Normalized to: Lowe, S.
[1]
oai:arXiv.org:1303.5062 [pdf] - 832330
Planck 2013 results. I. Overview of products and scientific results
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Alves, M. I. R.;
Armitage-Caplan, C.;
Arnaud, M.;
Ashdown, M.;
Atrio-Barandela, F.;
Aumont, J.;
Aussel, H.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Barrena, R.;
Bartelmann, M.;
Bartlett, J. G.;
Bartolo, N.;
Basak, S.;
Battaner, E.;
Battye, R.;
Benabed, K.;
Benoît, A.;
Benoit-Lévy, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bertincourt, B.;
Bethermin, M.;
Bielewicz, P.;
Bikmaev, I.;
Blanchard, A.;
Bobin, J.;
Bock, J. J.;
Böhringer, H.;
Bonaldi, A.;
Bonavera, L.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Boulanger, F.;
Bourdin, H.;
Bowyer, J. W.;
Bridges, M.;
Brown, M. L.;
Bucher, M.;
Burenin, R.;
Burigana, C.;
Butler, R. C.;
Calabrese, E.;
Cappellini, B.;
Cardoso, J. -F.;
Carr, R.;
Carvalho, P.;
Casale, M.;
Castex, G.;
Catalano, A.;
Challinor, A.;
Chamballu, A.;
Chary, R. -R.;
Chen, X.;
Chiang, H. C.;
Chiang, L. -Y;
Chon, G.;
Christensen, P. R.;
Churazov, E.;
Church, S.;
Clemens, M.;
Clements, D. L.;
Colombi, S.;
Colombo, L. P. L.;
Combet, C.;
Comis, B.;
Couchot, F.;
Coulais, A.;
Crill, B. P.;
Cruz, M.;
Curto, A.;
Cuttaia, F.;
Da Silva, A.;
Dahle, H.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
de Bernardis, P.;
de Rosa, A.;
de Zotti, G.;
Déchelette, T.;
Delabrouille, J.;
Delouis, J. -M.;
Démoclès, J.;
Désert, F. -X.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Dolag, K.;
Dole, H.;
Donzelli, S.;
Doré, O.;
Douspis, M.;
Ducout, A.;
Dunkley, J.;
Dupac, X.;
Efstathiou, G.;
Elsner, F.;
Enßlin, T. A.;
Eriksen, H. K.;
Fabre, O.;
Falgarone, E.;
Falvella, M. C.;
Fantaye, Y.;
Fergusson, J.;
Filliard, C.;
Finelli, F.;
Flores-Cacho, I.;
Foley, S.;
Forni, O.;
Fosalba, P.;
Frailis, M.;
Fraisse, A. A.;
Franceschi, E.;
Freschi, M.;
Fromenteau, S.;
Frommert, M.;
Gaier, T. C.;
Galeotta, S.;
Gallegos, J.;
Galli, S.;
Gandolfo, B.;
Ganga, K.;
Gauthier, C.;
Génova-Santos, R. T.;
Ghosh, T.;
Giard, M.;
Giardino, G.;
Gilfanov, M.;
Girard, D.;
Giraud-Héraud, Y.;
Gjerløw, E.;
González-Nuevo, J.;
Górski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Gudmundsson, J. E.;
Haissinski, J.;
Hamann, J.;
Hansen, F. K.;
Hansen, M.;
Hanson, D.;
Harrison, D. L.;
Heavens, A.;
Helou, G.;
Hempel, A.;
Henrot-Versillé, S.;
Hernández-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Ho, S.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hou, Z.;
Hovest, W.;
Huey, G.;
Huffenberger, K. M.;
Hurier, G.;
Ilić, S.;
Jaffe, A. H.;
Jaffe, T. R.;
Jasche, J.;
Jewell, J.;
Jones, W. C.;
Juvela, M.;
Kalberla, P.;
Kangaslahti, P.;
Keihänen, E.;
Kerp, J.;
Keskitalo, R.;
Khamitov, I.;
Kiiveri, K.;
Kim, J.;
Kisner, T. S.;
Kneissl, R.;
Knoche, J.;
Knox, L.;
Kunz, M.;
Kurki-Suonio, H.;
Lacasa, F.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Langer, M.;
Lasenby, A.;
Lattanzi, M.;
Laureijs, R. J.;
Lavabre, A.;
Lawrence, C. R.;
Jeune, M. Le;
Leach, S.;
Leahy, J. P.;
Leonardi, R.;
León-Tavares, J.;
Leroy, C.;
Lesgourgues, J.;
Lewis, A.;
Li, C.;
Liddle, A.;
Liguori, M.;
Lilje, P. B.;
Linden-Vørnle, M.;
Lindholm, V.;
López-Caniego, M.;
Lowe, S.;
Lubin, P. M.;
Macías-Pérez, J. F.;
MacTavish, C. J.;
Maffei, B.;
Maggio, G.;
Maino, D.;
Mandolesi, N.;
Mangilli, A.;
Marcos-Caballero, A.;
Marinucci, D.;
Maris, M.;
Marleau, F.;
Marshall, D. J.;
Martin, P. G.;
Martínez-González, E.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Matsumura, T.;
Matthai, F.;
Maurin, L.;
Mazzotta, P.;
McDonald, A.;
McEwen, J. D.;
McGehee, P.;
Mei, S.;
Meinhold, P. R.;
Melchiorri, A.;
Melin, J. -B.;
Mendes, L.;
Menegoni, E.;
