Normalized to: Loupias, M.
[1]
oai:arXiv.org:2003.05714 [pdf] - 2063822
SPHERE+: Imaging young Jupiters down to the snowline
Boccaletti, A.;
Chauvin, G.;
Mouillet, D.;
Absil, O.;
Allard, F.;
Antoniucci, S.;
Augereau, J. -C.;
Barge, P.;
Baruffolo, A.;
Baudino, J. -L.;
Baudoz, P.;
Beaulieu, M.;
Benisty, M.;
Beuzit, J. -L.;
Bianco, A.;
Biller, B.;
Bonavita, B.;
Bonnefoy, M.;
Bos, S.;
Bouret, J. -C.;
Brandner, W.;
Buchschache, N.;
Carry, B.;
Cantalloube, F.;
Cascone, E.;
Carlotti, A.;
Charnay, B.;
Chiavassa, A.;
Choquet, E.;
Clenet, Y.;
Crida, A.;
De Boer, J.;
De Caprio, V.;
Desidera, S.;
Desert, J. -M.;
Delisle, J. -B.;
Delorme, P.;
Dohlen, K.;
Doelman, D.;
Dominik, C.;
Orazi, V. D;
Dougados, C.;
Doute, S.;
Fedele, D.;
Feldt, M.;
Ferreira, F.;
Fontanive, C.;
Fusco, T.;
Galicher, R.;
Garufi, A.;
Gendron, E.;
Ghedina, A.;
Ginski, C.;
Gonzalez, J. -F.;
Gratadour, D.;
Gratton, R.;
Guillot, T.;
Haffert, S.;
Hagelberg, J.;
Henning, T.;
Huby, E.;
Janson, M.;
Kamp, I.;
Keller, C.;
Kenworthy, M.;
Kervella, P.;
Kral, Q.;
Kuhn, J.;
Lagadec, E.;
Laibe, G.;
Langlois, M.;
Lagrange, A. -M.;
Launhardt, R.;
Leboulleux, L.;
Coroller, H. Le;
Causi, G. Li;
Loupias, M.;
Maire, A. L.;
Marleau, G.;
Martinache, F.;
Martinez, P.;
Mary, D.;
Mattioli, M.;
Mazoyer, J.;
Meheut, H.;
Menard, F.;
Mesa, D.;
Meunier, N.;
Miguel, Y.;
Milli, J.;
Min, M.;
Molliere, P.;
Mordasini, C.;
Moretto, G.;
Mugnier, L.;
Arena, G. Muro;
Nardetto, N.;
Diaye, M. N;
Nesvadba, N.;
Pedichini, F.;
Pinilla, P.;
Por, E.;
Potier, A.;
Quanz, S.;
Rameau, J.;
Roelfsema, R.;
Rouan, D.;
Rigliaco, E.;
Salasnich, B.;
Samland, M.;
Sauvage, J. -F.;
Schmid, H. -M.;
Segransan, D.;
Snellen, I.;
Snik, F.;
Soulez, F.;
Stadler, E.;
Stam, D.;
Tallon, M.;
Thebault, P.;
Thiebaut, E.;
Tschudi, C.;
Udry, S.;
van Holstein, R.;
Vernazza, P.;
Vidal, F.;
Vigan, A.;
Waters, R.;
Wildi, F.;
Willson, M.;
Zanutta, A.;
Zavagno, A.;
Zurlo, A.
Submitted: 2020-03-12, last modified: 2020-03-13
SPHERE (Beuzit et al,. 2019) has now been in operation at the VLT for more
than 5 years, demonstrating a high level of performance. SPHERE has produced
outstanding results using a variety of operating modes, primarily in the field
of direct imaging of exoplanetary systems, focusing on exoplanets as point
sources and circumstellar disks as extended objects. The achievements obtained
thus far with SPHERE (~200 refereed publications) in different areas
(exoplanets, disks, solar system, stellar physics...) have motivated a large
consortium to propose an even more ambitious set of science cases, and its
corresponding technical implementation in the form of an upgrade. The SPHERE+
project capitalizes on the expertise and lessons learned from SPHERE to push
high contrast imaging performance to its limits on the VLT 8m-telescope. The
scientific program of SPHERE+ described in this document will open a new and
compelling scientific window for the upcoming decade in strong synergy with
ground-based facilities (VLT/I, ELT, ALMA, and SKA) and space missions (Gaia,
JWST, PLATO and WFIRST). While SPHERE has sampled the outer parts of planetary
systems beyond a few tens of AU, SPHERE+ will dig into the inner regions around
stars to reveal and characterize by mean of spectroscopy the giant planet
population down to the snow line. Building on SPHERE's scientific heritage and
resounding success, SPHERE+ will be a dedicated survey instrument which will
strengthen the leadership of ESO and the European community in the very
competitive field of direct imaging of exoplanetary systems. With enhanced
capabilities, it will enable an even broader diversity of science cases
including the study of the solar system, the birth and death of stars and the
exploration of the inner regions of active galactic nuclei.
