Normalized to: Luke, P.
[1]
oai:arXiv.org:1106.0323 [pdf] - 1077028
Detection and Imaging of the Crab Nebula with the Nuclear Compton
Telescope
Bandstra, M. S.;
Bellm, E. C.;
Boggs, S. E.;
Perez-Becker, D.;
Zoglauer, A.;
Chang, H. -K.;
Chiu, J. -L.;
Liang, J. -S.;
Chang, Y. -H.;
Liu, Z. -K.;
Hung, W. -C.;
Huang, M. -H. A.;
Chiang, S. J.;
Run, R. -S.;
Lin, C. -H.;
Amman, M.;
Luke, P. N.;
Jean, P.;
von Ballmoos, P.;
Wunderer, C. B.
Submitted: 2011-06-01
The Nuclear Compton Telescope (NCT) is a balloon-borne Compton telescope
designed for the study of astrophysical sources in the soft gamma-ray regime
(200 keV--20 MeV). NCT's ten high-purity germanium crossed-strip detectors
measure the deposited energies and three-dimensional positions of gamma-ray
interactions in the sensitive volume, and this information is used to restrict
the initial photon to a circle on the sky using the Compton scatter technique.
Thus NCT is able to perform spectroscopy, imaging, and polarization analysis on
soft gamma-ray sources. NCT is one of the next generation of Compton telescopes
--- so-called compact Compton telescopes (CCTs) --- which can achieve effective
areas comparable to COMPTEL's with an instrument that is a fraction of the
size. The Crab Nebula was the primary target for the second flight of the NCT
instrument, which occurred on 17--18 May 2009 in Fort Sumner, New Mexico.
Analysis of 29.3 ks of data from the flight reveals an image of the Crab at a
significance of 4-sigma. This is the first reported detection of an
astrophysical source by a CCT.
[2]
oai:arXiv.org:astro-ph/0609069 [pdf] - 260784
Cryogenic tests of volume-phase holographic gratings: results at 100 K
Submitted: 2006-09-04
We present results from cryogenic tests of Volume-Phase Holographic(VPH)
gratings at 100 K. The aims of these tests are to see whether the diffraction
efficiency as a function of wavelength is significantly different at a low
temperature from that at room temperature and to see how the performance of a
VPH grating is affected by a number of thermal cycles. We have completed 10
cycles between room temperature and 100 $K$, and find no clear evidence that
the diffraction efficiency changes with temperature or with successive thermal
cycle.
[3]
oai:arXiv.org:astro-ph/0311517 [pdf] - 61097
Cryogenic Tests of Volume-Phase Holographic Gratings: I. Results at 200
K
Submitted: 2003-11-22
We present results from cryogenic tests of a Volume-Phase Holographic (VPH)
grating at 200 K measured at near-infrared wavelengths. The aims of these tests
were to see whether the diffraction efficiency and angular dispersion of a VPH
grating are significantly different at a low temperature from those at a room
temperature, and to see how many cooling and heating cycles the grating can
withstand. We have completed 5 cycles between room temperature and 200 K, and
find that the performance is nearly independent of temperature, at least over
the temperature range which we are investigating. In future, we will not only
try more cycles between these temperatures but also perform measurements at a
much lower temperature (e.g., 80 K).