sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Lim, K. E.

Normalized to: Lim, K.

29 article(s) in total. 561 co-authors, from 1 to 18 common article(s). Median position in authors list is 27,0.

[1]  oai:arXiv.org:1812.08085  [pdf] - 1801453
Abstracting the storage and retrieval of image data at the LSST
Comments: 4 pages, 1 figure, submitted to proceedings of ADASS XXVIII to be published in ASP Conf. Series
Submitted: 2018-12-19
Writing generic data processing pipelines requires that the algorithmic code does not ever have to know about data formats of files, or the locations of those files. At LSST we have a software system known as "the Data Butler," that abstracts these details from the software developer. Scientists can specify the dataset they want in terms they understand, such as filter, observation identifier, date of observation, and instrument name, and the Butler translates that to one or more files which are read and returned to them as a single Python object. Conversely, once they have created a new dataset they can give it back to the Butler, with a label describing its new status, and the Butler can write it in whatever format it has been configured to use. All configuration is in YAML and supports standard defaults whilst allowing overrides.
[2]  oai:arXiv.org:1806.09788  [pdf] - 1764379
The COSINE-100 Data Acquisition System
Comments:
Submitted: 2018-06-26
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
[3]  oai:arXiv.org:0805.2366  [pdf] - 1934226
LSST: from Science Drivers to Reference Design and Anticipated Data Products
Ivezić, Željko; Kahn, Steven M.; Tyson, J. Anthony; Abel, Bob; Acosta, Emily; Allsman, Robyn; Alonso, David; AlSayyad, Yusra; Anderson, Scott F.; Andrew, John; Angel, James Roger P.; Angeli, George Z.; Ansari, Reza; Antilogus, Pierre; Araujo, Constanza; Armstrong, Robert; Arndt, Kirk T.; Astier, Pierre; Aubourg, Éric; Auza, Nicole; Axelrod, Tim S.; Bard, Deborah J.; Barr, Jeff D.; Barrau, Aurelian; Bartlett, James G.; Bauer, Amanda E.; Bauman, Brian J.; Baumont, Sylvain; Becker, Andrew C.; Becla, Jacek; Beldica, Cristina; Bellavia, Steve; Bianco, Federica B.; Biswas, Rahul; Blanc, Guillaume; Blazek, Jonathan; Blandford, Roger D.; Bloom, Josh S.; Bogart, Joanne; Bond, Tim W.; Borgland, Anders W.; Borne, Kirk; Bosch, James F.; Boutigny, Dominique; Brackett, Craig A.; Bradshaw, Andrew; Brandt, William Nielsen; Brown, Michael E.; Bullock, James S.; Burchat, Patricia; Burke, David L.; Cagnoli, Gianpietro; Calabrese, Daniel; Callahan, Shawn; Callen, Alice L.; Chandrasekharan, Srinivasan; Charles-Emerson, Glenaver; Chesley, Steve; Cheu, Elliott C.; Chiang, Hsin-Fang; Chiang, James; Chirino, Carol; Chow, Derek; Ciardi, David R.; Claver, Charles F.; Cohen-Tanugi, Johann; Cockrum, Joseph J.; Coles, Rebecca; Connolly, Andrew J.; Cook, Kem H.; Cooray, Asantha; Covey, Kevin R.; Cribbs, Chris; Cui, Wei; Cutri, Roc; Daly, Philip N.; Daniel, Scott F.; Daruich, Felipe; Daubard, Guillaume; Daues, Greg; Dawson, William; Delgado, Francisco; Dellapenna, Alfred; de Peyster, Robert; de Val-Borro, Miguel; Digel, Seth W.; Doherty, Peter; Dubois, Richard; Dubois-Felsmann, Gregory