Normalized to: Leyton, M.
[1]
oai:arXiv.org:1705.05965 [pdf] - 1583512
Measurement of the directional sensitivity of DMTPC detectors
Deaconu, Cosmin;
Leyton, Michael;
Corliss, Ross;
Druitt, Gabriela;
Eggleston, Richard;
Guerrero, Natalia;
Henderson, Shawn;
Lopez, Jeremy;
Monroe, Jocelyn;
Fisher, Peter
Submitted: 2017-05-16, last modified: 2017-05-29
The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive
detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C
nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In
this paper, we employ measurements from two DMTPC detectors, with operating
pressures of 30-60 torr, to develop and validate a model of the directional
response and performance of such detectors as a function of recoil energy.
Using our model as a benchmark, we formulate the necessary specifications for a
scalable directional detector with sensitivity comparable to that of
current-generation counting (non-directional) experiments, which measure only
recoil energy. Assuming the performance of existing DMTPC detectors, as well as
current limits on the spin-dependent WIMP-nucleus cross section, we find that a
10-20 kg scale direction-sensitive detector is capable of correlating the
measured direction of nuclear recoils with the predicted direction of incident
dark matter particles and providing decisive (3$\sigma$) confirmation that a
candidate signal from a non-directional experiment was indeed induced by
elastic scattering of dark matter particles off of target nuclei.
[2]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.