Normalized to: Lippincott, W.
[1]
oai:arXiv.org:1907.12509 [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon
interactions from IceCube and PICO
IceCube Collaboration;
Aartsen, M. G.;
Ackermann, M.;
Adams, J.;
Aguilar, J. A.;
Ahlers, M.;
Ahrens, M.;
Alispach, C.;
Andeen, K.;
Anderson, T.;
Ansseau, I.;
Anton, G.;
Argüelles, C.;
Auffenberg, J.;
Axani, S.;
Backes, P.;
Bagherpour, H.;
Bai, X.;
V., A. Balagopal;
Barbano, A.;
Barwick, S. W.;
Bastian, B.;
Baum, V.;
Baur, S.;
Bay, R.;
Beatty, J. J.;
Becker, K. -H.;
Tjus, J. Becker;
BenZvi, S.;
Berley, D.;
Bernardini, E.;
Besson, D. Z.;
Binder, G.;
Bindig, D.;
Blaufuss, E.;
Blot, S.;
Bohm, C.;
Börner, M.;
Böser, S.;
Botner, O.;
Böttcher, J.;
Bourbeau, E.;
Bourbeau, J.;
Bradascio, F.;
Braun, J.;
Bron, S.;
Brostean-Kaiser, J.;
Burgman, A.;
Buscher, J.;
Busse, R. S.;
Carver, T.;
Chen, C.;
Cheung, E.;
Chirkin, D.;
Choi, S.;
Classen, L.;
Coleman, A.;
Collin, G. H.;
Conrad, J. M.;
Coppin, P.;
Correa, P.;
Cowen, D. F.;
Cross, R.;
Dave, P.;
De Clercq, C.;
DeLaunay, J. J.;
Dembinski, H.;
Deoskar, K.;
De Ridder, S.;
Desiati, P.;
de Vries, K. D.;
de Wasseige, G.;
de With, M.;
DeYoung, T.;
Diaz, A.;
Díaz-Vélez, J. C.;
Dujmovic, H.;
Dunkman, M.;
Dvorak, E.;
Eberhardt, B.;
Ehrhardt, T.;
Eller, P.;
Engel, R.;
Evenson, P. A.;
Fahey, S.;
Fazely, A. R.;
Felde, J.;
Filimonov, K.;
Finley, C.;
Franckowiak, A.;
Friedman, E.;
Fritz, A.;
Gaisser, T. K.;
Gallagher, J.;
Ganster, E.;
Garrappa, S.;
Gerhardt, L.;
Ghorbani, K.;
Glauch, T.;
Glüsenkamp, T.;
Goldschmidt, A.;
Gonzalez, J. G.;
Grant, D.;
Griffith, Z.;
Griswold, S.;
Günder, M.;
Gündüz, M.;
Haack, C.;
Hallgren, A.;
Halve, L.;
Halzen, F.;
Hanson, K.;
Haungs, A.;
Hebecker, D.;
Heereman, D.;
Heix, P.;
Helbing, K.;
Hellauer, R.;
Henningsen, F.;
Hickford, S.;
Hignight, J.;
Hill, G. C.;
Hoffman, K. D.;
Hoffmann, R.;
Hoinka, T.;
Hokanson-Fasig, B.;
Hoshina, K.;
Huang, F.;
Huber, M.;
Huber, T.;
Hultqvist, K.;
Hünnefeld, M.;
Hussain, R.;
In, S.;
Iovine, N.;
Ishihara, A.;
Japaridze, G. S.;
Jeong, M.;
Jero, K.;
Jones, B. J. P.;
Jonske, F.;
Joppe, R.;
Kang, D.;
Kang, W.;
Kappes, A.;
Kappesser, D.;
Karg, T.;
Karl, M.;
Karle, A.;
Katz, U.;
Kauer, M.;
Kelley, J. L.;
Kheirandish, A.;
Kim, J.;
Kintscher, T.;
Kiryluk, J.;
Kittler, T.;
Klein, S. R.;
Koirala, R.;
Kolanoski, H.;
Köpke, L.;
Kopper, C.;
Kopper, S.;
Koskinen, D. J.;
Kowalski, M.;
Krings, K.;
Krückl, G.;
Kulacz, N.;
Kurahashi, N.;
Kyriacou, A.;
Labare, M.;
Lanfranchi, J. L.;
Larson, M. J.;
Lauber, F.;
Lazar, J. P.;
Leonard, K.;
Leszczyńska, A.;
Leuermann, M.;
Liu, Q. R.;
Lohfink, E.;
Mariscal, C. J. Lozano;
Lu, L.;
Lucarelli, F.;
Lünemann, J.;
Luszczak, W.;
Lyu, Y.;
Ma, W. Y.;
Madsen, J.;
Maggi, G.;
Mahn, K. B. M.;
Makino, Y.;
Mallik, P.;
Mallot, K.;
Mancina, S.;
Mariş, I. C.;
