Normalized to: Macculi, C.
[1]
oai:arXiv.org:2003.07295 [pdf] - 2077065
Soft proton scattering at grazing incidence from X-ray mirrors: analysis
of experimental data in the framework of the non-elastic approximation
Amato, R.;
Mineo, T.;
D'Aì, A.;
Diebold, S.;
Fioretti, V.;
Guzman, A.;
Lotti, S.;
Macculi, C.;
Molendi, S.;
Perinati, E.;
Tenzer, C.;
Santangelo, A.
Submitted: 2020-03-16
Astronomical X-ray observatories with grazing incidence optics face the
problem of pseudo-focusing of low energy protons from the mirrors towards the
focal plane. Those protons constitute a variable, unpredictable component of
the non X-ray background that strongly affects astronomical observations and a
correct estimation of their flux at the focal plane is then essential. For this
reason, we investigate how they are scattered from the mirror surfaces when
impacting with grazing angles. We compare the non-elastic model of reflectivity
of particles at grazing incidence proposed by Remizovich et al. (1980) with the
few available experimental measurements of proton scattering from X-ray
mirrors. We develop a semi-empirical analytical model based on the fit of those
experimental data with the Remizovich solution. We conclude that the scattering
probability weakly depends on the energy of the impinging protons and that the
relative energy losses are necessary to correctly model the data. The model we
propose assumes no dependence on the incident energy and can be implemented in
particle transport simulation codes to generate, for instance, proton response
matrices for specific X-ray missions. Further laboratory measurements at lower
energies and on other mirror samples, such as ATHENA Silicon Pore Optics, will
improve the resolution of the model and will allow us to build the proper
proton response matrices for a wider sample of X-ray observatories.
[2]
oai:arXiv.org:2001.11646 [pdf] - 2065397
Thermal simulations of temperature excursions on the Athena X-IFU
detector wafer from impacts by cosmic rays
Submitted: 2020-01-30
We present the design and implementation of a thermal model, developed in
COMSOL, aiming to probe the wafer-scale thermal response arising from realistic
rates and energies of cosmic rays at L2 impacting the detector wafer of Athena
X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers
represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and
2 layers represent the Au metallization layer's phonon and electron
temperatures. We base the simulation geometry on the current specifications for
the X-IFU detector wafer, and simulate cosmic ray impacts using a simple power
injection into the Si bulk. We measure the temperature at the point of the
instrument's most central TES detector. By probing the response of the system
and pulse characteristics as a function of the thermal input energy and
location, we reconstruct cosmic ray pulses in Python. By utilizing this code,
along with the results of the GEANT4 simulations produced for X-IFU, we produce
realistic time-ordered data (TOD) of the temperature seen by the central TES,
which we use to simulate the degradation of the energy resolution of the
instrument in space-like conditions on this wafer. We find a degradation to the
energy resolution of 7 keV X-rays of $\approx$0.04 eV. By modifying wafer
parameters and comparing the simulated TOD, this study is a valuable tool for
probing design changes on the thermal background seen by the detectors.
[3]
oai:arXiv.org:1912.06390 [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence
Detector
D'Andrea, Matteo;
Macculi, Claudio;
Torrioli, Guido;
Argan, Andrea;
Brienza, Daniele;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Barusso, Lorenzo Ferrari;
Gatti, Flavio;
Rigano, Manuela;
Volpe, Angela;
Battistelli, Elia Stefano
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed
to reduce the particle background of the instrument and to enable the mission
science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES
network. We have developed the CryoAC Demonstration Model, a prototype aimed to
probe the critical technologies of the detector, i.e. the suspended absorber
with an active area of 1 cm2; the low energy threshold of 20 keV; and the
operation connected to a 50 mK thermal bath with a power dissipation less than
40 nW. Here we report the test performed on the first CryoAC DM sample (namely
the AC-S10 prototype), showing that it is fully compliant with its
requirements.
