sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Longval, Y.

Normalized to: Longval, Y.

6 article(s) in total. 257 co-authors, from 1 to 4 common article(s). Median position in authors list is 17,5.

[1]  oai:arXiv.org:1901.06196  [pdf] - 1971175
The geometry of the magnetic field in the Central Molecular Zone measured by PILOT
Comments: 17 pages, 14 figures, submitted to A&A
Submitted: 2019-01-18
We present the first far infrared (FIR) dust emission polarization map covering the full extent Milky Way's Central molecular zone (CMZ). The data, obtained with the PILOT balloon-borne experiment, covers the Galactic Center region $-2\,^\circ<l<2\,^\circ$, $-4\,^\circ<b<3\,^\circ$ at a wavelength of 240 $\mu$m and an angular resolution $2.2\,'$. From our measured dust polarization angles, we infer a magnetic field orientation projected onto the plane of the sky that is remarkably ordered over the full extent of the CMZ, with an average tilt angle of $\simeq 22\,^\circ$ clockwise with respect to the Galactic plane. Our results confirm previous claims that the field traced by dust polarized emission is oriented nearly orthogonal to the field traced by GHz radio synchrotron emission in the Galactic Center region. The observed field structure is globally compatible with the latest Planck polarization data at 353 GHz and 217 GHz. Upon subtraction of the extended emission in our data, the mean field orientation that we obtain shows good agreement with the mean field orientation measured at higher angular resolution by the JCMT within the 20 km/s and 50 km/s molecular clouds. We find no evidence that the magnetic field orientation is related to the 100 pc twisted ring structure within the CMZ. We propose that the low polarization fraction in the Galactic Center region and the highly ordered projected field orientation can be reconciled if the field is strong, with a 3D geometry that is is mostly oriented $\simeq 15\,^\circ$ with respect to the line-of-sight towards the Galactic center. Assuming equipartition between the magnetic pressure and ram pressure, we obtain magnetic field strengths estimates as high as a few mG for several CMZ molecular clouds.
[2]  oai:arXiv.org:1804.05645  [pdf] - 1810141
PILOT balloon-borne experiment in-flight performance
Comments:
Submitted: 2018-04-16, last modified: 2019-01-07
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Australia in april 2017. In this paper, we present the inflight performance of the instrument during these two flights. We concentrate on performances during flight#2, but allude to flight#1 performances if significantly different. We first present a short description of the instrument and the flights. We determine the time constants of our detectors combining inflight information from the signal decay following high energy particle impacts (glitches) and of our internal calibration source. We use these time constants to deconvolve the data timelines and analyse the optical quality of the instrument as measured on planets. We then analyse the structure and polarization of the instrumental background. We measure the detector response flat field and its time variations using the signal from the residual atmosphere and of our internal calibration source. Finally, we analyze the detector noise spectral and temporal properties. The in-flight performances are found to be satisfactory and globally in line with expectations from ground calibrations. We conclude by assessing the expected in-flight sensitivity of the instrument in light of the above in-flight performances.
[3]  oai:arXiv.org:1508.02488  [pdf] - 1260877
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
Comments: 29 pages, 9 figures
Submitted: 2015-08-11
In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and mechanical design. We show that the test data, as measured during the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton Laboratory, and at the NASA Goddard Space Flight Center, indicate that the instrument complies with its design requirements and goals. We also discuss the operational requirements (multiple dithers and exposures) needed for optimal scientific utilization of the MIRIM.
[4]  oai:arXiv.org:1410.5760  [pdf] - 885266
PILOT: a balloon-borne experiment to measure the polarized FIR emission of dust grains in the interstellar medium
Comments: 17 pages, 13 figures. Presented at SPIE, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII. To be published in Proc. SPIE volume 9153
Submitted: 2014-10-13
Future cosmology space missions will concentrate on measuring the polarization of the Cosmic Microwave Background, which potentially carries invaluable information about the earliest phases of the evolution of our universe. Such ambitious projects will ultimately be limited by the sensitivity of the instrument and by the accuracy at which polarized foreground emission from our own Galaxy can be subtracted out. We present the PILOT balloon project which will aim at characterizing one of these foreground sources, the polarization of the dust continuum emission in the diffuse interstellar medium. The PILOT experiment will also constitute a test-bed for using multiplexed bolometer arrays for polarization measurements. We present the results of ground tests obtained just before the first flight of the instrument.
[5]  oai:arXiv.org:1101.2039  [pdf] - 1051324
Planck early results: first assessment of the High Frequency Instrument in-flight performance
