sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Ling, Hong Y.

Normalized to: Ling, H.

13 article(s) in total. 185 co-authors, from 1 to 10 common article(s). Median position in authors list is 11,0.

[1]  oai:arXiv.org:1608.01075  [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives
Tamura, Naoyuki; Takato, Naruhisa; Shimono, Atsushi; Moritani, Yuki; Yabe, Kiyoto; Ishizuka, Yuki; Ueda, Akitoshi; Kamata, Yukiko; Aghazarian, Hrand; Arnouts, Stephane; Barban, Gabriel; Barkhouser, Robert H.; Borges, Renato C.; Braun, David F.; Carr, Michael A.; Chabaud, Pierre-Yves; Chang, Yin-Chang; Chen, Hsin-Yo; Chiba, Masashi; Chou, Richard C. Y.; Chu, You-Hua; Cohen, Judith G.; de Almeida, Rodrigo P.; de Oliveira, Antonio C.; de Oliveira, Ligia S.; Dekany, Richard G.; Dohlen, Kjetil; Santos, Jesulino B. dos; Santos, Leandro H. dos; Ellis, Richard S.; Fabricius, Maximilian; Ferrand, Didier; Ferreira, Decio; Golebiowski, Mirek; Greene, Jenny E.; Gross, Johannes; Gunn, James E.; Hammond, Randolph; Harding, Albert; Hart, Murdock; Heckman, Timothy M.; Hirata, Christopher M.; Ho, Paul; Hope, Stephen C.; Hovland, Larry; Hsu, Shu-Fu; Hu, Yen-Shan; Huang, Ping-Jie; Jaquet, Marc; Jing, Yipeng; Karr, Jennifer; Kimura, Masahiko; King, Matthew E.; Komatsu, Eiichiro; Brun, Vincent Le; Fevre, Olivier Le; Fur, Arnaud Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig P.; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas S.; de Oliveira, Claudia Mendes; Minowa, Yosuke; Morantz, Chaz N.; Murayama, Hitoshi; Murray, Graham J.; Ohyama, Youichi; Orndorff, Joseph; Pascal, Sandrine; Pereira, Jefferson M.; Reiley, Daniel J.; Reinecke, Martin; Ritter, Andreas; Roberts, Mitsuko; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Sodre, Laerte; Spergel, David N.; Steinkraus, Aaron J.; Strauss, Michael A.; Surace, Christian; Suto, Yasushi; Suzuki, Nao; Swinbank, John; Tait, Philip J.; Takada, Masahiro; Tamura, Tomonori; Tanaka, Yoko; Tresse, Laurence; Verducci, Orlando; Vibert, Didier; Vidal, Clement; Wang, Shiang-Yu; Wen, Chih-Yi; Yan, Chi-Hung; Yasuda, Naoki
Comments: 17 pages, 10 figures. Proceeding of SPIE Astronomical Telescopes and Instrumentation 2016
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
[2]  oai:arXiv.org:1608.00675  [pdf] - 1531167
The Current Status of Prime Focus Instrument of Subaru Prime Focus Spectrograph
Comments: 9 pages, 8 figures, SPIE proceeding
Submitted: 2016-08-01
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding cameras (AGCs), the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC's Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy. In this report, the latest status of PFI development will be given including the performance of PFI components, the setup and performance of the integration and testing equipment.
[3]  oai:arXiv.org:1608.00676  [pdf] - 1447926
Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope
Comments: 11 pages, 15 figures. SPIE proceeding. arXiv admin note: text overlap with arXiv:1408.2876
Submitted: 2016-08-01
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less than 10um. The metrology camera system (MCS) serves as the optical encoder of the fiber motors for the configuring of fibers. MCS provides the fiber positions within a 5um error over the 45 cm focal plane. The information from MCS will be fed into the fiber positioner control system for the closed loop control. MCS will be located at the Cassegrain focus of Subaru telescope in order to to cover the whole focal plane with one 50M pixel Canon CMOS camera. It is a 380mm Schmidt type telescope which generates a uniform spot size with a 10 micron FWHM across the field for reasonable sampling of PSF. Carbon fiber tubes are used to provide a stable structure over the operating conditions without focus adjustments. The CMOS sensor can be read in 0.8s to reduce the overhead for the fiber configuration. The positions of all fibers can be obtained within 0.5s after the readout of the frame. This enables the overall fiber configuration to be less than 2 minutes. MCS will be installed inside a standard Subaru Cassgrain Box. All components that generate heat are located inside a glycol cooled cabinet to reduce the possible image motion due to heat. The optics and camera for MCS have been delivered and tested. The mechanical parts and supporting structure are ready as of spring 2016. The integration of MCS will start in the summer of 2016.
[4]  oai:arXiv.org:1508.03336  [pdf] - 1319612
Planet Sensitivity from Combined Ground- and Space-based Microlensing Observations
Comments: 10 pages, 5 figures, 1 table; ApJ in press
Submitted: 2015-08-13, last modified: 2015-10-12
To move one step forward toward a Galactic distribution of planets, we present the first planet sensitivity analysis for microlensing events with simultaneous observations from space and the ground. We present this analysis for two such events, OGLE-2014-BLG-0939 and OGLE-2014-BLG-0124, which both show substantial planet sensitivity even though neither of them reached high magnification. This suggests that an ensemble of low to moderate magnification events can also yield significant planet sensitivity and therefore probability to detect planets. The implications of our results to the ongoing and future space-based microlensing experiments to measure the Galactic distribution of planets are discussed.
[5]  oai:arXiv.org:1507.00725  [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio Vital; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsu, Shu-Fu; Hu, Yen-Shan; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Fèvre, Olivier Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas Souza; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D.; Vilaça, Rodrigo de Paiva; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; Santos, Jesulino Bispo dos; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung
Comments: 19 pages, 11 figures
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.
[6]  oai:arXiv.org:1408.2877  [pdf] - 1216271
Prime Focus Instrument of Prime Focus Spectrograph for Subaru Telescope
