Laser frequency comb techniques for precise astronomical spectroscopy
Submitted: 2012-02-03
Precise astronomical spectroscopic analyses routinely assume that individual
pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons.
Intra-pixel sensitivity (IPS) variations may already cause small systematic
errors in, for example, studies of extra-solar planets via stellar radial
velocities and cosmological variability in fundamental constants via quasar
spectroscopy, but future experiments requiring velocity precisions approaching
~1 cm/s will be more strongly affected. Laser frequency combs have been shown
to provide highly precise wavelength calibration for astronomical
spectrographs, but here we show that they can also be used to measure IPS
variations in astronomical CCDs in situ. We successfully tested a laser
frequency comb system on the Ultra-High Resolution Facility spectrograph at the
Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded
in a single CCD exposure, we find that the average IPS deviates by <8 per cent
if it is assumed to vary symmetrically about the pixel centre. We also
demonstrate that series of comb exposures with absolutely known offsets between
them can yield tighter constraints on symmetric IPS variations from ~100
pixels. We discuss measurement of asymmetric IPS variations and absolute
wavelength calibration of astronomical spectrographs and CCDs using frequency
combs.
[2]
oai:arXiv.org:1004.0115 [pdf] - 288991
Colloquium: Comparison of Astrophysical and Terrestrial Frequency
Standards
Submitted: 2010-04-01, last modified: 2010-11-15
We have re-analyzed the stability of pulse arrival times from pulsars and
white dwarfs using several analysis tools for measuring the noise
characteristics of sampled time and frequency data. We show that the best
terrestrial artificial clocks substantially exceed the performance of
astronomical sources as time-keepers in terms of accuracy (as defined by cesium
primary frequency standards) and stability. This superiority in stability can
be directly demonstrated over time periods up to two years, where there is high
quality data for both. Beyond 2 years there is a deficiency of data for
clock/clock comparisons and both terrestrial and astronomical clocks show equal
performance being equally limited by the quality of the reference timescales
used to make the comparisons. Nonetheless, we show that detailed accuracy
evaluations of modern terrestrial clocks imply that these new clocks are likely
to have a stability better than any astronomical source up to comparison times
of at least hundreds of years. This article is intended to provide a correct
appreciation of the relative merits of natural and artificial clocks. The use
of natural clocks as tests of physics under the most extreme conditions is
entirely appropriate; however, the contention that these natural clocks,
particularly white dwarfs, can compete as timekeepers against devices
constructed by mankind is shown to be doubtful.
[3]
oai:arXiv.org:gr-qc/0401017 [pdf] - 111424
Whispering Gallery Resonators and Tests of Lorentz Invariance
Submitted: 2004-01-06, last modified: 2004-02-10
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are
compared to set new constraints on a possible violation of Lorentz invariance.
We give a detailed description of microwave resonators operating in Whispering
Gallery modes and then apply it to derive explicit models for Lorentz violating
effects in our experiment. Models are calculated in the theoretical framework
of Robertson, Mansouri and Sexl and in the standard model extension (SME) of
Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl
test theory to $1/2 - \beta_{MS} + \delta_{MS} = (1.2 \pm 2.2) \times 10^{-9}$
and $\beta_{MS} - \alpha_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of
the same order as the best results from other experiments for the former and
represents a 70 fold improvement for the latter. These results correspond to an
improvement of our previously published limits [Wolf P. et al., Phys. Rev.
Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
[4]
oai:arXiv.org:astro-ph/0310112 [pdf] - 1591979
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Bize, S.;
Wolf, P.;
Abgrall, M.;
Cacciapuoti, L.;
Clairon, A.;
Gruenert, J.;
Laurent, Ph.;
Lemonde, P.;
Maksimovic, I.;
Mandache, C.;
Marion, H.;
Santos, F. Pereira Dos;
Rosenbusch, P.;
Santarelli, G.;
Sortais, Y.;
Vian, C.;
Zhang, S.;
Salomon, C.;
Luiten, A. N.;
Tobar, M. E.
Submitted: 2003-10-04
We describe two experimental tests of the Equivalence Principle that are
based on frequency measurements between precision oscillators and/or highly
accurate atomic frequency standards. Based on comparisons between the hyperfine
frequencies of 87Rb and 133Cs in atomic fountains, the first experiment
constrains the stability of fundamental constants. The second experiment is
based on a comparison between a cryogenic sapphire oscillator and a hydrogen
maser. It tests Local Lorentz Invariance. In both cases, we report recent
results which improve significantly over previous experiments.
[5]
oai:arXiv.org:gr-qc/0306047 [pdf] - 111265
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Submitted: 2003-06-11
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are
compared to set new constraints on a possible violation of Lorentz invariance.
We determine the variation of the oscillator frequency as a function of its
orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike
test) with respect to a preferred frame candidate. We constrain the
corresponding parameters of the Mansouri and Sexl test theory to $\delta -
\beta + 1/2 \leq 3.4 \times 10^{-9}$ and $\beta - \alpha - 1 \leq 4.1 \times
10^{-7}$ which is of the same order as the best previous result for the former
and represents a 50 fold improvement for the latter. These results correspond
to an improvement of our previously published limits [Wolf P. et al., Phys.
Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the
changes of the experiment, and show the new data that lead to that improvement.