Normalized to: Lim, K.
[1]
oai:arXiv.org:1812.08085 [pdf] - 1801453
Abstracting the storage and retrieval of image data at the LSST
Submitted: 2018-12-19
Writing generic data processing pipelines requires that the algorithmic code
does not ever have to know about data formats of files, or the locations of
those files. At LSST we have a software system known as "the Data Butler," that
abstracts these details from the software developer. Scientists can specify the
dataset they want in terms they understand, such as filter, observation
identifier, date of observation, and instrument name, and the Butler translates
that to one or more files which are read and returned to them as a single
Python object. Conversely, once they have created a new dataset they can give
it back to the Butler, with a label describing its new status, and the Butler
can write it in whatever format it has been configured to use. All
configuration is in YAML and supports standard defaults whilst allowing
overrides.
[2]
oai:arXiv.org:1806.09788 [pdf] - 1764379
The COSINE-100 Data Acquisition System
Collaboration, COSINE-100;
:;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W. G.;
Kang, W. S.;
Kauer, M.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, M. C.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, M. H.;
Lim, K. E.;
Leonard, D. S.;
Maruyama, R. H.;
Mouton, F.;
Na, S.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Prihtiadi, H.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.
Submitted: 2018-06-26
COSINE-100 is a dark matter direct detection experiment designed to test the
annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100
consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid
scintillator veto, and 37 muon detector panels. We present details of the data
acquisition system of COSINE-100, including waveform storage using flash
analog-to-digital converters for crystal events and integrated charge storage
using charge-sensitive analog-to-digital converters for liquid scintillator and
plastic scintillator muon veto events. We also discuss several trigger
conditions developed in order to distinguish signal events from photomultiplier
noise events. The total trigger rate observed for the crystal/liquid
scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
[3]
oai:arXiv.org:0805.2366 [pdf] - 1934226
LSST: from Science Drivers to Reference Design and Anticipated Data
Products
Ivezić, Željko;
Kahn, Steven M.;
Tyson, J. Anthony;
Abel, Bob;
Acosta, Emily;
Allsman, Robyn;
Alonso, David;
AlSayyad, Yusra;
Anderson, Scott F.;
Andrew, John;
Angel, James Roger P.;
Angeli, George Z.;
Ansari, Reza;
Antilogus, Pierre;
Araujo, Constanza;
Armstrong, Robert;
Arndt, Kirk T.;
Astier, Pierre;
Aubourg, Éric;
Auza, Nicole;
Axelrod, Tim S.;
Bard, Deborah J.;
Barr, Jeff D.;
Barrau, Aurelian;
Bartlett, James G.;
Bauer, Amanda E.;
Bauman, Brian J.;
Baumont, Sylvain;
Becker, Andrew C.;
Becla, Jacek;
Beldica, Cristina;
Bellavia, Steve;
Bianco, Federica B.;
Biswas, Rahul;
Blanc, Guillaume;
Blazek, Jonathan;
Blandford, Roger D.;
Bloom, Josh S.;
Bogart, Joanne;
Bond, Tim W.;
Borgland, Anders W.;
Borne, Kirk;
Bosch, James F.;
Boutigny, Dominique;
Brackett, Craig A.;
Bradshaw, Andrew;
Brandt, William Nielsen;
Brown, Michael E.;
Bullock, James S.;
Burchat, Patricia;
Burke, David L.;
Cagnoli, Gianpietro;
Calabrese, Daniel;
Callahan, Shawn;
Callen, Alice L.;
Chandrasekharan, Srinivasan;
Charles-Emerson, Glenaver;
Chesley, Steve;
Cheu, Elliott C.;
Chiang, Hsin-Fang;
Chiang, James;
Chirino, Carol;
Chow, Derek;
Ciardi, David R.;
Claver, Charles F.;
Cohen-Tanugi, Johann;
Cockrum, Joseph J.;
Coles, Rebecca;
Connolly, Andrew J.;
Cook, Kem H.;
Cooray, Asantha;
Covey, Kevin R.;
