Normalized to: Ma, P.
[1]
oai:arXiv.org:1909.12857 [pdf] - 2021218
Implications on the origin of cosmic rays in light of 10 TV spectral
softenings
Yue, Chuan;
Ma, Peng-Xiong;
Yuan, Qiang;
Fan, Yi-Zhong;
Chen, Zhan-Fang;
Cui, Ming-Yang;
Dai, Hao-Ting;
Dong, Tie-Kuang;
Huang, Xiaoyuan;
Jiang, Wei;
Lei, Shi-Jun;
Li, Xiang;
Liu, Cheng-Ming;
Liu, Hao;
Liu, Yang;
Luo, Chuan-Ning;
Pan, Xu;
Peng, Wen-Xi;
Qiao, Rui;
Wei, Yi-Feng;
Wu, Li-Bo;
Xu, Zhi-Hui;
Xu, Zun-Lei;
Yuan, Guan-Wen;
Zang, Jing-Jing;
Zhang, Ya-Peng;
Zhang, Yong-Jie;
Zhang, Yun-Long
Submitted: 2019-09-27, last modified: 2019-12-01
Precise measurements of the energy spectra of cosmic rays (CRs) show various
kinds of features deviating from single power-laws, which give very interesting
and important implications on their origin and propagation. Previous
measurements from a few balloon and space experiments indicate the existence of
spectral softenings around 10 TV for protons (and probably also for Helium
nuclei). Very recently, the DArk Matter Particle Explorer (DAMPE) measurement
about the proton spectrum clearly reveals such a softening with a high
significance. Here we study the implications of these new measurements, as well
as the groundbased indirect measurements, on the origin of CRs. We find that a
single component of CRs fails to fit the spectral softening and the air shower
experiment data simultaneously. In the framework of multiple components, we
discuss two possible scenarios, the multiple source population scenario and the
background plus nearby source scenario. Both scenarios give reasonable fits to
the wide-band data from TeV to 100 PeV energies. Considering the anisotropy
observations, the nearby source model is favored.
[2]
oai:arXiv.org:1909.12860 [pdf] - 1971488
Measurement of the cosmic-ray proton spectrum from 40 GeV to 100 TeV
with the DAMPE satellite
An, Q.;
Asfandiyarov, R.;
Azzarello, P.;
Bernardini, P.;
Bi, X. J.;
Cai, M. S.;
Chang, J.;
Chen, D. Y.;
Chen, H. F.;
Chen, J. L.;
Chen, W.;
Cui, M. Y.;
Cui, T. S.;
Dai, H. T.;
D'Amone, A.;
De Benedittis, A.;
De Mitri, I.;
Di Santo, M.;
Ding, M.;
Dong, T. K.;
Dong, Y. F.;
Dong, Z. X.;
Donvito, G.;
Droz, D.;
Duan, J. L.;
Duan, K. K.;
D'Urso, D.;
Fan, R. R.;
Fan, Y. Z.;
Fang, F.;
Feng, C. Q.;
Feng, L.;
Fusco, P.;
Gallo, V.;
Gan, F. J.;
Gao, M.;
Gargano, F.;
Gong, K.;
Gong, Y. Z.;
Guo, D. Y.;
Guo, J. H.;
Guo, X. L.;
Han, S. X.;
Hu, Y. M.;
Huang, G. S.;
Huang, X. Y.;
Huang, Y. Y.;
Ionica, M.;
Jiang, W.;
Jin, X.;
Kong, J.;
Lei, S. J.;
Li, S.;
Li, W. L.;
Li, X.;
Li, X. Q.;
Li, Y.;
Liang, Y. F.;
Liang, Y. M.;
Liao, N. H.;
Liu, C. M.;
Liu, H.;
Liu, J.;
Liu, S. B.;
Liu, W. Q.;
Liu, Y.;
Loparco, F.;
Luo, C. N.;
Ma, M.;
Ma, P. X.;
Ma, S. Y.;
Ma, T.;
Ma, X. Y.;
Marsella, G.;
Mazziotta, M. N.;
Mo, D.;
Niu, X. Y.;
Pan, X.;
Peng, W. X.;
Peng, X. Y.;
Qiao, R.;
Rao, J. N.;
Salinas, M. M.;
Shang, G. Z.;
Shen, W. H.;
Shen, Z. Q.;
Shen, Z. T.;
Song, J. X.;
Su, H.;
Su, M.;
Sun, Z. Y.;
Surdo, A.;
Teng, X. J.;
Tykhonov, A.;
Vitillo, S.;
Wang, C.;
Wang, H.;
Wang, H. Y.;
Wang, J. Z.;
Wang, L. G.;
Wang, Q.;
Wang, S.;
Wang, X. H.;
Wang, X. L.;
Wang, Y. F.;
Wang, Y. P.;
Wang, Y. Z.;
Wang, Z. M.;
Wei, D. M.;
Wei, J. J.;
Wei, Y. F.;
Wen, S. C.;
Wu, D.;
Wu, J.;
Wu, L. B.;
Wu, S. S.;
Wu, X.;
Xi, K.;
Xia, Z. Q.;
Xu, H. T.;
Xu, Z. H.;
Xu, Z. L.;
Xu, Z. Z.;
Xue, G. F.;
Yang, H. B.;
Yang, P.;
Yang, Y. Q.;
Yang, Z. L.;
Yao, H. J.;
Yu, Y. H.;
Yuan, Q.;
Yue, C.;
Zang, J. J.;
Zhang, F.;
Zhang, J. Y.;
Zhang, J. Z.;
Zhang, P. F.;
Zhang, S. X.;
Zhang, W. Z.;
Zhang, Y.;
Zhang, Y. J.;
Zhang, Y. L.;
Zhang, Y. P.;
Zhang, Y. Q.;
Zhang, Z.;
Zhang, Z. Y.;
Zhao, H.;
Zhao, H. Y.;
Zhao, X. F.;
Zhou, C. Y.;
Zhou, Y.;
Zhu, X.;
Zhu, Y.;
Zimmer, S.