Mennella, A.;
Migliaccio, M.;
Mikkelsen, K.;
Millea, M.;
Miniscalco, R.;
Mitra, S.;
Miville-Deschênes, M. -A.;
Molinari, D.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Morisset, N.;
Mortlock, D.;
Moss, A.;
Munshi, D.;
Murphy, J. A.;
Naselsky, P.;
Nati, F.;
Natoli, P.;
Negrello, M.;
Nesvadba, N. P. H.;
Netterfield, C. B.;
Nørgaard-Nielsen, H. U.;
North, C.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
O'Dwyer, I. J.;
Orieux, F.;
Osborne, S.;
O'Sullivan, C.;
Oxborrow, C. A.;
Paci, F.;
Pagano, L.;
Pajot, F.;
Paladini, R.;
Pandolfi, S.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Patanchon, G.;
Paykari, P.;
Pearson, D.;
Pearson, T. J.;
Peel, M.;
Peiris, H. V.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Pettorino, V.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Pietrobon, D.;
Plaszczynski, S.;
Platania, P.;
Pogosyan, D.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Pratt, G. W.;
Prézeau, G.;
Prunet, S.;
Puget, J. -L.;
Pullen, A. R.;
Rachen, J. P.;
Racine, B.;
Rahlin, A.;
Räth, C.;
Reach, W. T.;
Rebolo, R.;
Reinecke, M.;
Remazeilles, M.;
Renault, C.;
Renzi, A.;
Riazuelo, A.;
Ricciardi, S.;
Riller, T.;
Ringeval, C.;
Ristorcelli, I.;
Robbers, G.;
Rocha, G.;
Roman, M.;
Rosset, C.;
Rossetti, M.;
Roudier, G.;
Rowan-Robinson, M.;
Rubiño-Martín, J. A.;
Ruiz-Granados, B.;
Rusholme, B.;
Salerno, E.;
Sandri, M.;
Sanselme, L.;
Santos, D.;
Savelainen, M.;
Savini, G.;
Schaefer, B. M.;
Schiavon, F.;
Scott, D.;
Seiffert, M. D.;
Serra, P.;
Shellard, E. P. S.;
Smith, K.;
Smoot, G. F.;
Souradeep, T.;
Spencer, L. D.;
Starck, J. -L.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sunyaev, R.;
Sureau, F.;
Sutter, P.;
Sutton, D.;
Suur-Uski, A. -S.;
Sygnet, J. -F.;
Tauber, J. A.;
Tavagnacco, D.;
Taylor, D.;
Terenzi, L.;
Texier, D.;
Toffolatti, L.;
Tomasi, M.;
Torre, J. -P.;
Tristram, M.;
Tucci, M.;
Tuovinen, J.;
Türler, M.;
Tuttlebee, M.;
Umana, G.;
Valenziano, L.;
Valiviita, J.;
Van Tent, B.;
Varis, J.;
Vibert, L.;
Viel, M.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Watson, C.;
Watson, R.;
Wehus, I. K.;
Welikala, N.;
Weller, J.;
White, M.;
White, S. D. M.;
Wilkinson, A.;
Winkel, B.;
Xia, J. -Q.;
Yvon, D.;
Zacchei, A.;
Zibin, J. P.;
Zonca, A.
Submitted: 2013-03-20, last modified: 2014-06-05
The ESA's Planck satellite, dedicated to studying the early Universe and its
subsequent evolution, was launched 14 May 2009 and has been scanning the
microwave and submillimetre sky continuously since 12 August 2009. This paper
gives an overview of the mission and its performance, the processing, analysis,
and characteristics of the data, the scientific results, and the science data
products and papers in the release. The science products include maps of the
CMB and diffuse extragalactic foregrounds, a catalogue of compact Galactic and
extragalactic sources, and a list of sources detected through the SZ effect.
The likelihood code used to assess cosmological models against the Planck data
and a lensing likelihood are described. Scientific results include robust
support for the standard six-parameter LCDM model of cosmology and improved
measurements of its parameters, including a highly significant deviation from
scale invariance of the primordial power spectrum. The Planck values for these
parameters and others derived from them are significantly different from those
previously determined. Several large-scale anomalies in the temperature
distribution of the CMB, first detected by WMAP, are confirmed with higher
confidence. Planck sets new limits on the number and mass of neutrinos, and has
measured gravitational lensing of CMB anisotropies at greater than 25 sigma.
