Normalized to: Lorenzon, W.
[1]
oai:arXiv.org:1802.06039 [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.;
Akerlof, C. W.;
Alsum, S. K.;
Araújo, H. M.;
Arthurs, M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Bauer, D.;
Belle, J.;
Beltrame, P.;
Benson, T.;
Bernard, E. P.;
Biesiadzinski, T. P.;
Boast, K. E.;
Boxer, B.;
Brás, P.;
Buckley, J. H.;
Bugaev, V. V.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Chan, C.;
Cherwinka, J. J.;
Cole, A.;
Cottle, A.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
Dahl, C. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, W. R.;
Fan, A.;
Fayer, S.;
Fiorucci, S.;
Fruth, T.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
van der Grinten, M. G. D.;
Hall, C. R.;
Hans, S.;
Hanzel, K.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hillbrand, S.;
Hjemfelt, C.;
Hoff, M. D.;
Hor, J. Y-K.;
Huang, D. Q.;
Ignarra, C. M.;
Ji, W.;
Kaboth, A. C.;
Kamdin, K.;
Keefner, J.;
Khaitan, D.;
Khazov, A.;
Kim, Y. D.;
Kocher, C. D.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kreczko, L.;
Krikler, B.;
Kudryavtsev, V. A.;
Kyre, S.;
Lee, J.;
Lenardo, B. G.;
Leonard, D. S.;
Lesko, K. T.;
Levy, C.;
Li, J.;
Liao, J.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Linehan, R.;
Lippincott, W. H.;
Liu, X.;
Lopes, M. I.;
Paredes, B. López;
Lorenzon, W.;
Luitz, S.;
Lyle, J. M.;
Majewski, P.;
Manalaysay, A.;
Mannino, R. L.;
Maupin, C.;
McKinsey, D. N.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Morrison, E.;
Mount, B. J.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikoleyczik, J.;
O'Sullivan, K.;
Olcina, I.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Patton, S. J.;
Pease, E. K.;
Penning, B.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Rhyne, C. A.;
Richards, A.;
Rodrigues, J. P.;
Rosero, R.;
Rossiter, P.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silk, J. J.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stancu, I.;
Stark, M. R.;
Stiegler, T. M.;
Stifter, K.;
Szydagis, M.;
Taylor, W. C.;
Taylor, R.;
Taylor, D. J.;
Temples, D.;
Terman, P. A.;
Thomas, K. J.;
Timalsina, M.;
To, W. H.;
Tomás, A.;
Tope, T. E.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Utku, U.;
Va'vra, J.;
Vacheret, A.;
Verbus, J. R.;
Voirin, E.;
Waldron, W. L.;
Watson, J. R.;
Webb, R. C.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, I.
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well
underway, LZ is on track for commissioning at SURF in 2020.
[4]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[5]
oai:arXiv.org:1505.00771 [pdf] - 1280844
Low-mass dark matter search results from full exposure of PandaX-I
experiment
PandaX Collaboration;
Xiao, Xiang;
Chen, Xun;
Tan, Andi;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl L.;
Gong, Haowei;
Guo, Guodong;
He, Ming;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Lin, Qing;
Liu, Huaxuan;
Liu, Jianglai;
Liu, Xiang;
Lorenzon, Wolfgang;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixuan;
Pushkin, Kirill;
Ren, Xiangxiang;
Schubnell, Michael;
Shen, Manbin;
Shi, Yuji;
Stephenson, Scott;
Wang, Hongwei;
Wang, Jiming;
Wang, Meng;
Wang, Siguang;
Wang, Xuming;
Wang, Zhou;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
You, Yinghui;
Zeng, Xionghui;
Zhang, Tao;
Zhao, Li;
Zhou, Xiaopeng;
Zhu, Zhonghua
Submitted: 2015-05-04, last modified: 2015-08-20
We report the results of a weakly-interacting massive particle (WIMP) dark
matter search using the full 80.1\;live-day exposure of the first stage of the
PandaX experiment (PandaX-I) located in the China Jin-Ping Underground
Laboratory. The PandaX-I detector has been optimized for detecting low-mass
WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid
xenon target mass of 54.0\,kg, no significant excess event were found above the
expected background. A profile likelihood analysis confirms our earlier finding
that the PandaX-I data disfavor all positive low-mass WIMP signals reported in
the literature under standard assumptions. A stringent bound on the low mass
WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon
detectors can be competitive for low-mass WIMP searches.