Comments: 9 pages, 7 figures, SPIE Astronomical Telescopes and Instrumentation 2014
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding (A&G) cameras, the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy.
[7]  oai:arXiv.org:1408.2825  [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio Vital; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsuc, Shu-Fu; Hu, Yen-Shan; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Fèvre, Olivier Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas Souza; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D.; Vilaça, Rodrigo de Paiva; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; Santos, Jesulino Bispo dos; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung
Comments: 14 pages, 12 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy V, Suzanne K. Ramsay, Ian S. McLean, Hideki Takami, Editors, Proc. SPIE 9147 (2014)"
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.
[8]  oai:arXiv.org:1408.2876  [pdf] - 1216270
Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope
Comments: 10 pages, 12 figures, SPIE Astronomical Telescopes and Instrumentation 2014
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. The metrology camera system of PFS serves as the optical encoder of the COBRA fiber motors for the configuring of fibers. The 380mm diameter aperture metrology camera will locate at the Cassegrain focus of Subaru telescope to cover the whole focal plane with one 50M pixel Canon CMOS sensor. The metrology camera is designed to provide the fiber position information within 5{\mu}m error over the 45cm focal plane. The positions of all fibers can be obtained within 1s after the exposure is finished. This enables the overall fiber configuration to be less than 2 minutes.
[9]  oai:arXiv.org:1210.2740  [pdf] - 1151992
Detectors and cryostat design for the SuMIRe Prime Focus Spectrograph (PFS)
Comments:
Submitted: 2012-10-09
We describe the conceptual design of the camera cryostats, detectors, and detector readout electronics for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the Subaru telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering wavelength ranges 3800 {\AA} - 6700 {\AA}, 6500 {\AA} - 10000 {\AA}, and 9700 {\AA} - 13000 {\AA}, with the dispersed light being imaged in each channel by a f/1.10 vacuum Schmidt camera. In the blue and red channels a pair of Hamamatsu 2K x 4K edge-buttable CCDs with 15 um pixels are used to form a 4K x 4K array. For the IR channel, the new Teledyne 4K x 4K, 15 um pixel, mercury-cadmium-telluride sensor with substrate removed for short-wavelength response and a 1.7 um cutoff will be used. Identical detector geometry and a nearly identical optical design allow for a common cryostat design with the only notable difference being the need for a cold radiation shield in the IR camera to mitigate thermal background. This paper describes the details of the cryostat design and cooling scheme, relevant thermal considerations and analysis, and discusses the detectors and detector readout electronics.
[10]  oai:arXiv.org:1210.2719  [pdf] - 574579
Prime Focus Spectrograph - Subaru's future -
Comments: 13 pages, 11 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)"
Submitted: 2012-10-09
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 {\mu}m to 1.3 {\mu}m will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.
[11]  oai:arXiv.org:1210.2730  [pdf] - 574588
The metrology cameras for Subaru PFS and FMOS
Comments: 7 pages, 5 figures; Ground-based and Airborne Instrumentation for Astronomy IV, Proc. SPIE 8446 (2012)
Submitted: 2012-10-09
The Prime Focus Spectrograph (PFS) is a new multi-fiber spectrograph on Subaru telescope. PFS will cover around 1.4 degree diameter field with ~2400 fibers. To ensure precise positioning of the fibers, a metrology camera is designed to provide the fiber position information within 5 {\mu}m error. The final positioning accuracy of PFS is targeted to be better than 10 {\mu}m. The metrology camera will locate at the Cassegrain focus of Subaru telescope to cover the whole focal plane. The PFS metrology camera will also serve for the existing multi-fiber infrared spectrograph FMOS.
[12]  oai:arXiv.org:1112.4169  [pdf] - 1092460
Cosmological Inhomogeneities with Bose-Einstein Condensate Dark Matter
Comments: 17 pages, 2 figures; typos corrected, references added
Submitted: 2011-12-18, last modified: 2012-01-19
We consider the growth of cosmological perturbations to the energy density of dark matter during matter domination when dark matter is a scalar field that has undergone Bose-Einstein condensation. We study these inhomogeneities within the framework of both Newtonian gravity, where the calculation and results are more transparent, and General Relativity. The direction we take is to derive analytical expressions, which can be obtained in the small pressure limit. Throughout we compare our results to those of the standard cosmology, where dark matter is assumed pressureless, using our analytical expressions to showcase precise differences. We find, compared to the standard cosmology, that Bose-Einstein condensate dark matter leads to a scale factor, gravitational potential and density contrast that increase at faster rates.
[13]  oai:arXiv.org:1004.4692  [pdf] - 903108
Vortices in Bose-Einstein Condensate Dark Matter
Comments: 10 pages, 3 figures; minor corrections, references added
Submitted: 2010-04-26, last modified: 2010-09-30
If dark matter in the galactic halo is composed of bosons that form a Bose-Einstein condensate then it is likely that the rotation of the halo will lead to the nucleation of vortices. After a review of the Gross-Pitaevskii equation, the Thomas-Fermi approximation and vortices in general, we consider vortices in detail. We find strong bounds for the boson mass, interaction strength, the shape and quantity of vortices in the halo, the critical rotational velocity for the nucleation of vortices and, in the Thomas-Fermi regime, an exact solution for the mass density of a single, axisymmetric vortex.