[4]
oai:arXiv.org:1808.09431 [pdf] - 1775655
Magnetic shielding of soft protons in future X-ray telescopes: the case
of the ATHENA Wide Field Imager
Fioretti, Valentina;
Bulgarelli, Andrea;
Molendi, Silvano;
Lotti, Simone;
Macculi, Claudio;
Barbera, Marco;
Mineo, Teresa;
Piro, Luigi;
Cappi, Massimo;
Dadina, Mauro;
Meidinger, Norbert;
von Kienlin, Andreas;
Rau, Arne
Submitted: 2018-08-28
Both the interplanetary space and the Earth magnetosphere are populated by
low energy ($\leq300$ keV) protons that are potentially able to scatter on the
reflecting surface of Wolter-I optics of X-ray focusing telescopes and reach
the focal plane. This phenomenon, depending on the X-ray instrumentation, can
dramatically increase the background level, reducing the sensitivity or, in the
most extreme cases, compromising the observation itself. The use of a magnetic
diverter, deflecting protons away from the field of view, requires a detailed
characterization of their angular and energy distribution when exiting the
mirror. We present the first end-to-end Geant4 simulation of proton scattering
by X-ray optics and the consequent interaction with the diverter field and the
X-ray detector assembly, selecting the ATHENA Wide Field Imager as a case study
for the evaluation of the residual soft proton induced background. We obtain
that, in absence of a magnetic diverter, protons are indeed funneled towards
the focal plane, with a focused Non X-ray Background well above the level
required by ATHENA science objectives ($5\times10^{-4}$ counts cm$^{-2}$
s$^{-1}$ keV$^{-1}$), for all the plasma regimes encountered in both L1 and L2
orbits. These results set the proton diverter as a mandatory shielding system
on board the ATHENA mission and all high throughput X-ray telescopes operating
in the interplanetary space. For a magnetic field computed to deflect 99\% of
the protons that would otherwise reach the WFI, Geant4 simulations show that
this configuration, in the assumption of a uniform field, would efficiently
shield the focal plane, yielding a residual background level of the order or
below the requirement.
[5]
oai:arXiv.org:1807.08561 [pdf] - 1720395
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the
role of the athermal phonons collectors in the AC-S8 prototype
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido
Submitted: 2018-07-23
The ATHENA X-ray Observatory is the second large-class mission in the ESA
Cosmic Vision 2015-2025 science programme. One of the two on-board instruments
is the X-IFU, an imaging spectrometer based on a large array of TES
microcalorimeters. To reduce the particle-induced background, the spectrometer
works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed
less than 1 mm below the TES array. The last CryoAC single-pixel prototypes,
namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers
sensed by 65 parallel-connected iridium TES. This design has been adopted to
improve the response generated by the athermal phonons, which will be used as
fast anticoincidence flag. The latter sample is featured also with a network of
Aluminum fingers directly connected to the TES, designed to further improve the
athermals collection efficiency. In this paper we will report the main results
obtained with AC-S8, showing that the additional fingers network is able to
increase the energy collected from the athermal part of the pulses (from the 6%
of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to
prevent the quasiparticle recombination in the aluminum, assuring a fast pulse
rising front (L/R limited). In our road map, the AC-S8 prototype is the last
step before the development of the CryoAC Demonstration Model (DM), which will
be the detector able to demonstrate the critical technologies expected in the
CryoAC development programme.
[6]
oai:arXiv.org:1807.08565 [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of
the test setup towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an
instrument Demonstration Model (DM), in order to probe the system critical
technologies before the mission adoption. In this respect, we are now
developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC),
which will be delivered to the Focal Plane Assembly (FPA) development team for
the integration with the TES array. Before the delivery, we will characterize
and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the
main results of the activities performed to improve our cryogenic test setup,
making it suitable for the DM integration. These activities mainly consist in
the development of a mechanichal setup and a cryogenic magnetic shielding
system, whose effectiveness has been assessed by FEM simulations and a
measurement at warm. The preliminary performance test has been performed by
means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[7]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[8]
oai:arXiv.org:1807.02344 [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary
test of AC-S9 towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Ceriale, Valentina;
Gallucci, Giovanni;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the
ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector,
which will be placed less than 1 mm below the main TES array detector. We are
now producing the CryoAC Demonstration Model (DM): a single pixel prototype
able to probe the detector critical technologies, i.e. the operation at 50 mK
thermal bath, the threshold energy at 20 keV and the reproducibility of the
thermal conductance between the suspended absorber and the thermal bath. This
detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and
then delivered to SRON for the integration in the X-IFU Focal Plane Assemby
(FPA) DM.
In this paper we report the status of the CryoAC DM development, showing the
main result obtained with the last developed prototype, namely AC-S9. This is a
DM-like sample, which we have preliminary integrated and tested before
performing the final etching process to suspend the silicon absorber. The
results are promising for the DM, since despite the limitations due to the
absence of the final etching (high thermal capacity, high thermal conductance,
partial TES surface coverage), we have been able to operate the detector with
TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold
fully compatible with our requirement (20 keV).