[6]
oai:arXiv.org:1408.5114 [pdf] - 863825
First dark matter search results from the PandaX-I experiment
PandaX Collaboration;
Xiao, Mengjiao;
Xiao, Xiang;
Zhao, Li;
Cao, Xiguang;
Chen, Xun;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl L.;
Gong, Haowei;
Guo, Guodong;
Hu, Jie;
Huang, Xingtao;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Lin, Qing;
Liu, Huaxuan;
Liu, Jianglai;
Liu, Xiang;
Lorenzon, Wolfgang;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixuan;
Pushkin, Kirill;
Ren, Xiangxiang;
Schubnell, Michael;
Shen, Manbing;
Stephenson, Scott;
Tan, Andi;
Tarle, Greg;
Wang, Hongwei;
Wang, Jimin;
Wang, Meng;
Wang, Xuming;
Wang, Zhou;
Wei, Yuehuan;
Wu, Shiyong;
Xie, Pengwei;
You, Yinghui;
Zeng, Xionghui;
Zhang, Hua;
Zhang, Tao;
Zhu, Zhonghua
Submitted: 2014-08-21, last modified: 2014-09-04
We report on the first dark-matter (DM) search results from PandaX-I, a low
threshold dual-phase xenon experiment operating at the China Jinping
Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of
exposure, no DM particle candidate event was found. This result sets a
stringent limit for low-mass DM particles and disfavors the interpretation of
previously-reported positive experimental results. The minimum upper limit,
$3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar
DM-particle-nucleon scattering cross section is obtained at a DM-particle mass
of 49\,GeV/c$^2$ at 90\% confidence level.
[7]
oai:arXiv.org:1208.0865 [pdf] - 1150515
PreCam, a Precursor Observational Campaign for Calibration of the Dark
Energy Survey
Kuehn, K.;
Kuhlmann, S.;
Allam, S.;
Annis, J. T.;
Bailey, T.;
Balbinot, E.;
Bernstein, J. P.;
Biesiadzinski, T.;
Burke, D. L.;
Butner, M.;
Camargo, J. I. B.;
da Costa, L. A. N.;
DePoy, D.;
Diehl, H. T.;
Dietrich, J. P.;
Estrada, J.;
Fausti, A.;
Gerke, B.;
Guarino, V.;
Head, H. H.;
Kessler, R.;
Lin, H.;
Lorenzon, W.;
Maia, M. A. G.;
Maki, L.;
Marshall, J.;
Nord, B.;
Neilsen, E.;
Ogando, R. L. C.;
Park, D.;
Peoples, J.;
Rastawicki, D.;
Rheault, J. -P.;
Santiago, B.;
Schubnell, M.;
Seitzer, P.;
Smith, J. A.;
Spinka, H.;
Sypniewski, A.;
Tarle, G.;
Tucker, D. L.;
Walker, A.;
Wester, W.
Submitted: 2012-08-03
PreCam, a precursor observational campaign supporting the Dark Energy Survey
(DES), is designed to produce a photometric and astrometric catalog of nearly a
hundred thousand standard stars within the DES footprint, while the PreCam
instrument also serves as a prototype testbed for the Dark Energy Camera
(DECam)'s hardware and software. This catalog represents a potential 100-fold
increase in Southern Hemisphere photometric standard stars, and therefore will
be an important component in the calibration of the Dark Energy Survey. We
provide details on the PreCam instrument's design, construction and testing, as
well as results from a subset of the 51 nights of PreCam survey observations on
the University of Michigan Department of Astronomy's Curtis-Schmidt telescope
at Cerro Tololo Inter-American Observatory. We briefly describe the preliminary
data processing pipeline that has been developed for PreCam data and the
preliminary results of the instrument performance, as well as astrometry and
photometry of a sample of stars previously included in other southern sky
surveys.
