sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Loidl, M.

Normalized to: Loidl, M.

8 article(s) in total. 44 co-authors, from 1 to 8 common article(s). Median position in authors list is 21,5.

[1]  oai:arXiv.org:astro-ph/0310657  [pdf] - 60320
Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium Detectors for Dark Matter Search
Comments: 27 pages, Latex, 11 figures. Submitted to NIM A
Submitted: 2003-10-22
Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.
[2]  oai:arXiv.org:astro-ph/0207308  [pdf] - 50451
Experimental Particle Dark Matter Search
Comments: 9 pages, 4 figures, to appear in Proceedings of the XXXVIIth Rencontres de Moriond
Submitted: 2002-07-15, last modified: 2002-07-22
Several aspects of the motivation for particle dark matter search are introduced. The experimental principles and present state of the most important experiments are presented. Direct searches for WIMPs are explained in some detail, indirect WIPM searches and axion searches are presented more briefly.
[3]  oai:arXiv.org:astro-ph/0206271  [pdf] - 49902
Improved Exclusion Limits from the EDELWEISS WIMP Search
Comments: 14 pages, Latex, 5 figures. Submitted to Phys. Lett. B
Submitted: 2002-06-17
The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exposure of 7.4 kg.days. This result is combined with the previous EDELWEISS data to derive a limit on the cross-section for spin-independent interaction of WIMPs and nucleons as a function of WIMP mass, using standard nuclear physics and astrophysical assumptions. This limit excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first sample of supersymmetric models are also excluded at 90%CL.
[4]  oai:arXiv.org:astro-ph/0205023  [pdf] - 49097
320g Ionization-Heat Cryogenic Detector for Dark Matter Search in the EDELWEISS Experiment
Comments: 4 pages, 3 figures
Submitted: 2002-05-02
The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more than 4 times the mass of previous detectors. Calibrations of this detector are used to determine its energy resolution and fiducial volume, and to optimize the detector design for the 1kg phase of the EDELWEISS-I experiment. Analysis of the calibrations and characteristics of a first series of 320g-detectors are presented.
[5]  oai:arXiv.org:astro-ph/0106094  [pdf] - 173739
First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector
Comments: 14 pages, Latex, 4 figures. Submitted to Phys. Lett. B
Submitted: 2001-06-06
The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-independent interaction of WIMPs and nucleons are set in the framework of the Minimal Supersymmetric Standard Model (MSSM). The central value of the signal reported by the experiment DAMA is excluded at 90% CL.
[6]  oai:arXiv.org:astro-ph/0104192  [pdf] - 1943551
Dark Matter Search in the EDELWEISS experiment
Comments: 4 pages, LaTeX, 3 figures, contribution to " Very High Energy Phenomena in the Universe ", Les Arcs, France (January 20-27, 2001)
Submitted: 2001-04-11
The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g bolometers are described. After a few weeks of data taking, data accumulated with one of these detectors already allow to reach the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.
[7]  oai:arXiv.org:astro-ph/0101204  [pdf] - 1507854
Dark Matter Search in the Edelweiss Experiment
Comments: IDM 2000, 3rd International Workshop on the Identification of Dark Matter, York (GB), 18-22/09/2000, v2.0 minor modifications
Submitted: 2001-01-12, last modified: 2001-02-23
Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.
[8]  oai:arXiv.org:astro-ph/0101454  [pdf] - 40592
The EDELWEISS Experiment : Status and Outlook
Comments: International Conference on Dark Matter in Astro and Particle Physics (Dark 2000), Heidelberg, Germany, 10-16 Jul 2000, v3 minor revisions
Submitted: 2001-01-25, last modified: 2001-02-06
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.