sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Loaiza, P.

Normalized to: Loaiza, P.

8 article(s) in total. 170 co-authors, from 1 to 7 common article(s). Median position in authors list is 32,0.

[1]  oai:arXiv.org:1412.0161  [pdf] - 904473
Background optimization for a new spherical gas detector for very light WIMP detection
Comments: 5 pages, 3 figures
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very low energy threshold independent of the volume (due to its very low capacitance), a good energy resolution, robustness and a single detection readout channel, in its simplest version. Applications range from radon emanation gas monitoring, neutron flux and gamma counting and spectroscopy to dark matter searches, in particular low mass WIMPs and coherent neutrino scattering measure- ment. Laboratories interested in these various applications share expertise within the NEWS (New Experiments With Sphere) network. SEDINE, a low background prototype installed at underground site of Laboratoire Souterrain de Modane is currently being operated and aims at measuring events at very low energy threshold, around 100 eV. We will present the energy cali- bration with 37Ar, the surface background reduction, the measurement of detector background at sub-keV energies, and show anticipated sensitivities for light dark matter search.
[2]  oai:arXiv.org:1302.7112  [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
Comments: 21 pages, 16 figures, Accepted for publication in Astropart. Phys
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the determination of the angular dependent muon flux in LSM. The results are in good agreement with both MC simulations and earlier measurements. Synchronization of the muon-veto system with the phonon and ionization signals of the Ge detector array allowed identification of muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm 0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} = 0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After vetoing, the remaining rate of accepted muon-induced neutrons in the EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on these results, the muon-induced background expectation for an anticipated exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$ events.
[3]  oai:arXiv.org:1207.1815  [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
Comments: PRD rapid communication accepted
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.
[4]  oai:arXiv.org:1103.4070  [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
Comments: 23 pages, 5 figures; matches published version
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
[5]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[6]  oai:arXiv.org:1006.3098  [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark Matter searches
Comments: Accepted for publication in Astroparticle Physics; 14 pages, 10 figures
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.
[7]  oai:arXiv.org:0912.0805  [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
Comments: 14 pages, 3 figures. Submitted to Phys Lett. B
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.
[8]  oai:arXiv.org:astro-ph/0404311  [pdf] - 291309
First results with the ORPHEUS dark matter detector
Comments: 20 pages, Latex, submitted to Astropart. Phys
Submitted: 2004-04-15
The ORPHEUS dark matter detector is operating at our underground laboratory in Bern (70 m.w.e.). The detector relies on measuring the magnetic flux variation produced by weakly interacting massive particles (WIMPs) as they heat micron-sized superheated superconducting tin granules (SSG) and induce superconducting-to-normal phase transitions. In an initial phase, 0.45 kg of tin granules in a segmented detector volume have been used. In this paper a general description of the experimental set-up, overall performance of the detector, and first results are presented.