[9]
oai:arXiv.org:1807.01573 [pdf] - 1710729
Reproducibility and monitoring of the instrumental particle background
for the X-Ray Integral Field Unit
Cucchetti, Edoardo;
Pointecouteau, Etienne;
Barret, Didier;
Lotti, Simone;
Macculi, Claudio;
Molendi, Silvano;
Pajot, François;
Peille, Philippe;
Piro, Luigi;
Pratt, Gabriel W.
Submitted: 2018-07-04
The X-ray Integral Field Unit (X-IFU) is the cryogenic imaging spectrometer
on board the future X-ray observatory \textsl{Athena}. With a hexagonal array
of 3840 AC-biased Transition Edge Sensors (TES), it will provide narrow-field
observations (5$^{\prime}$ equivalent diameter) with unprecedented high
spectral resolution (2.5 eV up to 7 keV) over the 0.2 - 12 keV bandpass.
Throughout its observations, the X-IFU will face various sources of X-ray
background. Specifically, the so-called Non-X-ray Background (NXB) caused by
the interaction of high-energy cosmic rays with the instrument, may lead to a
degradation of its sensitivity in the observation of faint extended sources
(e.g. galaxy clusters outskirts). To limit this effect, a cryogenic
anti-coincidence detector (CryoAC) will be placed below the detector plane to
lower the NXB level down to the required level of $5 \times 10^{-3}$
cts/s/cm$^{2}$/keV over 2 - 10 keV. In this contribution, we investigate ways
to accurately monitor the NXB and ensure the highest reproducibility in-flight.
Using the limiting science case of the background-dominated observation of
galaxy clusters outskirts, we demonstrate that a reproducibility of 2\% on the
absolute knowledge of the background is required to perform driving science
objectives, such as measuring abundances and turbulence in the outskirts.
Monitoring of the NXB in-flight through closed observations, the detector's
CryoAC or the companion instrument (Wide Field Imager) will be used to meet
this requirement.
[10]
oai:arXiv.org:1806.04501 [pdf] - 1698332
The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect
on soft proton scattering
Submitted: 2018-06-12
Given the unprecedented effective area, the new ATHENA Silicon Pore Optics
(SPO) focusing technology, the dynamic and variable L2 environment, where no
X-ray mission has flown up to date, a dedicated Geant4 simulation campaign is
needed to evaluate the impact of low energy protons scattering on the ATHENA
mirror surface and the induced residual background level on its X-ray
detectors. The Geant4 mass model is built as part of the ESA AREMBES project
activities using the BoGEMMS framework. An SPO mirror module row is the atomic
unit of the mass model, allowing the simulation of the full structure by means
of 20 independent runs, one for each row. Thanks to the BoGEMMS configuration
files, both single pores, mirror modules or the entire SPO row can be built
with the same Geant4 geometry. Both Remizovich, in its elastic approximation,
and Coulomb single scattering Geant4 models are used in the interaction of
mono-energetic proton beams with a single SPO pore. The scattering efficiency
for the first model is almost twice the efficiency obtained with the latter but
for both cases we obtain similar polar and azimuthal angular distributions,
with about 70-75% of scatterings generated by single or double reflections. The
soft proton flux modelled for the plasma sheet region is used as input for the
simulation of soft proton funnelling by the full SPO mass model. A much weaker
soft proton vignetting than the one observed by XMM-Newton EPIC detectors is
generated by ATHENA mirrors. The residual soft proton flux reaching the focal
plane, defined as a 15 cm radius, is 10^4 times lower than the input L2 soft
proton population entering the mirror, at the same energy, with rates
comparable or higher than the ones observed in XMM EPIC-pn most intense soft
proton flares.
[11]
oai:arXiv.org:1707.02221 [pdf] - 1938219
Geant4 simulations of soft proton scattering in X-ray optics. A
tentative validation using laboratory measurements
Submitted: 2017-07-07
Low energy protons (< 300 keV) can enter the field of view of X-ray space
telescopes, scatter at small incident angles, and deposit energy on the
detector, causing intense background flares at the focal plane or in the most
extreme cases, damaging the X-ray detector. A correct modelization of the
physics process responsible for the grazing angle scattering processes is
mandatory to evaluate the impact of such events on the performance of future
X-ray telescopes as the ESA ATHENA mission. For the first time the Remizovich
model, in the approximation of no energy losses, is implemented top of the
Geant4 release 10.2. Both the new scattering physics and the built-in Coulomb
scattering are used to reproduce the latest experimental results on grazing
angle proton scattering. At 250 keV multiple scattering delivers large proton
angles and it is not consistent with the observation. Among the tested models,
the single scattering seems to better reproduce the scattering efficiency at
the three energies but energy loss obtained at small scattering angles is
significantly lower than the experimental values. In general, the energy losses
obtained in the experiment are higher than what obtained by the simulation. The
experimental data are not completely representative of the soft proton
scattering experienced by current X-ray telescopes because of the lack of
measurements at low energies (< 200 keV) and small reflection angles, so we are
not able to address any of the tested models as the one that can certainly
reproduce the scattering behavior of low energy protons expected for the ATHENA
mission. We can, however, discard multiple scattering as the model able to
reproduce soft proton funneling, and affirm that Coulomb single scattering can
represent, until further measurements, the best approximation of the proton
scattered angular distribution at the exit of X-ray optics.
