sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Macculi, C.

Normalized to: Macculi, C.

25 article(s) in total. 345 co-authors, from 1 to 18 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:2003.07295  [pdf] - 2077065
Soft proton scattering at grazing incidence from X-ray mirrors: analysis of experimental data in the framework of the non-elastic approximation
Comments:
Submitted: 2020-03-16
Astronomical X-ray observatories with grazing incidence optics face the problem of pseudo-focusing of low energy protons from the mirrors towards the focal plane. Those protons constitute a variable, unpredictable component of the non X-ray background that strongly affects astronomical observations and a correct estimation of their flux at the focal plane is then essential. For this reason, we investigate how they are scattered from the mirror surfaces when impacting with grazing angles. We compare the non-elastic model of reflectivity of particles at grazing incidence proposed by Remizovich et al. (1980) with the few available experimental measurements of proton scattering from X-ray mirrors. We develop a semi-empirical analytical model based on the fit of those experimental data with the Remizovich solution. We conclude that the scattering probability weakly depends on the energy of the impinging protons and that the relative energy losses are necessary to correctly model the data. The model we propose assumes no dependence on the incident energy and can be implemented in particle transport simulation codes to generate, for instance, proton response matrices for specific X-ray missions. Further laboratory measurements at lower energies and on other mirror samples, such as ATHENA Silicon Pore Optics, will improve the resolution of the model and will allow us to build the proper proton response matrices for a wider sample of X-ray observatories.
[2]  oai:arXiv.org:2001.11646  [pdf] - 2065397
Thermal simulations of temperature excursions on the Athena X-IFU detector wafer from impacts by cosmic rays
Comments: accepted for publication in the Journal of Low Temperature Physics
Submitted: 2020-01-30
We present the design and implementation of a thermal model, developed in COMSOL, aiming to probe the wafer-scale thermal response arising from realistic rates and energies of cosmic rays at L2 impacting the detector wafer of Athena X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and 2 layers represent the Au metallization layer's phonon and electron temperatures. We base the simulation geometry on the current specifications for the X-IFU detector wafer, and simulate cosmic ray impacts using a simple power injection into the Si bulk. We measure the temperature at the point of the instrument's most central TES detector. By probing the response of the system and pulse characteristics as a function of the thermal input energy and location, we reconstruct cosmic ray pulses in Python. By utilizing this code, along with the results of the GEANT4 simulations produced for X-IFU, we produce realistic time-ordered data (TOD) of the temperature seen by the central TES, which we use to simulate the degradation of the energy resolution of the instrument in space-like conditions on this wafer. We find a degradation to the energy resolution of 7 keV X-rays of $\approx$0.04 eV. By modifying wafer parameters and comparing the simulated TOD, this study is a valuable tool for probing design changes on the thermal background seen by the detectors.
[3]  oai:arXiv.org:1912.06390  [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-18 special issue
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.
[4]  oai:arXiv.org:1808.09431  [pdf] - 1775655
Magnetic shielding of soft protons in future X-ray telescopes: the case of the ATHENA Wide Field Imager
Comments: Accepted for publication on The Astrophysical Journal on 28/08/2018
Submitted: 2018-08-28
Both the interplanetary space and the Earth magnetosphere are populated by low energy ($\leq300$ keV) protons that are potentially able to scatter on the reflecting surface of Wolter-I optics of X-ray focusing telescopes and reach the focal plane. This phenomenon, depending on the X-ray instrumentation, can dramatically increase the background level, reducing the sensitivity or, in the most extreme cases, compromising the observation itself. The use of a magnetic diverter, deflecting protons away from the field of view, requires a detailed characterization of their angular and energy distribution when exiting the mirror. We present the first end-to-end Geant4 simulation of proton scattering by X-ray optics and the consequent interaction with the diverter field and the X-ray detector assembly, selecting the ATHENA Wide Field Imager as a case study for the evaluation of the residual soft proton induced background. We obtain that, in absence of a magnetic diverter, protons are indeed funneled towards the focal plane, with a focused Non X-ray Background well above the level required by ATHENA science objectives ($5\times10^{-4}$ counts cm$^{-2}$ s$^{-1}$ keV$^{-1}$), for all the plasma regimes encountered in both L1 and L2 orbits. These results set the proton diverter as a mandatory shielding system on board the ATHENA mission and all high throughput X-ray telescopes operating in the interplanetary space. For a magnetic field computed to deflect 99\% of the protons that would otherwise reach the WFI, Geant4 simulations show that this configuration, in the assumption of a uniform field, would efficiently shield the focal plane, yielding a residual background level of the order or below the requirement.
