration, the veto system has
maintained high stability and achieves near unity live time relative to
ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60%
of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be
misidentified as WIMPs. This tagging efficiency reduces the expected untagged
nuclear recoil background from neutrons during science data taking to a very
low rate of ~0.2 events per year in the WIMP acceptance region. Additionally,
the veto detector provides rejection of 28% of gamma-ray induced background
events, allowing the sampling of the dominant source of background in
ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will
not be tagged by the veto detector, and tags due to gamma-rays and neutrons are
separable, this population of multiple scatter events may be characterised
without biasing the analysis of candidate WIMP signals in the data.
[17]
oai:arXiv.org:1004.4207 [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Lyons, K.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Taylor, R.;
Thorne, C.;
Walker, R. J.
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto
detector to complement the ZEPLIN-III direct dark matter search instrument is
described. One tonne of plastic scintillator is arranged into 52 bars
individually read out by photomultipliers and coupled to a gadolinium-loaded
passive polypropylene shield. Particular attention has been paid to
radiological content. The overall aim has been to achieve a veto detector of
low threshold and high efficiency without the creation of additional background
in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of
the components have been made, including radioactivity levels and performance
characteristics. These have been used to inform a complete end-to-end Monte
Carlo simulation that has then been used to calculate the expected performance
of the new instrument, both operating alone and as an anti-coincidence detector
for ZEPLIN-III. The veto device will be capable of rejecting over 65% of
coincident nuclear recoil events from neutron background in the energy range of
interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4
to ~0.14 events per year in the WIMP acceptance region, a significant factor in
the event of a non-zero observation. Furthermore, in addition to providing
valuable diagnostic capabilities, the veto is capable of tagging over 15% for
gamma-ray rejection, all whilst contributing no significant additional
background. In conjunction with the replacement of the internal ZEPLIN-III
photomultiplier array, the new veto is expected to improve significantly the
sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin
independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
[18]
oai:arXiv.org:0812.1150 [pdf] - 19200
Results from the First Science Run of the ZEPLIN-III Dark Matter Search
Experiment
Lebedenko, V. N.;
Araujo, H. M.;
Barnes, E. J.;
Bewick, A.;
Cashmore, R.;
Chepel, V.;
Currie, A.;
Davidge, D.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Ghag, C.;
Horn, M.;
Howard, A. S.;
Hughes, A. J.;
Jones, W. G.;
Joshi, M.;
Kalmus, G. E.;
Kovalenko, A. G.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2008-12-05, last modified: 2009-09-02
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses
a 12kg two-phase xenon time projection chamber to search for the weakly
interacting massive particles (WIMPs) that may account for the dark matter of
our Galaxy. The detector measures both scintillation and ionisation produced by
radiation interacting in the liquid to differentiate between the nuclear
recoils expected from WIMPs and the electron recoil background signals down to
~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired
between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon
elastic scattering spin-independent cross-section above 8.1x10(-8)pb at
55GeV/c2 with a 90% confidence limit. It has also demonstrated that the
two-phase xenon technique is capable of better discrimination between electron
and nuclear recoils at low-energy than previously achieved by other xenon-based
experiments.
[19]
oai:arXiv.org:0809.1831 [pdf] - 16182
First measurement of the Head-Tail directional nuclear recoil signature
at energies relevant to WIMP dark matter searches
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. StJ.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-09-10
We present first evidence for the so-called Head-Tail asymmetry signature of
neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the
1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils
induced by Weakly Interacting Massive Particle (WIMPs) but one where the
differential ionization is poorly understood. We show that the distribution of
recoil energies and directions induced here by Cf-252 neutrons matches well
that expected from massive WIMPs. The results open a powerful new means of
searching for a galactic signature from WIMPs.
[20]
oai:arXiv.org:0807.3969 [pdf] - 14845
Measurement of the Range Component Directional Signature in a DRIFT-II
Detector using 252Cf Neutrons
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. St. J.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-07-24
The DRIFT collaboration utilizes low pressure gaseous detectors to search for
WIMP dark matter with directional signatures. A 252Cf neutron source was placed
on each of the principal axes of a DRIFT detector in order to test its ability
to measure directional signatures from the three components of very low energy
(~keV/amu) recoil ranges. A high trigger threshold and the event selection
procedure ensured that only sulfur recoils were analyzed. Sulfur recoils
produced in the CS2 target gas by the 252Cf source closely match those expected
from massive WIMP induced sulfur recoils. For each orientation of the source a
directional signal from the range components was observed, indicating that the
detector is directional along all 3 axes. An analysis of these results yields
an optimal orientation for DRIFT detectors when searching for a directional
signature from WIMPs. Additional energy dependent information is provided to
aid in understanding this effect.