Cribbs, Chris;
Cui, Wei;
Cutri, Roc;
Daly, Philip N.;
Daniel, Scott F.;
Daruich, Felipe;
Daubard, Guillaume;
Daues, Greg;
Dawson, William;
Delgado, Francisco;
Dellapenna, Alfred;
de Peyster, Robert;
de Val-Borro, Miguel;
Digel, Seth W.;
Doherty, Peter;
Dubois, Richard;
Dubois-Felsmann, Gregory P.;
Durech, Josef;
Economou, Frossie;
Eracleous, Michael;
Ferguson, Henry;
Figueroa, Enrique;
Fisher-Levine, Merlin;
Focke, Warren;
Foss, Michael D.;
Frank, James;
Freemon, Michael D.;
Gangler, Emmanuel;
Gawiser, Eric;
Geary, John C.;
Gee, Perry;
Geha, Marla;
Gessner, Charles J. B.;
Gibson, Robert R.;
Gilmore, D. Kirk;
Glanzman, Thomas;
Glick, William;
Goldina, Tatiana;
Goldstein, Daniel A.;
Goodenow, Iain;
Graham, Melissa L.;
Gressler, William J.;
Gris, Philippe;
Guy, Leanne P.;
Guyonnet, Augustin;
Haller, Gunther;
Harris, Ron;
Hascall, Patrick A.;
Haupt, Justine;
Hernandez, Fabio;
Herrmann, Sven;
Hileman, Edward;
Hoblitt, Joshua;
Hodgson, John A.;
Hogan, Craig;
Huang, Dajun;
Huffer, Michael E.;
Ingraham, Patrick;
Innes, Walter R.;
Jacoby, Suzanne H.;
Jain, Bhuvnesh;
Jammes, Fabrice;
Jee, James;
Jenness, Tim;
Jernigan, Garrett;
Jevremović, Darko;
Johns, Kenneth;
Johnson, Anthony S.;
Johnson, Margaret W. G.;
Jones, R. Lynne;
Juramy-Gilles, Claire;
Jurić, Mario;
Kalirai, Jason S.;
Kallivayalil, Nitya J.;
Kalmbach, Bryce;
Kantor, Jeffrey P.;
Karst, Pierre;
Kasliwal, Mansi M.;
Kelly, Heather;
Kessler, Richard;
Kinnison, Veronica;
Kirkby, David;
Knox, Lloyd;
Kotov, Ivan V.;
Krabbendam, Victor L.;
Krughoff, K. Simon;
Kubánek, Petr;
Kuczewski, John;
Kulkarni, Shri;
Ku, John;
Kurita, Nadine R.;
Lage, Craig S.;
Lambert, Ron;
Lange, Travis;
Langton, J. Brian;
Guillou, Laurent Le;
Levine, Deborah;
Liang, Ming;
Lim, Kian-Tat;
Lintott, Chris J.;
Long, Kevin E.;
Lopez, Margaux;
Lotz, Paul J.;
Lupton, Robert H.;
Lust, Nate B.;
MacArthur, Lauren A.;
Mahabal, Ashish;
Mandelbaum, Rachel;
Marsh, Darren S.;
Marshall, Philip J.;
Marshall, Stuart;
May, Morgan;
McKercher, Robert;
McQueen, Michelle;
Meyers, Joshua;
Migliore, Myriam;
Miller, Michelle;
Mills, David J.;
Miraval, Connor;
Moeyens, Joachim;
Monet, David G.;
Moniez, Marc;
Monkewitz, Serge;
Montgomery, Christopher;
Mueller, Fritz;
Muller, Gary P.;
Arancibia, Freddy Muñoz;
Neill, Douglas R.;
Newbry, Scott P.;
Nief, Jean-Yves;
Nomerotski, Andrei;
Nordby, Martin;
O'Connor, Paul;
Oliver, John;
Olivier, Scot S.;
Olsen, Knut;
O'Mullane, William;
Ortiz, Sandra;
Osier, Shawn;
Owen, Russell E.;
Pain, Reynald;
Palecek, Paul E.;
Parejko, John K.;
Parsons, James B.;
Pease, Nathan M.;
Peterson, J. Matt;
Peterson, John R.;
Petravick, Donald L.;
Petrick, M. E. Libby;
Petry, Cathy E.;
Pierfederici, Francesco;
Pietrowicz, Stephen;
Pike, Rob;
Pinto, Philip A.;
Plante, Raymond;
Plate, Stephen;
Price, Paul A.;
Prouza, Michael;
Radeka, Veljko;
Rajagopal, Jayadev;
Rasmussen, Andrew P.;
Regnault, Nicolas;
Reil, Kevin A.;
Reiss, David J.;
Reuter, Michael A.;
Ridgway, Stephen T.;
Riot, Vincent J.;
Ritz, Steve;
Robinson, Sean;
Roby, William;
Roodman, Aaron;
Rosing, Wayne;
Roucelle, Cecille;
Rumore, Matthew R.;
Russo, Stefano;
Saha, Abhijit;
Sassolas, Benoit;
Schalk, Terry L.;
Schellart, Pim;
Schindler, Rafe H.;
Schmidt, Samuel;
Schneider, Donald P.;
Schneider, Michael D.;
Schoening, William;
Schumacher, German;
Schwamb, Megan E.;
Sebag, Jacques;
Selvy, Brian;
Sembroski, Glenn H.;
Seppala, Lynn G.;
Serio, Andrew;
Serrano, Eduardo;
Shaw, Richard A.;
Shipsey, Ian;
Sick, Jonathan;
Silvestri, Nicole;
Slater, Colin T.;
Smith, J. Allyn;
Smith, R. Chris;
Sobhani, Shahram;
Soldahl, Christine;
Storrie-Lombardi, Lisa;
Stover, Edward;
Strauss, Michael A.;
Street, Rachel A.;
Stubbs, Christopher W.;
Sullivan, Ian S.;
Sweeney, Donald;
Swinbank, John D.;
Szalay, Alexander;