[5]  oai:arXiv.org:1807.08561  [pdf] - 1720395
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the role of the athermal phonons collectors in the AC-S8 prototype
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-17 special issue
Submitted: 2018-07-23
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below the TES array. The last CryoAC single-pixel prototypes, namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers sensed by 65 parallel-connected iridium TES. This design has been adopted to improve the response generated by the athermal phonons, which will be used as fast anticoincidence flag. The latter sample is featured also with a network of Aluminum fingers directly connected to the TES, designed to further improve the athermals collection efficiency. In this paper we will report the main results obtained with AC-S8, showing that the additional fingers network is able to increase the energy collected from the athermal part of the pulses (from the 6% of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to prevent the quasiparticle recombination in the aluminum, assuring a fast pulse rising front (L/R limited). In our road map, the AC-S8 prototype is the last step before the development of the CryoAC Demonstration Model (DM), which will be the detector able to demonstrate the critical technologies expected in the CryoAC development programme.
[6]  oai:arXiv.org:1807.08565  [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of the test setup towards the Demonstration Model
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-17 special issue
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the TES array. Before the delivery, we will characterize and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the main results of the activities performed to improve our cryogenic test setup, making it suitable for the DM integration. These activities mainly consist in the development of a mechanichal setup and a cryogenic magnetic shielding system, whose effectiveness has been assessed by FEM simulations and a measurement at warm. The preliminary performance test has been performed by means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[7]  oai:arXiv.org:1807.06092  [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier; Trong, Thien Lam; Herder, Jan-Willem den; Piro, Luigi; Cappi, Massimo; Huovelin, Juhani; Kelley, Richard; Mas-Hesse, J. Miguel; Mitsuda, Kazuhisa; Paltani, Stéphane; Rauw, Gregor; Rozanska, Agata; Wilms, Joern; Bandler, Simon; Barbera, Marco; Barcons, Xavier; Bozzo, Enrico; Ceballos, Maria Teresa; Charles, Ivan; Costantini, Elisa; Decourchelle, Anne; Hartog, Roland den; Duband, Lionel; Duval, Jean-Marc; Fiore, Fabrizio; Gatti, Flavio; Goldwurm, Andrea; Jackson, Brian; Jonker, Peter; Kilbourne, Caroline; Macculi, Claudio; Mendez, Mariano; Molendi, Silvano; Orleanski, Piotr; Pajot, François; Pointecouteau, Etienne; Porter, Frederick; Pratt, Gabriel W.; Prêle, Damien; Ravera, Laurent; Sato, Kosuke; Schaye, Joop; Shinozaki, Keisuke; Thibert, Tanguy; Valenziano, Luca; Valette, Veronique; Vink, Jacco; Webb, Natalie; Wise, Michael; Yamasaki, Noriko; Delcelier-Douchin, Françoise; Mesnager, Jean-Michel; Pontet, Bernard; Pradines, Alice; Branduardi-Raymont, Graziella; Bulbul, Esra; Dadina, Mauro; Ettori, Stefano; Finoguenov, Alexis; Fukazawa, Yasushi; Janiuk, Agnieszka; Kaastra, Jelle; Mazzotta, Pasquale; Miller, Jon; Miniutti, Giovanni; Nazé, Yaël; Nicastro, Fabrizio; Sciortino, Salvatore; Simionescu, Aurora; Torrejon, Jose Miguel; Frezouls, Benoît; Geoffray, Hervé; Peille, Philippe; Aicardi, Corinne; André, Jérôme; Clénet, Antoine; Daniel, Christophe; Etcheverry, Christophe; Gloaguen, Emilie; Hervet, Gilles; Jolly, Antoine; Ledot, Aurélien; Maussang, Irwin; Paillet, Alexis; Schmisser, Roseline; Vella, Bruno; Damery, Jean-Charles; Boyce, Kevin; DiPirro, Michael; Lotti, Simone; Schwander, Denis; Smith, Stephen; van Leeuwen, Bert-Joost; van Weers, Henk; Clerc, Nicolas; Cobo, Beatriz; Dauser, Thomas; de Plaa, Jelle; Kirsch, Christian; Cucchetti, Edoardo; Eckart, Megan; Ferrando, Philippe; Natalucci, Lorenzo
Comments: 15 pages, 5 figures, to appear in Proc. SPIE Astronomical Telescopes and Instrumentation, Austin 2018
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of about 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.