Planck finds no evidence for non-Gaussianity in the CMB. Planck's results agree
well with results from the measurements of baryon acoustic oscillations. Planck
finds a lower Hubble constant than found in some more local measures. Some
tension is also present between the amplitude of matter fluctuations derived
from CMB data and that derived from SZ data. The Planck and WMAP power spectra
are offset from each other by an average level of about 2% around the first
acoustic peak.
[2]
oai:arXiv.org:1308.6647 [pdf] - 1178894
Representing the "butterfly" projection in FITS - projection code XPH
Submitted: 2013-08-30
The "butterfly" projection is constructed as the polar layout of the HEALPix
projection with (H,K) = (4,3). This short article formalises its representation
in FITS.
[3]
oai:arXiv.org:1307.2029 [pdf] - 689677
In-flight calibration and verification of the Planck-LFI instrument
Gregorio, Anna;
Cuttaia, Francesco;
Mennella, Aniello;
Bersanelli, Marco;
Maris, Michele;
Meinhold, Peter;
Sandri, Maura;
Terenzi, Luca;
Tomasi, Maurizio;
Villa, Fabrizio;
Frailis, Marco;
Morgante, Gianluca;
Pearson, Dave;
Zacchei, Andrea;
Battaglia, Paola;
Butler, Reginald Christophe;
Davis, Richard;
Franceschet, Cristian;
Franceschi, Enrico;
Galeotta, Samuele;
Leonardi, Rodrigo;
Lowe, Steve;
Mandolesi, Nazzareno;
Melot, Frederick;
Mendes, Luis;
Stassi, Patrick;
Stringhetti, Luca;
Tavagnacco, Daniele;
Zonca, Andrea;
Wilkinson, Althea;
Wilson, Philip;
Charra, Maryse;
Maciaszek, Thierry;
Foley, Steve;
Watson, Christopher J.;
Casale, Mauro;
Laureijs, René;
Tauber, Jan;
Texier, Damien;
Baker, Michelle;
Cuevas, Leticia Perez;
Krassenburg, Mike;
Rihet, Patrick
Submitted: 2013-07-08
In this paper we discuss the Planck-LFI in-flight calibration campaign. After
a brief overview of the ground test campaigns, we describe in detail the
calibration and performance verification (CPV) phase, carried out in space
during and just after the cool-down of LFI. We discuss in detail the
functionality verification, the tuning of the front-end and warm electronics,
the preliminary performance assessment and the thermal susceptibility tests.
The logic, sequence, goals and results of the in-flight tests are discussed.
All the calibration activities were successfully carried out and the instrument
response was comparable to the one observed on ground. For some channels the
in-flight tuning activity allowed us to improve significantly the noise
performance.
[4]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[5]
oai:arXiv.org:1108.2307 [pdf] - 1083342
Statistical Studies of Giant Pulse Emission from the Crab Pulsar
Submitted: 2011-08-10
We have observed the Crab pulsar with the Deep Space Network (DSN) Goldstone
70 m antenna at 1664 MHz during three observing epochs for a total of 4 hours.
Our data analysis has detected more than 2500 giant pulses, with flux densities
ranging from 0.1 kJy to 150 kJy and pulse widths from 125 ns (limited by our
bandwidth) to as long as 100 microseconds, with median power amplitudes and
widths of 1 kJy and 2 microseconds respectively. The most energetic pulses in
our sample have energy fluxes of approximately 100 kJy-microsecond. We have
used this large sample to investigate a number of giant-pulse emission
properties in the Crab pulsar, including correlations among pulse flux density,
width, energy flux, phase and time of arrival. We present a consistent
accounting of the probability distributions and threshold cuts in order to
reduce pulse-width biases. The excellent sensitivity obtained has allowed us to
probe further into the population of giant pulses. We find that a significant
portion, no less than 50%, of the overall pulsed energy flux at our observing
frequency is emitted in the form of giant pulses.
[6]
oai:arXiv.org:1106.3766 [pdf] - 1077399
Sunyaev Zel'dovich observations of a statistically complete sample of
galaxy clusters with OCRA-p
Lancaster, Katy;
Birkinshaw, Mark;
Gawronski, Marcin P.;
Battye, Richard;
Browne, Ian;
Davis, Richard;
Giles, Paul;
Feiler, Roman;
Kus, Andrzej;
Lew, Bartosz;
Lowe, Stuart;
Maughan, Ben;
Mohammad, Abdulaziz;
Pazderska, Bogna;
Pazderski, Eugeniusz;
Peel, Mike;
Roukema, Boud;
Wilkinson, Peter
Submitted: 2011-06-19
We present 30 GHz Sunyaev Zel'dovich observations of a statistically complete
sample of galaxy clusters with OCRA-p. The clusters are the 18 most X-ray
luminous clusters at z > 0.2 in the ROSAT Brightest Cluster Sample. We correct
for contaminant radio sources via supplementary observations with the Green
Bank Telescope, also at 30 GHz, and remove a cluster that is contaminated by an
unresolved X-ray source. All 17 remaining clusters have central SZ effects with
Comptonisation parameter y_0 exceeding 1.9x10^-4, and 13 are detected at
significance > 3 sigma. We use our data to examine scalings between y_0 and
X-ray temperature, X-ray luminosity, and the X-ray mass proxy Y_X, and find
good agreement with predictions from self-similar models of cluster formation,
with an intrinsic scatter in y_0 of about 25%. We also comment on the success
of the observations in the face of the contaminant source population, and the
implications for upcoming cm-wave surveys.