P.; Durech, Josef; Economou, Frossie; Eracleous, Michael; Ferguson, Henry; Figueroa, Enrique; Fisher-Levine, Merlin; Focke, Warren; Foss, Michael D.; Frank, James; Freemon, Michael D.; Gangler, Emmanuel; Gawiser, Eric; Geary, John C.; Gee, Perry; Geha, Marla; Gessner, Charles J. B.; Gibson, Robert R.; Gilmore, D. Kirk; Glanzman, Thomas; Glick, William; Goldina, Tatiana; Goldstein, Daniel A.; Goodenow, Iain; Graham, Melissa L.; Gressler, William J.; Gris, Philippe; Guy, Leanne P.; Guyonnet, Augustin; Haller, Gunther; Harris, Ron; Hascall, Patrick A.; Haupt, Justine; Hernandez, Fabio; Herrmann, Sven; Hileman, Edward; Hoblitt, Joshua; Hodgson, John A.; Hogan, Craig; Huang, Dajun; Huffer, Michael E.; Ingraham, Patrick; Innes, Walter R.; Jacoby, Suzanne H.; Jain, Bhuvnesh; Jammes, Fabrice; Jee, James; Jenness, Tim; Jernigan, Garrett; Jevremović, Darko; Johns, Kenneth; Johnson, Anthony S.; Johnson, Margaret W. G.; Jones, R. Lynne; Juramy-Gilles, Claire; Jurić, Mario; Kalirai, Jason S.; Kallivayalil, Nitya J.; Kalmbach, Bryce; Kantor, Jeffrey P.; Karst, Pierre; Kasliwal, Mansi M.; Kelly, Heather; Kessler, Richard; Kinnison, Veronica; Kirkby, David; Knox, Lloyd; Kotov, Ivan V.; Krabbendam, Victor L.; Krughoff, K. Simon; Kubánek, Petr; Kuczewski, John; Kulkarni, Shri; Ku, John; Kurita, Nadine R.; Lage, Craig S.; Lambert, Ron; Lange, Travis; Langton, J. Brian; Guillou, Laurent Le; Levine, Deborah; Liang, Ming; Lim, Kian-Tat; Lintott, Chris J.; Long, Kevin E.; Lopez, Margaux; Lotz, Paul J.; Lupton, Robert H.; Lust, Nate B.; MacArthur, Lauren A.; Mahabal, Ashish; Mandelbaum, Rachel; Marsh, Darren S.; Marshall, Philip J.; Marshall, Stuart; May, Morgan; McKercher, Robert; McQueen, Michelle; Meyers, Joshua; Migliore, Myriam; Miller, Michelle; Mills, David J.; Miraval, Connor; Moeyens, Joachim; Monet, David G.; Moniez, Marc; Monkewitz, Serge; Montgomery, Christopher; Mueller, Fritz; Muller, Gary P.; Arancibia, Freddy Muñoz; Neill, Douglas R.; Newbry, Scott P.; Nief, Jean-Yves; Nomerotski, Andrei; Nordby, Martin; O'Connor, Paul; Oliver, John; Olivier, Scot S.; Olsen, Knut; O'Mullane, William; Ortiz, Sandra; Osier, Shawn; Owen, Russell E.; Pain, Reynald; Palecek, Paul E.; Parejko, John K.; Parsons, James B.; Pease, Nathan M.; Peterson, J. Matt; Peterson, John R.; Petravick, Donald L.; Petrick, M. E. Libby; Petry, Cathy E.; Pierfederici, Francesco; Pietrowicz, Stephen; Pike, Rob; Pinto, Philip A.; Plante, Raymond; Plate, Stephen; Price, Paul A.; Prouza, Michael; Radeka, Veljko; Rajagopal, Jayadev; Rasmussen, Andrew P.; Regnault, Nicolas; Reil, Kevin A.; Reiss, David J.; Reuter, Michael A.; Ridgway, Stephen T.; Riot, Vincent J.; Ritz, Steve; Robinson, Sean; Roby, William; Roodman, Aaron; Rosing, Wayne; Roucelle, Cecille; Rumore, Matthew R.; Russo, Stefano; Saha, Abhijit; Sassolas, Benoit; Schalk, Terry L.; Schellart, Pim; Schindler, Rafe H.; Schmidt, Samuel; Schneider, Donald P.; Schneider, Michael D.; Schoening, William; Schumacher, German; Schwamb, Megan E.; Sebag, Jacques; Selvy, Brian; Sembroski, Glenn H.; Seppala, Lynn G.; Serio, Andrew; Serrano, Eduardo; Shaw, Richard