Takacs, Peter;
Tether, Stephen A.;
Thaler, Jon J.;
Thayer, John Gregg;
Thomas, Sandrine;
Thukral, Vaikunth;
Tice, Jeffrey;
Trilling, David E.;
Turri, Max;
Van Berg, Richard;
Berk, Daniel Vanden;
Vetter, Kurt;
Virieux, Francoise;
Vucina, Tomislav;
Wahl, William;
Walkowicz, Lucianne;
Walsh, Brian;
Walter, Christopher W.;
Wang, Daniel L.;
Wang, Shin-Yawn;
Warner, Michael;
Wiecha, Oliver;
Willman, Beth;
Winters, Scott E.;
Wittman, David;
Wolff, Sidney C.;
Wood-Vasey, W. Michael;
Wu, Xiuqin;
Xin, Bo;
Yoachim, Peter;
Zhan, Hu
Submitted: 2008-05-15, last modified: 2018-05-23
(Abridged) We describe here the most ambitious survey currently planned in
the optical, the Large Synoptic Survey Telescope (LSST). A vast array of
science will be enabled by a single wide-deep-fast sky survey, and LSST will
have unique survey capability in the faint time domain. The LSST design is
driven by four main science themes: probing dark energy and dark matter, taking
an inventory of the Solar System, exploring the transient optical sky, and
mapping the Milky Way. LSST will be a wide-field ground-based system sited at
Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m
effective) primary mirror, a 9.6 deg$^2$ field of view, and a 3.2 Gigapixel
camera. The standard observing sequence will consist of pairs of 15-second
exposures in a given field, with two such visits in each pointing in a given
night. With these repeats, the LSST system is capable of imaging about 10,000
square degrees of sky in a single filter in three nights. The typical 5$\sigma$
point-source depth in a single visit in $r$ will be $\sim 24.5$ (AB). The
project is in the construction phase and will begin regular survey operations
by 2022. The survey area will be contained within 30,000 deg$^2$ with
$\delta<+34.5^\circ$, and will be imaged multiple times in six bands, $ugrizy$,
covering the wavelength range 320--1050 nm. About 90\% of the observing time
will be devoted to a deep-wide-fast survey mode which will uniformly observe a
18,000 deg$^2$ region about 800 times (summed over all six bands) during the
anticipated 10 years of operations, and yield a coadded map to $r\sim27.5$. The
remaining 10\% of the observing time will be allocated to projects such as a
Very Deep and Fast time domain survey. The goal is to make LSST data products,
including a relational database of about 32 trillion observations of 40 billion
objects, available to the public and scientists around the world.
[4]
oai:arXiv.org:1710.05299 [pdf] - 1648653
Initial Performance of the COSINE-100 Experiment
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W. Q.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W.;
Kang, W. G.;
Kauer, M.;
Kim, B. H.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, M. C.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lim, K. E.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Pierpoint, Z. P.;
Prihtiadi, H.;
Ra, S.;
Rogers, F. R.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yong, S. H.
Submitted: 2017-10-15, last modified: 2018-02-11
COSINE is a dark matter search experiment based on an array of low background
NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly
of COSINE-100 was completed in the summer of 2016 and the detector is currently
collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment
that reported an annual modulation signal. Stable operation has been achieved
and will continue for at least two years. Here, we describe the design of
COSINE-100, including the shielding arrangement, the configuration of the
NaI(Tl) crystal detection elements, the veto systems, and the associated
operational systems, and we show the current performance of the experiment.
