Normalized to: Lipartito, I.
[1]
oai:arXiv.org:1911.06434 [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance
Detectors
Zobrist, Nicholas;
Coiffard, Grégoire;
Bumble, Bruce;
Swimmer, Noah;
Steiger, Sarah;
Daal, Miguel;
Collura, Giulia;
Walter, Alex B.;
Bockstiegel, Clint;
Fruitwala, Neelay;
Lipartito, Isabel;
Mazin, Benjamin A.
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance
Detectors (MKIDs) sensitive to single photons in the optical to near-infrared
range using hafnium as the sensor material. Our test device had a
superconducting transition temperature of 395 mK and a room temperature normal
state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the
device displayed internal quality factors of around 200,000. Similar to the
analysis of MKIDs made from other highly resistive superconductors, we find
that modeling the temperature response of the detector requires an extra
broadening parameter in the superconducting density of states. Finally, we show
that this material and design is compatible with a full-array fabrication
process which resulted in pixels with decay times of about 40 $\mu$s and
resolving powers of ~9 at 800 nm.
[2]
oai:arXiv.org:1908.02775 [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in
the 2020s
Mazin, Benjamin A.;
Bailey, Jeb;
Bartlett, Jo;
Bockstiegel, Clint;
Bumble, Bruce;
Coiffard, Gregoire;
Currie, Thayne;
Daal, Miguel;
Davis, Kristina;
Dodkins, Rupert;
Fruitwala, Neelay;
Jovanovic, Nemanja;
Lipartito, Isabel;
Lozi, Julien;
Males, Jared;
Mawet, Dimitri;
Meeker, Seth;
O'Brien, Kieran;
Rich, Michael;
Smith, Jenny;
Steiger, Sarah;
Swimmer, Noah;
Walter, Alex;
Zobrist, Nick;
Zmuidzinas, Jonas
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are
superconducting photon counting detectors capable of measuring the energy and
arrival time of individual OIR photons without read noise or dark current. In
this whitepaper we will discuss the current status of OIR MKIDs and MKID-based
instruments.
[3]
oai:arXiv.org:1907.03078 [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical
Microwave Kinetic Inductance Detectors
Zobrist, Nicholas;
Eom, Byeong Ho;
Day, Peter;
Mazin, Benjamin A.;
Meeker, Seth R.;
Bumble, Bruce;
LeDuc, Henry G.;
Coiffard, Gérgoire;
Szypryt, Paul;
Fruitwala, Neelay;
Lipartito, Isabel;
Bockstiegel, Clint
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic
Inductance Detector (MKID) can be degraded by noise coming from the primary low
temperature amplifier in the detector's readout system. Until recently, quantum
limited amplifiers have been incompatible with these detectors due to dynamic
range, power, and bandwidth constraints. However, we show that a kinetic
inductance based traveling wave parametric amplifier can be used for this
application and reaches the quantum limit. The total system noise for this
readout scheme was equal to ~2.1 in units of quanta. For incident photons in
the 800 to 1300 nm range, the amplifier increased the average resolving power
of the detector from ~6.7 to 9.3 at which point the resolution becomes limited
by noise on the pulse height of the signal. Noise measurements suggest that a
resolving power of up to 25 is possible if redesigned detectors can remove this
additional noise source.
[4]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[5]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.
[6]
oai:arXiv.org:1401.4474 [pdf] - 1202831
The solar chromosphere observed at 1 Hz and 0."2 resolution
Submitted: 2014-01-17
We recently reported extremely rapid changes in chromospheric fine structure
observed using the IBIS instrument in the red wing of H alpha. Here, we examine
data obtained during the same observing run (August 7 2010), of a mature active
region NOAA 11094. We analyze more IBIS data including wavelength scans and
data from the Solar Dynamics Observatory, all from within a 30 minute interval.
Using a slab radiative transfer model, we investigate the physical nature of
fibrils in terms of tube-like vs. sheet-like structures. Principal Component
Analysis shows that the very rapid H alpha variations in the line wings depend
mostly on changes of line width and line shift, but for Ca II 854.2 the
variations are dominated by changes in column densities. The tube model must be
rejected for a small but significant class of fibrils undergoing very rapid
changes. If our wing data arise from the same structures leading to "type II
spicules", our analysis calls into question much recent work. Instead the data
do not reject the hypothesis that some fibrils are optical superpositions of
plasma collected into sheets. We review how Parker's theory of tangential
discontinuities naturally leads to plasma collecting into sheets, and show that
the sheet picture is falsifiable. Chromospheric fine structures seem to be
populated by both tubes and sheets. We assess the merits of spectral imaging
versus slit spectroscopy for future studies.