A.; Shipsey, Ian; Sick, Jonathan; Silvestri, Nicole; Slater, Colin T.; Smith, J. Allyn; Smith, R. Chris; Sobhani, Shahram; Soldahl, Christine; Storrie-Lombardi, Lisa; Stover, Edward; Strauss, Michael A.; Street, Rachel A.; Stubbs, Christopher W.; Sullivan, Ian S.; Sweeney, Donald; Swinbank, John D.; Szalay, Alexander; Takacs, Peter; Tether, Stephen A.; Thaler, Jon J.; Thayer, John Gregg; Thomas, Sandrine; Thukral, Vaikunth; Tice, Jeffrey; Trilling, David E.; Turri, Max; Van Berg, Richard; Berk, Daniel Vanden; Vetter, Kurt; Virieux, Francoise; Vucina, Tomislav; Wahl, William; Walkowicz, Lucianne; Walsh, Brian; Walter, Christopher W.; Wang, Daniel L.; Wang, Shin-Yawn; Warner, Michael; Wiecha, Oliver; Willman, Beth; Winters, Scott E.; Wittman, David; Wolff, Sidney C.; Wood-Vasey, W. Michael; Wu, Xiuqin; Xin, Bo; Yoachim, Peter; Zhan, Hu
Comments: 57 pages, 32 color figures, version with high-resolution figures available from https://www.lsst.org/overview
Submitted: 2008-05-15, last modified: 2018-05-23
(Abridged) We describe here the most ambitious survey currently planned in the optical, the Large Synoptic Survey Telescope (LSST). A vast array of science will be enabled by a single wide-deep-fast sky survey, and LSST will have unique survey capability in the faint time domain. The LSST design is driven by four main science themes: probing dark energy and dark matter, taking an inventory of the Solar System, exploring the transient optical sky, and mapping the Milky Way. LSST will be a wide-field ground-based system sited at Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg$^2$ field of view, and a 3.2 Gigapixel camera. The standard observing sequence will consist of pairs of 15-second exposures in a given field, with two such visits in each pointing in a given night. With these repeats, the LSST system is capable of imaging about 10,000 square degrees of sky in a single filter in three nights. The typical 5$\sigma$ point-source depth in a single visit in $r$ will be $\sim 24.5$ (AB). The project is in the construction phase and will begin regular survey operations by 2022. The survey area will be contained within 30,000 deg$^2$ with $\delta<+34.5^\circ$, and will be imaged multiple times in six bands, $ugrizy$, covering the wavelength range 320--1050 nm. About 90\% of the observing time will be devoted to a deep-wide-fast survey mode which will uniformly observe a 18,000 deg$^2$ region about 800 times (summed over all six bands) during the anticipated 10 years of operations, and yield a coadded map to $r\sim27.5$. The remaining 10\% of the observing time will be allocated to projects such as a Very Deep and Fast time domain survey. The goal is to make LSST data products, including a relational database of about 32 trillion observations of 40 billion objects, available to the public and scientists around the world.
[4]  oai:arXiv.org:1710.05299  [pdf] - 1648653
Initial Performance of the COSINE-100 Experiment
Comments: 19 pages, 25 figures, EPJC accepted
Submitted: 2017-10-15, last modified: 2018-02-11
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least two years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.