Planck HFI Core Team; Ade, P. A. R.; Aghanim, N.; Ansari, R.; Arnaud, M.; Ashdown, M.; Aumont, J.; Banday, A. J.; Bartelmann, M.; Bartlett, J. G.; Battaner, E.; Benabed, K.; Benot, A.; Bernard, J. -P.; Bersanelli, M.; Bhatia, R.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Boulanger, F.; Bradshaw, T.; Brelle, E.; Bucher, M.; Camus, P.; Cardoso, J. -F.; Catalano, A.; Challinor, A.; Chamballu, A.; Charra, J.; Charra, M.; Chary, R. -R.; Chiang, C.; Church, S.; Clements, D. L.; Colombi, S.; Couchot, F.; Coulais, A.; Cressiot, C.; Crill, B. P.; Crook, M.; de Bernardis, P.; Delabrouille, J.; Delouis, J. -M.; Désert, F. -X.; Dolag, K.; Dole, H.; Doré, O.; Douspis, M.; Efstathiou, G.; Eng, P.; Filliard, C.; Forni, O.; Fosalba, P.; Fourmond, J. -J.; Ganga, K.; Giard, M.; Girard, D.; Giraud-Héraud, Y.; Gispert, R.; Gorski, K. M.; Gratton, S.; Griffin, M.; Guyot, G.; Haissinski, J.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Hernandez-Monteagudo, C.; Hildebrandt, S. R.; Hills, R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Huenberger, K. M.; Jae, A. H.; Jones, W. C.; Kaplan, J.; Kneissl, R.; Knox, L.; Lagache, G.; Lamarre, J. -M.; Lami, P.; Lange, A. E.; Lasenby, A.; Lavabre, A.; Lawrence, C. R.; Leriche, B.; Leroy, C.; Longval, Y.; Macas-Perez, J. F.; Maciaszek, T.; MacTavish, C. J.; Maei, B.; Mandolesi, N.; Mann, R.; Mansoux, B.; Masi, S.; Matsumura, T.; McGehee, P.; Melin, J. -B.; Mercier, C.; Miville-Deschnes, M. -A.; Moneti, A.; Montier, L.; Mortlock, D.; Murphy, A.; Nati, F.; Nettereld, C. B.; Norgaard-Nielsen, H. U.; North, C.; Noviello, F.; Novikov, D.; Osborne, S.; Paine, C.; Pajot, F.; Patanchon, G.; Peacocke, T.; Pearson, T. J.; Perdereau, O.; Perotto, L.; Piacentini, F.; Piat, M.; Plaszczynski, S.; Pointecouteau, E.; Pons, R.; Ponthieu, N.; Prezeau, G.; Prunet, S.; Puget, J. -L.; Reach, W. T.; Renault, C.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Santos, D.; Savini, G.; Schaefer, B. M.; Shellard, P.; Spencer, L.; Starck, J. -L.; Stassi, P.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sygnet, J. -F.; Tauber, J. A.; Thum, C.; Torre, J. -P.; Touze, F.; Tristram, M.; Van Leeuwen, F.; Vibert, L.; Vibert, D.; Wade, L. A.; Wandelt, B. D.; White, S. D. M.; Wiesemeyer, H.; Woodcraft, A.; Yurchenko, V.; Yvon, D.; Zacchei, A.
Comments: Submitted to A&A. 22 pages, 6 tables, 21 figures. One of a set of simultaneous papers for the Planck Mission
Submitted: 2011-01-11
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during ground testing. Observations of Mars, Jupiter, and Saturn verified both the optical system and the time response of the detection chains. The optical beams are close to predictions from physical optics modeling. The time response of the detection chains is close to pre-launch measurements. The detectors suffer from an unexpected high flux of cosmic rays related to low solar activity. Due to the redundancy of Planck's observations strategy, the removal of a few percent of data contaminated by glitches does not affect significantly the sensitivity. The cosmic rays heat up significantly the bolometer plate and the modulation on periods of days to months of the heat load creates a common drift of all bolometer signals which do not affect the scientific capabilities. Only the high energy cosmic rays showers induce inhomogeneous heating which is a probable source of low frequency noise.
[6]  oai:arXiv.org:1006.5735  [pdf] - 1033405
Optical performance of the JWST MIRI flight model: characterization of the point spread function at high-resolution
Comments: 13 pages, submitted to SPIE Proceedings vol. 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wave
Submitted: 2010-06-29
The Mid Infra Red Instrument (MIRI) is one of the four instruments onboard the James Webb Space Telescope (JWST), providing imaging, coronagraphy and spectroscopy over the 5-28 microns band. To verify the optical performance of the instrument, extensive tests were performed at CEA on the flight model (FM) of the Mid-InfraRed IMager (MIRIM) at cryogenic temperatures and in the infrared. This paper reports on the point spread function (PSF) measurements at 5.6 microns, the shortest operating wavelength for imaging. At 5.6 microns the PSF is not Nyquist-sampled, so we use am original technique that combines a microscanning measurement strategy with a deconvolution algorithm to obtain an over-resolved MIRIM PSF. The microscanning consists in a sub-pixel scan of a point source on the focal plane. A data inversion method is used to reconstruct PSF images that are over-resolved by a factor of 7 compared to the native resolution of MIRI. We show that the FWHM of the high-resolution PSFs were 5-10% wider than that obtained with Zemax simulations. The main cause was identified as an out-of-specification tilt of the M4 mirror. After correction, two additional test campaigns were carried out, and we show that the shape of the PSF is conform to expectations. The FWHM of the PSFs are 0.18-0.20 arcsec, in agreement with simulations. 56.1-59.2% of the total encircled energy (normalized to a 5 arcsec radius) is contained within the first dark Airy ring, over the whole field of view. At longer wavelengths (7.7-25.5 microns), this percentage is 57-68%. MIRIM is thus compliant with the optical quality requirements. This characterization of the MIRIM PSF, as well as the deconvolution method presented here, are of particular importance, not only for the verification of the optical quality and the MIRI calibration, but also for scientific applications.