[7]
oai:arXiv.org:1101.2022 [pdf] - 1521890
Planck Early Results: The Planck mission
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Baccigalupi, C.;
Baker, M.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Bennett, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Bock, J. J.;
Bonaldi, A.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Bradshaw, T.;
Bremer, M.;
Bucher, M.;
Burigana, C.;
Butler, R. C.;
Cabella, P.;
Cantalupo, C. M.;
Cappellini, B.;
Cardoso, J. -F.;
Carr, R.;
Casale, M.;
Catalano, A.;
Cayón, L.;
Challinor, A.;
Chamballu, A.;
Charra, J.;
Chary, R. -R.;
Chiang, L. -Y;
Chiang, C.;
Christensen, P. R.;
Clements, D. L.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Crill, B. P.;
Crone, G.;
Crook, M.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
de Bernardis, P.;
de Bruin, J.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Delabrouille, J.;
Delouis, J. -M.;
Dèsert, F. -X.;
Dick, J.;
Dickinson, C.;
Dolag, K.;
Dole, H.;
Donzelli, S.;
Dorè, O.;
Dörl, U.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enfllin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Foley, S.;
Forni, O.;
Fosalba, P.;
Frailis, M.;
Franceschi, E.;
Freschi, M.;
Gaier, T. C.;
Galeotta, S.;
Gallegos, J.;
Gandolfo, B.;
Ganga, K.;
Giard, M.;
Giardino, G.;
Gienger, G.;
Giraud-Hèraud, Y.;
González, J.;
González-Nuevo, J.;
Górski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Guyot, G.;
Haissinski, J.;
Hansen, F. K.;
Harrison, D.;
Helou, G.;
Henrot-Versillè, S.;
Hernández-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hovest, W.;
Hoyland, R. J.;
Huffenberger, K. M.;
Jaffe, A. H.;
Jagemann, T.;
Jones, W. C.;
Juillet, J. J.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T. S.;
Kneissl, R.;
Knox, L.;
Krassenburg, M.;
Kurki-Suonio, H.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Lange, A. E.;
Lasenby, A.;
Laureijs, R. J.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Leonardi, R.;
Leroy, C.;
Lilje, P. B.;
Linden-Vørnle, M.;
López-Caniego, M.;
Lowe, S.;
Lubin, P. M.;
Macìas-Pèrez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maffei, B.;
Maino, D.;
Mandolesi, N.;
Mann, R.;
Maris, M.;
Martìnez-González, E.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Mazzotta, P.;
McDonald, A.;
McGehee, P.;
Meinhold, P. R.;
Melchiorri, A.;
Melin, J. -B.;
Mendes, L.;
Mennella, A.;
Mevi, C.;
Miniscalco, R.;
Mitra, S.;
Miville-Deschínes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Morisset, N.;
Mortlock, D.;
Munshi, D.;
Murphy, A.;
Naselsky, P.;
Natoli, P.;
Netterfield, C. B.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
O'Dwyer, I. J.;
Ortiz, I.;
Osborne, S.;
Osuna, P.;
Oxborrow, C. A.;
Pajot, F.;
Paladini, R.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Patanchon, G.;
Pearson, D.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Plaszczynski, S.;
Platania, P.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Prèzeau, G.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Reach, W. T.;
Rebolo, R.;
Reinecke, M.;
Reix, J. -M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Rowan-Robinson, M.;
Rubiñ-Martìn, J. A.;
Rusholme, B.;
Salerno, E.;
Sandri, M.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Scott, D.;
Seiffert, M. D.;
Shellard, P.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Starck, J. -L.;
Sternberg, J.;
Stivoli, F.;
Stolyarov, V.;
Stompor, R.;
Stringhetti, L.;
Sudiwala, R.;
Sunyaev, R.;
Sygnet, J. -F.;
Tapiador, D.;
Tauber, J. A.;
Tavagnacco, D.;
Taylor, D.;
Terenzi, L.;
Texier, D.;
Toffolatti, L.;
Tomasi, M.;
Torre, J. -P.;
Tristram, M.;
Tuovinen, J.;
Türler, M.;
Tuttlebee, M.;
Umana, G.;
Valenziano, L.;
Valiviita, J.;
Varis, J.;
Vibert, L.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Watson, C.;
White, S. D. M.;
White, M.;
Wilkinson, A.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2011-01-11, last modified: 2011-06-16
The European Space Agency's Planck satellite was launched on 14 May 2009, and
has been surveying the sky stably and continuously since 13 August 2009. Its
performance is well in line with expectations, and it will continue to gather
scientific data until the end of its cryogenic lifetime. We give an overview of
the history of Planck in its first year of operations, and describe some of the
key performance aspects of the satellite. This paper is part of a package
submitted in conjunction with Planck's Early Release Compact Source Catalogue,
the first data product based on Planck to be released publicly. The package
describes the scientific performance of the Planck payload, and presents
results on a variety of astrophysical topics related to the sources included in
the Catalogue, as well as selected topics on diffuse emission.