Submitted: 2019-09-27, last modified: 2019-09-30
The precise measurement of the spectrum of protons, the most abundant
component of the cosmic radiation, is necessary to understand the source and
acceleration of cosmic rays in the Milky Way. This work reports the measurement
of the cosmic ray proton fluxes with kinetic energies from 40 GeV to 100 TeV,
with two and a half years of data recorded by the DArk Matter Particle Explorer
(DAMPE). This is the first time an experiment directly measures the cosmic ray
protons up to ~100 TeV with a high statistics. The measured spectrum confirms
the spectral hardening found by previous experiments and reveals a softening at
~13.6 TeV, with the spectral index changing from ~2.60 to ~2.85. Our result
suggests the existence of a new spectral feature of cosmic rays at energies
lower than the so-called knee, and sheds new light on the origin of Galactic
cosmic rays.
[3]
oai:arXiv.org:1802.06727 [pdf] - 1947101
Photonic mid-infrared nulling for exoplanet detection on a planar
chalcogenide platform
Submitted: 2018-02-16, last modified: 2019-08-20
The future of exoplanet detection lies in the mid-infrared (MIR). The MIR
region contains the blackbody peak of both hot and habitable zone exoplanets,
making the contrast between starlight and planet light less extreme. It is also
the region where prominent chemical signatures indicative of life exist, such
as ozone at 9.7 microns. At a wavelength of 4 microns the difference in
emission between an Earth-like planet and a star like our own is 80 dB. However
a jovian planet, at the same separation exhibits 60 dB of contrast, or only 20
dB if it is hot due to its formation energy or being close to its host star. A
two dimensional nulling interferometer, made with chalcogenide glass, has been
measured to produce a null of 20 dB, limited by scattered light. Measures to
increase the null depth to the theoretical limit of 60 dB are discussed.
[4]
oai:arXiv.org:1907.02173 [pdf] - 1910775
The on-orbit calibration of DArk Matter Particle Explorer
Ambrosi, G.;
An, Q.;
Asfandiyarov, R.;
Azzarello, P.;
Bernardini, P.;
Cai, M. S.;
Caragiulo, M.;
Chang, J.;
Chen, D. Y.;
Chen, H. F.;
Chen, J. L.;
Chen, W.;
Cui, M. Y.;
Cui, T. S.;
Dai, H. T.;
D'Amone, A.;
De Benedittis, A.;
De Mitri, I.;
Ding, M.;
Di Santo, M.;
Dong, J. N.;
Dong, T. K.;
Dong, Y. F.;
Dong, Z. X.;
Droz, D.;
Duan, K. K.;
Duan, J. L.;
D'Urso, D.;
Fan, R. R.;
Fan, Y. Z.;
Fang, F.;
Feng, C. Q.;
Feng, L.;
Fusco, P.;
Gallo, V.;
Gan, F. J.;
Gao, M.;
Gao, S. S.;
Gargano, F.;
Garrappa, S.;
Gong, K.;
Gong, Y. Z.;
Guo, J. H.;
Hu, Y. M.;
Huang, G. S.;
Huang, Y. Y.;
Ionica, M.;
Jiang, D.;
Jiang, W.;
Jin, X.;
Kong, J.;
Lei, S. J.;
Li, S.;
Li, X.;
Li, W. L.;
Li, Y.;
Liang, Y. F.;
Liang, Y. M.;
Liao, N. H.;
Liu, C. M.;
Liu, H.;
Liu, J.;
Liu, S. B.;
Liu, W. Q.;
Liu, Y.;
Loparco, F.;
Ma, M.;
Ma, P. X.;
Ma, S. Y.;
Ma, T.;
Ma, X. Q.;
Ma, X. Y.;
Marsella, G.;
Mazziotta, M. N.;
Mo, D.;
Niu, X. Y.;
Pan, X.;
Peng, X. Y.;
Peng, W. X.;
Qiao, R.;
Rao, J. N.;
Salinas, M. M.;
Shang, G. Z.;
Shen, W. H.;
Shen, Z. Q.;
Shen, Z. T.;
Song, J. X.;
Su, H.;
Su, M.;
Sun, Z. Y.;
Surdo, A.;
Teng, X. J.;
Tian, X. B.;
Tykhonov, A.;
Vitillo, S.;
Wang, C.;
Wang, H.;
Wang, H. Y.;
Wang, J. Z.;
Wang, L. G.;
Wang, Q.;
Wang, S.;
Wang, X. H.;
Wang, X. L.;
Wang, Y. F.;
Wang, Y. P.;
Wang, Y. Z.;
Wang, Z. M.;
Wen, S. C.;
Wei, D. M.;
Wei, J. J.;
Wei, Y. F.;
Wu, D.;
Wu, J.;
Wu, L. B.;
Wu, S. S.;
Wu, X.;
Xi, K.;
Xia, Z. Q.;
Xin, Y. L.;
Xu, H. T.;
Xu, Z. H.;
Xu, Z. L.;
Xu, Z. Z.;
Xue, G. F.;
Yang, H. B.;
Yang, P.;
Yang, Y. Q.;
Yang, Z. L.;
Yao, H. J.;
Yu, Y. H.;
Yuan, Q.;
Yue, C.;
Zang, J. J.;
Zhang, D. L.;
Zhang, F.;
Zhang, J. B.;
Zhang, J. Y.;
Zhang, J. Z.;
Zhang, L.;
Zhang, P. F.;
Zhang, S. X.;
Zhang, W. Z.;
Zhang, Y.;
Zhang, Y. J.;
Zhang, Y. Q.;
Zhang, Y. L.;
Zhang, Y. P.;
Zhang, Z.;
Zhang, Z. Y.;
Zhao, H.;
Zhao, H. Y.;
Zhao, X. F.;
Zhou, C. Y.;
Zhou, Y.;
Zhu, X.;
Zhu, Y.;
Zimmer, S.
