sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

MacLachlan, David G.

Normalized to: MacLachlan, D.

7 article(s) in total. 25 co-authors, from 1 to 7 common article(s). Median position in authors list is 3,0.

[1]  oai:arXiv.org:2001.09211  [pdf] - 2037607
Modal noise mitigation for high-precision spectroscopy using a photonic reformatter
Comments: 13 pages, 9 figures (including appendix)
Submitted: 2020-01-24
Recently, we demonstrated how an astrophotonic light reformatting device, based on a multicore fibre photonic lantern and a three-dimensional waveguide component, can be used to efficiently reformat the point spread function of a telescope to a diffraction-limited psuedo-slit [arXiv:1512.07309]. Here, we demonstrate how such a device can also efficiently mitigate modal noise -- a potential source of instability in high resolution multi-mode fibre-fed spectrographs). To investigate the modal noise performance of the photonic reformatter, we have used it to feed light into a bench-top near-infrared spectrograph (R {\approx} 9,500, {\lambda} {\approx} 1550 nm). One approach to quantifying the modal noise involved the use of broadband excitation light and a statistical analysis of how the overall measured spectrum was affected by variations in the input coupling conditions. This approach indicated that the photonic reformatter could reduce modal noise by a factor of six when compared to a multi-mode fibre with a similar number of guided modes. Another approach to quantifying the modal noise involved the use of multiple spectrally narrow lines, and an analysis of how the measured barycentres of these lines were affected by variations in the input coupling. Using this approach, the photonic reformatter was observed to suppress modal noise to the level necessary to obtain spectra with stability close to that observed when using a single mode fibre feed. These results demonstrate the potential of using photonic reformatters to enable efficient multi-mode spectrographs that operate at the diffraction limit and are free of modal noise, with potential applications including radial velocity measurements of M-dwarfs.
[2]  oai:arXiv.org:1807.06372  [pdf] - 1717341
Optimizing astrophotonic spatial reformatters using simulated on-sky performance
Comments: Conference proceedings in SPIE 2018 Austin Texas
Submitted: 2018-07-17
One of the most useful techniques in astronomical instrumentation is image slicing. It enables a spectrograph to have a more compact angular slit, whilst retaining throughput and increasing resolving power. Astrophotonic components like the photonic lanterns and photonic reformatters can be used to replace bulk optics used so far. This study investigates the performance of such devices using end-to-end simulations to approximate realistic on-sky conditions. It investigates existing components, tries to optimize their performance and aims to understand better how best to design instruments to maximize their performance. This work complements the recent work in the field and provides an estimation for the performance of the new components.
[3]  oai:arXiv.org:1805.00665  [pdf] - 1698190
Simulation and Optimization of an Astrophotonic Reformatter
Comments:
Submitted: 2018-05-02
Image slicing is a powerful technique in astronomy. It allows the instrument designer to reduce the slit width of the spectrograph, increasing spectral resolving power whilst retaining throughput. Conventionally this is done using bulk optics, such as mirrors and prisms, however more recently astrophotonic components known as photonic lanterns (PLs) and photonic reformatters have also been used. These devices reformat the multi-mode (MM) input light from a telescope into single-mode (SM) outputs, which can then be re-arranged to suit the spectrograph. The photonic dicer (PD) is one such device, designed to reduce the dependence of spectrograph size on telescope aperture and eliminate modal noise. We simulate the PD, by optimising the throughput and geometrical design using Soapy and BeamProp. The simulated device shows a transmission between 8 and 20 %, depending upon the type of adaptive optics (AO) correction applied, matching the experimental results well. We also investigate our idealised model of the PD and show that the barycentre of the slit varies only slightly with time, meaning that the modal noise contribution is very low when compared to conventional fibre systems. We further optimise our model device for both higher throughput and reduced modal noise. This device improves throughput by 6.4 % and reduces the movement of the slit output by 50%, further improving stability. This shows the importance of properly simulating such devices, including atmospheric effects. Our work complements recent work in the field and is essential for optimising future photonic reformatters.
[4]  oai:arXiv.org:1607.08424  [pdf] - 1445854
Performance estimates for spectrographs using photonic reformatters
Comments: 8 Pages, 3 figures, Proc. SPIE. in 9912, Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation II, 99125Q (July 22, 2016)