[8]
oai:arXiv.org:1106.1706 [pdf] - 371192
The BigBOSS Experiment
Schlegel, D.;
Abdalla, F.;
Abraham, T.;
Ahn, C.;
Prieto, C. Allende;
Annis, J.;
Aubourg, E.;
Azzaro, M.;
Baltay, S. Bailey. C.;
Baugh, C.;
Bebek, C.;
Becerril, S.;
Blanton, M.;
Bolton, A.;
Bromley, B.;
Cahn, R.;
Carton, P. -H.;
Cervantes-Cota, J. L.;
Chu, Y.;
Cortes, M.;
Dawson, K.;
Dey, A.;
Dickinson, M.;
Diehl, H. T.;
Doel, P.;
Ealet, A.;
Edelstein, J.;
Eppelle, D.;
Escoffier, S.;
Evrard, A.;
Faccioli, L.;
Frenk, C.;
Geha, M.;
Gerdes, D.;
Gondolo, P.;
Gonzalez-Arroyo, A.;
Grossan, B.;
Heckman, T.;
Heetderks, H.;
Ho, S.;
Honscheid, K.;
Huterer, D.;
Ilbert, O.;
Ivans, I.;
Jelinsky, P.;
Jing, Y.;
Joyce, D.;
Kennedy, R.;
Kent, S.;
Kieda, D.;
Kim, A.;
Kim, C.;
Kneib, J. -P.;
Kong, X.;
Kosowsky, A.;
Krishnan, K.;
Lahav, O.;
Lampton, M.;
LeBohec, S.;
Brun, V. Le;
Levi, M.;
Li, C.;
Liang, M.;
Lim, H.;
Lin, W.;
Linder, E.;
Lorenzon, W.;
de la Macorra, A.;
Magneville, Ch.;
Malina, R.;
Marinoni, C.;
Martinez, V.;
Majewski, S.;
Matheson, T.;
McCloskey, R.;
McDonald, P.;
McKay, T.;
McMahon, J.;
Menard, B.;
Miralda-Escude, J.;
Modjaz, M.;
Montero-Dorta, A.;
Morales, I.;
Mostek, N.;
Newman, J.;
Nichol, R.;
Nugent, P.;
Olsen, K.;
Padmanabhan, N.;
Palanque-Delabrouille, N.;
Park, I.;
Peacock, J.;
Percival, W.;
Perlmutter, S.;
Peroux, C.;
Petitjean, P.;
Prada, F.;
Prieto, E.;
Prochaska, J.;
Reil, K.;
Rockosi, C.;
Roe, N.;
Rollinde, E.;
Roodman, A.;
Ross, N.;
Rudnick, G.;
Ruhlmann-Kleider, V.;
Sanchez, J.;
Sawyer, D.;
Schimd, C.;
Schubnell, M.;
Scoccimaro, R.;
Seljak, U.;
Seo, H.;
Sheldon, E.;
Sholl, M.;
Shulte-Ladbeck, R.;
Slosar, A.;
Smith, D. S.;
Smoot, G.;
Springer, W.;
Stril, A.;
Szalay, A. S.;
Tao, C.;
Tarle, G.;
Taylor, E.;
Tilquin, A.;
Tinker, J.;
Valdes, F.;
Wang, J.;
Wang, T.;
Weaver, B. A.;
Weinberg, D.;
White, M.;
Wood-Vasey, M.;
Yang, J.;
Yeche, X. Yang. Ch.;
Zakamska, N.;
Zentner, A.;
Zhai, C.;
Zhang, P.
Submitted: 2011-06-09
BigBOSS is a Stage IV ground-based dark energy experiment to study baryon
acoustic oscillations (BAO) and the growth of structure with a wide-area galaxy
and quasar redshift survey over 14,000 square degrees. It has been
conditionally accepted by NOAO in response to a call for major new
instrumentation and a high-impact science program for the 4-m Mayall telescope
at Kitt Peak. The BigBOSS instrument is a robotically-actuated, fiber-fed
spectrograph capable of taking 5000 simultaneous spectra over a wavelength
range from 340 nm to 1060 nm, with a resolution R = 3000-4800.