Submitted: 2019-07-03
The DArk Matter Particle Explorer (DAMPE), a satellite-based cosmic ray and
gamma-ray detector, was launched on December 17, 2015, and began its on-orbit
operation on December 24, 2015. In this work we document the on-orbit
calibration procedures used by DAMPE and report the calibration results of the
Plastic Scintillator strip Detector (PSD), the Silicon-Tungsten
tracKer-converter (STK), the BGO imaging calorimeter (BGO), and the Neutron
Detector (NUD). The results are obtained using Galactic cosmic rays, bright
known GeV gamma-ray sources, and charge injection into the front-end
electronics of each sub-detector. The determination of the boundary of the
South Atlantic Anomaly (SAA), the measurement of the live time, and the
alignments of the detectors are also introduced. The calibration results
demonstrate the stability of the detectors in almost two years of the on-orbit
operation.
[5]
oai:arXiv.org:1810.10784 [pdf] - 1773631
Charge Measurement of Cosmic Ray Nuclei with the Plastic Scintillator
Detector of DAMPE
Dong, Tiekuang;
Zhang, Yapeng;
Ma, Pengxiong;
Zhang, Yongjie;
Bernardini, Paolo;
Ding, Meng;
Guo, Dongya;
Lei, Shijun;
Li, Xiang;
De Mitri, Ivan;
Peng, Wenxi;
Qiao, Rui;
Di Santo, Margherita;
Sun, Zhiyu;
Surdo, Antonio;
Wang, Zhaomin;
Wu, Jian;
Xu, Zunlei;
Yu, Yuhong;
Yuan, Qiang;
Yue, Chuan;
Zang, Jingjing;
Zhang, Yunlong
Submitted: 2018-10-25
One of the main purposes of the DArk Matter Particle Explorer (DAMPE) is to
measure the cosmic ray nuclei up to several tens of TeV or beyond, whose origin
and propagation remains a hot topic in astrophysics. The Plastic Scintillator
Detector (PSD) on top of DAMPE is designed to measure the charges of cosmic ray
nuclei from H to Fe and serves as a veto detector for discriminating gamma-rays
from charged particles. We propose in this paper a charge reconstruction
procedure to optimize the PSD performance in charge measurement. Essentials of
our approach, including track finding, alignment of PSD, light attenuation
correction, quenching and equalization correction are described detailedly in
this paper after a brief description of the structure and operational principle
of the PSD. Our results show that the PSD works very well and almost all the
elements in cosmic rays from H to Fe are clearly identified in the charge
spectrum.
[6]
oai:arXiv.org:1810.09901 [pdf] - 1859905
Calibration of the DAMPE Plastic Scintillator Detector and its on-orbit
performance
Ding, Meng;
Zhang, Yapeng;
Zhang, Yong-Jie;
Wang, Yuan-Peng;
Dong, Tie-Kuang;
De Benedittis, Antonio;
Bernardini, Paolo;
Fang, Fang;
Li, Yao;
Liu, Jie;
Ma, Peng-Xiong;
Sun, Zhi-Yu;
Gallo, Valentina;
Vitillo, Stefania;
Wang, Zhao-Min;
Yu, Yu-Hong;
Yue, Chuan;
Yuan, Qiang;
Zhou, Yong;
Zhang, Yun-Long
Submitted: 2018-10-23
DArk Matter Particle Explorer (DAMPE) is a space-borne apparatus for
detecting the high-energy cosmic-rays like electrons, $\gamma$-rays, protons
and heavy-ions. Plastic Scintillator Detector (PSD) is the top-most
sub-detector of the DAMPE. The PSD is designed to measure the charge of
incident high-energy particles and it also serves as a veto detector for
discriminating $\gamma$-rays from charged particles. In this paper, PSD
on-orbit calibration procedure is described, which includes five steps of
pedestal, dynode correlation, response to minimum-ionizing particles (MIPs),
light attenuation function and energy reconstruction. A method for
reconstructing the charge of incident high energy cosmic-ray particles is
introduced. The detection efficiency of each PSD strip is verified to be above
99.5%, the total efficiency of the PSD for charged particles is above 99.99%.
[7]
oai:arXiv.org:1808.05720 [pdf] - 1901739
A Method of Alignment of the Plastic Scintillator Detector of DAMPE
Ma, Peng-Xiong;
Zhang, Yong-Jie;
Zhang, Ya-Peng;
Li, Yao;
Zang, Jing-Jing;
Li, Xiang;
Dong, Tie-Kuang;
Fan, Yi-Zhong;
Lei, Shi-Jun;
Wu, Jian;
Yu, Yu-Hong;
Yuan, Qiang;
Yue, Chuan;
Sun, Zhi-Yu
Submitted: 2018-08-16, last modified: 2018-08-20
The Plastic Scintillator Detector (PSD) of the DArk Matter Particle Explorer
(DAMPE) is designed to measure cosmic ray charge (Z) and to act as a veto
detector for gamma-ray identification. In order to fully exploit the charge
identification potential of the PSD and to enhance its capability to identify
the gamma ray events, we develop a PSD detector alignment method. The path
length of a given track in the volume of a PSD bar is derived taking into
account the shift and rotation alignment corrections. By examining energy
spectra of corner-passing events and fully contained events, position shifts
and rotations of all PSD bars are obtained, and found to be on average about
1mm and 0.0015 radian respectively. To validate the alignment method, we
introduce the artificial shifts and rotations of PSD bars in the detector
simulation. These shift and rotation parameters can be recovered successfully
by the alignment procedure. As a result of the PSD alignment procedure, the
charge resolution of the PSD is improved from $4\%$ to $8\%$ depending on the
nuclei.
