sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Licciardi, C.

Normalized to: Licciardi, C.

3 article(s) in total. 224 co-authors, from 1 to 3 common article(s). Median position in authors list is 45,0.

[1]  oai:arXiv.org:1905.12522  [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Comments: 18 pages, 12 figures
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
[2]  oai:arXiv.org:1903.03663  [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.; Giampa, P.; Retiere, F.; Kroeger, J.; Zhang, G.; Ward, M.; Margetak, P.; Lic, G.; Tsang, T.; Doria, L.; Kharusi, S. Al; Alfaris, M.; Anton, G.; Arnquist, I. J.; Badhrees, I.; Barbeau, P. S.; Beck, D.; Belov, V.; Bhatta, T.; Blatchford, J.; Brodsky, J. P.; Brown, E.; Brunner, T.; Cao, G. F.; Cao, L.; Cen, W. R.; Chambers, C.; Charlebois, S. A.; Chiu, M.; Cleveland, B.; Coon, M.; Craycraft, A.; Dalmasson, J.; Daniels, T.; Darroch, L.; Daugherty, S. J.; Croix, A. De St.; Der Mesrobian-Kabakian, A.; DeVoe, R.; Dilling, J.; Ding, Y. Y.; Dolinski, M. J.; Dragone, A.; Echevers, J.; Elbeltagi, M.; Fabris, L.; Fairbank, D.; Fairbank, W.; Farine, J.; Feyzbakhsh, S.; Fontaine, R.; Gautam, P.; Giacomini, G.; Gornea, R.; Gratta, G.; Hansen, E. V.; Heffner, M.; Hoppe, E. W.; Hoßl, J.; House, A.; Hughes, M.; Ito, Y.; Iverson, A.; Jamil, A.; Jewell, M. J.; Jiang, X. S.; Karelin, A.; Kaufman, L. J.; Kodroff, D.; Koffas, T.; Krucken, R.; Kuchenkov, A.; Kumar, K. S.; Lana, Y.; Larson, A.; Lenardo, B. G.; Leonarda, D. S.; Lik, S.; Li, Z.; Licciardi, C.; Linw, Y. H.; Lv, P.; MacLellan, R.; McElroy, T.; Medina-Peregrina, M.; Michel, T.; Mong, B.; Moore, D. C.; Murray, K.; Nakarmi, P.; Newby, R. J.; Ning, Z.; Njoya, O.; Nolet, F.; Nusair, O.; Odgers, K.; Odian, A.; Oriunno, M.; Orrell, J. L.; Ortega, G. S.; Ostrovskiy, I.; Overman, C. T.; Parent, S.; Piepkez, A.; Pocar, A.; Pratte, J. -F.; Qiu, D.; Radeka, V.; Raguzin, E.; Rescia, S.; Richman, M.; Robinson, A.; Rossignol, T.; Rowson, P. C.; Roy, N.; Saldanha, R.; Sangiorgio, S.; VIII, K. Skarpaas; Soma, A. K.; St-Hilaire, G.; Stekhanov, V.; Stiegler, T.; Sun, X. L.; Tarka, M.; Todd, J.; Tolba, T.; Totev, T. I.; Tsang, R.; Vachon, F.; Veeraraghavan, V.; Visser, G.; Vuilleumier, J. -L.; Wagenpfeil, M.; Walent, M.; Wang, Q.; Watkins, J.; Weber, M.; Wei, W.; Wen, L. J.; Wichoski, U.; Wu, S. X.; Wu, W. H.; Wu, X.; Xia, Q.; Yang, H.; Yang, L.; Yen, Y. -R.; Zeldovich, O.; Zhao, J.; Zhou, Y.; Ziegler, T.
Comments:
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[3]  oai:arXiv.org:1902.04031  [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Comments: 9 pages, 8 figures
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.