[8]  oai:arXiv.org:1807.02344  [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model
Comments: Proceeding of the SPIE Astronomical Telescopes + Instrumentation 2018
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM. In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).
[9]  oai:arXiv.org:1807.01573  [pdf] - 1710729
Reproducibility and monitoring of the instrumental particle background for the X-Ray Integral Field Unit
Comments: 11 pages, 4 figures, SPIE proceeding Austin 2018
Submitted: 2018-07-04
The X-ray Integral Field Unit (X-IFU) is the cryogenic imaging spectrometer on board the future X-ray observatory \textsl{Athena}. With a hexagonal array of 3840 AC-biased Transition Edge Sensors (TES), it will provide narrow-field observations (5$^{\prime}$ equivalent diameter) with unprecedented high spectral resolution (2.5 eV up to 7 keV) over the 0.2 - 12 keV bandpass. Throughout its observations, the X-IFU will face various sources of X-ray background. Specifically, the so-called Non-X-ray Background (NXB) caused by the interaction of high-energy cosmic rays with the instrument, may lead to a degradation of its sensitivity in the observation of faint extended sources (e.g. galaxy clusters outskirts). To limit this effect, a cryogenic anti-coincidence detector (CryoAC) will be placed below the detector plane to lower the NXB level down to the required level of $5 \times 10^{-3}$ cts/s/cm$^{2}$/keV over 2 - 10 keV. In this contribution, we investigate ways to accurately monitor the NXB and ensure the highest reproducibility in-flight. Using the limiting science case of the background-dominated observation of galaxy clusters outskirts, we demonstrate that a reproducibility of 2\% on the absolute knowledge of the background is required to perform driving science objectives, such as measuring abundances and turbulence in the outskirts. Monitoring of the NXB in-flight through closed observations, the detector's CryoAC or the companion instrument (Wide Field Imager) will be used to meet this requirement.
[10]  oai:arXiv.org:1806.04501  [pdf] - 1698332
The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering
Comments: Proceeding of the SPIE Astronomical Telescopes + Instrumentation Conference, 10 - 15 June 2018
Submitted: 2018-06-12
Given the unprecedented effective area, the new ATHENA Silicon Pore Optics (SPO) focusing technology, the dynamic and variable L2 environment, where no X-ray mission has flown up to date, a dedicated Geant4 simulation campaign is needed to evaluate the impact of low energy protons scattering on the ATHENA mirror surface and the induced residual background level on its X-ray detectors. The Geant4 mass model is built as part of the ESA AREMBES project activities using the BoGEMMS framework. An SPO mirror module row is the atomic unit of the mass model, allowing the simulation of the full structure by means of 20 independent runs, one for each row. Thanks to the BoGEMMS configuration files, both single pores, mirror modules or the entire SPO row can be built with the same Geant4 geometry. Both Remizovich, in its elastic approximation, and Coulomb single scattering Geant4 models are used in the interaction of mono-energetic proton beams with a single SPO pore. The scattering efficiency for the first model is almost twice the efficiency obtained with the latter but for both cases we obtain similar polar and azimuthal angular distributions, with about 70-75% of scatterings generated by single or double reflections. The soft proton flux modelled for the plasma sheet region is used as input for the simulation of soft proton funnelling by the full SPO mass model. A much weaker soft proton vignetting than the one observed by XMM-Newton EPIC detectors is generated by ATHENA mirrors. The residual soft proton flux reaching the focal plane, defined as a 15 cm radius, is 10^4 times lower than the input L2 soft proton population entering the mirror, at the same energy, with rates comparable or higher than the ones observed in XMM EPIC-pn most intense soft proton flares.