[5]  oai:arXiv.org:1712.02011  [pdf] - 1648729
Muon detector for the COSINE-100 experiment
Comments: 11 pages, 19 figures
Submitted: 2017-12-05
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.
[6]  oai:arXiv.org:1705.06766  [pdf] - 1634075
The Hyper Suprime-Cam Software Pipeline
Comments: 39 pages, 21 figures, 2 tables. Submitted to Publications of the Astronomical Society of Japan
Submitted: 2017-05-18
In this paper, we describe the optical imaging data processing pipeline developed for the Subaru Telescope's Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope's Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high level processing steps that generate coadded images and science-ready catalogs as well as low-level detrending and image characterizations.
[7]  oai:arXiv.org:1602.05939  [pdf] - 1538892
First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17
Comments: 6 pages, 5 figures, revised version as published in PRD
Submitted: 2016-02-18, last modified: 2017-02-28
We present the first search for a dark matter annual modulation signal in the Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17 experiment. Nuclear recoils from dark matter interactions are expected to yield an annually modulated signal independent of location within the Earth's hemispheres. DM-Ice17, the first step in the DM-Ice experimental program, consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e. overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy range of 4-20 keV, providing the strongest limits on weakly interacting massive particle dark matter from a direct detection experiment located in the Southern Hemisphere. The successful deployment and stable long-term operation of DM-Ice17 establishes the South Pole ice as a viable location for future dark matter searches and in particular for a high-sensitivity NaI(Tl) dark matter experiment to directly test the DAMA/LIBRA claim of the observation of dark matter.
[8]  oai:arXiv.org:1509.02486  [pdf] - 1364880
Measurement of Muon Annual Modulation and Muon-Induced Phosphorescence in NaI(Tl) Crystals with DM-Ice17
Comments: 9 pages, 8 figures
Submitted: 2015-09-08, last modified: 2016-02-25
We report the measurement of muons and muon-induced phosphorescence in DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole. Muon interactions in the crystal are identified by their observed pulse shape and large energy depositions. The measured muon rate in DM-Ice17 is 2.93 +/- 0.04 muons/crystal/day with a modulation amplitude of 12.3 +/- 1.7%, consistent with expectation. Following muon interactions, we observe long-lived phosphorescence in the NaI(Tl) crystals with a decay time of 5.5 +/- 0.5 s. The prompt energy deposited by a muon is correlated to the amount of delayed phosphorescence, the brightest of which consist of tens of millions of photons. These photons are distributed over tens of seconds with a rate and arrival timing that do not mimic a scintillation signal above 2 keVee. While the properties of phosphorescence vary among individual crystals, the annually-modulating signal observed by DAMA cannot be accounted for by phosphorescence with the characteristics observed in DM-Ice17.
[9]  oai:arXiv.org:1512.07914  [pdf] - 1938162
The LSST Data Management System
Comments: 10 pages, 3 figures, to appear in the Proceedings of ADASS XXV
Submitted: 2015-12-24
The Large Synoptic Survey Telescope (LSST) is a large-aperture, wide-field, ground-based survey system that will image the sky in six optical bands from 320 to 1050 nm, uniformly covering approximately $18,000$deg$^2$ of the sky over 800 times. The LSST is currently under construction on Cerro Pach\'on in Chile, and expected to enter operations in 2022. Once operational, the LSST will explore a wide range of astrophysical questions, from discovering "killer" asteroids to examining the nature of Dark Energy. The LSST will generate on average 15 TB of data per night, and will require a comprehensive Data Management system to reduce the raw data to scientifically useful catalogs and images with minimum human intervention. These reductions will result in a real-time alert stream, and eleven data releases over the 10-year duration of LSST operations. To enable this processing, the LSST project is developing a new, general-purpose, high-performance, scalable, well documented, open source data processing software stack for O/IR surveys. Prototypes of this stack are already capable of processing data from existing cameras (e.g., SDSS, DECam, MegaCam), and form the basis of the Hyper-Suprime Cam (HSC) Survey data reduction pipeline.