[12]
oai:arXiv.org:1705.07004 [pdf] - 1583644
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific
assessment of the observational capabilities in the hard X-ray band
Submitted: 2017-05-19
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028
towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a
cryogenic spectrometer based on a large array of TES microcalorimeters, able to
perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6
keV). The X-IFU sensitivity is highly degraded by the particle background
expected in the L2 orbit, which is induced by primary protons of both galactic
and solar origin, and mostly by secondary electrons. To reduce the particle
background level and enable the mission science goals, the instrument
incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES
based detector, placed <1 mm below the main array. In this paper we report a
scientific assessment of the CryoAC observational capabilities in the hard
X-ray band (E>10 keV). The aim of the study has been to understand if the
present detector design can be improved in order to enlarge the X-IFU
scientific capability on an energy band wider than the TES array. This is
beyond the CryoAC baseline, being this instrument aimed to operate as
anticoincidence particle detector and not conceived to perform X-ray
observations.
[13]
oai:arXiv.org:1705.04076 [pdf] - 1583329
The particle background of the X-IFU instrument
Submitted: 2017-05-11
In this paper we are going to review the latest estimates for the particle
background expected on the X-IFU instrument onboard of the ATHENA mission. The
particle background is induced by two different particle populations: the so
called "soft protons" and the Cosmic rays. The first component is composed of
low energy particles (< 100s keV) that get funnelled by the mirrors towards the
focal plane, losing part of their energy inside the filters and inducing
background counts inside the instrument sensitivity band. The latter component
is induced by high energy particles (> 100 MeV) that possess enough energy to
cross the spacecraft and reach the detector from any direction, depositing a
small fraction of their energy inside the instrument. Both these components are
estimated using Monte Carlo simulations and the latest results are presented
here.
[14]
oai:arXiv.org:1704.08498 [pdf] - 1569386
Updates on the background estimates for the X-IFU instrument onboard of
the ATHENA mission
Lotti, Simone;
Macculi, Claudio;
D'Andrea, Matteo;
Piro, Luigi;
Molendi, Silvano;
Gastaldello, Fabio;
Mineo, Teresa;
D'Ai, Antonino;
Bulgarelli, Andrea;
Fioretti, Valentina;
Jacquey, Christian;
Laurenza, Monica;
Laurent, Philippe
Submitted: 2017-04-27
ATHENA, with a launch foreseen in 2028 towards the L2 orbit, addresses the
science theme "The Hot and Energetic Universe", coupling a high-performance
X-ray Telescope with two complementary focal-plane instruments. One of these,
the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array providing
spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5
arcmin FoV. The background for this kind of detectors accounts for several
components: the diffuse Cosmic X-ray Background, the low energy particles
(<~100 keV) focalized by the mirrors and reaching the detector from inside the
field of view, and the high energy particles (>~100 MeV) crossing the
spacecraft and reaching the focal plane from every direction. Each one of these
components is under study to reduce their impact on the instrumental
performances. This task is particularly challenging, given the lack of data on
the background of X-ray detectors in L2, the uncertainties on the particle
environment to be expected in such orbit, and the reliability of the models
used in the Monte Carlo background computations. As a consequence, the
activities addressed by the group range from the reanalysis of the data of
previous missions like XMM-Newton, to the characterization of the L2
environment by data analysis of the particle monitors onboard of satellites
present in the Earth magnetotail, to the characterization of solar events and
their occurrence, and to the validation of the physical models involved in the
Monte Carlo simulations. All these activities will allow to develop a set of
reliable simulations to predict, analyze and find effective solutions to reduce
the particle background experienced by the X-IFU, ultimately satisfying the
scientific requirement that enables the science of ATHENA. While the activities
are still ongoing, we present here some preliminary results already obtained by
the group.
[15]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.
