Normalized to: Loaiza, P.
[1]
oai:arXiv.org:1412.0161 [pdf] - 904473
Background optimization for a new spherical gas detector for very light
WIMP detection
Dastgheibi-Fard, Ali;
Giomataris, I.;
Gerbierb, G.;
Derree, J.;
Gros, M.;
Magnier, P.;
Jourde, D.;
Bougamont, E .;
Navick, X-F.;
Papaevangelou, T.;
Galan, J.;
Tsiledakis, G.;
Piquemal, F.;
Zampaolo, M.;
Loaiza, P.;
Savvidis, I.
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a
novel type of par- ticle detector, with a broad range of applications. Its main
features include a very low energy threshold independent of the volume (due to
its very low capacitance), a good energy resolution, robustness and a single
detection readout channel, in its simplest version. Applications range from
radon emanation gas monitoring, neutron flux and gamma counting and
spectroscopy to dark matter searches, in particular low mass WIMPs and coherent
neutrino scattering measure- ment. Laboratories interested in these various
applications share expertise within the NEWS (New Experiments With Sphere)
network. SEDINE, a low background prototype installed at underground site of
Laboratoire Souterrain de Modane is currently being operated and aims at
measuring events at very low energy threshold, around 100 eV. We will present
the energy cali- bration with 37Ar, the surface background reduction, the
measurement of detector background at sub-keV energies, and show anticipated
sensitivities for light dark matter search.
[2]
oai:arXiv.org:1302.7112 [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
The EDELWEISS collaboration;
Schmidt, B.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Collin, S.;
Coulter, P.;
Cox, G. A.;
Crauste, O.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Juillard, A.;
Kluck, H.;
Kozlov, V. Y.;
Kleifges, M.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nieder, H.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrentó-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark
matter search has been performed on a data set acquired in 2009 and 2010. The
total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was
measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The
modular design of the muon-veto system allows the reconstruction of the muon
trajectory and hence the determination of the angular dependent muon flux in
LSM. The results are in good agreement with both MC simulations and earlier
measurements. Synchronization of the muon-veto system with the phonon and
ionization signals of the Ge detector array allowed identification of
muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm
0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} =
0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After
vetoing, the remaining rate of accepted muon-induced neutrons in the
EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm
irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on
these results, the muon-induced background expectation for an anticipated
exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$
events.
[3]
oai:arXiv.org:1207.1815 [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization
detectors
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
Domange, J.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Heuermann, G.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrento-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear
recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium
detectors equipped with thermal sensors and an electrode design (ID) which
allows to efficiently reject several sources of background. The data indicate
no evidence for an exponential distribution of low-energy nuclear recoils that
could be attributed to WIMP elastic scattering after an exposure of 113 kg.d.
For WIMPs of mass 10 GeV, the observation of one event in the WIMP search
region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent
WIMP-nucleon scattering cross-section, which constrains the parameter space
associated with the findings reported by the CoGeNT, DAMA and CRESST
experiments.
[4]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[5]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[6]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[7]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[8]
oai:arXiv.org:astro-ph/0404311 [pdf] - 291309
First results with the ORPHEUS dark matter detector
Borer, K.;
Czapek, G.;
Hasenbalg, F.;
Hauser, M.;
Janos, S.;
Loaiza, P.;
Moser, U.;
Pretzl, K.;
Schutz, C.;
Wicht, P.;
Wuthrich, S.
Submitted: 2004-04-15
The ORPHEUS dark matter detector is operating at our underground laboratory
in Bern (70 m.w.e.). The detector relies on measuring the magnetic flux
variation produced by weakly interacting massive particles (WIMPs) as they heat
micron-sized superheated superconducting tin granules (SSG) and induce
superconducting-to-normal phase transitions. In an initial phase, 0.45 kg of
tin granules in a segmented detector volume have been used. In this paper a
general description of the experimental set-up, overall performance of the
detector, and first results are presented.