[11]  oai:arXiv.org:1707.02221  [pdf] - 1938219
Geant4 simulations of soft proton scattering in X-ray optics. A tentative validation using laboratory measurements
Comments: submitted to Experimental Astronomy
Submitted: 2017-07-07
Low energy protons (< 300 keV) can enter the field of view of X-ray space telescopes, scatter at small incident angles, and deposit energy on the detector, causing intense background flares at the focal plane or in the most extreme cases, damaging the X-ray detector. A correct modelization of the physics process responsible for the grazing angle scattering processes is mandatory to evaluate the impact of such events on the performance of future X-ray telescopes as the ESA ATHENA mission. For the first time the Remizovich model, in the approximation of no energy losses, is implemented top of the Geant4 release 10.2. Both the new scattering physics and the built-in Coulomb scattering are used to reproduce the latest experimental results on grazing angle proton scattering. At 250 keV multiple scattering delivers large proton angles and it is not consistent with the observation. Among the tested models, the single scattering seems to better reproduce the scattering efficiency at the three energies but energy loss obtained at small scattering angles is significantly lower than the experimental values. In general, the energy losses obtained in the experiment are higher than what obtained by the simulation. The experimental data are not completely representative of the soft proton scattering experienced by current X-ray telescopes because of the lack of measurements at low energies (< 200 keV) and small reflection angles, so we are not able to address any of the tested models as the one that can certainly reproduce the scattering behavior of low energy protons expected for the ATHENA mission. We can, however, discard multiple scattering as the model able to reproduce soft proton funneling, and affirm that Coulomb single scattering can represent, until further measurements, the best approximation of the proton scattered angular distribution at the exit of X-ray optics.
[12]  oai:arXiv.org:1705.07004  [pdf] - 1583644
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band
Comments: Accepted for publication on Experimental Astronomy
Submitted: 2017-05-19
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed <1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E>10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.
[13]  oai:arXiv.org:1705.04076  [pdf] - 1583329
The particle background of the X-IFU instrument
Comments:
Submitted: 2017-05-11
In this paper we are going to review the latest estimates for the particle background expected on the X-IFU instrument onboard of the ATHENA mission. The particle background is induced by two different particle populations: the so called "soft protons" and the Cosmic rays. The first component is composed of low energy particles (< 100s keV) that get funnelled by the mirrors towards the focal plane, losing part of their energy inside the filters and inducing background counts inside the instrument sensitivity band. The latter component is induced by high energy particles (> 100 MeV) that possess enough energy to cross the spacecraft and reach the detector from any direction, depositing a small fraction of their energy inside the instrument. Both these components are estimated using Monte Carlo simulations and the latest results are presented here.
[14]  oai:arXiv.org:1704.08498  [pdf] - 1569386
Updates on the background estimates for the X-IFU instrument onboard of the ATHENA mission
Comments:
Submitted: 2017-04-27
ATHENA, with a launch foreseen in 2028 towards the L2 orbit, addresses the science theme "The Hot and Energetic Universe", coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these, the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array providing spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The background for this kind of detectors accounts for several components: the diffuse Cosmic X-ray Background, the low energy particles (<~100 keV) focalized by the mirrors and reaching the detector from inside the field of view, and the high energy particles (>~100 MeV) crossing the spacecraft and reaching the focal plane from every direction. Each one of these components is under study to reduce their impact on the instrumental performances. This task is particularly challenging, given the lack of data on the background of X-ray detectors in L2, the uncertainties on the particle environment to be expected in such orbit, and the reliability of the models used in the Monte Carlo background computations. As a consequence, the activities addressed by the group range from the reanalysis of the data of previous missions like XMM-Newton, to the characterization of the L2 environment by data analysis of the particle monitors onboard of satellites present in the Earth magnetotail, to the characterization of solar events and their occurrence, and to the validation of the physical models involved in the Monte Carlo simulations. All these activities will allow to develop a set of reliable simulations to predict, analyze and find effective solutions to reduce the particle background experienced by the X-IFU, ultimately satisfying the scientific requirement that enables the science of ATHENA. While the activities are still ongoing, we present here some preliminary results already obtained by the group.