[5]
oai:arXiv.org:1712.02011 [pdf] - 1648729
Muon detector for the COSINE-100 experiment
Collaboration, COSINE-100;
:;
Prihtiadi, H.;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W. Q.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W.;
Kang, W. G.;
Kauer, M.;
Kim, B. H.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lim, K. E.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Pierpoint, Z. P.;
Ra, S.;
Rogers, F. R.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yong, S. H.
Submitted: 2017-12-05
The COSINE-100 dark matter search experiment has started taking physics data
with the goal of performing an independent measurement of the annual modulation
signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic
scintillator panels in the outermost layer of the shield surrounding the
COSINE-100 detector. It is used to detect cosmic ray muons in order to
understand the impact of the muon annual modulation on dark matter analysis.
Assembly and initial performance test of each module have been performed at a
ground laboratory. The installation of the detector in Yangyang Underground
Laboratory (Y2L) was completed in the summer of 2016. Using three months of
data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$
10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector
and the results from the analysis are presented.
[6]
oai:arXiv.org:1705.06766 [pdf] - 1634075
The Hyper Suprime-Cam Software Pipeline
Bosch, James;
Armstrong, Robert;
Bickerton, Steven;
Furusawa, Hisanori;
Ikeda, Hiroyuki;
Koike, Michitaro;
Lupton, Robert;
Mineo, Sogo;
Price, Paul;
Takata, Tadafumi;
Tanaka, Masayuki;
Yasuda, Naoki;
AlSayyad, Yusra;
Becker, Andrew C.;
Coulton, William;
Coupon, Jean;
Garmilla, Jose;
Huang, Song;
Krughoff, K. Simon;
Lang, Dustin;
Leauthaud, Alexie;
Lim, Kian-Tat;
Lust, Nate B.;
MacArthur, Lauren A.;
Mandelbaum, Rachel;
Miyatake, Hironao;
Miyazaki, Satoshi;
Murata, Ryoma;
More, Surhud;
Okura, Yuki;
Owen, Russell;
Swinbank, John D.;
Strauss, Michael A.;
Yamada, Yoshihiko;
Yamanoi, Hitomi
Submitted: 2017-05-18
In this paper, we describe the optical imaging data processing pipeline
developed for the Subaru Telescope's Hyper Suprime-Cam (HSC) instrument. The
HSC Pipeline builds on the prototype pipeline being developed by the Large
Synoptic Survey Telescope's Data Management system, adding customizations for
HSC, large-scale processing capabilities, and novel algorithms that have since
been reincorporated into the LSST codebase. While designed primarily to reduce
HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline
for reducing general-observer HSC data. The HSC pipeline includes high level
processing steps that generate coadded images and science-ready catalogs as
well as low-level detrending and image characterizations.
[7]
oai:arXiv.org:1602.05939 [pdf] - 1538892
First search for a dark matter annual modulation signal with NaI(Tl) in
the Southern Hemisphere by DM-Ice17
Collaboration, DM-Ice;
:;
de Souza, E. Barbosa;
Cherwinka, J.;
Cole, A.;
Ezeribe, A. C.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Jo, J. H.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Mouton, F.;
Paling, S. M.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Rogers, F. R.;
Sandstrom, P.;
Scarff, A.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2016-02-18, last modified: 2017-02-28
We present the first search for a dark matter annual modulation signal in the
Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17
experiment. Nuclear recoils from dark matter interactions are expected to yield
an annually modulated signal independent of location within the Earth's
hemispheres. DM-Ice17, the first step in the DM-Ice experimental program,
consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e.
overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure
of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy
range of 4-20 keV, providing the strongest limits on weakly interacting massive
particle dark matter from a direct detection experiment located in the Southern
Hemisphere. The successful deployment and stable long-term operation of
DM-Ice17 establishes the South Pole ice as a viable location for future dark
matter searches and in particular for a high-sensitivity NaI(Tl) dark matter
experiment to directly test the DAMA/LIBRA claim of the observation of dark
matter.
[8]
oai:arXiv.org:1509.02486 [pdf] - 1364880
Measurement of Muon Annual Modulation and Muon-Induced Phosphorescence
in NaI(Tl) Crystals with DM-Ice17
Collaboration, DM-Ice;
:;
Cherwinka, J.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Paling, S.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Sandstrom, P.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2015-09-08, last modified: 2016-02-25
We report the measurement of muons and muon-induced phosphorescence in
DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole.
Muon interactions in the crystal are identified by their observed pulse shape
and large energy depositions. The measured muon rate in DM-Ice17 is 2.93 +/-
0.04 muons/crystal/day with a modulation amplitude of 12.3 +/- 1.7%, consistent
with expectation. Following muon interactions, we observe long-lived
phosphorescence in the NaI(Tl) crystals with a decay time of 5.5 +/- 0.5 s. The
prompt energy deposited by a muon is correlated to the amount of delayed
phosphorescence, the brightest of which consist of tens of millions of photons.