Maruyama, R.;
Mase, K.;
Maunu, R.;
McNally, F.;
Meagher, K.;
Medici, M.;
Medina, A.;
Meier, M.;
Meighen-Berger, S.;
Menne, T.;
Merino, G.;
Meures, T.;
Micallef, J.;
Mockler, D.;
Momenté, G.;
Montaruli, T.;
Moore, R. W.;
Morse, R.;
Moulai, M.;
Muth, P.;
Nagai, R.;
Naumann, U.;
Neer, G.;
Niederhausen, H.;
Nowicki, S. C.;
Nygren, D. R.;
Pollmann, A. Obertacke;
Oehler, M.;
Olivas, A.;
O'Murchadha, A.;
O'Sullivan, E.;
Palczewski, T.;
Pandya, H.;
Pankova, D. V.;
Park, N.;
Peiffer, P.;
Heros, C. Pérez de los;
Philippen, S.;
Pieloth, D.;
Pinat, E.;
Pizzuto, A.;
Plum, M.;
Porcelli, A.;
Price, P. B.;
Przybylski, G. T.;
Raab, C.;
Raissi, A.;
Rameez, M.;
Rauch, L.;
Rawlins, K.;
Rea, I. C.;
Reimann, R.;
Relethford, B.;
Renschler, M.;
Renzi, G.;
Resconi, E.;
Rhode, W.;
Richman, M.;
Robertson, S.;
Rongen, M.;
Rott, C.;
Ruhe, T.;
Ryckbosch, D.;
Rysewyk, D.;
Safa, I.;
Herrera, S. E. Sanchez;
Sandrock, A.;
Sandroos, J.;
Santander, M.;
Sarkar, S.;
Sarkar, S.;
Satalecka, K.;
Schaufel, M.;
Schieler, H.;
Schlunder, P.;
Schmidt, T.;
Schneider, A.;
Schneider, J.;
Schröder, F. G.;
Schumacher, L.;
Sclafani, S.;
Seckel, D.;
Seunarine, S.;
Shefali, S.;
Silva, M.;
Snihur, R.;
Soedingrekso, J.;
Soldin, D.;
Song, M.;
Spiczak, G. M.;
Spiering, C.;
Stachurska, J.;
Stamatikos, M.;
Stanev, T.;
Stein, R.;
Steinmüller, P.;
Stettner, J.;
Steuer, A.;
Stezelberger, T.;
Stokstad, R. G.;
Stößl, A.;
Strotjohann, N. L.;
Stürwald, T.;
Stuttard, T.;
Sullivan, G. W.;
Taboada, I.;
Tenholt, F.;
Ter-Antonyan, S.;
Terliuk, A.;
Tilav, S.;
Tomankova, L.;
Tönnis, C.;
Toscano, S.;
Tosi, D.;
Trettin, A.;
Tselengidou, M.;
Tung, C. F.;
Turcati, A.;
Turcotte, R.;
Turley, C. F.;
Ty, B.;
Unger, E.;
Elorrieta, M. A. Unland;
Usner, M.;
Vandenbroucke, J.;
Van Driessche, W.;
van Eijk, D.;
van Eijndhoven, N.;
Vanheule, S.;
van Santen, J.;
Vraeghe, M.;
Walck, C.;
Wallace, A.;
Wallraff, M.;
Wandkowsky, N.;
Watson, T. B.;
Weaver, C.;
Weindl, A.;
Weiss, M. J.;
Weldert, J.;
Wendt, C.;
Werthebach, J.;
Whelan, B. J.;
Whitehorn, N.;
Wiebe, K.;
Wiebusch, C. H.;
Wille, L.;
Williams, D. R.;
Wills, L.;
Wolf, M.;
Wood, J.;
Wood, T. R.;
Woschnagg, K.;
Wrede, G.;
Xu, D. L.;
Xu, X. W.;
Xu, Y.;
Yanez, J. P.;
Yodh, G.;
Yoshida, S.;
Yuan, T.;
Collaboration, M. Zöcklein. PICO;
:;
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity
distribution for dark matter (DM) particles in the Galaxy, the most stringent
current constraints on their spin-dependent scattering cross-section with
nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$
superheated bubble chamber experiments. The former is sensitive to high energy
neutrinos from the self-annihilation of DM particles captured in the Sun, while
the latter looks for nuclear recoil events from DM scattering off nucleons.