[15]  oai:arXiv.org:1608.08105  [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier; Trong, Thien Lam; Herder, Jan-Willem den; Piro, Luigi; Barcons, Xavier; Huovelin, Juhani; Kelley, Richard; Mas-Hesse, J. Miguel; Mitsuda, Kazuhisa; Paltani, Stéphane; Rauw, Gregor; Rożanska, Agata; Wilms, Joern; Barbera, Marco; Bozzo, Enrico; Ceballos, Maria Teresa; Charles, Ivan; Decourchelle, Anne; Hartog, Roland den; Duval, Jean-Marc; Fiore, Fabrizio; Gatti, Flavio; Goldwurm, Andrea; Jackson, Brian; Jonker, Peter; Kilbourne, Caroline; Macculi, Claudio; Mendez, Mariano; Molendi, Silvano; Orleanski, Piotr; Pajot, François; Pointecouteau, Etienne; Porter, Frederick; Pratt, Gabriel W.; Prêle, Damien; Ravera, Laurent; Renotte, Etienne; Schaye, Joop; Shinozaki, Keisuke; Valenziano, Luca; Vink, Jacco; Webb, Natalie; Yamasaki, Noriko; Delcelier-Douchin, Françoise; Du, Michel Le; Mesnager, Jean-Michel; Pradines, Alice; Branduardi-Raymont, Graziella; Dadina, Mauro; Finoguenov, Alexis; Fukazawa, Yasushi; Janiuk, Agnieszka; Miller, Jon; Nazé, Yaël; Nicastro, Fabrizio; Sciortino, Salvatore; Torrejon, Jose Miguel; Geoffray, Hervé; Hernandez, Isabelle; Luno, Laure; Peille, Philippe; André, Jérôme; Daniel, Christophe; Etcheverry, Christophe; Gloaguen, Emilie; Hassin, Jérémie; Hervet, Gilles; Maussang, Irwin; Moueza, Jérôme; Paillet, Alexis; Vella, Bruno; Garrido, Gonzalo Campos; Damery, Jean-Charles; Panem, Chantal; Panh, Johan; Bandler, Simon; Biffi, Jean-Marc; Boyce, Kevin; Clénet, Antoine; DiPirro, Michael; Jamotton, Pierre; Lotti, Simone; Schwander, Denis; Smith, Stephen; van Leeuwen, Bert-Joost; van Weers, Henk; Brand, Thorsten; Cobo, Beatriz; Dauser, Thomas; de Plaa, Jelle; Cucchetti, Edoardo
Comments: 41 pages, 18 Figures
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we briefly describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with further ESA member state contributions from Belgium, Finland, Germany, Poland, Spain, Switzerland and two international partners from the United States and Japan.
[16]  oai:arXiv.org:1410.3373  [pdf] - 968944
In-orbit background of X-ray microcalorimeters and its effects on observations
Comments: the PDF has poor quality, it will be improved in the future
Submitted: 2014-10-13, last modified: 2015-03-20
Methods.There are no experimental data about the background experienced by microcalorimeters in the L2 orbit, and thus the particle background levels were calculated by means of Monte Carlo simulations: we considered the original design configuration and an improved configuration aimed to reduce the unrejected background, and tested them in the L2 orbit and in the low Earth orbit, comparing the results with experimental data reported by other X-ray instruments.To show the results obtainable with the improved configuration we simulated the observation of a faint, high-redshift, point source (F[0.5-10 keV]~6.4E-16 erg cm-2 s-1, z=3.7), and of a hot galaxy cluster at R200 (Sb[0.5-2 keV]=8.61E-16 erg cm-2 s-1 arcmin-2,T=6.6 keV). Results.First we confirm that implementing an active cryogenic anticoincidence reduces the particle background by an order of magnitude and brings it close to the required level.The implementation and test of several design solutions can reduce the particle background level by a further factor of 6 with respect to the original configuration.The best background level achievable in the L2 orbit with the implementation of ad-hoc passive shielding for secondary particles is similar to that measured in the more favorable LEO environment without the passive shielding, allowing us to exploit the advantages of the L2 orbit.We define a reference model for the diffuse background and collect all the available information on its variation with epoch and pointing direction.With this background level the ATHENA mission with the X-IFU instrument is able to detect ~4100 new obscured AGNs with F>6.4E-16 erg cm-2 s-1 during three years, to characterize cluster of galaxies with Sb(0.5-2 keV)>9.4E-16 erg cm-2 s-1 sr-1 on timescales of 50 ks (500 ks) with errors <40% (<12%) on metallicity,<16% (4.8%) on temperature,2.6% (0.72%) on the gas density, and several single-element abundances.