These photons are distributed over tens of seconds with a rate and arrival
timing that do not mimic a scintillation signal above 2 keVee. While the
properties of phosphorescence vary among individual crystals, the
annually-modulating signal observed by DAMA cannot be accounted for by
phosphorescence with the characteristics observed in DM-Ice17.
[9]
oai:arXiv.org:1512.07914 [pdf] - 1938162
The LSST Data Management System
Jurić, Mario;
Kantor, Jeffrey;
Lim, K-T;
Lupton, Robert H.;
Dubois-Felsmann, Gregory;
Jenness, Tim;
Axelrod, Tim S.;
Aleksić, Jovan;
Allsman, Roberta A.;
AlSayyad, Yusra;
Alt, Jason;
Armstrong, Robert;
Basney, Jim;
Becker, Andrew C.;
Becla, Jacek;
Bickerton, Steven J.;
Biswas, Rahul;
Bosch, James;
Boutigny, Dominique;
Kind, Matias Carrasco;
Ciardi, David R.;
Connolly, Andrew J.;
Daniel, Scott F.;
Daues, Gregory E.;
Economou, Frossie;
Chiang, Hsin-Fang;
Fausti, Angelo;
Fisher-Levine, Merlin;
Freemon, D. Michael;
Gee, Perry;
Gris, Philippe;
Hernandez, Fabio;
Hoblitt, Joshua;
Ivezić, Željko;
Jammes, Fabrice;
Jevremović, Darko;
Jones, R. Lynne;
Kalmbach, J. Bryce;
Kasliwal, Vishal P.;
Krughoff, K. Simon;
Lang, Dustin;
Lurie, John;
Lust, Nate B.;
Mullally, Fergal;
MacArthur, Lauren A.;
Melchior, Peter;
Moeyens, Joachim;
Nidever, David L.;
Owen, Russell;
Parejko, John K;
Peterson, J. Matt;
Petravick, Donald;
Pietrowicz, Stephen R.;
Price, Paul A.;
Reiss, David J.;
Shaw, Richard A.;
Sick, Jonathan;
Slater, Colin T.;
Strauss, Michael A.;
Sullivan, Ian S.;
Swinbank, John D.;
Van Dyk, Schuyler;
Vujčić, Veljko;
Withers, Alexander;
Yoachim, Peter
Submitted: 2015-12-24
The Large Synoptic Survey Telescope (LSST) is a large-aperture, wide-field,
ground-based survey system that will image the sky in six optical bands from
320 to 1050 nm, uniformly covering approximately $18,000$deg$^2$ of the sky
over 800 times. The LSST is currently under construction on Cerro Pach\'on in
Chile, and expected to enter operations in 2022. Once operational, the LSST
will explore a wide range of astrophysical questions, from discovering "killer"
asteroids to examining the nature of Dark Energy.
The LSST will generate on average 15 TB of data per night, and will require a
comprehensive Data Management system to reduce the raw data to scientifically
useful catalogs and images with minimum human intervention. These reductions
will result in a real-time alert stream, and eleven data releases over the
10-year duration of LSST operations. To enable this processing, the LSST
project is developing a new, general-purpose, high-performance, scalable, well
documented, open source data processing software stack for O/IR surveys.
Prototypes of this stack are already capable of processing data from existing
cameras (e.g., SDSS, DECam, MegaCam), and form the basis of the Hyper-Suprime
Cam (HSC) Survey data reduction pipeline.
[10]
oai:arXiv.org:1405.1052 [pdf] - 1209364
Gamma-ray Line from Nambu-Goldstone Dark Matter in a Scale Invariant
Extension of the Standard Model
Submitted: 2014-05-05, last modified: 2014-08-13
A recently proposed scale invariant extension of the standard model is
modified such that it includes a Dark Matter candidate which can annihilate
into gamma-rays. For that a non-zero $U(1)_Y$ hypercharge $Q$ is assigned to
the fermions in a QCD-like hidden sector. The Nambu-Goldstone bosons, that
arise due to dynamical chiral symmetry breaking in the hidden sector, are cold
Dark Matter candidates, and the extension allows them to annihilate into two
photons, producing a gamma-ray line spectrum. We find that the gamma-ray line
energy must be between 0.7 TeV and 0.9 TeV with the velocity-averaged
annihilation cross section $10^{-30}\sim 10^{-26}$ cm^3/s for $Q=1/3$. With a
non-zero hypercharge $Q$, the hidden sector is no longer completely dark and
can be directly probed by collider experiments.
