Normalized to: Loehmannsroeben, H.
[1]
oai:arXiv.org:1212.1201 [pdf] - 650886
GNOSIS: the first instrument to use fibre Bragg gratings for OH
suppression
Trinh, Christopher Q.;
Ellis, Simon C.;
Bland-Hawthorn, Joss;
Lawrence, Jon S.;
Horton, Anthony J.;
Leon-Saval, Sergio G.;
Shortridge, Keith;
Bryant, Julia;
Case, Scott;
Colless, Matthew;
Couch, Warick;
Freeman, Kenneth;
Loehmannsroeben, Hans-Gerd;
Gers, Luke;
Glazebrook, Karl;
Haynes, Roger;
Lee, Steve;
O'Byrne, John;
Miziarski, Stan;
Roth, Martin M.;
Schmidt, Brian;
Tinney, Christopher G.;
Zheng, Jessica
Submitted: 2012-12-05, last modified: 2013-04-11
GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression
fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the
103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS
was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2
spectrograph to demonstrate the potential of OH suppression fibres, but may be
potentially used with any telescope and spectrograph combination. Unlike
previous atmospheric suppression techniques GNOSIS suppresses the lines before
dispersion and in a manner that depends purely on wavelength. We present the
instrument design and report the results of laboratory and on-sky tests from
commissioning. While these tests demonstrated high throughput and excellent
suppression of the skylines by the OH suppression fibres, surprisingly GNOSIS
produced no significant reduction in the interline background and the
sensitivity of GNOSIS and IRIS2 is about the same as IRIS2. It is unclear
whether the lack of reduction in the interline background is due to physical
sources or systematic errors as the observations are detector noise-dominated.
OH suppression fibres could potentially impact ground-based astronomy at the
level of adaptive optics or greater. However, until a clear reduction in the
interline background and the corresponding increasing in sensitivity is
demonstrated optimized OH suppression fibres paired with a fibre-fed
spectrograph will at least provide a real benefits at low resolving powers.
[2]
oai:arXiv.org:1206.6551 [pdf] - 1124455
Suppression of the near-infrared OH night sky lines with fibre Bragg
gratings - first results
Ellis, S. C.;
Bland-Hawthorn, J.;
Lawrence, J.;
Horton, A. J.;
Trinh, C.;
Leon-Saval, S. G.;
Shortridge, K.;
Bryant, J.;
Case, S.;
Colless, M.;
Couch, W.;
Freeman, K.;
Gers, L.;
Glazebrook, K.;
Haynes, R.;
Lee, S.;
Loehmannsroeben, H. -G.;
Byrne, J. O.;
Miziarski, S.;
Roth, M.;
Schmidt, B.;
Tinney, C. G.;
Zheng, J.
Submitted: 2012-06-27
The background noise between 1 and 1.8 microns in ground-based instruments is
dominated by atmospheric emission from hydroxyl molecules. We have built and
commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between
1.47 - 1.7 microns by a factor of ~1000 with a resolving power of ~10,000. We
present the first results from the commissioning of GNOSIS using the IRIS2
spectrograph at the AAT. The combined throughput of the GNOSIS fore-optics,
grating unit and relay optics is ~36 per cent, but this could be improved to
~46 per cent with a more optimal design. We measure strong suppression of the
OH lines, confirming that OH suppression with fibre Bragg gratings will be a
powerful technology for low resolution spectroscopy. The integrated OH
suppressed background between 1.5 and 1.7 microns is reduced by a factor of 9
compared to a control spectrum using the same system without suppression. The
potential of low resolution OH suppressed spectroscopy is illustrated with
example observations.
The GNOSIS background is dominated by detector dark current below 1.67
microns and by thermal emission above 1.67 microns. After subtracting these we
detect an unidentified residual interline component of ~ 860 +/ 210
ph/s/m^2/micron/arcsec^2. This component is equally bright in the suppressed
and control spectra. We have investigated the possible source of the interline
component, but were unable to discriminate between a possible instrumental
artifact and intrinsic atmospheric emission. Resolving the source of this
emission is crucial for the design of fully optimised OH suppression
spectrographs. The next generation OH suppression spectrograph will be focussed
on resolving the source of the interline component, taking advantage of better
optimisation for a FBG feed. We quantify the necessary improvements for an
optimal OH suppressing fibre spectrograph design.