[16]
oai:arXiv.org:1410.3373 [pdf] - 968944
In-orbit background of X-ray microcalorimeters and its effects on
observations
Submitted: 2014-10-13, last modified: 2015-03-20
Methods.There are no experimental data about the background experienced by
microcalorimeters in the L2 orbit, and thus the particle background levels were
calculated by means of Monte Carlo simulations: we considered the original
design configuration and an improved configuration aimed to reduce the
unrejected background, and tested them in the L2 orbit and in the low Earth
orbit, comparing the results with experimental data reported by other X-ray
instruments.To show the results obtainable with the improved configuration we
simulated the observation of a faint, high-redshift, point source (F[0.5-10
keV]~6.4E-16 erg cm-2 s-1, z=3.7), and of a hot galaxy cluster at R200
(Sb[0.5-2 keV]=8.61E-16 erg cm-2 s-1 arcmin-2,T=6.6 keV). Results.First we
confirm that implementing an active cryogenic anticoincidence reduces the
particle background by an order of magnitude and brings it close to the
required level.The implementation and test of several design solutions can
reduce the particle background level by a further factor of 6 with respect to
the original configuration.The best background level achievable in the L2 orbit
with the implementation of ad-hoc passive shielding for secondary particles is
similar to that measured in the more favorable LEO environment without the
passive shielding, allowing us to exploit the advantages of the L2 orbit.We
define a reference model for the diffuse background and collect all the
available information on its variation with epoch and pointing direction.With
this background level the ATHENA mission with the X-IFU instrument is able to
detect ~4100 new obscured AGNs with F>6.4E-16 erg cm-2 s-1 during three years,
to characterize cluster of galaxies with Sb(0.5-2 keV)>9.4E-16 erg cm-2 s-1
sr-1 on timescales of 50 ks (500 ks) with errors <40% (<12%) on
metallicity,<16% (4.8%) on temperature,2.6% (0.72%) on the gas density, and
several single-element abundances.
[17]
oai:arXiv.org:1308.6784 [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU)
for Athena+
Barret, D.;
Herder, J. W. den;
Piro, L.;
Ravera, L.;
Hartog, R. Den;
Macculi, C.;
Barcons, X.;
Page, M.;
Paltani, S.;
Rauw, G.;
Wilms, J.;
Ceballos, M.;
Duband, L.;
Gottardi, L.;
Lotti, S.;
de Plaa, J.;
Pointecouteau, E.;
Schmid, C.;
Akamatsu, H.;
Bagliani, D.;
Bandler, S.;
Barbera, M.;
Bastia, P.;
Biasotti, M.;
Branco, M.;
Camon, A.;
Cara, C.;
Cobo, B.;
Colasanti, L.;
Costa-Kramer, J. L.;
Corcione, L.;
Doriese, W.;
Duval, J. M.;
Fabrega, L.;
Gatti, F.;
de Gerone, M.;
Guttridge, P.;
Kelley, R.;
Kilbourne, C.;
van der Kuur, J.;
Mineo, T.;
Mitsuda, K.;
Natalucci, L.;
Ohashi, T.;
Peille, P.;
Perinati, E.;
Pigot, C.;
Pizzigoni, G.;
Pobes, C.;
Porter, F.;
Renotte, E.;
Sauvageot, J. L.;
Sciortino, S.;
Torrioli, G.;
Valenziano, L.;
Willingale, D.;
de Vries, C.;
van Weers, H.
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic
Universe science theme submitted to the European Space Agency in response to
the call for White Papers for the definition of the L2 and L3 missions of its
science program. The Athena+ science payload consists of a large aperture high
angular resolution X-ray optics and twelve meters away, two interchangeable
focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide
Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a
large array of Transition Edge Sensors (TES), offering 2.5 eV spectral
resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter.
In this paper, we briefly describe the Athena+ mission concept and the X-IFU
performance requirements. We then present the X-IFU detector and readout
electronics principles, the current design of the focal plane assembly, the
cooling chain and review the global architecture design. Finally, we describe
the current performance estimates, in terms of effective area, particle
background rejection, count rate capability and velocity measurements. Finally,
we emphasize on the latest technology developments concerning TES array
fabrication, spectral resolution and readout performance achieved to show that
significant progresses are being accomplished towards the demanding X-IFU
requirements.
