sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Luiten, A. N.

Normalized to: Luiten, A.

5 article(s) in total. 24 co-authors, from 1 to 3 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1202.0819  [pdf] - 1116387
Laser frequency comb techniques for precise astronomical spectroscopy
Comments: 11 pages, 7 figures. Accepted for publication in MNRAS
Submitted: 2012-02-03
Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomical spectrographs, but here we show that they can also be used to measure IPS variations in astronomical CCDs in situ. We successfully tested a laser frequency comb system on the Ultra-High Resolution Facility spectrograph at the Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded in a single CCD exposure, we find that the average IPS deviates by <8 per cent if it is assumed to vary symmetrically about the pixel centre. We also demonstrate that series of comb exposures with absolutely known offsets between them can yield tighter constraints on symmetric IPS variations from ~100 pixels. We discuss measurement of asymmetric IPS variations and absolute wavelength calibration of astronomical spectrographs and CCDs using frequency combs.
[2]  oai:arXiv.org:1004.0115  [pdf] - 288991
Colloquium: Comparison of Astrophysical and Terrestrial Frequency Standards
Comments: 9 pages, 2 figures; presented at the International Frequency Control Symposium, Newport Beach, Calif., June, 2010; presented at Pulsar Conference 2010, October 12th, Sardinia; accepted 13th September 2010 for publication in Reviews of Modern Physics
Submitted: 2010-04-01, last modified: 2010-11-15
We have re-analyzed the stability of pulse arrival times from pulsars and white dwarfs using several analysis tools for measuring the noise characteristics of sampled time and frequency data. We show that the best terrestrial artificial clocks substantially exceed the performance of astronomical sources as time-keepers in terms of accuracy (as defined by cesium primary frequency standards) and stability. This superiority in stability can be directly demonstrated over time periods up to two years, where there is high quality data for both. Beyond 2 years there is a deficiency of data for clock/clock comparisons and both terrestrial and astronomical clocks show equal performance being equally limited by the quality of the reference timescales used to make the comparisons. Nonetheless, we show that detailed accuracy evaluations of modern terrestrial clocks imply that these new clocks are likely to have a stability better than any astronomical source up to comparison times of at least hundreds of years. This article is intended to provide a correct appreciation of the relative merits of natural and artificial clocks. The use of natural clocks as tests of physics under the most extreme conditions is entirely appropriate; however, the contention that these natural clocks, particularly white dwarfs, can compete as timekeepers against devices constructed by mankind is shown to be doubtful.
[3]  oai:arXiv.org:gr-qc/0401017  [pdf] - 111424
Whispering Gallery Resonators and Tests of Lorentz Invariance
Comments: 21 pages, 6 figures, accepted for General Relativity and Gravitation (January, 2004). New version with slight changes following the referee's suggestions
Submitted: 2004-01-06, last modified: 2004-02-10
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Robertson, Mansouri and Sexl and in the standard model extension (SME) of Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl test theory to $1/2 - \beta_{MS} + \delta_{MS} = (1.2 \pm 2.2) \times 10^{-9}$ and $\beta_{MS} - \alpha_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of the same order as the best results from other experiments for the former and represents a 70 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
[4]  oai:arXiv.org:astro-ph/0310112  [pdf] - 1591979
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Comments: 13 pages, 5 figures
Submitted: 2003-10-04
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison between a cryogenic sapphire oscillator and a hydrogen maser. It tests Local Lorentz Invariance. In both cases, we report recent results which improve significantly over previous experiments.
[5]  oai:arXiv.org:gr-qc/0306047  [pdf] - 111265
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Comments: 6 pages, 2 figures, to appear in Proc. of the 2003 joint IEEE FCS/EFTF meeting, to appear in Proc. of the 2003 Rencontres de Moriond
Submitted: 2003-06-11
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $\delta - \beta + 1/2 \leq 3.4 \times 10^{-9}$ and $\beta - \alpha - 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.