sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Lutz, L.

Normalized to: Lutz, L.

9 article(s) in total. 72 co-authors, from 1 to 9 common article(s). Median position in authors list is 16,0.

[1]  oai:arXiv.org:1003.4745  [pdf] - 1700287
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Comments: This submission has been withdrawn by arXiv administrators because it is a duplicate of arXiv:physics/0507174
Submitted: 2010-03-24, last modified: 2018-06-15
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
[2]  oai:arXiv.org:1103.1321  [pdf] - 371120
Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays
Comments: 24 pages, 19 figures
Submitted: 2011-03-07, last modified: 2011-05-18
A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.
[3]  oai:arXiv.org:1102.2575  [pdf] - 391297
Cosmic-Ray Proton and Helium Spectra from the First CREAM Flight
Comments: 20 pages, 4 figures
Submitted: 2011-02-13
Cosmic-ray proton and helium spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data were collected at an average altitude of ~38.5 km with an average atmospheric overburden of ~3.9 g cm$^{-2}$. Individual elements are clearly separated with a charge resolution of ~0.15 e (in charge units) and ~0.2 e for protons and helium nuclei, respectively. The measured spectra at the top of the atmosphere are represented by power laws with a spectral index of -2.66 $\pm$ 0.02 for protons from 2.5 TeV to 250 TeV and -2.58 $\pm$ 0.02 for helium nuclei from 630 GeV/nucleon to 63 TeV/nucleon. They are harder than previous measurements at a few tens of GeV/nucleon. The helium flux is higher than that expected from the extrapolation of the power law fitted to the lower-energy data. The relative abundance of protons to helium nuclei is 9.1 $\pm$ 0.5 for the range from 2.5 TeV/nucleon to 63 TeV/nucleon. This ratio is considerably smaller than the previous measurements at a few tens of GeV/nucleon.
[4]  oai:arXiv.org:1004.1123  [pdf] - 144585
Discrepant hardening observed in cosmic-ray elemental spectra
Comments: 21 pages, 5 figures, published in ApJL (corresponding author: seo@umd.edu)
Submitted: 2010-04-07
The balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment launched five times from Antarctica has achieved a cumulative flight duration of about 156 days above 99.5% of the atmosphere. The instrument is configured with complementary and redundant particle detectors designed to extend direct measurements of cosmic-ray composition to the highest energies practical with balloon flights. All elements from protons to iron nuclei are separated with excellent charge resolution. Here we report results from the first two flights of ~70 days, which indicate hardening of the elemental spectra above ~200 GeV/nucleon and a spectral difference between the two most abundant species, protons and helium nuclei. These results challenge the view that cosmic-ray spectra are simple power laws below the so-called knee at ~1015 eV. This discrepant hardening may result from a relatively nearby source, or it could represent spectral concavity caused by interactions of cosmic rays with the accelerating shock. Other possible explanations should also be investigated.
[5]  oai:arXiv.org:1003.4983  [pdf] - 1025943
Elemental Spectra from the CREAM-I Flight
Comments: Proc. 30th Int. Cosmic Ray Conf., Merida, 2, 63-66, 2007
Submitted: 2010-03-25, last modified: 2010-03-30
The Cosmic Ray Energetics And Mass (CREAM) is a balloon-borne experiment designed to measure the composition and energy spectra of cosmic rays of charge Z = 1 to 26 up to an energy of ~ 10^15 eV. CREAM had two successful flights on long-duration balloons (LDB) launched from Mc- Murdo Station, Antarctica, in December 2004 and December 2005. CREAM-I achieves a substantial measurement redundancy by employing multiple detector systems, namely a Timing Charge Detector and a Silicon Charge Detector (SCD) for particle identification, and a Transition Radiation Detector and a sampling tungsten/scintillating-fiber ionization calorimeter (CAL) for energy measurement. In this paper, preliminary energy spectra of various elements measured with CAL/SCD during the first 42-day flight are presented.
[6]  oai:arXiv.org:1003.5753  [pdf] - 138200
Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter
Comments: 4 pages, 3 figures, presented at ICRC 2008
Submitted: 2010-03-30
The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicraynuclei. Each detector was calibrated with particle beams in a limited range of energies. In order to assess the absolute energy scale of the instrument and to investigate the systematic effects of each technique, a cross-calibration was performed by comparing the two independent energy estimates on selected samples of oxygen and carbon nuclei.
[7]  oai:arXiv.org:1003.4743  [pdf] - 137064
Performance of the CREAM calorimeter in accelerator beam test
Comments: 29th International Cosmic Ray Conference Pune (2005) 8, 371-374
Submitted: 2010-03-24
The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20 layers of scintillating fiber ribbons, and is preceded by a pair of graphite interaction targets providing about 0.42 proton interaction lengths (\lambda int). The calorimeter was placed in one of CERN's SPS accelerator beams for calibration and testing. Beams of 150 GeV electrons were used for calibration, and a variety of electron, proton, and nuclear fragment beams were used to test the simulation model of the detector. In this paper we discuss the performance of the calorimeter in the electron beam and compare electron beam data with simulation results.
[8]  oai:arXiv.org:1003.4737  [pdf] - 137061
Calibration of the CREAM-I calorimeter
Comments: Proc. 30th Int. Cosmic Ray Conf., Merida, 2, 421-424, 2007
Submitted: 2010-03-24
The Cosmic Ray Energetics And Mass (CREAM) calorimeter is designed to measure the spectra of cosmic-ray particles over the energy range from ~10^11 eV to ~10^15 eV. Its first flight as part of the CREAM-I balloon-borne payload in Antarctica during the 2004/05 season resulted in a recordbreaking 42 days of exposure. Calorimeter calibration using various beam test data will be discussed in an attempt to assess the uncertainties of the energy measurements.
[9]  oai:arXiv.org:0808.1718  [pdf] - 15339
Measurements of cosmic-ray secondary nuclei at high energies with the first flight of the CREAM balloon-borne experiment
Comments: Accepted for publication in Astroparticle Physics
Submitted: 2008-08-12
We present new measurements of heavy cosmic-ray nuclei at high energies per- formed during the first flight of the balloon-borne cosmic-ray experiment CREAM (Cosmic-Ray Energetics And Mass). This instrument uses multiple charge detectors and a transition radiation detector to provide the first high accuracy measurements of the relative abundances of elements from boron to oxygen up to energies around 1 TeV/n. The data agree with previous measurements at lower energies and show a relatively steep decline (~E$^-0.6$ to E$^-0.5$) at high energies. They further show the source abundance of nitrogen relative to oxygen is ~10% in the TeV/n region.