[18]
oai:arXiv.org:1205.3002 [pdf] - 534553
Estimate of the impact of background particles on the X-Ray
Microcalorimeter Spectrometer on IXO
Submitted: 2012-05-14
We present the results of a study on the impact of particles of galactic
(GCR) and solar origin for the X-ray Microcalorimeter Spectrometer (XMS) aboard
an astronomical satellite flying in an orbit at the second Lagrangian point
(L2). The detailed configuration presented in this paper is the one adopted for
the International X-Ray Observatory (IXO) study, however the derived estimates
can be considered a conservative limit for ATHENA, that is the IXO redefined
mission proposed to ESA. This work is aimed at the estimate of the residual
background level expected on the focal plane detector during the mission
lifetime, a crucial information in the development of any instrumental
configuration that optimizes the XMS scientific performances. We used the
Geant4 toolkit, a Monte Carlo based simulator, to investigate the rejection
efficiency of the anticoincidence system and assess the residual background on
the detector.
[19]
oai:arXiv.org:1104.2048 [pdf] - 576598
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Herder, J. W. den;
Piro, L.;
Ohashi, T.;
Kouveliotou, C.;
Hartmann, D. H.;
Kaastra, J. S.;
Amati, L.;
Andersen, M. I.;
Arnaud, M.;
Attéia, J-L.;
Bandler, S.;
Barbera, M.;
Barcons, X.;
Barthelmy, S.;
Basa, S.;
Basso, S.;
Boer, M.;
Branchini, E.;
Branduardi-Raymont, G.;
Borgani, S.;
Boyarsky, A.;
Brunetti, G.;
Budtz-Jorgensen, C.;
Burrows, D.;
Butler, N.;
Campana, S.;
Caroli, E.;
Ceballos, M.;
Christensen, F.;
Churazov, E.;
Comastri, A.;
Colasanti, L.;
Cole, R.;
Content, R.;
Corsi, A.;
Costantini, E.;
Conconi, P.;
Cusumano, G.;
de Plaa, J.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
De Pasquale, M.;
Doriese, R.;
Ettori, S.;
Evans, P.;
Ezoe, Y.;
Ferrari, L.;
Finger, H.;
Figueroa-Feliciano, T.;
Friedrich, P.;
Fujimoto, R.;
Furuzawa, A.;
Fynbo, J.;
Gatti, F.;
Galeazzi, M.;
Gehrels, N.;
Gendre, B.;
Ghirlanda, G.;
Ghisellini, G.;
Gilfanov, M.;
Giommi, P.;
Girardi, M.;
Grindlay, J.;
Cocchi, M.;
Godet, O.;
Guedel, M.;
Haardt, F.;
Hartog, R. den;
Hepburn, I.;
Hermsen, W.;
Hjorth, J.;
Hoekstra, H.;
Holland, A.;
Hornstrup, A.;
van der Horst, A.;
Hoshino, A.;
Zand, J. in 't;
Irwin, K.;
Ishisaki, Y.;
Jonker, P.;
Kitayama, T.;
Kawahara, H.;
Kawai, N.;
Kelley, R.;
Kilbourne, C.;
de Korte, P.;
Kusenko, A.;
Kuvvetli, I.;
Labanti, M.;
Macculi, C.;
Maiolino, R.;
Hesse, M. Mas;
Matsushita, K.;
Mazzotta, P.;
McCammon, D.;
Méndez, M.;
Mignani, R.;
Mineo, T.;
Mitsuda, K.;
Mushotzky, R.;
Molendi, S.;
Moscardini, L.;
Natalucci, L.;
Nicastro, F.;
O'Brien, P.;
Osborne, J.;
Paerels, F.;
Page, M.;
Paltani, S.;
Pedersen, K.;
Perinati, E.;
Ponman, T.;
Pointecouteau, E.;
Predehl, P.;
Porter, S.;
Rasmussen, A.;
Rauw, G.;
Röttgering, H.;
Roncarelli, M.;
Rosati, P.;
Quadrini, E.;
Ruchayskiy, O.;
Salvaterra, R.;
Sasaki, S.;
Sato, K.;
Savaglio, S.;
Schaye, J.;
Sciortino, S.;
Shaposhnikov, M.;
Sharples, R.;
Shinozaki, K.;
Spiga, D.;
Sunyaev, R.;
Suto, Y.;
Takei, Y.;
Tanvir, N.;
Tashiro, M.;
Tamura, T.;
Tawara, Y.;
Troja, E.;
Tsujimoto, M.;
Tsuru, T.;
Ubertini, P.;
Ullom, J.;
Ursino, E.;
Verbunt, F.;
van de Voort, F.;
Viel, M.;
Wachter, S.;
Watson, D.;
Weisskopf, M.;
Werner, N.;
White, N.;
Willingale, R.;
Wijers, R.;
Yamasaki, N.;
Yoshikawa, K.;
Zane, S.