Using data from imaging surveys that are already underway, spectroscopic
targets are selected that trace the underlying dark matter distribution. In
particular, targets include luminous red galaxies (LRGs) up to z = 1.0,
extending the BOSS LRG survey in both redshift and survey area. To probe the
universe out to even higher redshift, BigBOSS will target bright [OII] emission
line galaxies (ELGs) up to z = 1.7. In total, 20 million galaxy redshifts are
obtained to measure the BAO feature, trace the matter power spectrum at smaller
scales, and detect redshift space distortions. BigBOSS will provide additional
constraints on early dark energy and on the curvature of the universe by
measuring the Ly-alpha forest in the spectra of over 600,000 2.2 < z < 3.5
quasars.
BigBOSS galaxy BAO measurements combined with an analysis of the broadband
power, including the Ly-alpha forest in BigBOSS quasar spectra, achieves a FOM
of 395 with Planck plus Stage III priors. This FOM is based on conservative
assumptions for the analysis of broad band power (kmax = 0.15), and could grow
to over 600 if current work allows us to push the analysis to higher wave
numbers (kmax = 0.3). BigBOSS will also place constraints on theories of
modified gravity and inflation, and will measure the sum of neutrino masses to
0.024 eV accuracy.
[9]
oai:arXiv.org:1106.1090 [pdf] - 1077095
Reciprocity Failure in HgCdTe Detectors: Measurements and Mitigation
Submitted: 2011-06-06
A detailed study of reciprocity failure in four 1.7 micron cutoff HgCdTe
near-infrared detectors is presented. The sensitivity to reciprocity failure is
approximately 0.1%\decade over up to five orders of magnitude in illumination
intensity. The four detectors, which represent three successive production runs
with modified growth recipes, show large differences in amount and spatial
structure of reciprocity failure. Reciprocity failure could be reduced to
negligible levels by cooling the detectors to about 110 K. No wavelength
dependence was observed. The observed spatial structure appears to be weakly
correlated with image persistence.
[10]
oai:arXiv.org:1012.2411 [pdf] - 1042503
Measurement of Reciprocity Failure in Near Infrared Detectors
Submitted: 2010-12-10
Flux dependent non-linearity (reciprocity failure) in HgCdTe near infrared
detectors can severely impact an instrument's performance, in particular with
respect to precision photometric measurements. The cause of this effect is
presently not understood. To investigate reciprocity failure, a dedicated test
system was built. For flux levels between 1 and 50,000 photons/s, a sensitivity
to reciprocity failure of approximately 0.1%/decade was achieved. A wavelength
independent non-linearity due to reciprocity failure of about 0.35%/decade was
measured in a 1.7 micron HgCdTe detector.
[11]
oai:arXiv.org:1008.3369 [pdf] - 1034382
Investigating reciprocity failure in 1.7-micron cut-off HgCdTe detectors
Submitted: 2010-08-19
Flux dependent non-linearity (reciprocity failure) in HgCdTe NIR detectors
with 1.7 micron cut-off was investigated. A dedicated test station was designed
and built to measure reciprocity failure over the full dynamic range of near
infrared detectors. For flux levels between 1 and 100,000 photons/sec a
limiting sensitivity to reciprocity failure of 0.3%/decade was achieved. First
measurements on several engineering grade 1.7 micron cut-off HgCdTe detectors
show a wide range of reciprocity failure, from less than 0.5%/decade to about
10%/decade. For at least two of the tested detectors, significant spatial
variation in the effect was observed. No indication for wavelength dependency
was found. The origin of reciprocity failure is currently not well understood.
In this paper we present details of our experimental set-up and show the
results of measurements for several detectors.
[12]
oai:arXiv.org:astro-ph/0611339 [pdf] - 86725
Sub-Pixel Response Measurement of Near-Infrared Sensors
Submitted: 2006-11-10
Wide-field survey instruments are used to efficiently observe large regions
of the sky. To achieve the necessary field of view, and to provide a higher
signal-to-noise ratio for faint sources, many modern instruments are
undersampled. However, precision photometry with undersampled imagers requires
a detailed understanding of the sensitivity variations on a scale much smaller
than a pixel. To address this, a near-infrared spot projection system has been
developed to precisely characterize near-infrared focal plane arrays and to
study the effect of sub-pixel non uniformity on precision photometry.
Measurements of large format near-infrared detectors demonstrate the power of
this system for understanding sub-pixel response.