[11]
oai:arXiv.org:1311.1088 [pdf] - 783783
Observation and applications of single-electron charge signals in the
XENON100 experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection
chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of
dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we
report the observation of single-electron charge signals which are not related
to WIMP interactions. These signals, which show the excellent sensitivity of
the detector to small charge signals, are explained as being due to the
photoionization of impurities in the liquid xenon and of the metal components
inside the TPC. They are used as a unique calibration source to characterize
the detector. We explain how we can infer crucial parameters for the XENON100
experiment: the secondary-scintillation gain, the extraction yield from the
liquid to the gas phase and the electron drift velocity.
[12]
oai:arXiv.org:1207.3458 [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D. B.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso,
aims at the direct detection of dark matter in the form of weakly interacting
massive particles (WIMPs), based on their interactions with xenon nuclei in an
ultra low background dual-phase time projection chamber. This paper describes
the general methods developed for the analysis of the XENON100 data. These
methods have been used in the 100.9 and 224.6 live days science runs from which
results on spin-independent elastic, spin-dependent elastic and inelastic
WIMP-nucleon cross-sections have already been reported.
[13]
oai:arXiv.org:1306.2303 [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
ScottoLavina, L.;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali
del Gran Sasso (LNGS), aims to directly detect dark matter in the form of
Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off
xenon nuclei. This paper presents a study on the nuclear recoil background of
the experiment, taking into account neutron backgrounds from ($\alpha$,n) and
spontaneous fission reactions due to natural radioactivity in the detector and
shield materials, as well as muon-induced neutrons. Based on Monte Carlo
simulations and using measured radioactive contaminations of all detector
components, we predict the nuclear recoil backgrounds for the WIMP search
results published by the XENON100 experiment in 2011 and 2012,
0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively,
and conclude that they do not limit the sensitivity of the experiment.
[14]
oai:arXiv.org:1304.1427 [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Schuhmacher, H.;
Wiegel, B.
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter
detector installed underground at the Laboratori Nazionali del Gran Sasso
(LNGS), Italy are presented. Data from measurements with an external 241AmBe
neutron source are compared with a detailed Monte Carlo simulation which is
used to extract the energy dependent charge-yield Qy and relative scintillation
efficiency Leff. A very good level of absolute spectral matching is achieved in
both observable signal channels - scintillation S1 and ionization S2 - along
with agreement in the 2-dimensional particle discrimination space. The results
confirm the validity of the derived signal acceptance in earlier reported dark
matter searches of the XENON100 experiment.
[15]
oai:arXiv.org:1207.5988 [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kettling, H.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment,
operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during
2011 and 2012. XENON100 features an ultra-low electromagnetic background of
(5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of
interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded
no evidence for dark matter interactions. The two candidate events observed in
the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent
with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood
analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on
the spin-independent elastic WIMP-nucleon scattering cross section for WIMP
masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2
and 90% confidence level.
[16]
oai:arXiv.org:1101.3866 [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso
(LNGS), aims to directly detect dark matter in the form of Weakly Interacting
Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We
present a comprehensive study of the predicted electronic recoil background
coming from radioactive decays inside the detector and shield materials, and
intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a
detailed geometry together with the measured radioactivity of all detector
components, we predict an electronic recoil background in the WIMP-search
energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2
events/(kg-day-keV), consistent with the experiment's design goal. The
predicted background spectrum is in very good agreement with the data taken
during the commissioning of the detector, in Fall 2009.
[17]
oai:arXiv.org:1301.6620 [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days
of XENON100 data
XENON100 collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent
WIMP-nucleon cross section using recent data from the XENON100 experiment,
operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of
224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no
excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe
nuclei. This leads to the most stringent upper limits on WIMP-neutron cross
sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x
10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[18]
oai:arXiv.org:1211.0836 [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G. M.;
Budnik, R.;
Calloch, M. Le;
Cardoso, J. M.;
Chen, W. -T.;
Choi, B.;
Contreras, H.;
Cussonneau, J. -P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L.;
Grignon, C.;
Gross, E.;
Hampel, W.;
McKinsey, D. N.;
Kish, A.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Manzur, A.;
Undagoitia, T. Marrodán;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Patricio, J. V.;
Persiani, R.;
Plante, G.;
Priel, N.;
Ribeiro, A. C. C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso (LNGS) in Italy, was designed to search for evidence of dark matter
interactions inside a volume of liquid xenon using a dual-phase time projection
chamber. This paper describes the Slow Control System (SCS) of the experiment
with emphasis on the distributed architecture as well as on its modular and
expandable nature. The system software was designed according to the rules of
Object-Oriented Programming and coded in Java, thus promoting code reusability
and maximum flexibility during commissioning of the experiment. The SCS has
been continuously monitoring the XENON100 detector since mid 2008, remotely
recording hundreds of parameters on a few dozen instruments in real time, and
setting emergency alarms for the most important variables.