Although slower DM particles are more likely to be captured by the Sun, the
faster ones are more likely to be detected by PICO. Recent N-body simulations
suggest significant deviations from the SHM for the smooth halo component of
the DM, while observations hint at a dominant fraction of the local DM being in
substructures. We use the method of Ferrer et al. (2015) to exploit the
complementarity between the two approaches and derive conservative constraints
on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim
3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at
$\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+
\tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{
GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are
independent of the DM velocity distribution.
[2]
oai:arXiv.org:1802.06039 [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.;
Akerlof, C. W.;
Alsum, S. K.;
Araújo, H. M.;
Arthurs, M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Bauer, D.;
Belle, J.;
Beltrame, P.;
Benson, T.;
Bernard, E. P.;
Biesiadzinski, T. P.;
Boast, K. E.;
Boxer, B.;
Brás, P.;
Buckley, J. H.;
Bugaev, V. V.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Chan, C.;
Cherwinka, J. J.;
Cole, A.;
Cottle, A.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
Dahl, C. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, W. R.;
Fan, A.;
Fayer, S.;
Fiorucci, S.;
Fruth, T.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
van der Grinten, M. G. D.;
Hall, C. R.;
Hans, S.;
Hanzel, K.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hillbrand, S.;
Hjemfelt, C.;
Hoff, M. D.;
Hor, J. Y-K.;
Huang, D. Q.;
Ignarra, C. M.;
Ji, W.;
Kaboth, A. C.;
Kamdin, K.;
Keefner, J.;
Khaitan, D.;
Khazov, A.;
Kim, Y. D.;
Kocher, C. D.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kreczko, L.;
Krikler, B.;
Kudryavtsev, V. A.;
Kyre, S.;
Lee, J.;
Lenardo, B. G.;
Leonard, D. S.;
Lesko, K. T.;
Levy, C.;
Li, J.;
Liao, J.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Linehan, R.;
Lippincott, W. H.;
Liu, X.;
Lopes, M. I.;
Paredes, B. López;
Lorenzon, W.;
Luitz, S.;
Lyle, J. M.;
Majewski, P.;
Manalaysay, A.;
Mannino, R. L.;
Maupin, C.;
McKinsey, D. N.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Morrison, E.;
Mount, B. J.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikoleyczik, J.;
O'Sullivan, K.;
Olcina, I.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Patton, S. J.;
Pease, E. K.;
Penning, B.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Rhyne, C. A.;
Richards, A.;
Rodrigues, J. P.;
Rosero, R.;
Rossiter, P.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silk, J. J.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stancu, I.;
Stark, M. R.;
Stiegler, T. M.;
Stifter, K.;
Szydagis, M.;
Taylor, W. C.;
Taylor, R.;
Taylor, D. J.;
Temples, D.;
Terman, P. A.;
Thomas, K. J.;
Timalsina, M.;
To, W. H.;
Tomás, A.;
Tope, T. E.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Utku, U.;
Va'vra, J.;
Vacheret, A.;
Verbus, J. R.;
Voirin, E.;
Waldron, W. L.;
Watson, J. R.;
Webb, R. C.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, I.
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well
underway, LZ is on track for commissioning at SURF in 2020.
[3]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[5]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.
[6]
oai:arXiv.org:1702.07666 [pdf] - 1581621
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Campion, P.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Olson, S.;
Ortega, A.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Roeder, A.;
Rucinski, R.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2017-02-24, last modified: 2017-08-02
New results are reported from the operation of the PICO-60 dark matter
detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the
SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60
C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and
the observed multiple-scattering neutron rate indicates a single-scatter
neutron background of less than 1 event per month. A blind analysis of an
efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold
reveals no single-scattering nuclear recoil candidates, consistent with the
predicted background. These results set the most stringent direct-detection
constraint to date on the WIMP-proton spin-dependent cross section at 3.4
$\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one
order of magnitude improvement from previous PICO results.
