oai:arXiv.org:1604.02593 [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an
Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5
MHz
Gottardi, Luciano;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
de Korte, Piet;
van der Kuur, Jan;
Lindeman, Mark;
Ridder, Marcel
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the
ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on
board of the Japanese space mission SPICA. The FDM prototype of the instrument
requires critical and complex optimizations. For single pixel characterization
under AC bias we are developing a simple FDM system working in the frequency
range from 1 to 5 MHz, based on the open loop read-out of a linearized
two-stage SQUID amplifier and high Q lithographic LC resonators. We describe
the details of the experimental set-up required to achieve low power loading (<
1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We
conclude the paper by comparing the performance of a $4 \cdot 10^{-19}
W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[2]
oai:arXiv.org:1604.02600 [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and
microcalorimeters
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
van der Kuur, Jan;
van der Linden, Anoton;
Lindeman, Marcel;
Ridder, Marcel
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the
read-out of the TES-based detector array for the future infrared and X-ray
space mission. We describe the performances of a multiplexer designed to
increase the experimental throughput in the characterisation of ultra-low noise
equivalent power (NEP) TES bolometers and high energy resolving power X-ray
microcalorimeters arrays under ac and dc bias. We discuss the results obtained
using the TiAu TES bolometers array fabricated at SRON with measured dark NEP
below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[3]
oai:arXiv.org:0704.3066 [pdf] - 681
Complex impedance measurements of calorimeters and bolometers:
correction for stray impedances
Submitted: 2007-04-23
Impedance measurements provide a useful probe of the physics of bolometers
and calorimeters. We describe a method for measuring the complex impedance of
these devices. In previous work, stray impedances and readout electronics of
the measurement apparatus have resulted in artifacts in the impedance data. The
new technique allows experimenters to find an independent Thevenin or Norton
equivalent circuit for each frequency. This method allows experimenters to
easily isolate the device impedance from the effects of parasitic impedances
and frequency dependent gains in amplifiers.