[8]
oai:arXiv.org:1711.05565 [pdf] - 1686668
GW170817 and the prospect of forming supramassive remnants in neutron
star mergers
Submitted: 2017-11-15, last modified: 2018-04-05
The gravitational wave data of GW170817 favor the equation of state (EoS)
models that predict compact neutron stars (NSs), consistent with the radius
constraints from X-ray observations. Motivated by such a remarkable progress,
we examine the fate of the remnants formed in NS mergers and focus on the roles
of the angular momentum and the mass distribution of the binary NSs. In the
mass shedding limit (for which the dimensionless angular momentum equals to the
Keplerian value, i.e., $j=j_{\rm Kep}$), the adopted { seven EoS models, except
H4 and ALF2,} yield supramassive NSs in more than half of the mergers. However,
for $j\lesssim 0.7j_{\rm Kep}$, the presence or absence of a non-negligible
fraction of supramassive NSs formed in the mergers depends sensitively on both
the EoS and the mass distribution of the binary systems. The NS mergers with a
total gravitational mass $\leq 2.6M_\odot$ are found to be able to shed
valuable light on both the EoS model and the angular momentum of the remnants
if supramassive NSs are still absent. We have also discussed the uncertainty on
estimating the maximum gravitational mass of non-rotating NSs ($M_{\rm max}$)
due to the unknown $j$ of the pre-collapse remnants. With the data of GW170817
and the assumption of the mass loss of $0.03M_\odot$, we have $M_{\rm
max}<(2.19,~2.32)M_\odot$ (90\% confidence level) for $j=(1.0,~0.8)j_{\rm
Kep}$, respectively.
[9]
oai:arXiv.org:1711.10981 [pdf] - 1600918
Direct detection of a break in the teraelectronvolt cosmic-ray spectrum
of electrons and positrons
Ambrosi, G.;
An, Q.;
Asfandiyarov, R.;
Azzarello, P.;
Bernardini, P.;
Bertucci, B.;
Cai, M. S.;
Chang, J.;
Chen, D. Y.;
Chen, H. F.;
Chen, J. L.;
Chen, W.;
Cui, M. Y.;
Cui, T. S.;
D'Amone, A.;
De Benedittis, A.;
De Mitri, I.;
Di Santo, M.;
Dong, J. N.;
Dong, T. K.;
Dong, Y. F.;
Dong, Z. X.;
Donvito, G.;
Droz, D.;
Duan, K. K.;
Duan, J. L.;
Duranti, M.;
D'Urso, D.;
Fan, R. R.;
Fan, Y. Z.;
Fang, F.;
Feng, C. Q.;
Feng, L.;
Fusco, P.;
Gallo, V.;
Gan, F. J.;
Gao, M.;
Gao, S. S.;
Gargano, F.;
Garrappa, S.;
Gong, K.;
Gong, Y. Z.;
Guo, D. Y.;
Guo, J. H.;
Hu, Y. M.;
Huang, G. S.;
Huang, Y. Y.;
Ionica, M.;
Jiang, D.;
Jiang, W.;
Jin, X.;
Kong, J.;
Lei, S. J.;
Li, S.;
Li, X.;
Li, W. L.;
Li, Y.;
Liang, Y. F.;
Liang, Y. M.;
Liao, N. H.;
Liu, H.;
Liu, J.;
Liu, S. B.;
Liu, W. Q.;
Liu, Y.;
Loparco, F.;
Ma, M.;
Ma, P. X.;
Ma, S. Y.;
Ma, T.;
Ma, X. Q.;
Ma, X. Y.;
Marsella, G.;
Mazziotta, M. N.;
Mo, D.;
Niu, X. Y.;
Peng, X. Y.;
Peng, W. X.;
Qiao, R.;
Rao, J. N.;
Salinas, M. M.;
Shang, G. Z.;
Shen, W. H.;
Shen, Z. Q.;
Shen, Z. T.;
Song, J. X.;
Su, H.;
Su, M.;
Sun, Z. Y.;
Surdo, A.;
Teng, X. J.;
Tian, X. B.;
Tykhonov, A.;
Vagelli, V.;
Vitillo, S.;
Wang, C.;
Wang, H.;
Wang, H. Y.;
Wang, J. Z.;
Wang, L. G.;
Wang, Q.;
Wang, S.;
Wang, X. H.;
Wang, X. L.;
Wang, Y. F.;
Wang, Y. P.;
Wang, Y. Z.;
Wen, S. C.;
Wang, Z. M.;
Wei, D. M.;
Wei, J. J.;
Wei, Y. F.;
Wu, D.;
Wu, J.;
Wu, L. B.;
Wu, S. S.;
Wu, X.;
Xi, K.;
Xia, Z. Q.;
Xin, Y. L.;
Xu, H. T.;
Xu, Z. L.;
Xu, Z. Z.;
Xue, G. F.;
Yang, H. B.;
Yang, P.;
Yang, Y. Q.;
Yang, Z. L.;
Yao, H. J.;
Yu, Y. H.;
Yuan, Q.;
Yue, C.;
Zang, J. J.;
Zhang, C.;
Zhang, D. L.;
Zhang, F.;
Zhang, J. B.;
Zhang, J. Y.;
Zhang, J. Z.;
Zhang, L.;
Zhang, P. F.;
Zhang, S. X.;
Zhang, W. Z.;
Zhang, Y.;
Zhang, Y. J.;
Zhang, Y. Q.;
Zhang, Y. L.;
Zhang, Y. P.;
Zhang, Z.;
Zhang, Z. Y.;
Zhao, H.;
Zhao, H. Y.;
Zhao, X. F.;
Zhou, C. Y.;
Zhou, Y.;
Zhu, X.;
Zhu, Y.;
Zimmer, S.