[8]
oai:arXiv.org:1007.5242 [pdf] - 1033997
One Centimetre Receiver Array-prototype observations of the CRATES
sources at 30 GHz
Peel, M. W.;
Gawronski, M. P.;
Battye, R. A.;
Birkinshaw, M.;
Browne, I. W. A.;
Davis, R. J.;
Feiler, R.;
Kus, A. J.;
Lancaster, K.;
Lowe, S. R.;
Pazderska, B. M.;
Pazderski, E.;
Roukema, B. F.;
Wilkinson, P. N.
Submitted: 2010-07-29, last modified: 2011-05-17
Knowledge of the population of radio sources in the range ~2-200 GHz is
important for understanding their effects on measurements of the Cosmic
Microwave Background power spectrum. We report measurements of the 30 GHz flux
densities of 605 radio sources from the Combined Radio All-sky Targeted
Eight-GHz Survey (CRATES), which have been made with the One Centimetre
Receiver Array prototype (OCRA-p) on the Torun 32-m telescope. The flux
densities of sources that were also observed by WMAP and previous OCRA surveys
are in broad agreement with those reported here, however a number of sources
display intrinsic variability. We find a good correlation between the 30 GHz
and Fermi gamma-ray flux densities for common sources. We examine the radio
spectra of all observed sources and report a number of Gigahertz-peaked and
inverted spectrum sources. These measurements will be useful for comparison to
those from the Low Frequency Instrument of the Planck satellite, which will
make some of its most sensitive observations in the region covered here.
[9]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[10]
oai:arXiv.org:0907.3994 [pdf] - 26588
Modelling the Galactic Magnetic Field on the Plane in 2D
Submitted: 2009-07-23, last modified: 2010-01-29
We present a method for parametric modelling of the physical components of
the Galaxy's magnetised interstellar medium, simulating the observables, and
mapping out the likelihood space using a Markov Chain Monte-Carlo analysis. We
then demonstrate it using total and polarised synchrotron emission data as well
as rotation measures of extragalactic sources. With these three datasets, we
define and study three components of the magnetic field: the large-scale
coherent field, the small-scale isotropic random field, and the ordered field.
In this first paper, we use only data along the Galactic plane and test a
simple 2D logarithmic spiral model for the magnetic field that includes a
compression and a shearing of the random component giving rise to an ordered
component. We demonstrate with simulations that the method can indeed constrain
multiple parameters yielding measures of, for example, the ratios of the
magnetic field components. Though subject to uncertainties in thermal and
cosmic ray electron densities and depending on our particular model
parametrisation, our preliminary analysis shows that the coherent component is
a small fraction of the total magnetic field and that an ordered component
comparable in strength to the isotropic random component is required to explain
the polarisation fraction of synchrotron emission. We outline further work to
extend this type of analysis to study the magnetic spiral arm structure, the
details of the turbulence as well as the 3D structure of the magnetic field.
[11]
oai:arXiv.org:1001.4778 [pdf] - 33192
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Valenziano, Luca;
Cuttaia, Francesco;
De Rosa, Adriano;
Terenzi, Luca;
Brighenti, Alberto;
Cazzola, GianPaolo;
Garbesi, Anna;
Mariotti, Sergio;
Orsi, Giordano;
Pagan, Luca;
Cavaliere, Francesco;
Lapini, Roberto;
Biggi, Matteo;
Panagin, Enzo;
Paola, Battaglia;
Butler, Chris;
Bersanelli, Marco;
D'Arcangelo, Ocleto;
Levin, Steve;
Mandolesi, Nazzareno;
Mennella, Aniello;
Morgante, Gianluca;
Morigi, Gabriele;
Sandri, Maura;
Simonetto, Alessandro;
Tomasi, Maurizio;
Villa, Fabrizio;
Frailis, Marco;
Galeotta, Samuele;
Gregorio, Anna;
Leonardi, Rodrigo;
Lowe, Stuart;
Maris, Michele;
Meinhold, Peter;
Mendes, Luis;
Stringhetti, Luca;
Zonca, Andrea;
Zacchei, Andrea
Submitted: 2010-01-26
The LFI radiometers use a pseudo-correlation design where the signal from the
sky is continuously compared with a stable reference signal, provided by a
cryogenic reference load system. The reference unit is composed by small
pyramidal horns, one for each radiometer, 22 in total, facing small absorbing
targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately
4.5 K. Horns and targets are separated by a small gap to allow thermal
decoupling. Target and horn design is optimized for each of the LFI bands,
centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the
radiometer 20K module or connected via external electro-formed bended
waveguides. The requirement of high stability of the reference signal imposed a
careful design for the radiometric and thermal properties of the loads.