[8]
oai:arXiv.org:0904.2930 [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape
discrimination of low-energy beta and nuclear recoils in liquid argon with
DEAP-1
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boudjemline, K.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
Duncan, F.;
Fatemighomi, N.;
Ford, R.;
Gagnon, R.;
Giampa, P.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Hearns, C.;
Hofgartner, J.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
La Zia, F.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Mehdiyev, R.;
McKinsey, D. N.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, A. J.;
O'Dwyer, E.;
Olsen, K.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Ronquest, M.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be $<1.4\times
10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
$<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming
negligible contribution from nuclear recoil backgrounds.
[9]
oai:arXiv.org:1601.03729 [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Das, M.;
Debris, F.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Olson, S.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$
bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic
threshold energy of 3.3$\,$keV. These data show that measures taken to control
particulate contamination in the superheated fluid resulted in the absence of
the anomalous background events observed in the first run of this bubble
chamber. One single nuclear-recoil event was observed in the data, consistent
both with the predicted background rate from neutrons and with the observed
rate of unambiguous multiple-bubble neutron scattering events. The chamber
exhibits the same excellent electron-recoil and alpha decay rejection as was
previously reported. These data provide the most stringent direct detection
constraints on weakly interacting massive particle (WIMP)-proton spin-dependent
scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[10]
oai:arXiv.org:1510.07754 [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Grandison, A.;
Hai, M.;
Hall, J.;
Harris, O.;
Jin, M.;
Krauss, C. B.;
Fallows, S.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Ramberg, E.;
Robinson, A. E.;
Rucinski, R.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Simon, P.;
Sonnenschein, A.;
Štekl, I.;
Vàzquez-Jàuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.;
Shkrob, I. A.
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector,
a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB
underground laboratory. PICO-60 is the largest bubble chamber to search for
dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60
exhibits the same excellent background rejection observed in smaller bubble
chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic
calorimetry, similar but not identical to that reported recently in a
C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown
background events, exhibiting acoustic, spatial, and timing behaviors
inconsistent with those expected from a dark matter signal. These behaviors
allow for analysis cuts to remove all background events while retaining
$48.2\%$ of the exposure. Stringent limits on weakly interacting massive
particles interacting via spin-dependent proton and spin-independent processes
are set, and most interpretations of the DAMA/LIBRA modulation signal as dark
matter interacting with iodine nuclei are ruled out.
[11]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[12]
oai:arXiv.org:1503.00008 [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hai, M.;
Hall, J.;
Harris, O.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vàzquez-Jaùregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble
chamber in the 2100 meter deep SNOLAB underground laboratory, with a total
exposure of 211.5 kg-days at four different recoil energy thresholds ranging
from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron
recoil and alpha rejection capabilities at very low thresholds, including the
first observation of a dependence of acoustic signal on alpha energy. Twelve
single nuclear recoil event candidates were observed during the run. The
candidate events exhibit timing characteristics that are not consistent with
the hypothesis of a uniform time distribution, and no evidence for a dark
matter signal is claimed. These data provide the most sensitive direct
detection constraints on WIMP-proton spin-dependent scattering to date, with
significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon
scattering.
[13]
oai:arXiv.org:1211.0909 [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Boudjemline, K.;
Caldwell, M. G. Boulay B. Cai T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Contreras, D.;
Dering, K.;
Duncan, F.;
Ford, R.;
Giuliani, R. Gagnon F.;
Golovko, M. Gold V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Lidgard, J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McKinsey, D.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, T.;
O'Dwyer, E.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Pollmann, T.;
Rau, W.;
Retiere, F.;
Ronquest, M.;
Skensved, P.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Ward, M.
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry.
[14]
oai:arXiv.org:1304.6001 [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I
Bubble Chamber
COUPP Collaboration;
Behnke, E.;
Benjamin, T.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Hall, J.;
Harnish, C.;
Levine, I.;
Lippincott, W. H.;
Moan, T.;
Nania, T.;
Neilson, R.;
Ramberg, E.;
Robinson, A. E.;
Sonnenschein, A.;
Vázquez-Jáuregui, E.;
Rivera, R. A.;
Uplegger, L.