[21]
oai:arXiv.org:0705.2117 [pdf] - 1279
R & D for Future Zeplin
Bisset, R.;
Carson, M. J.;
Chagani, H.;
Cline, D. B.;
Daw, E. J.;
Ferbel, T.;
Gao, J.;
Gao, Y. S.;
Kudryavtsev, V. A.;
Lightfoot, P. K.;
Majewski, P.;
Maxin, J.;
Miller, J.;
Ooi, W. C.;
Robinson, M.;
Salinas, G.;
Schroeder, U.;
Seifert, J.;
Sergiampietri, F.;
Skulski, W.;
Smith, P. F.;
Spooner, N. J. C.;
Toke, J.;
Wang, H.;
White, J. T.;
Wolfs, F.;
Yang, X.
Submitted: 2007-05-15
We propose a new concept for a very low background multi-ton liquid xenon
Dark Matter experiment. The detector consists of two concentric spheres and a
charge readout device in the centre. Xenon between the two spheres forms a
self-shield and veto device. The inner surface of the central sphere is coated
with CsI to form an internal photocathode with minimum of 2\pi coverage for any
event in the active volume. Photoelectrons from the CsI photocathode drift
toward the charge readout micro-structure in the centre of the detector. Both
scintillation and ionisation are measured simultaneously for background
rejection and 3-D event mapping. In addition to external shielding, the low
background is achieved by eliminating PMTs and by using low radioactivity pure
materials throughout the detector. We present detailed calculations of the
charge readout system and design details. The detector is expected to probe the
full SUSY parameter space.
[22]
oai:arXiv.org:0704.1118 [pdf] - 231
Observation of Anti-correlation between Scintillation and Ionization for
MeV Gamma-Rays in Liquid Xenon
Submitted: 2007-04-09
A strong anti-correlation between ionization and scintillation signals
produced by MeV gamma-rays in liquid xenon has been measured and used to
improve the energy resolution by combining the two signals. The improvement is
explained by reduced electron-ion recombination fluctuations of the combined
signal compared to fluctuations of the individual signals. Simultaneous
measurements of ionization and scintillation signals were carried out with
Cs-137, Na-22 and Co-60 gamma rays, as a function of electric field in the
liquid. A resolution of 1.7%(sigma) at 662 keV was measured at 1 kV/cm,
significantly better than the resolution from either scintillation or
ionization alone. A detailed analysis indicates that further improvement to
less than 1%(sigma) is possible with higher light collection efficiency and
lower electronic noise.
[23]
oai:arXiv.org:astro-ph/0701858 [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase
xenon detector for dark matter detection
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Cashmore, R. J.;
Chagani, H.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Gao, J.;
Ghag, C.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Korolkova, E. V.;
Kudryavtsev, V. A.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Neves, F.;
Nicklin, G. G.;
Ooi, W.;
Paling, S. M.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R. M.;
Quenby, J. J.;
Robinson, M.;
Sergiampietri, F.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F. L. H.
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[24]
oai:arXiv.org:physics/0608034 [pdf] - 119179
Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
Submitted: 2006-08-03, last modified: 2006-08-04
Scintillation light from gamma ray irradiation in liquid xenon is detected by
two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV
light reflector material, PTFE, is used to optimize the light collection
efficiency. The detector gives a high light yield of 6 photoelectron per keV
(pe/keV), which allows efficient detection of the 122 keV gamma-ray line from
Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best
achievable energy resolution, by removing the instrumental fluctuations, from
liquid xenon scintillation light is estimated to be around 6-8% (sigma) for
gamma-ray with energy between 662 keV and 122 keV.
[25]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
[26]
oai:arXiv.org:astro-ph/0601552 [pdf] - 79410
Simultaneous Measurement of Ionization and Scintillation from Nuclear
Recoils in Liquid Xenon as Target for a Dark Matter Experiment
Aprile, E.;
Dahl, C. E.;
DeViveiros, L.;
Gaitskell, R.;
Giboni, K. L.;
Kwong, J.;
Majewski, P.;
Ni, K.;
Shutt, T.;
Yamashita, M.