[10]  oai:arXiv.org:1405.1052  [pdf] - 1209364
Gamma-ray Line from Nambu-Goldstone Dark Matter in a Scale Invariant Extension of the Standard Model
Comments: 21 Pages, 8 Figures. Typos corrected, references added, the section about the properties of the dark matter in our model is extended. Result and conclusion unchanged. To appear in JHEP
Submitted: 2014-05-05, last modified: 2014-08-13
A recently proposed scale invariant extension of the standard model is modified such that it includes a Dark Matter candidate which can annihilate into gamma-rays. For that a non-zero $U(1)_Y$ hypercharge $Q$ is assigned to the fermions in a QCD-like hidden sector. The Nambu-Goldstone bosons, that arise due to dynamical chiral symmetry breaking in the hidden sector, are cold Dark Matter candidates, and the extension allows them to annihilate into two photons, producing a gamma-ray line spectrum. We find that the gamma-ray line energy must be between 0.7 TeV and 0.9 TeV with the velocity-averaged annihilation cross section $10^{-30}\sim 10^{-26}$ cm^3/s for $Q=1/3$. With a non-zero hypercharge $Q$, the hidden sector is no longer completely dark and can be directly probed by collider experiments.
[11]  oai:arXiv.org:1311.1088  [pdf] - 783783
Observation and applications of single-electron charge signals in the XENON100 experiment
Comments: 16 pages, 8 figures. Accepted for publication in Journal of Physics G: Nuclear and Particle Physics
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
[12]  oai:arXiv.org:1207.3458  [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
Comments: 18 pages, 17 figures, information for the 224.6 live days run included
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
[13]  oai:arXiv.org:1306.2303  [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Comments:
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($\alpha$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
[14]  oai:arXiv.org:1304.1427  [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Comments: 10 pages, 10 figures. Matches version accepted by PRD. Contains revised representation of expected WIMP event signature. Conclusions remain unaffected
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
[15]  oai:arXiv.org:1207.5988  [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
Comments: 6 pages, 5 figures. Matches version accepted by PRL. Includes limits up to 10 TeV/c^2, published as supplementary material: http://prl.aps.org/supplemental/PRL/v109/i18/e181301 Please cite high mass limits as "Phys. Rev. Lett. 109, 181301 (2012), online supplementary material."
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
[16]  oai:arXiv.org:1101.3866  [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
Comments: 10 pages, 12 figures The updated version of the paper takes into account the new measurement of $^{136}$Xe 2$\nu$ $\beta\beta$ decay by EXO-200, with a half-life of (2.11$\pm0.04\pm$0.021)$\times10^{21}$ years
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.
[17]  oai:arXiv.org:1301.6620  [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
Comments: 5 pages, 3 figures; corrected caption of figure 3
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x 10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[18]  oai:arXiv.org:1211.0836  [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Comments: 12 pages, 4 figures
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
[19]  oai:arXiv.org:1209.3658  [pdf] - 673149
Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon
Comments: 14 pages, 8 figures
Submitted: 2012-09-17
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs {\gamma} rays and the energy of the Compton-scattered {\gamma} rays was measured with a high-purity germanium (HPGe) detector placed at different scattering angles. The excellent energy resolution of the HPGe detector allows the selection of events with Compton electrons of known energy in the LXe detector. We find that the scintillation yield initially increases as the electron energy decreases from 120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The measured scintillation yield was also measured with conversion electrons from the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal calibration source. We find that the scintillation yield of the 32.1 keV transition is compatible with that obtained from the Compton coincidence measurement. On the other hand, the yield for the 9.4keV transition is much higher than that measured for a Compton electron of the same energy. We interpret the enhancement in the scintillation yield as due to the enhanced recombination rate in the presence of Xe ions left from the 32.1 keV transition, which precedes the 9.4 keV one by 220 ns, on average.