[17]  oai:arXiv.org:1308.6784  [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+
Comments: Supporting paper for the science theme "The Hot and Energetic Universe" to be implemented by the Athena+ X-ray observatory (http://www.the-athena-x-ray-observatory.eu). 17 pages, 19 figures
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.
[18]  oai:arXiv.org:1205.3002  [pdf] - 534553
Estimate of the impact of background particles on the X-Ray Microcalorimeter Spectrometer on IXO
Comments: 18 pages, 9 figures
Submitted: 2012-05-14
We present the results of a study on the impact of particles of galactic (GCR) and solar origin for the X-ray Microcalorimeter Spectrometer (XMS) aboard an astronomical satellite flying in an orbit at the second Lagrangian point (L2). The detailed configuration presented in this paper is the one adopted for the International X-Ray Observatory (IXO) study, however the derived estimates can be considered a conservative limit for ATHENA, that is the IXO redefined mission proposed to ESA. This work is aimed at the estimate of the residual background level expected on the focal plane detector during the mission lifetime, a crucial information in the development of any instrumental configuration that optimizes the XMS scientific performances. We used the Geant4 toolkit, a Monte Carlo based simulator, to investigate the rejection efficiency of the anticoincidence system and assess the residual background on the detector.
[19]  oai:arXiv.org:1104.2048  [pdf] - 576598
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Herder, J. W. den; Piro, L.; Ohashi, T.; Kouveliotou, C.; Hartmann, D. H.; Kaastra, J. S.; Amati, L.; Andersen, M. I.; Arnaud, M.; Attéia, J-L.; Bandler, S.; Barbera, M.; Barcons, X.; Barthelmy, S.; Basa, S.; Basso, S.; Boer, M.; Branchini, E.; Branduardi-Raymont, G.; Borgani, S.; Boyarsky, A.; Brunetti, G.; Budtz-Jorgensen, C.; Burrows, D.; Butler, N.; Campana, S.; Caroli, E.; Ceballos, M.; Christensen, F.; Churazov, E.; Comastri, A.; Colasanti, L.; Cole, R.; Content, R.; Corsi, A.; Costantini, E.; Conconi, P.; Cusumano, G.; de Plaa, J.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; De Pasquale, M.; Doriese, R.; Ettori, S.; Evans, P.; Ezoe, Y.; Ferrari, L.; Finger, H.; Figueroa-Feliciano, T.; Friedrich, P.; Fujimoto, R.; Furuzawa, A.; Fynbo, J.; Gatti, F.; Galeazzi, M.; Gehrels, N.; Gendre, B.; Ghirlanda, G.; Ghisellini, G.; Gilfanov, M.; Giommi, P.; Girardi, M.; Grindlay, J.; Cocchi, M.; Godet, O.; Guedel, M.; Haardt, F.; Hartog, R. den; Hepburn, I.; Hermsen, W.; Hjorth, J.; Hoekstra, H.; Holland, A.; Hornstrup, A.; van der Horst, A.; Hoshino, A.; Zand, J. in 't; Irwin, K.; Ishisaki, Y.; Jonker, P.; Kitayama, T.; Kawahara, H.; Kawai, N.; Kelley, R.; Kilbourne, C.; de Korte, P.; Kusenko, A.; Kuvvetli, I.; Labanti, M.; Macculi, C.; Maiolino, R.; Hesse, M. Mas; Matsushita, K.; Mazzotta, P.; McCammon, D.; Méndez, M.; Mignani, R.; Mineo, T.; Mitsuda, K.; Mushotzky, R.; Molendi, S.; Moscardini, L.; Natalucci, L.; Nicastro, F.; O'Brien, P.; Osborne, J.; Paerels, F.; Page, M.; Paltani, S.; Pedersen, K.; Perinati, E.; Ponman, T.; Pointecouteau, E.; Predehl, P.; Porter, S.; Rasmussen, A.; Rauw, G.; Röttgering, H.; Roncarelli, M.; Rosati, P.; Quadrini, E.; Ruchayskiy, O.; Salvaterra, R.; Sasaki, S.; Sato, K.; Savaglio, S.; Schaye, J.; Sciortino, S.; Shaposhnikov, M.; Sharples, R.; Shinozaki, K.; Spiga, D.; Sunyaev, R.; Suto, Y.; Takei, Y.; Tanvir, N.; Tashiro, M.; Tamura, T.; Tawara, Y.; Troja, E.; Tsujimoto, M.; Tsuru, T.; Ubertini, P.; Ullom, J.; Ursino, E.; Verbunt, F.; van de Voort, F.; Viel, M.; Wachter, S.; Watson, D.; Weisskopf, M.; Werner, N.; White, N.; Willingale, R.; Wijers, R.; Yamasaki, N.; Yoshikawa, K.; Zane, S.