Submitted: 2006-01-24
We report the first measurements of the absolute ionization yield of nuclear
recoils in liquid xenon, as a function of energy and electric-field.
Independent experiments were carried out with two dual-phase time projection
chamber prototypes, developed for the XENON Dark Matter project. We find that
the charge yield increases with decreasing recoil energy, and exhibits only a
weak field dependence. These results are a first demonstration of the
capability of dual phase xenon detectors to discriminate between electron and
nuclear recoils, a key requirement for a sensitive dark matter search at recoil
energies down to 20 keV.
[27]
oai:arXiv.org:astro-ph/0503621 [pdf] - 72003
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Submitted: 2005-03-29
Liquid Xenon (LXe) is expected to be an excellent target and detector medium
to search for dark matter in the form of Weakly Interacting Massive Particles
(WIMPs). Knowledge of LXe ionization and scintillation response to low energy
nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important
for determining the sensitivity of LXe direct detection experiments. Here we
report on new measurements of the scintillation yield of Xe recoils with
kinetic energy as low as 10 keV. The dependence of the scintillation yield on
applied electric field was also measured in the range of 0 to 4 kV/cm. Results
are in good agreement with recent theoretical predictions that take into
account the effect of biexcitonic collisions in addition to the nuclear
quenching effect.
[28]
oai:arXiv.org:physics/0502071 [pdf] - 119079
Performance of a Large Area Avalanche Photodiode in a Liquid Xenon
Ionization and Scintillation Chamber
Submitted: 2005-02-14
Scintillation light produced in liquid xenon (LXe) by alpha particles,
electrons and gamma-rays was detected with a large area avalanche photodiode
(LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a
function of applied electric field. We estimate the quantum efficiency of the
LAAPD to be 45%. The best energy resolution from the light measurement at zero
electric field is 7.5%(sigma) for 976 keV internal conversion electrons from
Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector
used for these measurements was also operated as a gridded ionization chamber
to measure the charge yield. We confirm that using a LAAPD in LXe does not
introduce impurities which inhibit the drifting of free electrons.
[29]
oai:arXiv.org:astro-ph/0407575 [pdf] - 66417
The XENON Dark Matter Search Experiment
Aprile, E.;
Giboni, K. L.;
Majewski, P.;
Ni, K.;
Yamashita, M.;
Gaitskell, R.;
Sorensen, P.;
DeViveiros, L.;
Baudis, L.;
Bernstein, A.;
Hagmann, C.;
Winant, C.;
Shutt, T.;
Kwong, J.;
Oberlack, U.;
McKinsey, D.;
Hasty, R.
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form
of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering
off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent
liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest
interaction cross section predicted by SUSY models. The TPCs are operated in
dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to
16keV energy, via simultaneous detection of the ionization, through secondary
scintillation in the gas, and primary scintillation in the liquid. Thedistinct
ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or
neutrons), and for electron recoils from background, iskey to the
event-by-event discrimination capability of XENON. A dual phase xenon prototype
has been realized and is currently being tested, along with otherprototypes
dedicated to other measurements relevant to the XENON program. As part of the
R&D phase, we will realize and move underground a first XENON module (XENON10)
with at least 10 kg fiducial mass to measure the background rejection
capability and to optimize the conditions for continuous and stable detector
operation underground. We present some of the results from the ongoing R&D and
summarize the expected performance of the 10 kg experiment, from MonteCarlo
simulations. The main design features of the 100 kg detector unit(XENON100),
with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will
also be presented.
[30]
oai:arXiv.org:astro-ph/0304405 [pdf] - 56313
The Optical Emission from Gamma-ray Quasars
Submitted: 2003-04-22, last modified: 2003-05-01
We present photometric observations of six radio-loud quasars that were
detected by the COMPTEL gamma-ray telescope. The data encompasses seven
wavebands in the optical and near-infrared. After correction for Galactic
extinction, we find a wide range in optical slopes. Two sources are as blue as
optically-selected quasars, and are likely to be dominated by the accretion
disc emission, while three others show colours consistent with a red
synchrotron component. We discuss the properties of the COMPTEL sample of
quasars, as well as the implications our observations have for multi-wavelength
modelling of gamma-ray quasars.