[2]
oai:arXiv.org:1807.06313 [pdf] - 1717330
ELT HARMONI: Image Slicer Preliminary Design
Laurent, Florence;
Boudon, Didier;
Kosmalski, Johan;
Loupias, Magali;
Raffault, Guillaume;
Remillieux, Alban;
Thatte, Niranjan;
Bryson, Ian;
Schnetler, Hermine;
Clarke, Fraser;
Tecza, Matthias
Submitted: 2018-07-17
Harmoni is the ELT's first light visible and near-infrared integral field
spectrograph. It will provide four different spatial scales, ranging from
coarse spaxels of 60 x 30 mas best suited for seeing limited observations, to 4
mas spaxels that Nyquist sample the diffraction limited point spread function
of the ELT at near-infrared wavelengths. Each spaxel scale may be combined with
eleven spectral settings, that provide a range of spectral resolving powers
from R 3500 to R 20000 and instantaneous wavelength coverage spanning the 0.47
- 2.45 {\mu}m wavelength range of the instrument. The consortium consists of
several institutes in Europe under leadership of Oxford University. Harmoni is
starting its Final Design Phase after a Preliminary Design Phase in November,
2017. The CRAL has the responsibility of the Integral Field Unit design linking
the Preoptics to the 4 Spectrographs. It is composed of a field splitter
associated with a relay system and an image slicer that create from a
rectangular Field of View a very long (540mm) output slit for each
spectrograph. In this paper, the preliminary design and performances of Harmoni
Image Slicer will be presented including image quality, pupil distortion and
slit geometry. It has been designed by CRAL for Harmoni PDR in November, 2017.
Special emphases will be put on straylight analysis and slice diffraction. The
optimisation of the manufacturing and slit geometry will also be reported.
[3]
oai:arXiv.org:1509.08358 [pdf] - 1284118
Development of an ELT XAO testbed using a Mach-Zehnder wavefront sensor:
calibration of the deformable mirror
Submitted: 2015-09-28
(abridged) Extreme adaptive optics (XAO) encounters severe difficulties to
cope with the high speed (>1kHz), high accuracy and high order requirements for
future extremely large telescopes. An innovative high order adaptive optics
system using a self-referenced Mach-Zehnder wavefront sensor (MZWFS) allows
counteracting these limitations. This sensor estimates very accurately the
wavefront phase at small spatial scale by measuring intensity differences
between two outputs, with a $\lambda /4$ path length difference between its two
legs, but is limited in dynamic range due to phase ambiguity. During the past
few years, such an XAO system has been studied by our team in the framework of
8-meter class telescopes. In this work, we report on our latest results with
the XAO testbed recently installed in our lab, and dedicated to high contrast
imaging with 30m-class telescopes (such as the E-ELT or the TMT). After
reminding the principle of a MZWFS and describing the optical layout of our
experiment, we will show the results of the assessment of the woofer-tweeter
phase correctors, i.e., a Boston Micromachine continuous membrane deformable
mirror (DM) and a Boulder Nonlinear Systems liquid crystal spatial light
modulator (SLM). In particular, we will detail the calibration of the DM using
Zygo interferometer metrology. Our method consists in the precise measurement
of the membrane deformation while applying a constant deformation to 9 out of
140 actuators at the same time. By varying the poke voltage across the DM
operating range, we propose a simple but efficient way of modeling the DM
influence function using a Gaussian model. Finally, we show the DM flattening
on the MZWFS allowing to compensate for low order aberrations.
[4]
oai:arXiv.org:astro-ph/0606329 [pdf] - 1233815
Probing unexplored territories with MUSE: a second generation instrument
for the VLT
Bacon, R.;
Bauer, S.;
Boehm, P.;
Boudon, D.;
Brau-Nogue, S.;
Caillier, P.;
Capoani, L.;
Carollo, C. M.;
Champavert, N.;
Contini, T.;
Daguise, E.;
Dalle, D.;
Delabre, B.;
Devriendt, J.;
Dreizler, S.;
Dubois, J.;
Dupieux, M.;
Dupin, J. P.;
Emsellem, E.;
Ferruit, P.;
Franx, M.;
Gallou, G.;
Gerssen, J.;
Guiderdoni, B.;
Hahn, T.;
Hofmann, D.;
Jarno, A.;
Kelz, A.;
Koehler, C.;
Kollatschny, W.;
Kosmalski, J.;
Laurent, F.;
Lilly, S. J.;
Lizon, J.;
Loupias, M.;
Lynn, S.;
Manescau, A.;
McDermid, R. M.;
Monstein, C.;
Nicklas, H.;
Pares, L.;
Pasquini, L.;
Pecontal-Rousset, A.;
Pecontal, E.;
Pello, R.;
Petit, C.;
Picat, J. -P.;
Popow, E.;
Quirrenbach, A.;
Reiss, R.;
Renault, E.;
Roth, M.;
Schaye, J.;
Soucail, G.;
Steinmetz, M.;
Stroebele, S.;
Stuik, R.;
Weilbacher, P.;
Wozniak, H.;
de Zeeuw, P. T.
Submitted: 2006-06-13
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT
panoramic integral-field spectrograph under preliminary design study. MUSE has
a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the
VLT ground layer adaptive optics ESO facility using four laser guide stars. The
simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE
couples the discovery potential of a large imaging device to the measuring
capabilities of a high-quality spectrograph, while taking advantage of the
increased spatial resolution provided by adaptive optics. This makes MUSE a
unique and tremendously powerful instrument for discovering and characterizing
objects that lie beyond the reach of even the deepest imaging surveys. MUSE has
also a high spatial resolution mode with 7.5x7.5 arcsec**2 field of view
sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain
diffraction limited data-cubes in the 600-930 nm wavelength range. Although the
MUSE design has been optimized for the study of galaxy formation and evolution,
it has a wide range of possible applications; e.g. monitoring of outer planets
atmosphere, environment of young stellar objects, super massive black holes and
active nuclei in nearby galaxies or massive spectroscopic surveys of stellar
fields in the Milky Way and nearby galaxies.