sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Loose, A.

Normalized to: Loose, A.

4 article(s) in total. 86 co-authors, from 1 to 2 common article(s). Median position in authors list is 8,5.

[1]  oai:arXiv.org:1605.06291  [pdf] - 1426417
Dust Impact Monitor (SESAME-DIM) on board Rosetta/Philae: Millimetric particle flux at comet 67P/Churyumov-Gerasimenko
Comments: 5 figures, 3 tables
Submitted: 2016-05-20
The Philae lander of the Rosetta mission, aimed at the in situ investigation of comet 67P/C-G, was deployed to the surface of the comet nucleus on 12 Nov 2014 at 2.99 AU heliocentric distance. The Dust Impact Monitor (DIM) as part of the Surface Electric Sounding and Acoustic Monitoring Experiment (SESAME) on the lander employed piezoelectric detectors to detect the submillimetre- and millimetre-sized dust and ice particles emitted from the nucleus. We determine the upper limit of the ambient flux of particles in the measurement range of DIM based on the measurements performed with the instrument during Philae's descent to its nominal landing site Agilkia at distances of about 22 km, 18 km, and 5 km from the nucleus barycentre and at the final landing site Abydos. The geometric factor of the DIM sensor is calculated assuming an isotropic ambient flux of the submillimetre- and millimetre-sized particles. For the measurement intervals when no particles were detected the maximum true impact rate was calculated by assuming Poisson distribution of the impacts, and it was given as the detection limit at a 95% confidence level. Based on measurements performed with DIM, the upper limit of the flux of particles in the measurement range of the instrument was of the order of $10^{-8}-10^{-7}m^{-2}s^{-1}sr^{-1}$ during descent and $1.6\cdot10^{-9}m^{-2}s^{-1}sr^{-1}$ at Abydos on 13 and 14 Nov 2014. Considering particle speeds below escape velocity, the upper limit for the volume density of particles in the measurement range of DIM was constrained to $10^{-11}m^{-3}-10^{-12}m^{-3}$. Results of the calculations performed with the GIPSI tool on the expected particle fluxes during the descent of Philae were compatible with the non-detection of compact particles by the DIM instrument.
[2]  oai:arXiv.org:1510.01563  [pdf] - 1304198
Dust Impact Monitor (SESAME-DIM) Measurements at Comet 67P/Churyumov-Gerasimenko
Comments: 17 pages, 5 Tables, 9 Figures, in press, Astronomy & Astrophysics 2015
Submitted: 2015-10-06
The Rosetta lander Philae successfully landed on the nucleus of comet 67P/Churyumov-Gerasimenko on 12 November 2014. Philae carries the Dust Impact Monitor (DIM) on board, which is part of the Surface Electric Sounding and Acoustic Monitoring Experiment (SESAME). DIM employs piezoelectric PZT sensors to detect impacts by sub-millimeter and millimeter-sized ice and dust particles that are emitted from the nucleus and transported into the cometary coma. The DIM sensor measures dynamical data like flux and the directionality of the impacting particles. Mass and speed of the particles can be constrained assuming density and elastic particle properties. DIM was operated during three mission phases of Philae at the comet: (1) Before Philae's separation from Rosetta at distances of about 9.6 km, 11.8 km, and 25.3 km from the nucleus barycenter. In this mission phase particles released from the nucleus on radial trajectories remained undetectable because of significant obscuration by the structures of Rosetta, and no dust particles were indeed detected. (2) During Philae's descent to its nominal landing site Agilkia, DIM detected one approximately millimeter-sized particle at a distance of 5.0 km from the nucleus' barycenter, corresponding to an altitude of 2.4 km from the surface. This is the closest ever dust detection at a cometary nucleus by a dedicated in-situ dust detector. (3) At Philae's final landing site, Abydos, DIM detected no dust impact which may be due to low cometary activity in the vicinity of Philae, or due to shading by obstacles close to Philae, or both. Laboratory calibration experiments showed that the material properties of the detected particle are compatible with a porous particle having a bulk density of approximately $250\, \mathrm{kg\,m^{-3}}$. The particle could have been lifted off from the comet's surface by sublimating water ice.
[3]  oai:arXiv.org:1305.6510  [pdf] - 725098
An atom trap trace analysis system for measuring krypton contamination in xenon dark matter detectors
Comments: 6 pages, 5 figures
Submitted: 2013-05-28, last modified: 2013-09-27
We have developed an atom trap trace analysis (ATTA) system to measure Kr in Xe at the part per trillion (ppt) level, a prerequisite for the sensitivity achievable with liquid xenon dark matter detectors beyond the current generation. Since Ar and Kr have similar laser cooling wavelengths, the apparatus has been tested with Ar to avoid contamination prior to measuring Xe samples. A radio-frequency (RF) plasma discharge generates a beam of metastable atoms which is optically collimated, slowed, and trapped using standard magneto-optical techniques. Based on the measured overall system efficiency of $1.2 \times 10^{-8}$ (detection mode) we expect the ATTA system to reach the design goal sensitivity to ppt concentrations of Kr in Xe in $<2$ hours.
[4]  oai:arXiv.org:1007.4226  [pdf] - 1033885
The distribution of water in the high-mass star-forming region NGC 6334I
Comments: 7 pages, 3 figures, accepted by A&A
Submitted: 2010-07-23
We present observations of twelve rotational transitions of H2O-16, H2O-18, and H2O-17 toward the massive star-forming region NGC 6334 I, carried out with Herschel/HIFI as part of the guaranteed time key program Chemical HErschel Surveys of Star forming regions (CHESS). We analyze these observations to obtain insights into physical processes in this region. We identify three main gas components (hot core, cold foreground, and outflow) in NGC 6334 I and derive the physical conditions in these components. The hot core, identified by the emission in highly excited lines, shows a high excitation temperature of 200 K, whereas water in the foreground component is predominantly in the ortho- and para- ground states. The abundance of water varies between 4 10^-5 (outflow) and 10^-8 (cold foreground gas). This variation is most likely due to the freeze-out of water molecules onto dust grains. The H2O-18/H2O-17 abundance ratio is 3.2, which is consistent with the O-18/O-17 ratio determined from CO isotopologues. The ortho/para ratio in water appears to be relatively low 1.6(1) in the cold, quiescent gas, but close to the equilibrium value of three in the warmer outflow material (2.5(0.8)).