Submitted: 2017-11-29
High energy cosmic ray electrons plus positrons (CREs), which lose energy
quickly during their propagation, provide an ideal probe of Galactic
high-energy processes and may enable the observation of phenomena such as
dark-matter particle annihilation or decay. The CRE spectrum has been directly
measured up to $\sim 2$ TeV in previous balloon- or space-borne experiments,
and indirectly up to $\sim 5$ TeV by ground-based Cherenkov $\gamma$-ray
telescope arrays. Evidence for a spectral break in the TeV energy range has
been provided by indirect measurements of H.E.S.S., although the results were
qualified by sizeable systematic uncertainties. Here we report a direct
measurement of CREs in the energy range $25~{\rm GeV}-4.6~{\rm TeV}$ by the
DArk Matter Particle Explorer (DAMPE) with unprecedentedly high energy
resolution and low background. The majority of the spectrum can be properly
fitted by a smoothly broken power-law model rather than a single power-law
model. The direct detection of a spectral break at $E \sim0.9$ TeV confirms the
evidence found by H.E.S.S., clarifies the behavior of the CRE spectrum at
energies above 1 TeV and sheds light on the physical origin of the sub-TeV
CREs.
[10]
oai:arXiv.org:1711.10989 [pdf] - 1595331
Interpretations of the DAMPE electron data
Yuan, Qiang;
Feng, Lei;
Yin, Peng-Fei;
Fan, Yi-Zhong;
Bi, Xiao-Jun;
Cui, Ming-Yang;
Dong, Tie-Kuang;
Guo, Yi-Qing;
Fang, Kun;
Hu, Hong-Bo;
Huang, Xiaoyuan;
Lei, Shi-Jun;
Li, Xiang;
Lin, Su-Jie;
Liu, Hao;
Ma, Peng-Xiong;
Peng, Wen-Xi;
Qiao, Rui;
Shen, Zhao-Qiang;
Su, Meng;
Wei, Yi-Feng;
Xu, Zun-Lei;
Yue, Chuan;
Zang, Jing-Jing;
Zhang, Cun;
Zhang, Xinmin;
Zhang, Ya-Peng;
Zhang, Yong-Jie;
Zhang, Yun-Long
Submitted: 2017-11-29
The DArk Matter Particle Explorer (DAMPE), a high energy cosmic ray and
$\gamma$-ray detector in space, has recently reported the new measurement of
the total electron plus positron flux between 25 GeV and 4.6 TeV. A spectral
softening at $\sim0.9$ TeV and a tentative peak at $\sim1.4$ TeV have been
reported. We study the physical implications of the DAMPE data in this work.
The presence of the spectral break significantly tightens the constraints on
the model parameters to explain the electron/positron excesses. The spectral
softening can either be explained by the maximum acceleration limits of
electrons by astrophysical sources, or a breakdown of the common assumption of
continuous distribution of electron sources at TeV energies in space and time.
The tentive peak at $\sim1.4$ TeV implies local sources of electrons/positrons
with quasi-monochromatic injection spectrum. We find that the cold,
ultra-relativistic $e^+e^-$ winds from pulsars may give rise to such a
structure. The pulsar is requird to be middle-aged, relatively slowly-rotated,
mildly magnetized, and isolated in a density cavity. The annihilation of DM
particles ($m_{\chi}\sim1.5$ TeV) into $e^+e^-$ pairs in a nearby clump or an
over-density region may also explain the data. In the DM scenario, the inferred
clump mass (or density enhancement) is about $10^7-10^8$ M$_\odot$ (or $17-35$
times of the canonical local density) assuming a thermal production cross
section, which is relatively extreme compared with the expectation from
numerical simulations. A moderate enhancement of the annihilation cross section
via, e.g., the Sommerfeld mechanism or non-thermal production, is thus needed.
[11]
oai:arXiv.org:1706.08453 [pdf] - 1585147
The DArk Matter Particle Explorer mission
Chang, J.;
Ambrosi, G.;
An, Q.;
Asfandiyarov, R.;
Azzarello, P.;
Bernardini, P.;
Bertucci, B.;
Cai, M. S.;
Caragiulo, M.;
Chen, D. Y.;
Chen, H. F.;
Chen, J. L.;
Chen, W.;
Cui, M. Y.;
Cui, T. S.;
D'Amone, A.;
De Benedittis, A.;
De Mitri, I.;
Di Santo, M.;
Dong, J. N.;
Dong, T. K.;
Dong, Y. F.;
Dong, Z. X.;
Donvito, G.;
Droz, D.;
Duan, K. K.;
Duan, J. L.;
Duranti, M.;
D'Urso, D.;
Fan, R. R.;
Fan, Y. Z.;
Fang, F.;
Feng, C. Q.;
Feng, L.;
Fusco, P.;
Gallo, V.;
Gan, F. J.;
Gan, W. Q.;
Gao, M.;
Gao, S. S.;
Gargano, F.;
Gong, K.;
Gong, Y. Z.;
Guo, J. H.;
Hu, Y. M.;
Huang, G. S.;
Huang, Y. Y.;
Ionica, M.;
Jiang, D.;
Jiang, W.;
Jin, X.;
Kong, J.;
Lei, S. J.;
Li, S.;
Li, X.;
Li, W. L.;
Li, Y.;
Liang, Y. F.;
Liang, Y. M.;
Liao, N. H.;
Liu, Q. Z.;
Liu, H.;
Liu, J.;
Liu, S. B.;
Liu, Q. Z.;
Liu, W. Q.;
Liu, Y.;
Loparco, F.;
Lü, J.;
Ma, M.;
Ma, P. X.;
Ma, S. Y.;
Ma, T.;
Ma, X. Q.;
Ma, X. Y.;
Marsella, G.;
Mazziotta, M. N.;
Mo, D.;
Miao, T. T.;
Niu, X. Y.;
Pohl, M.;
Peng, X. Y.;
Peng, W. X.;
Qiao, R.;
Rao, J. N.;
Salinas, M. M.;
Shang, G. Z.;
Shen, W. H.;
Shen, Z. Q.;
Shen, Z. T.;
Song, J. X.;
Su, H.;
Su, M.;
Sun, Z. Y.;
Surdo, A.;
Teng, X. J.;