[13]
oai:arXiv.org:astro-ph/0405232 [pdf] - 64752
Supernova / Acceleration Probe: A Satellite Experiment to Study the
Nature of the Dark Energy
SNAP Collaboration;
Aldering, G.;
Althouse, W.;
Amanullah, R.;
Annis, J.;
Astier, P.;
Baltay, C.;
Barrelet, E.;
Basa, S.;
Bebek, C.;
Bergstrom, L.;
Bernstein, G.;
Bester, M.;
Bigelow, B.;
Blandford, R.;
Bohlin, R.;
Bonissent, A.;
Bower, C.;
Brown, M.;
Campbell, M.;
Carithers, W.;
Commins, E.;
Craig, W.;
Day, C.;
DeJongh, F.;
Deustua, S.;
Diehl, T.;
Dodelson, S.;
Ealet, A.;
Ellis, R.;
Emmet, W.;
Fouchez, D.;
Frieman, J.;
Fruchter, A.;
Gerdes, D.;
Gladney, L.;
Goldhaber, G.;
Goobar, A.;
Groom, D.;
Heetderks, H.;
Hoff, M.;
Holland, S.;
Huffer, M.;
Hui, L.;
Huterer, D.;
Jain, B.;
Jelinsky, P.;
Karcher, A.;
Kent, S.;
Kahn, S.;
Kim, A.;
Kolbe, W.;
Krieger, B.;
Kushner, G.;
Kuznetsova, N.;
Lafever, R.;
Lamoureux, J.;
Lampton, M.;
Fevre, O. Le;
Levi, M.;
Limon, P.;
Lin, H.;
Linder, E.;
Loken, S.;
Lorenzon, W.;
Malina, R.;
Marriner, J.;
Marshall, P.;
Massey, R.;
Mazure, A.;
McKay, T.;
McKee, S.;
Miquel, R.;
Morgan, N.;
Mortsell, E.;
Mostek, N.;
Mufson, S.;
Musser, J.;
Nugent, P.;
Oluseyi, H.;
Pain, R.;
Palaio, N.;
Pankow, D.;
Peoples, J.;
Perlmutter, S.;
Prieto, E.;
Rabinowitz, D.;
Refregier, A.;
Rhodes, J.;
Roe, N.;
Rusin, D.;
Scarpine, V.;
Schubnell, M.;
Sholl, M.;
Smadja, G.;
Smith, R. M.;
Smoot, G.;
Snyder, J.;
Spadafora, A.;
Stebbins, A.;
Stoughton, C.;
Szymkowiak, A.;
Tarle, G.;
Taylor, K.;
Tilquin, A.;
Tomasch, A.;
Tucker, D.;
Vincent, D.;
von der Lippe, H.;
Walder, J-P.;
Wang, G.;
Wester, W.
Submitted: 2004-05-12
The Supernova / Acceleration Probe (SNAP) is a proposed space-based
experiment designed to study the dark energy and alternative explanations of
the acceleration of the Universe's expansion by performing a series of
complementary systematics-controlled measurements. We describe a
self-consistent reference mission design for building a Type Ia supernova
Hubble diagram and for performing a wide-area weak gravitational lensing study.
A 2-m wide-field telescope feeds a focal plane consisting of a 0.7
square-degree imager tiled with equal areas of optical CCDs and near infrared
sensors, and a high-efficiency low-resolution integral field spectrograph. The
SNAP mission will obtain high-signal-to-noise calibrated light-curves and
spectra for several thousand supernovae at redshifts between z=0.1 and 1.7. A
wide-field survey covering one thousand square degrees resolves ~100 galaxies
per square arcminute. If we assume we live in a cosmological-constant-dominated
Universe, the matter density, dark energy density, and flatness of space can
all be measured with SNAP supernova and weak-lensing measurements to a
systematics-limited accuracy of 1%. For a flat universe, the
density-to-pressure ratio of dark energy can be similarly measured to 5% for
the present value w0 and ~0.1 for the time variation w'. The large survey area,
depth, spatial resolution, time-sampling, and nine-band optical to NIR
photometry will support additional independent and/or complementary dark-energy
measurement approaches as well as a broad range of auxiliary science programs.
(Abridged)