oai:arXiv.org:1808.07853 [pdf] - 1738019
The infrared imaging spectrograph (IRIS) for TMT: electronics-cable
architecture
Submitted: 2018-08-23
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the
Thirty Meter Telescope (TMT). It combines a diffraction limited imager and an
integral field spectrograph. This paper focuses on the electrical system of
IRIS. With an instrument of the size and complexity of IRIS we face several
electrical challenges. Many of the major controllers must be located directly
on the cryostat to reduce cable lengths, and others require multiple bulkheads
and must pass through a large cable wrap. Cooling and vibration due to the
rotation of the instrument are also major challenges. We will present our
selection of cables and connectors for both room temperature and cryogenic
environments, packaging in the various cabinets and enclosures, and techniques
for complex bulkheads including for large detectors at the cryostat wall.
[2]
oai:arXiv.org:1808.06024 [pdf] - 1735547
An overview of the NIRSPEC upgrade for the Keck II telescope
Martin, Emily C.;
Fitzgerald, Michael P.;
McLean, Ian S.;
Doppmann, Gregory;
Kassis, Marc;
Aliado, Ted;
Canfield, John;
Johnson, Chris;
Kress, Evan;
Lanclos, Kyle;
Magnone, Kenneth;
Sohn, Ji Man;
Wang, Eric;
Weiss, Jason
Submitted: 2018-08-17
NIRSPEC is a 1-5 micron echelle spectrograph in use on the Keck II Telescope
since 1999. The spectrograph is capable of both moderate (R~2,000) and high
(R~25,000) resolution observations and has been a workhorse instrument across
many astronomical fields, from planetary science to extragalactic observations.
In the latter half of 2018, we will upgrade NIRSPEC to improve the sensitivity
and stability of the instrument and increase its lifetime. The major components
of the upgrade include replacing the spectrometer and slit-viewing camera
detectors with Teledyne H2RG arrays and replacing all transputer-based
electronics. We present detailed design, testing, and analysis of the upgraded
instrument, including the finalized optomechanical design of the new 1-5 micron
slit-viewing camera, final alignment and assembly of the science array,
electronics systems, and updated software design.
[3]
oai:arXiv.org:1407.2314 [pdf] - 1215533
The Integral Field Spectrograph for the Gemini Planet Imager
Larkin, James E.;
Chilcote, Jeffrey K.;
Aliado, Theodore;
Bauman, Brian J.;
Brims, George;
Canfield, John M.;
Cardwell, Andrew;
Dillon, Daren;
Doyon, René;
Dunn, Jennifer;
Fitzgerald, Michael P.;
Graham, James R.;
Goodsell, Stephen;
Hartung, Markus;
Hibon, Pascale;
Ingraham, Patrick;
Johnson, Christopher A;
Kress, Evan;
Konopacky, Quinn M.;
Macintosh, Bruce A.;
Magnone, Kenneth G.;
Maire, Jérôme;
McLean, Ian S.;
Palmer, David;
Perrin, Marshall D.;
Quiroz, Carlos;
Rantakyrö, Fredrik;
Sadakuni, Naru;
Saddlemyer, Leslie;
Serio, Andrew;
Thibault, Simon;
Thomas, Sandrine J.;
Vallee, Philippe;
Weiss, Jason L.
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is a complex optical system designed to
directly detect the self-emission of young planets within two arcseconds of
their host stars. After suppressing the starlight with an advanced AO system
and apodized coronagraph, the dominant residual contamination in the focal
plane are speckles from the atmosphere and optical surfaces. Since speckles are
diffractive in nature their positions in the field are strongly wavelength
dependent, while an actual companion planet will remain at fixed separation. By
comparing multiple images at different wavelengths taken simultaneously, we can
freeze the speckle pattern and extract the planet light adding an order of
magnitude of contrast. To achieve a bandpass of 20%, sufficient to perform
speckle suppression, and to observe the entire two arcsecond field of view at
diffraction limited sampling, we designed and built an integral field
spectrograph with extremely low wavefront error and almost no chromatic
aberration. The spectrograph is fully cryogenic and operates in the wavelength
range 1 to 2.4 microns with five selectable filters. A prism is used to produce
a spectral resolution of 45 in the primary detection band and maintain high
throughput. Based on the OSIRIS spectrograph at Keck, we selected to use a
lenslet-based spectrograph to achieve an rms wavefront error of approximately
25 nm. Over 36,000 spectra are taken simultaneously and reassembled into image
cubes that have roughly 192x192 spatial elements and contain between 11 and 20
spectral channels. The primary dispersion prism can be replaced with a
Wollaston prism for dual polarization measurements. The spectrograph also has a
pupil-viewing mode for alignment and calibration.