Tian, X. B.;
Tykhonov, A.;
Vagelli, V.;
Vitillo, S.;
Wang, C.;
Wang, Chi;
Wang, H.;
Wang, H. Y.;
Wang, J. Z.;
Wang, L. G.;
Wang, Q.;
Wang, S.;
Wang, X. H.;
Wang, X. L.;
Wang, Y. F.;
Wang, Y. P.;
Wang, Y. Z.;
Wen, S. C.;
Wang, Z. M.;
Wei, D. M.;
Wei, J. J.;
Wei, Y. F.;
Wu, D.;
Wu, J.;
Wu, S. S.;
Wu, X.;
Xi, K.;
Xia, Z. Q.;
Xin, Y. L.;
Xu, H. T.;
Xu, Z. L.;
Xu, Z. Z.;
Xue, G. F.;
Yang, H. B.;
Yang, J.;
Yang, P.;
Yang, Y. Q.;
Yang, Z. L.;
Yao, H. J.;
Yu, Y. H.;
Yuan, Q.;
Yue, C.;
Zang, J. J.;
Zhang, C.;
Zhang, D. L.;
Zhang, F.;
Zhang, J. B.;
Zhang, J. Y.;
Zhang, J. Z.;
Zhang, L.;
Zhang, P. F.;
Zhang, S. X.;
Zhang, W. Z.;
Zhang, Y.;
Zhang, Y. J.;
Zhang, Y. Q.;
Zhang, Y. L.;
Zhang, Y. P.;
Zhang, Z.;
Zhang, Z. Y.;
Zhao, H.;
Zhao, H. Y.;
Zhao, X. F.;
Zhou, C. Y.;
Zhou, Y.;
Zhu, X.;
Zhu, Y.;
Zimmer, S.
Submitted: 2017-06-26, last modified: 2017-09-14
The DArk Matter Particle Explorer (DAMPE), one of the four scientific space
science missions within the framework of the Strategic Pioneer Program on Space
Science of the Chinese Academy of Sciences, is a general purpose high energy
cosmic-ray and gamma-ray observatory, which was successfully launched on
December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE
scientific objectives include the study of galactic cosmic rays up to $\sim 10$
TeV and hundreds of TeV for electrons/gammas and nuclei respectively, and the
search for dark matter signatures in their spectra. In this paper we illustrate
the layout of the DAMPE instrument, and discuss the results of beam tests and
calibrations performed on ground. Finally we present the expected performance
in space and give an overview of the mission key scientific goals.
[12]
oai:arXiv.org:1611.05135 [pdf] - 1532653
Testing the dark matter subhalo hypothesis of the gamma-ray source 3FGL
J2212.5+0703
Wang, Yuan-Peng;
Duan, Kai-Kai;
Ma, Peng-Xiong;
Liang, Yun-Feng;
Shen, Zhao-Qiang;
Li, Shang;
Yue, Chuan;
Yuan, Qiang;
Zang, Jing-Jing;
Fan, Yi-Zhong;
Chang, Jin
Submitted: 2016-11-15
N-body simulations predict that galaxies at the Milky Way scale host a large
number of dark matter (DM) subhalos. Some of these subhalos, if they are
massive enough or close enough to the Earth, might be detectable in $\gamma$
rays due to the DM annihilation. 3FGL J2212.5+0703, an unidentified gamma-ray
source, has been suggested to be the counterpart candidate of a DM subhalo by
Bertoni et al. (2015, 2016). In this work we analyze the Fermi-LAT Pass 8 data
of 3FGL J2212.5+0703 to independently test the DM subhalo hypothesis of this
source. In order to suppress the possible contamination from two nearby
very-bright blazars, we just take into account the front-converting gamma-rays
which have better angular resolutions than that of the back-converting photons.
In addition to the spatial distribution analysis, we have extended the spectrum
analysis down to the energies of $\sim 100$ MeV, and thoroughly examined the
variability of the emission during the past 8 years. We confirm that 3FGL
J2212.5+0703 is a steady and spatially-extended gamma-ray emitter at a high
confidence level. The spectrum is well consistent with that expected from DM
annihilation into $b\bar{b}$. The introduction of a phenomenological
LogParabola spectrum just improves the fit slightly. All these results suggest
that 3FGL J2212.5+0703 could be indicative of a DM subhalo.
[13]
oai:arXiv.org:1608.04438 [pdf] - 1457609
Chalcogenide glass planar MIR couplers for future chip based Bracewell
interferometers
Goldsmith, Harry-Dean Kenchington;
Cvetojevic, Nick;
Ireland, Michael;
Ma, Pan;
Tuthill, Peter;
Eggleton, Ben;
Lawrence, John S.;
Debbarma, Sukanta;
Luther-Davies, Barry;
Madden, Stephen J.
Submitted: 2016-08-15
Photonic integrated circuits are established as the technique of choice for a
number of astronomical processing functions due to their compactness, high
level of integration, low losses, and stability. Temperature control,
mechanical vibration and acoustic noise become controllable for such a device
enabling much more complex processing than can realistically be considered with
bulk optics. To date the benefits have mainly been at wavelengths around 1550
nm but in the important Mid-Infrared region, standard photonic chips absorb
light strongly. Chalcogenide glasses are well known for their transparency to
beyond 10000 nm, and the first results from coupler devices intended for use in
an interferometric nuller for exoplanetary observation in the Mid-Infrared L
band (3800-4200 nm) are presented here showing that suitable performance can be
obtained both theoretically and experimentally for the first fabricated devices
operating at 4000 nm.