Materials used for the manufacturing have been characterized for thermal, RF
and mechanical properties. We describe in this paper the design and the
performance of the reference system.
[12]
oai:arXiv.org:1001.4608 [pdf] - 33147
Noise Properties of the Planck-LFI Receivers
Meinhold, P.;
Leonardi, R.;
Aja, B.;
Artal, E.;
Battaglia, P.;
Bersanelli, M.;
Blackhurst, E.;
Butler, C. R.;
Cuevas, L. P.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R.;
de la Fuente, M. L.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gregorio, A.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Leutenegger, P.;
Lowe, S. R.;
Malaspina, M.;
Mandolesi, R.;
Maris, M.;
Martínez-González, E.;
Mendes, L.;
Mennella, A.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Seiffert, M.;
Salmón, M.;
Stringhetti, L.;
Poutanen, T.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Varis, J.;
Valenziano, L.;
Villa, F.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) radiometers have been tested
extensively during several dedicated campaigns. The present paper reports the
principal noise properties of the LFI radiometers.
[13]
oai:arXiv.org:1001.4610 [pdf] - 33148
The linearity response of the Planck-LFI flight model receivers
Mennella, A.;
Villa, F.;
Terenzi, L.;
Cuttaia, F.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
D'Arcangelo, O.;
Artal, E.;
Davis, R.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gregorio, A.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Kilpiä, V. -H.;
Laaninen, M.;
Lapolla, P. M.;
Leonardi, R.;
Leutenegger, P.;
Lowe, S.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Silvestri, R.;
Stringhetti, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Zacchei, A.;
Varis, J.;
Wilkinson, A.;
Zonca, A.
Submitted: 2010-01-26
In this paper we discuss the linearity response of the Planck-LFI receivers,
with particular reference to signal compression measured on the 30 and 44 GHz
channels. In the article we discuss the various sources of compression and
present a model that accurately describes data measured during tests performed
with individual radiomeric chains. After discussing test results we present the
best parameter set representing the receiver response and discuss the impact of
non linearity on in-flight calibration, which is shown to be negligible.
[14]
oai:arXiv.org:1001.4642 [pdf] - 33158
Off-line radiometric analysis of Planck/LFI data
Tomasi, M.;
Mennella, A.;
Galeotta, S.;
Lowe, S. R.;
Mendes, L.;
Leonardi, R.;
Villa, F.;
Cappellini, B.;
Gregorio, A.;
Meinhold, P.;
Sandri, M.;
Cuttaia, F.;
Terenzi, L.;
Maris, M.;
Valenziano, L.;
Salmon, M. J.;
Bersanelli, M.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschi, E.;
Gasparo, F.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Morgante, G.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) is an array of 22
pseudo-correlation radiometers on-board the Planck satellite to measure
temperature and polarization anisotropies in the Cosmic Microwave Background
(CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the
performances of the LFI, a software suite named LIFE has been developed. Its
aims are to provide a common platform to use for analyzing the results of the
tests performed on the single components of the instrument (RCAs, Radiometric
Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA).
Moreover, its analysis tools are designed to be used during the flight as well
to produce periodic reports on the status of the instrument. The LIFE suite has
been developed using a multi-layered, cross-platform approach. It implements a
number of analysis modules written in RSI IDL, each accessing the data through
a portable and heavily optimized library of functions written in C and C++. One
of the most important features of LIFE is its ability to run the same data
analysis codes both using ground test data and real flight data as input. The
LIFE software suite has been successfully used during the RCA/RAA tests and the
Planck Integrated System Tests. Moreover, the software has also passed the
verification for its in-flight use during the System Operations Verification
Tests, held in October 2008.
[15]
oai:arXiv.org:1001.4648 [pdf] - 33162
Planck-LFI radiometers tuning
Cuttaia, Francesco;
Mennella, Aniello;
Stringhetti, Luca;
Maris, Michele;
Terenzi, Luca;
Tomasi, Maurizio;
Villa, Fabrizio;
Bersanelli, Marco;
Butler, Christopher Reginald;
Cappellini, Benedetta;
Cuevas, Leticia Perez;
D'Arcangelo, Ocleto;
Davis, Richard;
Frailis, Marco;
Franceschet, Cristian;
Franceschi, Enrico;
Gregorio, Anna;
Hoyland, Roger;
Leonardi, Rodrigo;
Lowe, Stuart;
Mandolesi, Nazzareno;
Meinhold, Peter;
Mendes, Luis;
Roddis, Neil;
Sandri, Maura;
Valenziano, Luca;
Wilkinson, Althea;
Zacchei, Andrea;
Zonca, Andrea;
Battaglia, Paola;
De Nardo, Stefania;
Grassi, Stefano;
Lapolla, Marco;
Leutenegger, Paolo;
Miccolis, Maurizio;
Silvestri, Roberto
Submitted: 2010-01-26
"This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst"
This paper describes the Planck Low Frequency Instrument tuning activities
performed through the ground test campaigns, from Unit to Satellite Levels.