[19]
oai:arXiv.org:1209.3658 [pdf] - 673149
Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid
Xenon
Aprile, E.;
Budnik, R.;
Choi, B.;
Contreras, H. A.;
Giboni, K. -L.;
Goetzke, L. W.;
Koglin, J. E.;
Lang, R. F.;
Lim, K. E.;
Fernandez, A. J. Melgarejo;
Persiani, R.;
Plante, G.;
Rizzo, A.
Submitted: 2012-09-17
We have measured the energy dependence of the liquid xenon (LXe)
scintillation yield of electrons with energy between 2.1 and 120.2keV, using
the Compton coincidence technique. A LXe scintillation detector with a very
high light detection efficiency was irradiated with 137Cs {\gamma} rays and the
energy of the Compton-scattered {\gamma} rays was measured with a high-purity
germanium (HPGe) detector placed at different scattering angles. The excellent
energy resolution of the HPGe detector allows the selection of events with
Compton electrons of known energy in the LXe detector. We find that the
scintillation yield initially increases as the electron energy decreases from
120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The
measured scintillation yield was also measured with conversion electrons from
the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal
calibration source. We find that the scintillation yield of the 32.1 keV
transition is compatible with that obtained from the Compton coincidence
measurement. On the other hand, the yield for the 9.4keV transition is much
higher than that measured for a Compton electron of the same energy. We
interpret the enhancement in the scintillation yield as due to the enhanced
recombination rate in the presence of Xe ions left from the 32.1 keV
transition, which precedes the 9.4 keV one by 220 ns, on average.
[20]
oai:arXiv.org:1208.5762 [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid
xenon detectors"
The XENON Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.
[21]
oai:arXiv.org:1207.5432 [pdf] - 1125033
Measurement of the Quantum Efficiency of Hamamatsu R8520
Photomultipliers at Liquid Xenon Temperature
Aprile, E.;
Beck, M.;
Bokeloh, K.;
Budnik, R.;
Choi, B.;
Contreras, H. A.;
Giboni, K. -L.;
Goetzke, L. W.;
Lang, R. F.;
Lim, K. E.;
Fernandez, A. J. Melgarejo;
Plante, G.;
Rizzo, A.;
Shagin, P.;
Weinheimer, C.
Submitted: 2012-07-23
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to
liquid xenon are being used to efficiently detect the 178 nm scintillation
light in a variety of liquid xenon based particle detectors. Good knowledge of
the performance of these photomultipliers under cryogenic conditions is needed
to properly characterize these detectors. Here, we report on measurements of
the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON
Dark Matter Experiments. The quantum efficiency measurements at room
temperature agree with the values provided by Hamamatsu. At low temperatures,
between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative
to the room temperature values.
[22]
oai:arXiv.org:1107.2155 [pdf] - 474250
The XENON100 Dark Matter Experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. L.;
Kish, A.;
Lam, C. W.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Tziaferi, E.;
Wang, H.;
Yamashita, M.
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[23]
oai:arXiv.org:1104.3121 [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100
Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
[24]
oai:arXiv.org:1104.2549 [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.