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble
nucleation from iodine recoils in a CF3I bubble chamber in the energy range of
interest for a dark matter search. These interactions cannot be probed by
standard neutron calibration methods, so we develop a new technique by
observing the elastic scattering of 12 GeV/c negative pions. The pions are
tracked with a silicon pixel telescope and the reconstructed scattering angle
provides a measure of the nuclear recoil kinetic energy. The bubble chamber was
operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the
results depends on the response to fluorine and carbon recoils, but in general
we find agreement with the predictions of the classical bubble nucleation
theory. This measurement confirms the applicability of CF3I as a target for
spin-independent dark matter interactions and represents a novel technique for
calibration of superheated fluid detectors.
[15]
oai:arXiv.org:1310.8327 [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Cushman, P.;
Galbiati, C.;
McKinsey, D. N.;
Robertson, H.;
Tait, T. M. P.;
Bauer, D.;
Borgland, A.;
Cabrera, B.;
Calaprice, F.;
Cooley, J.;
Empl, T.;
Essig, R.;
Figueroa-Feliciano, E.;
Gaitskell, R.;
Golwala, S.;
Hall, J.;
Hill, R.;
Hime, A.;
Hoppe, E.;
Hsu, L.;
Hungerford, E.;
Jacobsen, R.;
Kelsey, M.;
Lang, R. F.;
Lippincott, W. H.;
Loer, B.;
Luitz, S.;
Mandic, V.;
Mardon, J.;
Maricic, J.;
Maruyama, R.;
Mahapatra, R.;
Nelson, H.;
Orrell, J.;
Palladino, K.;
Pantic, E.;
Partridge, R.;
Ryd, A.;
Saab, T.;
Sadoulet, B.;
Schnee, R.;
Shepherd, W.;
Sonnenschein, A.;
Sorensen, P.;
Szydagis, M.;
Volansky, T.;
Witherell, M.;
Wright, D.;
Zurek, K.
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection
subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader
Particle Physics community to produce this document. The charge to CF1 was (a)
to summarize the current status and projected sensitivity of WIMP direct
detection experiments worldwide, (b) motivate WIMP dark matter searches over a
broad parameter space by examining a spectrum of WIMP models, (c) establish a
community consensus on the type of experimental program required to explore
that parameter space, and (d) identify the common infrastructure required to
practically meet those goals.
[16]
oai:arXiv.org:1306.2349 [pdf] - 717330
A Spin-Dependent Interpretation for Possible Signals of Light Dark
Matter
Submitted: 2013-06-10
Signals broadly compatible with light (7-10 GeV) dark matter have been
reported in three direct detection experiments: CoGeNT, DAMA/LIBRA, and CDMS-II
silicon. These possible signals have been interpreted in the context of
spin-independent interactions between the target nuclei and dark matter,
although there is tension with null results, particularly from xenon-based
experiments. In this paper, we demonstrate that the CoGeNT and CDMS-II silicon
results are also compatible assuming a spin-dependent neutron interaction,
though this is in tension with xenon-based experiments and PICASSO. The tension
with the null results from XENON100 and XENON10 is approximately the same as
for the spin-independent coupling. All three experimental signals can be made
compatible through a combination of spin-dependent interactions with both the
proton and neutron, although such a scenario increases the conflict with the
null results of other experiments.
[17]
oai:arXiv.org:1204.3094 [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber
operated in a deep underground site
Behnke, E.;
Behnke, J.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Conner, A.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Grace, E.;
Hall, J.;
Hu, M.;
Levine, I.;
Lippincott, W. H.;
Moan, T.;
Nania, T.;
Ramberg, E.;
Robinson, A. E.;
Sonnenschein, A.;
Szydagis, M.;
Vázquez-Jáuregui, E.
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber
in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of
ultrasound analysis in discriminating alpha-decay background events from single
nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of
alpha-decay events. Twenty single nuclear recoil event candidates and three
multiple bubble events were observed during a total exposure of 553 kg-days
distributed over three different bubble nucleation thresholds. The effective
exposure for single bubble recoil-like events was 437.4 kg-days. A neutron
background internal to the apparatus, of known origin, is estimated to account
for five single nuclear recoil events and is consistent with the observed rate
of multiple bubble events. This observation provides world best direct
detection constraints on WIMP-proton spin-dependent scattering for WIMP masses
$>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent
interactions.