Submitted: 2011-04-11, last modified: 2011-04-15
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of
metal creation from the epoch of cosmic dawn. Using high-spectral resolution in
the soft X-ray band, ORIGIN will be able to identify the physical conditions of
all abundant elements between C and Ni to red-shifts of z=10, and beyond. The
mission will answer questions such as: When were the first metals created? How
does the cosmic metal content evolve? Where do most of the metals reside in the
Universe? What is the role of metals in structure formation and evolution? To
reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to
study their local environments in their host galaxies. This requires the
capability to slew the satellite in less than a minute to the GRB location. By
studying the chemical composition and properties of clusters of galaxies we can
extend the range of exploration to lower redshifts (z ~ 0.2). For this task we
need a high-resolution spectral imaging instrument with a large field of view.
Using the same instrument, we can also study the so far only partially detected
baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the
WHIM will be studied using absorption lines at low redshift in the spectra for
GRBs.
[20]
oai:arXiv.org:astro-ph/0602588 [pdf] - 80164
Systematic effects induced by a flat isotropic dielectric slab
Submitted: 2006-02-27
The instrumental polarization induced by a flat isotropic dielectric slab in
microwave frequencies is faced. We find that, in spite of its isotropic nature,
such a dielectric can produce spurious polarization either by transmitting
incoming anisotropic diffuse radiation or emitting when it is thermally
inhomogeneous. We present evaluations of instrumental polarization generated by
materials usually adopted in Radioastronomy, by using the Mueller matrix
formalism. As an application, results for different slabs in front of a 32 GHz
receiver are discussed. Such results are based on measurements of their complex
dielectric constant. We evaluate that a 0.33 cm thick Teflon slab introduces
negligible spurious polarization ($< 2.6 \times 10^{-5}$ in transmission and $<
6 \times 10^{-7}$ in emission), even minimizing the leakage ($< 10^{-8}$ from
$Q$ to $U$ Stokes parameters, and viceversa) and the depolarization ($\sim 1.3
\times 10^{-3}$).
[21]
oai:arXiv.org:astro-ph/0408498 [pdf] - 66989
Effects of Thermal Fluctuations in the SPOrt Experiment
Submitted: 2004-08-26
The role of systematic errors induced by thermal fluctuations is analyzed for
the SPOrt experiment with the aim at estimating their impact on the measurement
of the Cosmic Microwave Background Polarization (CMBP). The transfer functions
of the antenna devices from temperature to data fluctuations are computed, by
writing them in terms of both instrument and thermal environment parameters. In
addition, the corresponding contamination maps are estimated, along with their
polarized power spectra, for different behaviours of the instabilities. The
result is that thermal effects are at a negligible level even for fluctuations
correlated with the Sun illumination provided their frequency $f_{tf}$ is
larger than that of the Sun illumination ($f_{day}$) by a factor $f_{tf} /
f_{day} > 30$, which defines a requirement for the statistical properties of
the temperature behaviour as well. The analysis with actual SPOrt operative
parameters shows that the instrument is only weakly sensitive to temperature
instabilities, the main contribution coming from the cryogenic stage. The
contamination on the E-mode spectrum does not significantly pollute the CMBP
signal and no specific data cleaning seems to be needed.
[22]
oai:arXiv.org:astro-ph/0401193 [pdf] - 62063
The Sky Polarization Observatory
Cortiglioni, S.;
Bernardi, G.;
Carretti, E.;
Casarini, L.;
Cecchini, S.;
Macculi, C.;
Ramponi, M.;
Sbarra, C.;
Monari, J.;
Orfei, A.;
Poloni, M.;
Poppi, S.;
Boella, G.;
Bonometto, S.;
Colombo, L.;
Gervasi, M.;
Sironi, G.;
Zannoni, M.;
Baralis, M.;
Peverini, O. A.;
Tascone, R.;
Virone, G.;
Fabbri, R.;
Natale, V.;
Nicastro, L.;
Ng, K-W.;
Vinyajkin, E. N.;
Razin, V. A.;
Sazhin, M. V.;
Strukov, I. A.;
Negri, B.
Submitted: 2004-01-12, last modified: 2004-01-14
SPOrt is an ASI-funded experiment specifically designed to measure the sky
polarization at 22, 32 and 90 GHz, which was selected in 1997 by ESA to be
flown on the International Space Station. Starting in 2006 and for at least 18
months, it will be taking direct and simultaneous measurements of the Stokes
parameters Q and U at 660 sky pixels, with FWHM=7 degrees. Due to development
efforts over the past few years, the design specifications have been
significantly improved with respect to the first proposal. Here we present an
up-to-date description of the instrument, which now warrants a pixel
sensitivity of 1.7 microK for the polarization of the cosmic background
radiation, assuming two years of observations. We discuss SPOrt scientific
goals in the light of WMAP results, in particular in connection with the
emerging double-reionization cosmological scenario.
