sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Lindeman, Mark. A.

Normalized to: Lindeman, M.

3 article(s) in total. 17 co-authors, from 1 to 2 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1604.02593  [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz
Comments: 6 pages, 5 figures
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We conclude the paper by comparing the performance of a $4 \cdot 10^{-19} W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[2]  oai:arXiv.org:1604.02600  [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters
Comments: 7 pages, 6 figures, Proc. SPIE 8453, High Energy, Optical, and Infrared Detectors for Astronomy V, 845333 (25 September 2012). arXiv admin note: text overlap with arXiv:1604.02593
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[3]  oai:arXiv.org:0704.3066  [pdf] - 681
Complex impedance measurements of calorimeters and bolometers: correction for stray impedances
Comments: 5 pages, 6 figures
Submitted: 2007-04-23
Impedance measurements provide a useful probe of the physics of bolometers and calorimeters. We describe a method for measuring the complex impedance of these devices. In previous work, stray impedances and readout electronics of the measurement apparatus have resulted in artifacts in the impedance data. The new technique allows experimenters to find an independent Thevenin or Norton equivalent circuit for each frequency. This method allows experimenters to easily isolate the device impedance from the effects of parasitic impedances and frequency dependent gains in amplifiers.