Submitted: 2016-07-28
Using a photonic reformatter to eliminate the effects of conventional modal noise could greatly improve the stability of a high resolution spectrograph. However the regimes where this advantage becomes clear are not yet defined. Here we will look at where modal noise becomes a problem in conventional high resolution spectroscopy and what impact photonic spectrographs could have. We will theoretically derive achievable radial velocity measurements to compare photonic instruments and conventional ones. We will discuss the theoretical and experimental investigations that will need to be undertaken to optimize and prove the photonic reformatting concept.
[5]  oai:arXiv.org:1607.03363  [pdf] - 1528109
Modal noise characterisation of a hybrid reformatter
Comments: 9 pages, 9 figures, submitted to SPIE Astronomical Telescopes & Instrumentation 2016 (9912-78)
Submitted: 2016-07-11
This paper reports on the modal noise characterisation of a hybrid reformatter. The device consists of a multicore-fibre photonic lantern and an ultrafast laser-inscribed slit reformatter. It operates around 1550 nm and supports 92 modes. Photonic lanterns transform a multimode signal into an array of single-mode signals, and thus combine the high coupling efficiency of multimode fibres with the diffraction-limited performance of single-mode fibres. This paper presents experimental measurements of the device point spread function properties under different coupling conditions, and its throughput behaviour at high spectral resolution. The device demonstrates excellent scrambling but its point spread function is not completely stable. Mode field diameter and mode barycentre position at the device output vary as the multicore-fibre is agitated due to the fabrication imperfections.
[6]  oai:arXiv.org:1512.07309  [pdf] - 1494646
Efficient photonic reformatting of celestial light for diffraction-limited spectroscopy
Comments: 8 pages, 4 figures
Submitted: 2015-12-22
The spectral resolution of a dispersive astronomical spectrograph is limited by the trade-off between throughput and the width of the entrance slit. Photonic guided-wave transitions have been proposed as a route to bypass this trade-off, by enabling the efficient reformatting of incoherent seeing-limited light collected by the telescope into a linear array of single modes: a pseudo-slit which is highly multimode in one axis but diffraction-limited in the dispersion axis of the spectrograph. It is anticipated that the size of a single-object spectrograph fed with light in this manner would be essentially independent of the telescope aperture size. A further anticipated benefit is that such spectrographs would be free of `modal noise', a phenomenon that occurs in high-resolution multimode fibre-fed spectrographs due to the coherent nature of the telescope point-spread-function (PSF). We address these aspects by integrating a multicore fibre photonic lantern with an ultrafast laser inscribed three-dimensional waveguide interconnect to spatially reformat the modes within the PSF into a diffraction-limited pseudo-slit. Using the CANARY adaptive optics (AO) demonstrator on the William Herschel Telescope, and 1530 $\pm$ 80 nm stellar light, the device is found to exhibit a transmission of 47-53 % depending upon the mode of AO correction applied. We also show the advantage of using AO to couple light into such a device by sampling only the core of the CANARY PSF. This result underscores the possibility that a fully-optimised guided-wave device can be used with AO to provide efficient spectroscopy at high spectral resolution.
[7]  oai:arXiv.org:1402.2547  [pdf] - 1126160
Photonic spatial reformatting of stellar light for diffraction-limited spectroscopy
Comments: 8 pages, 6 figures
Submitted: 2014-02-11, last modified: 2015-06-08
The spectral resolution of a dispersive spectrograph is dependent on the width of the entrance slit. This means that astronomical spectrographs trade-off throughput with spectral resolving power. Recently, optical guided-wave transitions known as photonic lanterns have been proposed to circumvent this trade-off, by enabling the efficient reformatting of multimode light into a pseudo-slit which is highly multimode in one axis, but diffraction-limited in the other. Here, we demonstrate the successful reformatting of a telescope point spread function into such a slit using a three-dimensional integrated optical waveguide device, which we name the photonic dicer. Using the CANARY adaptive optics demonstrator on the William Herschel Telescope, and light centred at 1530 nm with a 160 nm FWHM, the device shows a transmission of between 10 and 20\% depending upon the type of AO correction applied. Most of the loss is due to the overfilling of the input aperture in poor and moderate seeing. Taking this into account, the photonic device itself has a transmission of 57 $\pm$ 4\%.We show how a fully-optimised device can be used with AO to provide efficient spectroscopy at high spectral resolution.