[14]
oai:arXiv.org:1407.4246 [pdf] - 1215702
Examination of the role of the $^{14}$O($\alpha$,$p$)$^{17}$F reaction
rate in type I x-ray bursts
Hu, J.;
He, J. J.;
Parikh, A.;
Xu, S. W.;
Yamaguchi, H.;
Kahl, D.;
Ma, P.;
Su, J.;
Wang, H. W.;
Nakao, T.;
Wakabayashi, Y.;
Teranishi, T.;
Hahn, K. I.;
Moon, J. Y.;
Jung, H. S.;
Hashimoto, T.;
Chen, A. A.;
Irvine, D.;
Lee, C. S.;
Kubono, S.
Submitted: 2014-07-16
The $^{14}$O($\alpha$,$p$)$^{17}$F reaction is one of the key reactions
involved in the breakout from the hot-CNO cycle to the rp-process in type I
x-ray bursts (XRBs). The resonant properties in the compound nucleus $^{18}$Ne
have been investigated through resonant elastic scattering of $^{17}$F+$p$. The
radioactive $^{17}$F beam was separated by the CNS Radioactive Ion Beam
separator (CRIB) and bombarded a thick H$_2$ gas target at 3.6 MeV/nucleon. The
recoiling light particles were measured by three ${\Delta}$E-E silicon
telescopes at laboratory angles of $\theta$$_{lab}$$\approx$3$^\circ$,
10$^\circ$ and 18$^\circ$, respectively. Five resonances at $E_{x}$=6.15, 6.28,
6.35, 6.85, and 7.05 MeV were observed in the excitation functions, and their
spin-parities have been determined based on an $R$-matrix analysis. In
particular, $J^{\pi}$=1$^-$ was firmly assigned to the 6.15-MeV state which
dominates the thermonuclear $^{14}$O($\alpha$,$p$)$^{17}$F rate below 2 GK. As
well, a possible new excited state in $^{18}$Ne was observed at
$E_{x}$=6.85$\pm$0.11 MeV with tentative $J$=0 assignment. This state could be
the analog state of the 6.880 MeV (0$^{-}$) level in the mirror nucleus
$^{18}$O, or a bandhead state (0$^+$) of the six-particle four-hole (6$p$-4$h$)
band. A new thermonuclear $^{14}$O($\alpha$,$p$)$^{17}$F rate has been
determined, and the astrophysical impact of multiple recent rates has been
examined using an XRB model. Contrary to previous expectations, we find only
modest impact on predicted nuclear energy generation rates from using reaction
rates differing by up to several orders of magnitude.
[15]
oai:arXiv.org:1403.4668 [pdf] - 1208460
Investigation of thermonuclear $^{18}$Ne($\alpha$,$p$)$^{21}$Na rate via
resonant elastic scattering of $^{21}$Na+$p$
Zhang, L. Y.;
He, J. J.;
Parikh, A.;
Xu, S. W.;
Yamaguchi, H.;
Kahl, D.;
Kubono, S.;
Mohr, P.;
Hu, J.;
Ma, P.;
Chen, S. Z.;
Wakabayashi, Y.;
Wang, H. W.;
Tian, W. D.;
Chen, R. F.;
Guo, B.;
Hashimoto, T.;
Togano, Y.;
Hayakawa, S.;
Teranishi, T.;
Iwasa, N.;
Yamada, T.;
Komatsubara, T.;
Zhang, Y. H.;
Zhou, X. H.
Submitted: 2014-03-18
The $^{18}$Ne($\alpha$,$p$)$^{21}$Na reaction is thought to be one of the key
breakout reactions from the hot CNO cycles to the rp-process in type I x-ray
bursts. In this work, the resonant properties of the compound nucleus $^{22}$Mg
have been investigated by measuring the resonant elastic scattering of
$^{21}$Na+$p$. An 89 MeV $^{21}$Na radioactive beam delivered from the CNS
Radioactive Ion Beam Separator bombarded an 8.8 mg/cm$^2$ thick polyethylene
(CH$_{2}$)$_{n}$ target. The $^{21}$Na beam intensity was about
2$\times$10$^{5}$ pps, with a purity of about 70% on target. The recoiled
protons were measured at the center-of-mass scattering angles of
$\theta_{c.m.}$$\approx$175.2${^\circ}$, 152.2${^\circ}$, and 150.5${^\circ}$
by three sets of $\Delta E$-$E$ telescopes, respectively. The excitation
function was obtained with the thick-target method over energies
$E_x$($^{22}$Mg)=5.5--9.2 MeV. In total, 23 states above the proton-threshold
in $^{22}$Mg were observed, and their resonant parameters were determined via
an $R$-matrix analysis of the excitation functions. We have made several new
$J^{\pi}$ assignments and confirmed some tentative assignments made in previous
work. The thermonuclear $^{18}$Ne($\alpha$,$p$)$^{21}$Na rate has been
recalculated based on our recommended spin-parity assignments. The
astrophysical impact of our new rate has been investigated through one-zone
postprocessing x-ray burst calculations. We find that the
$^{18}$Ne($\alpha$,$p$)$^{21}$Na rate significantly affects the peak nuclear
energy generation rate, reaction fluxes, as well as the onset temperature of
this breakout reaction in these astrophysical phenomena.
[16]
oai:arXiv.org:1301.4283 [pdf] - 1159130
The 18Ne(a,p)21Na breakout reaction in x-ray bursts: experimental
determination of spin-parities for alpha resonances in 22Mg via resonant
elastic scattering of 21Na+p
He, J. J.;
Zhang, L. Y.;
Parikh, A.;
Xu, S. W.;
Yamaguchi, H.;
Kahl, D.;
Kubono, S.;
Hu, J.;
Ma, P.;
Chen, S. Z.;
Wakabayashi, Y.;
Sun, B. H.;
Wang, H. W.;
Tian, W. D.;
Chen, R. F.;
Guo, B.;
Hashimoto, T.;
Togano, Y.;
Hayakawa, S.;
Teranishi, T.;
Iwasa, N.;
Yamada, T.;
Komatsubara, T.
