Normalized to: Licciardi, C.
[1]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[2]
oai:arXiv.org:1903.03663 [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.;
Giampa, P.;
Retiere, F.;
Kroeger, J.;
Zhang, G.;
Ward, M.;
Margetak, P.;
Lic, G.;
Tsang, T.;
Doria, L.;
Kharusi, S. Al;
Alfaris, M.;
Anton, G.;
Arnquist, I. J.;
Badhrees, I.;
Barbeau, P. S.;
Beck, D.;
Belov, V.;
Bhatta, T.;
Blatchford, J.;
Brodsky, J. P.;
Brown, E.;
Brunner, T.;
Cao, G. F.;
Cao, L.;
Cen, W. R.;
Chambers, C.;
Charlebois, S. A.;
Chiu, M.;
Cleveland, B.;
Coon, M.;
Craycraft, A.;
Dalmasson, J.;
Daniels, T.;
Darroch, L.;
Daugherty, S. J.;
Croix, A. De St.;
Der Mesrobian-Kabakian, A.;
DeVoe, R.;
Dilling, J.;
Ding, Y. Y.;
Dolinski, M. J.;
Dragone, A.;
Echevers, J.;
Elbeltagi, M.;
Fabris, L.;
Fairbank, D.;
Fairbank, W.;
Farine, J.;
Feyzbakhsh, S.;
Fontaine, R.;
Gautam, P.;
Giacomini, G.;
Gornea, R.;
Gratta, G.;
Hansen, E. V.;
Heffner, M.;
Hoppe, E. W.;
Hoßl, J.;
House, A.;
Hughes, M.;
Ito, Y.;
Iverson, A.;
Jamil, A.;
Jewell, M. J.;
Jiang, X. S.;
Karelin, A.;
Kaufman, L. J.;
Kodroff, D.;
Koffas, T.;
Krucken, R.;
Kuchenkov, A.;
Kumar, K. S.;
Lana, Y.;
Larson, A.;
Lenardo, B. G.;
Leonarda, D. S.;
Lik, S.;
Li, Z.;
Licciardi, C.;
Linw, Y. H.;
Lv, P.;
MacLellan, R.;
McElroy, T.;
Medina-Peregrina, M.;
Michel, T.;
Mong, B.;
Moore, D. C.;
Murray, K.;
Nakarmi, P.;
Newby, R. J.;
Ning, Z.;
Njoya, O.;
Nolet, F.;
Nusair, O.;
Odgers, K.;
Odian, A.;
Oriunno, M.;
Orrell, J. L.;
Ortega, G. S.;
Ostrovskiy, I.;
Overman, C. T.;
Parent, S.;
Piepkez, A.;
Pocar, A.;
Pratte, J. -F.;
Qiu, D.;
Radeka, V.;
Raguzin, E.;
Rescia, S.;
Richman, M.;
Robinson, A.;
Rossignol, T.;
Rowson, P. C.;
Roy, N.;
Saldanha, R.;
Sangiorgio, S.;
VIII, K. Skarpaas;
Soma, A. K.;
St-Hilaire, G.;
Stekhanov, V.;
Stiegler, T.;
Sun, X. L.;
Tarka, M.;
Todd, J.;
Tolba, T.;
Totev, T. I.;
Tsang, R.;
Vachon, F.;
Veeraraghavan, V.;
Visser, G.;
Vuilleumier, J. -L.;
Wagenpfeil, M.;
Walent, M.;
Wang, Q.;
Watkins, J.;
Weber, M.;
Wei, W.;
Wen, L. J.;
Wichoski, U.;
Wu, S. X.;
Wu, W. H.;
Wu, X.;
Xia, Q.;
Yang, H.;
Yang, L.;
Yen, Y. -R.;
Zeldovich, O.;
Zhao, J.;
Zhou, Y.;
Ziegler, T.
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N:
S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers
(SiPMs) as part of the development of a solution for the detection of liquid
xenon scintillation light for the nEXO experiment. Various SiPM features, such
as: dark noise, gain, correlated avalanches, direct crosstalk and Photon
Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs
were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233
\text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163
\text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse
in the $1 \upmu\text{s}$ interval following the trigger pulse of
$0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is
$0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are
within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two
different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of
$189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we
report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a
saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both
values are well below the $24\text{ }\%$ saturation PDE advertised by
Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over
voltage is below the nEXO PDE requirement. The first one instead yields a PDE
that is marginally close to meeting the nEXO specifications. This suggests that
with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an
alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[3]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.