[20]  oai:arXiv.org:1208.5762  [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Comments: 3 pages, no figures
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
[21]  oai:arXiv.org:1207.5432  [pdf] - 1125033
Measurement of the Quantum Efficiency of Hamamatsu R8520 Photomultipliers at Liquid Xenon Temperature
Comments:
Submitted: 2012-07-23
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to liquid xenon are being used to efficiently detect the 178 nm scintillation light in a variety of liquid xenon based particle detectors. Good knowledge of the performance of these photomultipliers under cryogenic conditions is needed to properly characterize these detectors. Here, we report on measurements of the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON Dark Matter Experiments. The quantum efficiency measurements at room temperature agree with the values provided by Hamamatsu. At low temperatures, between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative to the room temperature values.
[22]  oai:arXiv.org:1107.2155  [pdf] - 474250
The XENON100 Dark Matter Experiment
Comments: 23 pages, 27 figures; version accepted by journal
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs. The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of \sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[23]  oai:arXiv.org:1104.3121  [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
Comments: 3 pages, 3 figures
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.
[24]  oai:arXiv.org:1104.2549  [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
Comments: 5 pages, 5 figures; matches accepted version
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.
[25]  oai:arXiv.org:1103.0303  [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
Comments: 8 pages, 6 figures, matches accepted version
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[26]  oai:arXiv.org:1104.2587  [pdf] - 669518
New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
Comments: 14 pages, 13 figures
Submitted: 2011-04-13
Particle detectors that use liquid xenon (LXe) as detection medium are among the leading technologies in the search for dark matter weakly interacting massive particles (WIMPs). A key enabling element has been the low-energy detection threshold for recoiling nuclei produced by the interaction of WIMPs in LXe targets. In these detectors, the nuclear recoil energy scale is based on the LXe scintillation signal and thus requires knowledge of the relative scintillation efficiency of nuclear recoils, Leff. The uncertainty in Leff at low energies is the largest systematic uncertainty in the reported results from LXe WIMP searches at low masses. In the context of the XENON Dark Matter project, a new LXe scintillation detector has been designed and built specifically for the measurement of Leff at low energies, with an emphasis on maximizing the scintillation light detection efficiency to obtain the lowest possible energy threshold. We report new measurements of Leff at low energies performed with this detector. Our results suggest a Leff which slowly decreases with energy, from 0.144 +/- 0.009 at 15 keV down to 0.088 +0.014 -0.015 at 3 keV.
[27]  oai:arXiv.org:1005.0380  [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
Comments: 5 pages, 5 figures. Matches published version
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
[28]  oai:arXiv.org:0810.0274  [pdf] - 166670
New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
Comments: 8 pages, 8 figures
Submitted: 2008-10-01, last modified: 2010-05-16
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for maximum light collection. Greater than 95% of the interior surface of this detector was instrumented with photomultiplier tubes, giving a scintillation yield of 19.6 photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying constant around this value up to 10 keV. For higher energy recoils we measure a value around 20%, consistent with previously reported data. In light of this new measurement, the XENON10 experiment's results on spin-independent WIMP-nucleon cross section, which were calculated assuming a constant 0.19 relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to $9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from $4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30 GeV/c$^2$.
[29]  oai:arXiv.org:0912.2405  [pdf] - 1018742
Self-shielding effect of a single phase liquid xenon detector for direct dark matter search
Comments: 8 pages, 8 figures
Submitted: 2009-12-12
Liquid xenon is a suitable material for a dark matter search. For future large scale experiments, single phase detectors are attractive due to their simple configuration and scalability. However, in order to reduce backgrounds, they need to fully rely on liquid xenon's self-shielding property. A prototype detector was developed at Kamioka Observatory to establish vertex and energy reconstruction methods and to demonstrate the self-shielding power against gamma rays from outside of the detector. Sufficient self-shielding power for future experiments was obtained.