Tuning is key to achieve the best possible instrument performance and tuning
parameters strongly depend on thermal and electrical conditions. For this
reason tuning has been repeated several times during ground tests and it has
been repeated in flight before starting nominal operations. The paper discusses
the tuning philosophy, the activities and the obtained results, highlighting
developments and changes occurred during test campaigns. The paper concludes
with an overview of tuning performed during the satellite cryogenic test
campaign (Summer 2008) and of the plans for the just started in-flight
calibration.
[16]
oai:arXiv.org:1001.4730 [pdf] - 33178
Level 1 on-ground telemetry handling in Planck LFI
Zacchei, A.;
Frailis, M.;
Maris, M.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Maino, D.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meinhold, P.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave
Background (CMB) by covering the frequency range 30-70 GHz in three bands. The
primary instrument data source are the temperature samples acquired by the 22
radiometers mounted on the Planck focal plane. Such samples represent the
scientific data of LFI. In addition, the LFI instrument generates the so called
housekeeping data by sampling regularly the on-board sensors and registers. The
housekeeping data provides information on the overall health status of the
instrument and on the scientific data quality. The scientific and housekeeping
data are collected on-board into telemetry packets compliant with the ESA
Packet Telemetry standards. They represent the primary input to the first
processing level of the LFI Data Processing Centre. In this work we show the
software systems which build the LFI Level 1. A real-time assessment system,
based on the ESA SCOS 2000 generic mission control system, has the main purpose
of monitoring the housekeeping parameters of LFI and detect possible anomalies.
A telemetry handler system processes the housekeeping and scientific telemetry
of LFI, generating timelines for each acquisition chain and each housekeeping
parameter. Such timelines represent the main input to the subsequent processing
levels of the LFI DPC. A telemetry quick-look system allows the real-time
visualization of the LFI scientific and housekeeping data, by also calculating
quick statistical functions and fast Fourier transforms. The LFI Level 1 has
been designed to support all the mission phases, from the instrument ground
tests and calibration to the flight operations, and developed according to the
ESA engineering standards.
[17]
oai:arXiv.org:1001.4743 [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end
modules for the Planck Low Frequency Instrument
Davis, R. J.;
Wilkinson, A.;
Davies, R. D.;
Winder, W. F.;
Roddis, N.;
Blackhurst, E. J.;
Lawson, D.;
Lowe, S. R.;
Baines, C.;
Butlin, M.;
Galtress, A.;
Shepherd, D.;
Aja, B.;
Artal, E.;
Bersanelli, M.;
Butler, R. C.;
Castelli, C.;
Cuttaia, F.;
D'Arcangelo, O.;
Gaier, T.;
Hoyland, R.;
Kettle, D.;
Leonardi, R.;
Mandolesi, N.;
Mennella, A.;
Meinhold, P.;
Pospieszalski, M.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zonca, A.
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.
[18]
oai:arXiv.org:1001.4838 [pdf] - 33213
A systematic approach to the Planck LFI end-to-end test and its
application to the DPC Level 1 pipeline
Frailis, M.;
Maris, M.;
Zacchei, A.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Lowe, S. R.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the
handling of the scientific and housekeeping telemetry. It is a critical
component of the Planck ground segment which has to strictly commit to the
project schedule to be ready for the launch and flight operations. In order to
guarantee the quality necessary to achieve the objectives of the Planck
mission, the design and development of the Level 1 software has followed the
ESA Software Engineering Standards. A fundamental step in the software life
cycle is the Verification and Validation of the software. The purpose of this
work is to show an example of procedures, test development and analysis
successfully applied to a key software project of an ESA mission. We present
the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by
detailing the methods used and the results obtained. Different approaches have
been used to test the scientific and housekeeping data processing. Scientific
data processing has been tested by injecting signals with known properties
directly into the acquisition electronics, in order to generate a test dataset
of real telemetry data and reproduce as much as possible nominal conditions.
For the HK telemetry processing, validation software have been developed to
inject known parameter values into a set of real housekeeping packets and
perform a comparison with the corresponding timelines generated by the Level 1.
With the proposed validation and verification procedure, where the on-board and
ground processing are viewed as a single pipeline, we demonstrated that the
scientific and housekeeping processing of the Planck-LFI raw data is correct
and meets the project requirements.
[19]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[20]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[21]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[22]
oai:arXiv.org:0909.1189 [pdf] - 1017403
30 GHz observations of sources in the VSA fields
Gawronski, M. P.;
Peel, M. W.;
Lancaster, K.;
Battye, R. A.;
Birkinshaw, M.;
Browne, I. W. A.;
Davies, M. L.;
Davis, R. J.;
Feiler, R.;
Franzen, T. M. O.;
Genova-Santos, R.;
Kus, A. J.;
Lowe, S. R.;
Pazderska, B. M.;
Pazderski, E.;
Pooley, G. G.;
Roukema, B. F.;
Waldram, E. M.;
Wilkinson, P. N.
