sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Lhome, Emilie

Normalized to: Lhome, E.

2 article(s) in total. 65 co-authors. Median position in authors list is 12,0.

[1]  oai:arXiv.org:1412.0843  [pdf] - 1223432
Project overview and update on WEAVE: the next generation wide-field spectroscopy facility for the William Herschel Telescope
Comments: 11 pages, 11 Figures, Summary of a presentation to Astronomical Telescopes and Instrumentation 2014
Submitted: 2014-12-02
We present an overview of and status report on the WEAVE next-generation spectroscopy facility for the William Herschel Telescope (WHT). WEAVE principally targets optical ground-based follow up of upcoming ground-based (LOFAR) and space-based (Gaia) surveys. WEAVE is a multi-object and multi-IFU facility utilizing a new 2-degree prime focus field of view at the WHT, with a buffered pick-and-place positioner system hosting 1000 multi-object (MOS) fibres, 20 integral field units, or a single large IFU for each observation. The fibres are fed to a single spectrograph, with a pair of 8k(spectral) x 6k (spatial) pixel cameras, located within the WHT GHRIL enclosure on the telescope Nasmyth platform, supporting observations at R~5000 over the full 370-1000nm wavelength range in a single exposure, or a high resolution mode with limited coverage in each arm at R~20000. The project is now in the final design and early procurement phase, with commissioning at the telescope expected in 2017.
[2]  oai:arXiv.org:1109.3131  [pdf] - 1521897
Current results of the PERSEE testbench: the cophasing control and the polychromatic null rate
Comments: 17 pages, 10 figures, proceedings of the Optics+Photonics SPIE conference, San Diego, 2011
Submitted: 2011-09-14
Stabilizing a nulling interferometer at a nanometric level is the key issue to obtain deep null depths. The PERSEE breadboard has been designed to study and optimize the operation of a cophased nulling bench in the most realistic disturbing environment of a space mission. This presentation focuses on the current results of the PERSEE bench. In terms of metrology, we cophased at 0.33 nm rms for the piston and 80 mas rms for the tip/tilt (0.14% of the Airy disk). A Linear Quadratic Gaussian (LQG) control coupled with an unsupervised vibration identification allows us to maintain that level of correction, even with characteristic vibrations of nulling interferometry space missions. These performances, with an accurate design and alignment of the bench, currently lead to a polychromatic unpolarised null depth of 8.9E-6 stabilized at 3E-7 on the [1.65-2.45] \mum spectral band (37% bandwidth).