Normalized to: Luu, V.
[1]
oai:arXiv.org:1510.06609 [pdf] - 1579736
Photon noise from chaotic and coherent millimeter-wave sources measured
with horn-coupled, aluminum lumped-element kinetic inductance detectors
Flanigan, Daniel;
McCarrick, Heather;
Jones, Glenn;
Johnson, Bradley R.;
Abitbol, Maximilian H.;
Ade, Peter;
Araujo, Derek;
Bradford, Kristi;
Cantor, Robin;
Che, George;
Day, Peter K.;
Doyle, Simon;
Kjellstrand, Carl Bjorn;
LeDuc, Henry G;
Limon, Michele;
Luu, Vy;
Mauskopf, Philip;
Miller, Amber;
Mroczkowski, Tony;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2015-10-22, last modified: 2017-05-24
We report photon-noise limited performance of horn-coupled, aluminum
lumped-element kinetic inductance detectors at millimeter wavelengths. The
detectors are illuminated by a millimeter-wave source that uses an active
multiplier chain to produce radiation between 140 and 160 GHz. We feed the
multiplier with either amplified broadband noise or a continuous-wave tone from
a microwave signal generator. We demonstrate that the detector response over a
40 dB range of source power is well-described by a simple model that considers
the number of quasiparticles. The detector noise-equivalent power (NEP) is
dominated by photon noise when the absorbed power is greater than approximately
1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \,
\mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher
source power levels we observe the relationships between noise and power
expected from the photon statistics of the source signal: $\mathrm{NEP} \propto
P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for
continuous-wave (coherent) illumination.
[2]
oai:arXiv.org:1510.04631 [pdf] - 1294164
NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray
Morphology and Spectroscopy of the Diffuse Emission
Mori, Kaya;
Hailey, Charles J.;
Krivonos, Roman;
Hong, Jaesub;
Ponti, Gabriele;
Bauer, Franz;
Perez, Kerstin;
Nynka, Melania;
Zhang, Shuo;
Tomsick, John A.;
Alexander, David M.;
Baganoff, Frederick K.;
Barret, Didier;
Barriere, Nicolas;
Boggs, Steven E.;
Canipe, Alicia M.;
Christensen, Finn E.;
Craig, William W.;
Forster, Karl;
Giommi, Paolo;
Grefenstette, Brian W.;
Grindlay, Jonathan E.;
Harrison, Fiona A.;
Hornstrup, Allan;
Kitaguchi, Takao;
Koglin, Jason E.;
Luu, Vy;
Madsen, Kristen K.;
Mao, Peter H.;
Miyasaka, Hiromasa;
Perri, Matteo;
Pivovaroff, Michael J.;
Puccetti, Simonetta;
Rana, Vikram;
Stern, Daniel;
Westergaard, Niels J.;
Zhang, William W.;
Zoglauer, Andreas
Submitted: 2015-10-15
We present the first sub-arcminute images of the Galactic Center above 10
keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR
J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources
and a previously unknown central component of hard X-ray emission (CHXE).
NuSTAR detects four non-thermal X-ray filaments, extending the detection of
their power-law spectra with $\Gamma\sim1.3$-$2.3$ up to ~50 keV. A
morphological and spectral study of the filaments suggests that their origin
may be heterogeneous, where previous studies suggested a common origin in young
pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission
spatially correlated with the 6.4 keV Fe K$\alpha$ fluorescence line emission
associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band
X-ray spectral analysis with a Monte-Carlo based X-ray reflection model
self-consistently determined their intrinsic column density ($\sim10^{23}$
cm$^{-2}$), primary X-ray spectra (power-laws with $\Gamma\sim2$) and set a
lower limit of the X-ray luminosity of Sgr A* flare illuminating the Sgr A
clouds to $L_X \stackrel{>}{\sim} 10^{38}$ erg s$^{-1}$. Above ~20 keV, hard
X-ray emission in the central 10 pc region around Sgr A* consists of the
candidate PWN G359.95-0.04 and the CHXE, possibly resulting from an unresolved
population of massive CVs with white dwarf masses $M_{\rm WD} \sim 0.9
M_{\odot}$. Spectral energy distribution analysis suggests that G359.95-0.04 is
likely the hard X-ray counterpart of the ultra-high gamma-ray source HESS
J1745-290, strongly favoring a leptonic origin of the GC TeV emission.
[3]
oai:arXiv.org:1407.7749 [pdf] - 971383
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic
Inductance Detectors for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P.;
Araujo, D.;
Bradford, K.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Luu, V.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2014-07-29, last modified: 2015-03-26
We discuss the design, fabrication, and testing of prototype horn-coupled,
lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic
microwave background (CMB) studies. The LEKIDs are made from a thin aluminum
film deposited on a silicon wafer and patterned using standard
photolithographic techniques at STAR Cryoelectronics, a commercial device
foundry. We fabricated twenty-element arrays, optimized for a spectral band
centered on 150 GHz, to test the sensitivity and yield of the devices as well
as the multiplexing scheme. We characterized the detectors in two
configurations. First, the detectors were tested in a dark environment with the
horn apertures covered, and second, the horn apertures were pointed towards a
beam-filling cryogenic blackbody load. These tests show that the multiplexing
scheme is robust and scalable, the yield across multiple LEKID arrays is 91%,
and the noise-equivalent temperatures (NET) for a 4 K optical load are in the
range 26$\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}$.