Comments: 34 pages, 13 figures. ESA Cosmic Vision medium-class mission (M3) proposal. Accepted for publication in Experimental Astronomy. Including minor corrections in the author list
Submitted: 2011-04-11, last modified: 2011-04-15
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10, and beyond. The mission will answer questions such as: When were the first metals created? How does the cosmic metal content evolve? Where do most of the metals reside in the Universe? What is the role of metals in structure formation and evolution? To reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to study their local environments in their host galaxies. This requires the capability to slew the satellite in less than a minute to the GRB location. By studying the chemical composition and properties of clusters of galaxies we can extend the range of exploration to lower redshifts (z ~ 0.2). For this task we need a high-resolution spectral imaging instrument with a large field of view. Using the same instrument, we can also study the so far only partially detected baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the WHIM will be studied using absorption lines at low redshift in the spectra for GRBs.
[20]  oai:arXiv.org:astro-ph/0602588  [pdf] - 80164
Systematic effects induced by a flat isotropic dielectric slab
Comments: Accepted for pubblication in Applied Optics, 32 pages, 14 figures (N. 37 ".png", ".bb"). Better quality figures available from author upon request
Submitted: 2006-02-27
The instrumental polarization induced by a flat isotropic dielectric slab in microwave frequencies is faced. We find that, in spite of its isotropic nature, such a dielectric can produce spurious polarization either by transmitting incoming anisotropic diffuse radiation or emitting when it is thermally inhomogeneous. We present evaluations of instrumental polarization generated by materials usually adopted in Radioastronomy, by using the Mueller matrix formalism. As an application, results for different slabs in front of a 32 GHz receiver are discussed. Such results are based on measurements of their complex dielectric constant. We evaluate that a 0.33 cm thick Teflon slab introduces negligible spurious polarization ($< 2.6 \times 10^{-5}$ in transmission and $< 6 \times 10^{-7}$ in emission), even minimizing the leakage ($< 10^{-8}$ from $Q$ to $U$ Stokes parameters, and viceversa) and the depolarization ($\sim 1.3 \times 10^{-3}$).
[21]  oai:arXiv.org:astro-ph/0408498  [pdf] - 66989
Effects of Thermal Fluctuations in the SPOrt Experiment
Comments: 12 pages, 11 figures. Accepted for publication in A&A
Submitted: 2004-08-26
The role of systematic errors induced by thermal fluctuations is analyzed for the SPOrt experiment with the aim at estimating their impact on the measurement of the Cosmic Microwave Background Polarization (CMBP). The transfer functions of the antenna devices from temperature to data fluctuations are computed, by writing them in terms of both instrument and thermal environment parameters. In addition, the corresponding contamination maps are estimated, along with their polarized power spectra, for different behaviours of the instabilities. The result is that thermal effects are at a negligible level even for fluctuations correlated with the Sun illumination provided their frequency $f_{tf}$ is larger than that of the Sun illumination ($f_{day}$) by a factor $f_{tf} / f_{day} > 30$, which defines a requirement for the statistical properties of the temperature behaviour as well. The analysis with actual SPOrt operative parameters shows that the instrument is only weakly sensitive to temperature instabilities, the main contribution coming from the cryogenic stage. The contamination on the E-mode spectrum does not significantly pollute the CMBP signal and no specific data cleaning seems to be needed.
