Mahashabde, Sumedh
Normalized to: Mahashabde, S.
3 article(s) in total. 8 co-authors, from 1 to 3 common article(s). Median position in authors list is 3,0.
[1]
oai:arXiv.org:1505.02618 [pdf] - 996791
A Frequency Selective Surface based focal plane receiver for the OLIMPO
balloon-borne telescope
Submitted: 2015-05-11
We describe here a focal plane array of Cold-Electron Bolometer (CEB)
detectors integrated in a Frequency Selective Surface (FSS) for the 350 GHz
detection band of the OLIMPO balloon-borne telescope. In our architecture, the
two terminal CEB has been integrated in the periodic unit cell of the FSS
structure and is impedance matched to the embedding impedance seen by it and
provides a resonant interaction with the incident sub-mm radiation. The
detector array has been designed to operate in background noise limited
condition for incident powers of 20 pW to 80 pW, making it possible to use the
same pixel in both photometric and spectrometric configurations. We present
high frequency and dc simulations of our system, together with fabrication
details. The frequency response of the FSS array, optical response measurements
with hot/cold load in front of optical window and with variable temperature
black body source inside cryostat are presented. A comparison of the optical
response to the CEB model and estimations of Noise Equivalent power (NEP) is
also presented.
[2]
oai:arXiv.org:1410.5870 [pdf] - 886482
Cold-electron bolometers for future mm and sub-mm sky surveys
Submitted: 2014-10-21
Future sky surveys in the mm/sub-mm range, like the forthcoming balloon-borne
missions LSPE, OLIMPO, SPIDER etc., will need detectors insensitive to cosmic
rays (CRs) and with a NEP of the order of $10^{-17} \div 10^{-18}\,$W/sqrt(Hz).
The Cold-Electron Bolometers (CEBs) technology is promising, having the
required properties, since the absorber volume is extremely small and the
electron system of the absorber is thermally insulated from the phonon system.
We have developed an experimental setup to test the optical performance and the
CRs insensitivity of CEBs, with the target of integrating them in the OLIMPO
and LSPE focal planes.
[3]
oai:arXiv.org:1403.7779 [pdf] - 804121
Sensitivity to Cosmic Rays of Cold Electron Bolometers for Space
Applications
Submitted: 2014-03-30
An important phenomenon limiting the sensitivity of bolometric detectors for
future space missions is the interaction with cosmic rays. We tested the
sensitivity of Cold Electron Bolometers (CEBs) to ionizing radiation using
gamma-rays from a radioactive source and X-rays from a X-ray tube. We describe
the test setup and the results. As expected, due to the effective thermal
insulation of the sensing element and its negligible volume, we find that CEBs
are largely immune to this problem.