sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Lipartito, Isabel

Normalized to: Lipartito, I.

6 article(s) in total. 43 co-authors, from 1 to 5 common article(s). Median position in authors list is 11,5.

[1]  oai:arXiv.org:1911.06434  [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
Comments:
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $\mu$s and resolving powers of ~9 at 800 nm.
[2]  oai:arXiv.org:1908.02775  [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s
Comments: Astro2020 APC Whitepaper. 16 pages, 10 figures
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
[3]  oai:arXiv.org:1907.03078  [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
Comments:
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
[4]  oai:arXiv.org:1803.10420  [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Comments: 17 pages, 17 figures. PASP Published
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
[5]  oai:arXiv.org:1710.07318  [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
Comments: 16 pages, 8 figures, published in Optics Express
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.
[6]  oai:arXiv.org:1401.4474  [pdf] - 1202831
The solar chromosphere observed at 1 Hz and 0."2 resolution
Comments: to appear in the Astrophysical Journal
Submitted: 2014-01-17
We recently reported extremely rapid changes in chromospheric fine structure observed using the IBIS instrument in the red wing of H alpha. Here, we examine data obtained during the same observing run (August 7 2010), of a mature active region NOAA 11094. We analyze more IBIS data including wavelength scans and data from the Solar Dynamics Observatory, all from within a 30 minute interval. Using a slab radiative transfer model, we investigate the physical nature of fibrils in terms of tube-like vs. sheet-like structures. Principal Component Analysis shows that the very rapid H alpha variations in the line wings depend mostly on changes of line width and line shift, but for Ca II 854.2 the variations are dominated by changes in column densities. The tube model must be rejected for a small but significant class of fibrils undergoing very rapid changes. If our wing data arise from the same structures leading to "type II spicules", our analysis calls into question much recent work. Instead the data do not reject the hypothesis that some fibrils are optical superpositions of plasma collected into sheets. We review how Parker's theory of tangential discontinuities naturally leads to plasma collecting into sheets, and show that the sheet picture is falsifiable. Chromospheric fine structures seem to be populated by both tubes and sheets. We assess the merits of spectral imaging versus slit spectroscopy for future studies.