[23]
oai:arXiv.org:astro-ph/0302276 [pdf] - 54903
An iterative destriping technique for diffuse background polarization
data
Submitted: 2003-02-14
We describe a simple but effective iterative procedure specifically designed
to destripe Q and U Stokes parameter data as those collected by the SPOrt
experiment onboard the International Space Station (ISS). The method is general
enough to be useful for other experiments, both in polarization and total
intensity. The only requirement for the algorithm to work properly is that the
receiver knee frequency must be lower than the signal modulation frequency,
corresponding in our case to the ISS orbit period. Detailed performances of the
technique are presented in the context of the SPOrt experiment, both in terms
of added rms noise and residual correlated noise.
[24]
oai:arXiv.org:astro-ph/0301020 [pdf] - 53991
The BaR-SPOrt Experiment
Zannoni, M.;
Cortiglioni, S.;
Bernardi, G.;
Carretti, E.;
Cecchini, S.;
Macculi, C.;
Morelli, E.;
Sbarra, C.;
Ventura, G.;
Nicastro, L.;
Monari, J.;
Poloni, M.;
Poppi, S.;
Natale, V.;
Baralis, M.;
Peverini, O.;
Tascone, R.;
Virone, G.;
Boscaleri, A.;
Pascale, E.;
Boella, G.;
Bonometto, S.;
Gervasi, M.;
Sironi, G.;
Tucci, M.;
Nesti, R.;
Fabbri, R.;
de Bernardis, P.;
De Petris, M.;
Masi, S.;
Sazhin, M. V.;
Vinyajkin, E. N.
Submitted: 2003-01-02
BaR-SPOrt (Balloon-borne Radiometers for Sky Polarisation Observations) is an
experiment to measure the linearly polarized emission of sky patches at 32 and
90 GHz with sub-degree angular resolution. It is equipped with high sensitivity
correlation polarimeters for simultaneous detection of both the U and Q stokes
parameters of the incident radiation. On-axis telescope is used to observe
angular scales where the expected polarization of the Cosmic Microwave
Background (CMBP) peaks. This project shares most of the know-how and
sophisticated technology developed for the SPOrt experiment onboard the
International Space Station. The payload is designed to flight onboard long
duration stratospheric balloons both in the Northern and Southern hemispheres
where low foreground emission sky patches are accessible. Due to the weakness
of the expected CMBP signal (in the range of microK), much care has been spent
to optimize the instrument design with respect to the systematics generation,
observing time efficiency and long term stability. In this contribution we
present the instrument design, and first tests on some components of the 32 GHz
radiometer.
[25]
oai:arXiv.org:astro-ph/0212067 [pdf] - 53457
SPOrt: an Experiment Aimed at Measuring the Large Scale Cosmic Microwave
Background Polarization
Carretti, E.;
Cortiglioni, S.;
Bernardi, G.;
Cecchini, S.;
Macculi, C.;
Sbarra, C.;
Monari, J.;
Orfei, A.;
Poloni, M.;
Poppi, S.;
Boella, G.;
Bonometto, S.;
Gervasi, M.;
Sironi, G.;
Zannoni, M.;
Tucci, M.;
Baralis, M.;
Peverini, O. A.;
Tascone, R.;
Virone, G.;
Fabbri, R.;
Nicastro, L.;
Ng, K. -W.;
Razin, V. A.;
Vinyajkin, E. N.;
Sazhin, M. V.;
Strukov, I. A.
Submitted: 2002-12-03
SPOrt (Sky Polarization Observatory) is a space experiment to be flown on the
International Space Station during Early Utilization Phase aimed at measuring
the microwave polarized emission with FWHM = 7deg, in the frequency range 22-90
GHz. The Galactic polarized emission can be observed at the lower frequencies
and the polarization of Cosmic Microwave Background (CMB) at 90 GHz, where
contaminants are expected to be less important. The extremely low level of the
CMB Polarization signal (< 1 uK) calls for intrinsically stable radiometers.
The SPOrt instrument is expressly devoted to CMB polarization measurements and
the whole design has been optimized for minimizing instrumental polarization
effects. In this contribution we present the receiver architecture based on
correlation techniques, the analysis showing its intrinsic stability and the
custom hardware development carried out to detect such a low signal.