Submitted: 2009-09-07
Small angular scale (high l) studies of cosmic microwave background
anisotropies require accurate knowledge of the statistical properties of
extragalactic sources at cm-mm wavelengths. We have used a 30 GHz dual-beam
receiver (OCRA-p) on the Torun 32-m telescope to measure the flux densities of
121 sources in VSA fields selected at 15 GHz with the Ryle Telescope. We have
detected 57 sources above a limiting flux density of 5mJy, of which 31 sources
have a flux density greater than 10mJy, which is our effective completeness
limit. From these measurements we derive a surface density of sources above
10mJy at 30 GHz of 2.0+/-0.4 per square degree. This is consistent with the
surface density obtained by Mason et al. (2009) who observed a large sample of
sources selected at a much lower frequency (1.4 GHz). We have also investigated
the dependence of the spectral index distribution on flux density by comparing
our results with those for sources above 1 Jy selected from the WMAP 22 GHz
catalogue. We conclude that the proportion of steep spectrum sources increases
with decreasing flux density, qualitatively consistent with the predictions of
deZotti et al. (2005). We find no evidence for an unexpected population of
sources whose spectra rise towards high frequencies, which would affect our
ability to interpret current high resolution CMB observations at 30 GHz and
above.
[23]
oai:arXiv.org:0907.0193 [pdf] - 25870
AstroTwitter
Submitted: 2009-07-01
AstroTwitter aims to make it easy for both professional and amateur
telescopes to let the world know what they are observing in real-time.
[24]
oai:arXiv.org:0902.3945 [pdf] - 1001503
Survey of Planetary Nebulae at 30 GHz with OCRA-p
Pazderska, B. M.;
Gawronski, M. P.;
Feiler, R.;
Birkinshaw, M.;
Browne, I. W. A.;
Davis, R.;
Kus, A. J.;
Lancaster, K.;
Lowe, S. R.;
Pazderski, E.;
Peel, M.;
Wilkinson, P. N.
Submitted: 2009-02-23
We report the results of a survey of 442 planetary nebulae at 30 GHz. The
purpose of the survey is to develop a list of planetary nebulae as calibration
sources which could be used for high frequency calibration in future. For 41
PNe with sufficient data, we test the emission mechanisms in order to evaluate
whether or not spinning dust plays an important role in their spectra at 30
GHz.
The 30-GHz data were obtained with a twin-beam differencing radiometer,
OCRA-p, which is in operation on the Torun 32-m telescope. Sources were scanned
both in right ascension and declination. We estimated flux densities at 30 GHz
using a free-free emission model and compared it with our data.
The primary result is a catalogue containing the flux densities of 93
planetary nebulae at 30 GHz. Sources with sufficient data were compared with a
spectral model of free-free emission. The model shows that free-free emission
can generally explain the observed flux densities at 30 GHz thus no other
emission mechanism is needed to account for the high frequency spectra.
[25]
oai:arXiv.org:0707.3368 [pdf] - 3343
30 GHz flux density measurements of the Caltech-Jodrell flat-spectrum
sources with OCRA-p
Submitted: 2007-07-23
To measure the 30-GHz flux densities of the 293 sources in the
Caltech-Jodrell Bank flat-spectrum (CJF) sample. The measurements are part of
an ongoing programme to measure the spectral energy distributions of flat
spectrum radio sources and to correlate them with the milliarcsecond structures
from VLBI and other measured astrophysical properties. The 30-GHz data were
obtained with a twin-beam differencing radiometer system mounted on the Torun
32-m telescope. The system has an angular resolution of 1.2 arcmin. Together
with radio spectral data obtained from the literature, the 30-GHz data have
enabled us to identify 42 of the CJF sources as Giga-hertz Peaked Spectrum
(GPS) sources. Seventeen percent of the sources have rising spectra (alpha > 0)
between 5 and 30 GHz.
[26]
oai:arXiv.org:0705.3336 [pdf] - 1537
Preliminary Sunyaev Zel'dovich Observations of Galaxy Clusters with
OCRA-p
Submitted: 2007-05-23
We present 30 GHz Sunyaev Zel'dovich (SZ) observations of a sample of four
galaxy clusters with a prototype of the One Centimetre Receiver Array (OCRA-p)
which is mounted on the Torun 32-m telescope. The clusters (Cl0016+16,
MS0451.6-0305, MS1054.4-0321 and Abell 2218) are popular SZ targets and serve
as commissioning observations. All four are detected with clear significance
(4-6 sigma) and values for the central temperature decrements are in good
agreement with measurements reported in the literature. We believe that
systematic effects are successfully suppressed by our observing strategy. The
relatively short integration times required to obtain these results demonstrate
the power of OCRA-p and its successors for future SZ studies.