[22]  oai:arXiv.org:astro-ph/0401193  [pdf] - 62063
The Sky Polarization Observatory
Comments: 53 pages, 22 figures, 1 reference replaced
Submitted: 2004-01-12, last modified: 2004-01-14
SPOrt is an ASI-funded experiment specifically designed to measure the sky polarization at 22, 32 and 90 GHz, which was selected in 1997 by ESA to be flown on the International Space Station. Starting in 2006 and for at least 18 months, it will be taking direct and simultaneous measurements of the Stokes parameters Q and U at 660 sky pixels, with FWHM=7 degrees. Due to development efforts over the past few years, the design specifications have been significantly improved with respect to the first proposal. Here we present an up-to-date description of the instrument, which now warrants a pixel sensitivity of 1.7 microK for the polarization of the cosmic background radiation, assuming two years of observations. We discuss SPOrt scientific goals in the light of WMAP results, in particular in connection with the emerging double-reionization cosmological scenario.
[23]  oai:arXiv.org:astro-ph/0302276  [pdf] - 54903
An iterative destriping technique for diffuse background polarization data
Comments: Accepted for publication by A&A (8 pages, 6 figures)
Submitted: 2003-02-14
We describe a simple but effective iterative procedure specifically designed to destripe Q and U Stokes parameter data as those collected by the SPOrt experiment onboard the International Space Station (ISS). The method is general enough to be useful for other experiments, both in polarization and total intensity. The only requirement for the algorithm to work properly is that the receiver knee frequency must be lower than the signal modulation frequency, corresponding in our case to the ISS orbit period. Detailed performances of the technique are presented in the context of the SPOrt experiment, both in terms of added rms noise and residual correlated noise.
[24]  oai:arXiv.org:astro-ph/0301020  [pdf] - 53991
The BaR-SPOrt Experiment
Comments: 12 pages, 10 figures, Astronomical Telescopes and Instrumentation (Polaimetry in Astronomy) Hawaii August 2002 SPIE Meeting
Submitted: 2003-01-02
BaR-SPOrt (Balloon-borne Radiometers for Sky Polarisation Observations) is an experiment to measure the linearly polarized emission of sky patches at 32 and 90 GHz with sub-degree angular resolution. It is equipped with high sensitivity correlation polarimeters for simultaneous detection of both the U and Q stokes parameters of the incident radiation. On-axis telescope is used to observe angular scales where the expected polarization of the Cosmic Microwave Background (CMBP) peaks. This project shares most of the know-how and sophisticated technology developed for the SPOrt experiment onboard the International Space Station. The payload is designed to flight onboard long duration stratospheric balloons both in the Northern and Southern hemispheres where low foreground emission sky patches are accessible. Due to the weakness of the expected CMBP signal (in the range of microK), much care has been spent to optimize the instrument design with respect to the systematics generation, observing time efficiency and long term stability. In this contribution we present the instrument design, and first tests on some components of the 32 GHz radiometer.
[25]  oai:arXiv.org:astro-ph/0212067  [pdf] - 53457
SPOrt: an Experiment Aimed at Measuring the Large Scale Cosmic Microwave Background Polarization
Comments: 9 pages, 5 figures, conference proceeding, to appear in "Polarimetry in Astronomy", SPIE Symposium on 'Astronomical Telescopes and Instrumentation', Waikoloa, August 22-28 2002
Submitted: 2002-12-03
SPOrt (Sky Polarization Observatory) is a space experiment to be flown on the International Space Station during Early Utilization Phase aimed at measuring the microwave polarized emission with FWHM = 7deg, in the frequency range 22-90 GHz. The Galactic polarized emission can be observed at the lower frequencies and the polarization of Cosmic Microwave Background (CMB) at 90 GHz, where contaminants are expected to be less important. The extremely low level of the CMB Polarization signal (< 1 uK) calls for intrinsically stable radiometers. The SPOrt instrument is expressly devoted to CMB polarization measurements and the whole design has been optimized for minimizing instrumental polarization effects. In this contribution we present the receiver architecture based on correlation techniques, the analysis showing its intrinsic stability and the custom hardware development carried out to detect such a low signal.