Submitted: 2013-01-17, last modified: 2013-07-22
The $^{18}$Ne($\alpha$,$p$)$^{21}$Na reaction provides a pathway for breakout
from the hot CNO cycles to the $rp$-process in type I x-ray bursts. To better
determine this astrophysical reaction rate, the resonance parameters of the
compound nucleus $^{22}$Mg have been investigated by measuring the resonant
elastic scattering of $^{21}$Na+$p$. An 89 MeV $^{21}$Na radioactive ion beam
was produced at the CNS Radioactive Ion Beam Separator and bombarded an 8.8
mg/cm$^2$ thick polyethylene target. The recoiled protons were measured at
scattering angles of $\theta_{c.m.}$$\approx 175 {^\circ}$ and 152${^\circ}$ by
three $\Delta E$-$E$ silicon telescopes. The excitation function was obtained
with a thick-target method over energies $E_x$($^{22}$Mg)=5.5--9.2 MeV. The
resonance parameters have been determined through an $R$-matrix analysis. For
the first time, the $J^{\pi}$ values for ten states above the alpha threshold
in $^{22}$Mg have been experimentally determined in a single consistent
measurement. We have made three new $J^{\pi}$ assignments and confirmed seven
of the ten tentative assignments in the previous work. The
$^{18}$Ne($\alpha$,$p$)$^{21}$Na reaction rate has been recalculated, and the
astrophysical impact of our new rate has been investigated through one-zone
postprocessing x-ray burst calculations. We find that the
$^{18}$Ne($\alpha$,$p$)$^{21}$Na rate significantly affects the peak nuclear
energy generation rate and the onset temperature of this breakout reaction in
these phenomena.
[17]
oai:arXiv.org:1009.1206 [pdf] - 224084
Investigation of excited states in $^{18}$Ne via resonant elastic
scattering of $^{17}$F+p and its astrophysical implication in the stellar
reaction of $^{14}$O($\alpha$,$p$)$^{17}$F
Hu, J.;
He, J. J.;
Xu, S. W.;
Chen, Z. Q.;
Zhang, X. Y.;
Wang, J. S.;
Yu, X. Q.;
Li, L.;
Zhang, L. Y.;
Yang, Y. Y.;
Ma, P.;
Zhang, X. H.;
Hu, Z. G.;
Guo, Z. Y.;
Xu, X.;
Yuan, X. H.;
Lu, W.;
Yu, Y. H.;
Zang, Y. D.;
Tang, S. W.;
Ye, R. P.;
Chen, J. D.;
Jin, S. L.;
Du, C. M.;
Wang, S. T.;
Ma, J. B.;
Liu, L. X.;
Bai, Z.;
Lei, X. G.;
Sun, Z. Y.;
Zhang, Y. H.;
Zhou, X. H.;
Xu, H. S.;
Su, J.;
Li, E. T.;
Wang, H. W.;
Tian, W. D.;
Li, X. Q.
Submitted: 2010-09-07
Properties of proton resonances in $^{18}$Ne have been investigated
efficiently by utilizing a technique of proton resonant elastic scattering with
a $^{17}$F radioactive ion (RI) beam and a thick proton target. A
4.22~MeV/nucleon $^{17}$F RI beam was produced via a projectile-fragmentation
reaction, and subsequently separated by a Radioactive Ion Beam Line in Lanzhou
({\tt RIBLL}). Energy spectra of the recoiled protons were measured by two sets
of $\Delta$E-E silicon telescope at center-of-mass scattering angles of
$\theta_{c.m.}$$\approx$175${^\circ}$$\pm$5${^\circ}$,
$\theta_{c.m.}$$\approx$152${^\circ}$$\pm$8${^\circ}$, respectively. Several
proton resonances in $^{18}$Ne were observed, and their resonant parameters
have been determined by an $R$-matrix analysis of the differential cross
sections in combination with the previous results. The resonant parameters are
related to the reaction-rate calculation of the stellar
$^{14}$O($\alpha$,$p$)$^{17}$F reaction, which was thought to be the breakout
reaction from the hot CNO cycles into the $rp$-process in x-ray bursters. Here,
$J^\pi$=(3$^-$, 2$^-$) are tentatively assigned to the 6.15-MeV state which was
thought the key 1$^-$ state previously. In addition, a doublet structure at
7.05 MeV are tentatively identified, and its contribution to the resonant
reaction rate of $^{14}$O($\alpha$,$p$)$^{17}$F could be enhanced by at least
factors of about 4$\sim$6 in comparison with the previous estimation involving
only a singlet. The present calculated resonant rates are much larger than
those previous values, and it may imply that this breakout reaction could play
a crucial role under x-ray bursters conditions.
[18]
oai:arXiv.org:astro-ph/0405545 [pdf] - 65065
Estimation of Regularization Parameters in Multiple-Image Deblurring
Submitted: 2004-05-27
We consider the estimation of the regularization parameter for the
simultaneous deblurring of multiple noisy images via Tikhonov regularization.
We approach the problem in three ways. We first reduce the problem to a
single-image deblurring for which the regularization parameter can be estimated
through a classic generalized cross-validation (GCV) method. A modification of
this function is used for correcting the undersmoothing typical of the original
technique. With a second method, we minimize an average least-squares fit to
the images and define a new GCV function. In the last approach, we use the
classical $GCV$ on a single higher-dimensional image obtained by concatanating
all the images into a single vector. With a reliable estimator of the
regularization parameter, one can fully exploit the excellent computational
characteristics typical of direct deblurring methods, which, especially for
large images, makes them competitive with the more flexible but much slower
iterative algorithms. The performance of the techniques is analyzed through
numerical experiments. We find that under the independent homoscedastic and
Gaussian assumptions made on the noise, the three approaches provide almost
identical results with the first single image providing the practical advantage
that no new software is required and the same image can be used with other
deblurring algorithms.