[25]
oai:arXiv.org:1103.0303 [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to
distinguish a dominant background from the expected feeble signals, based on
some measured discrimination parameter. We develop a statistical model for such
experiments using the Profile Likelihood ratio as a test statistic in a
frequentist approach. We take data from calibrations as control measurements
for signal and background, and the method allows the inclusion of data from
Monte Carlo simulations. Systematic detector uncertainties, such as
uncertainties in the energy scale, as well as astrophysical uncertainties, are
included in the model. The statistical model can be used to either set an
exclusion limit or to make a discovery claim, and the results are derived with
a proper treatment of statistical and systematic uncertainties. We apply the
model to the first data release of the XENON100 experiment, which allows to
extract additional information from the data, and place stronger limits on the
spin-independent elastic WIMP-nucleon scattering cross-section. In particular,
we derive a single limit, including all relevant systematic uncertainties, with
a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[26]
oai:arXiv.org:1104.2587 [pdf] - 669518
New Measurement of the Scintillation Efficiency of Low-Energy Nuclear
Recoils in Liquid Xenon
Submitted: 2011-04-13
Particle detectors that use liquid xenon (LXe) as detection medium are among
the leading technologies in the search for dark matter weakly interacting
massive particles (WIMPs). A key enabling element has been the low-energy
detection threshold for recoiling nuclei produced by the interaction of WIMPs
in LXe targets. In these detectors, the nuclear recoil energy scale is based on
the LXe scintillation signal and thus requires knowledge of the relative
scintillation efficiency of nuclear recoils, Leff. The uncertainty in Leff at
low energies is the largest systematic uncertainty in the reported results from
LXe WIMP searches at low masses. In the context of the XENON Dark Matter
project, a new LXe scintillation detector has been designed and built
specifically for the measurement of Leff at low energies, with an emphasis on
maximizing the scintillation light detection efficiency to obtain the lowest
possible energy threshold. We report new measurements of Leff at low energies
performed with this detector. Our results suggest a Leff which slowly decreases
with energy, from 0.144 +/- 0.009 at 15 keV down to 0.088 +0.014 -0.015 at 3
keV.
[27]
oai:arXiv.org:1005.0380 [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D. B.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Hugenberg, K.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weinheimer, C.
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.
[28]
oai:arXiv.org:0810.0274 [pdf] - 166670
New Measurement of the Relative Scintillation Efficiency of Xenon
Nuclear Recoils Below 10 keV
Aprile, E.;
Baudis, L.;
Choi, B.;
Giboni, K. L.;
Lim, K. E.;
Manalaysay, A.;
Monzani, M. E.;
Plante, G.;
Santorelli, R.;
Yamashita, M.
Submitted: 2008-10-01, last modified: 2010-05-16
Liquid xenon is an important detection medium in direct dark matter
experiments, which search for low-energy nuclear recoils produced by the
elastic scattering of WIMPs with quarks. The two existing measurements of the
relative scintillation efficiency of nuclear recoils below 20 keV lead to
inconsistent extrapolations at lower energies. This results in a different
energy scale and thus sensitivity reach of liquid xenon dark matter detectors.
We report a new measurement of the relative scintillation efficiency below 10
keV performed with a liquid xenon scintillation detector, optimized for maximum
light collection. Greater than 95% of the interior surface of this detector was
instrumented with photomultiplier tubes, giving a scintillation yield of 19.6
photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the
relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying
constant around this value up to 10 keV. For higher energy recoils we measure a
value around 20%, consistent with previously reported data. In light of this
new measurement, the XENON10 experiment's results on spin-independent
WIMP-nucleon cross section, which were calculated assuming a constant 0.19
relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to
$9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from
$4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30
GeV/c$^2$.
[29]
oai:arXiv.org:0912.2405 [pdf] - 1018742
Self-shielding effect of a single phase liquid xenon detector for direct
dark matter search
Minamino, A.;
Abe, K.;
Ashie, Y.;
Hosaka, J.;
Ishihara, K.;
Kobayashi, K.;
Koshio, Y.;
Mitsuda, C.;
Moriyama, S.;
Nakahata, M.;
Nakajima, Y.;
Namba, T.;
Ogawa, H.;
Sekiya, H.;
Shiozawa, M.;
Suzuki, Y.;
Takeda, A.;
Takeuchi, Y.;
Taki, K.;
Ueshima, K.;
Ebizuka, Y.;
Ota, A.;
Suzuki, S.;
Hagiwara, H.;
Hashimoto, Y.;
Kamada, S.;
Kikuchi, M.;
Kobayashi, N.;
Nagase, T.;
Nakamura, S.;
Tomita, K.;
Uchida, Y.;
Fukuda, Y.;
Sato, T.;
Nishijima, K.;
Maruyama, T.;
Motoki, D.;
Itow, Y.;
Kim, Y. D.;
Lee, J. I.;
Moon, S. H.;
Lim, K. E.;
Cravens, J. P;
Smy, M. B.
Submitted: 2009-12-12
Liquid xenon is a suitable material for a dark matter search. For future
large scale experiments, single phase detectors are attractive due to their
simple configuration and scalability. However, in order to reduce backgrounds,
they need to fully rely on liquid xenon's self-shielding property. A prototype
detector was developed at Kamioka Observatory to establish vertex and energy
reconstruction methods and to demonstrate the self-shielding power against
gamma rays from outside of the detector. Sufficient self-shielding power for
future experiments was obtained.