[18]
oai:arXiv.org:1111.3260 [pdf] - 548322
Scintillation yield and time dependence from electronic and nuclear
recoils in liquid neon
Submitted: 2011-11-14, last modified: 2012-08-13
We have performed measurements of scintillation light in liquid neon,
observing a signal yield in our detector as high as (3.5 $\pm$ 0.4)
photoelectrons/keV. We measure pulse shape discrimination efficiency between
electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear
recoil energy. We also measure the \leff\, parameter in liquid neon between 30
and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50
keV. We observe a dependence of the scintillation time distribution and signal
yield on the pressure and temperature of the liquid neon.
[19]
oai:arXiv.org:1004.0373 [pdf] - 672810
Measurement of scintillation efficiency for nuclear recoils in liquid
argon
Submitted: 2010-04-02, last modified: 2012-05-08
The scintillation light yield of liquid argon from nuclear recoils relative
to electronic recoils has been measured as a function of recoil energy from 10
keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the
nuclear recoil scintillation response to the electronic recoil response, is
0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
[20]
oai:arXiv.org:1111.6192 [pdf] - 530964
Comments on "First Results of the Phase II SIMPLE Dark Matter Search"
Submitted: 2011-11-26
The SIMPLE Collaboration has reported results from their superheated C2ClF5
droplet detectors, including a description of acoustic discrimination between
\alpha decays and nuclear recoils. Our concern is that the events in the
neutron calibration data and the events identified as neutrons in the physics
data are not drawn from the same parent distribution. This fact calls into
question the identification of the background events as neutrons, the use of
the calibration data to define the acceptance of WIMP-induced nuclear recoils,
and the observation of discrimination against \alpha's.
[21]
oai:arXiv.org:0911.5453 [pdf] - 146838
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Submitted: 2009-11-30
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration
source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are
produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$
scintillation peak at 41.5 keV appears in both liquids when filling our
detector through a piece of zeolite coated with $^{83}$Rb. Based on this
scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a
resolution of 6% ($\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a
resolution of 19% ($\sigma$/E). The observed peak intensity subsequently decays
with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we
find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in
the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful
calibration source for liquid argon and neon dark matter and solar neutrino
detectors.
[22]
oai:arXiv.org:0709.1880 [pdf] - 4868
Detection and Imaging of He_2 Molecules in Superfluid Helium
Submitted: 2007-09-12, last modified: 2007-12-18
We present data that show a cycling transition can be used to detect and
image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate
that limitations on the cycling efficiency due to the vibrational structure of
the molecule can be mitigated by the use of repumping lasers. Images of the
molecules obtained using the method are also shown. This technique gives rise
to a new kind of ionizing radiation detector. The use of He$_2$ triplet
molecules as tracer particles in the superfluid promises to be a powerful tool
for visualization of both quantum and classical turbulence in liquid helium.
[23]
oai:arXiv.org:astro-ph/0702202 [pdf] - 89256
Demonstration of photomultiplier tube operation at 29 K
Submitted: 2007-02-07
We describe measurements of gain, dark current, and quantum efficiency
obtained while cooling a Hamamatsu R5912-02-MOD photomultiplier tube from room
temperature to 29 K. We found that the PMT operated normally down to 29 K, with
a reduced gain and quantum efficiency at the lowest temperatures. Furthermore,
we found that the dark count rate increased as the temperature decreased. We
conclude that these PMTs appear to be adequate for the requirements of the
CLEAN experiment.
[24]
oai:arXiv.org:astro-ph/0612108 [pdf] - 87446
Scintillation of liquid neon from electronic and nuclear recoils
Submitted: 2006-12-04
We have measured the time dependence of scintillation light from electronic
and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2
us. Pulse shape discrimination is investigated as a means of identifying event
type in liquid neon. Finally, the nuclear recoil scintillation efficiency is
measured to be 0.26+-0.03 for 387 keV nuclear recoils.
[25]
oai:arXiv.org:nucl-ex/0503006 [pdf] - 118468
Trace Detection of Metastable Helium Molecules in Superfluid Helium by
Laser-Induced Fluorescence
Submitted: 2005-03-11
We describe an approach to detecting ionizing radiation that combines the
special properties of superfluid helium with the sensitivity of quantum optics
techniques. Ionization in liquid helium results in the copious production of
metastable helium molecules, which can be detected by laser-induced
fluorescence. Each molecule can be probed many times using a cycling
transition, resulting in the detection of individual molecules with high signal
to noise. This technique could be used to detect neutrinos, weakly interacting
massive particles, and ultracold neutrons, and to image superfluid flow in
liquid He-4.