sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Levine, I.

Normalized to: Levine, I.

14 article(s) in total. 629 co-authors, from 1 to 13 common article(s). Median position in authors list is 35,0.

[1]  oai:arXiv.org:1907.12509  [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
IceCube Collaboration; Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Alispach, C.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Argüelles, C.; Auffenberg, J.; Axani, S.; Backes, P.; Bagherpour, H.; Bai, X.; V., A. Balagopal; Barbano, A.; Barwick, S. W.; Bastian, B.; Baum, V.; Baur, S.; Bay, R.; Beatty, J. J.; Becker, K. -H.; Tjus, J. Becker; BenZvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Böser, S.; Botner, O.; Böttcher, J.; Bourbeau, E.; Bourbeau, J.; Bradascio, F.; Braun, J.; Bron, S.; Brostean-Kaiser, J.; Burgman, A.; Buscher, J.; Busse, R. S.; Carver, T.; Chen, C.; Cheung, E.; Chirkin, D.; Choi, S.; Classen, L.; Coleman, A.; Collin, G. H.; Conrad, J. M.; Coppin, P.; Correa, P.; Cowen, D. F.; Cross, R.; Dave, P.; De Clercq, C.; DeLaunay, J. J.; Dembinski, H.; Deoskar, K.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Diaz, A.; Díaz-Vélez, J. C.; Dujmovic, H.; Dunkman, M.; Dvorak, E.; Eberhardt, B.; Ehrhardt, T.; Eller, P.; Engel, R.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Felde, J.; Filimonov, K.; Finley, C.; Franckowiak, A.; Friedman, E.; Fritz, A.; Gaisser, T. K.; Gallagher, J.; Ganster, E.; Garrappa, S.; Gerhardt, L.; Ghorbani, K.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Griswold, S.; Günder, M.; Gündüz, M.; Haack, C.; Hallgren, A.; Halve, L.; Halzen, F.; Hanson, K.; Haungs, A.; Hebecker, D.; Heereman, D.; Heix, P.; Helbing, K.; Hellauer, R.; Henningsen, F.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hoinka, T.; Hokanson-Fasig, B.; Hoshina, K.; Huang, F.; Huber, M.; Huber, T.; Hultqvist, K.; Hünnefeld, M.; Hussain, R.; In, S.; Iovine, N.; Ishihara, A.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Jonske, F.; Joppe, R.; Kang, D.; Kang, W.; Kappes, A.; Kappesser, D.; Karg, T.; Karl, M.; Karle, A.; Katz, U.; Kauer, M.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Koirala, R.; Kolanoski, H.; Köpke, L.; Kopper, C.; Kopper, S.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Krückl, G.; Kulacz, N.; Kurahashi, N.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lazar, J. P.; Leonard, K.; Leszczyńska, A.; Leuermann, M.; Liu, Q. R.; Lohfink, E.; Mariscal, C. J. Lozano; Lu, L.; Lucarelli, F.; Lünemann, J.; Luszczak, W.; Lyu, Y.; Ma, W. Y.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Makino, Y.; Mallik, P.; Mallot, K.; Mancina, S.; Mariş, I. C.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Medina, A.; Meier, M.; Meighen-Berger, S.; Menne, T.; Merino, G.; Meures, T.; Micallef, J.; Mockler, D.; Momenté, G.; Montaruli, T.; Moore, R. W.; Morse, R.; Moulai, M.; Muth, P.; Nagai, R.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Pollmann, A. Obertacke; Oehler, M.; Olivas, A.; O'Murchadha, A.; O'Sullivan, E.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Park, N.; Peiffer, P.; Heros, C. Pérez de los; Philippen, S.; Pieloth, D.; Pinat, E.; Pizzuto, A.; Plum, M.; Porcelli, A.; Price, P. B.; Przybylski, G. T.; Raab, C.; Raissi, A.; Rameez, M.; Rauch, L.; Rawlins, K.; Rea, I. C.; Reimann, R.; Relethford, B.; Renschler, M.; Renzi, G.; Resconi, E.; Rhode, W.; Richman, M.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Safa, I.; Herrera, S. E. Sanchez; Sandrock, A.; Sandroos, J.; Santander, M.; Sarkar, S.; Sarkar, S.; Satalecka, K.; Schaufel, M.; Schieler, H.; Schlunder, P.; Schmidt, T.; Schneider, A.; Schneider, J.; Schröder, F. G.; Schumacher, L.; Sclafani, S.; Seckel, D.; Seunarine, S.; Shefali, S.; Silva, M.; Snihur, R.; Soedingrekso, J.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stamatikos, M.; Stanev, T.; Stein, R.; Steinmüller, P.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Strotjohann, N. L.; Stürwald, T.; Stuttard, T.; Sullivan, G. W.; Taboada, I.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tilav, S.; Tomankova, L.; Tönnis, C.; Toscano, S.; Tosi, D.; Trettin, A.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Turcotte, R.; Turley, C. F.; Ty, B.; Unger, E.; Elorrieta, M. A. Unland; Usner, M.; Vandenbroucke, J.; Van Driessche, W.; van Eijk, D.; van Eijndhoven, N.; Vanheule, S.; van Santen, J.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandkowsky, N.; Watson, T. B.; Weaver, C.; Weindl, A.; Weiss, M. J.; Weldert, J.; Wendt, C.; Werthebach, J.; Whelan, B. J.; Whitehorn, N.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, J.; Wood, T. R.; Woschnagg, K.; Wrede, G.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Yuan, T.; Collaboration, M. Zöcklein. PICO; :; Amole, C.; Ardid, M.; Arnquist, I. J.; Asner, D. M.; Baxter, D.; Behnke, E.; Bressler, M.; Broerman, B.; Cao, G.; Chen, C. J.; Chowdhury, U.; Clark, K.; Collar, J. I.; Cooper, P. S.; Crisler, M.; Crowder, G.; Cruz-Venegas, N. A.; Dahl, C. E.; Das, M.; Fallows, S.; Farine, J.; Felis, I.; Filgas, R.; Girard, F.; Giroux, G.; Hall, J.; Hardy, C.; Harris, O.; Hoppe, E. W.; Jin, M.; Klopfenstein, L.; Krauss, C. B.; Laurin, M.; Lawson, I.; Leblanc, A.; Levine, I.; Lippincott, W. H.; Mamedov, F.; Maurya, D.; Mitra, P.; Moore, C.; Nania, T.; Neilson, R.; Noble, A. J.; Oedekerk, P.; Ortega, A.; Piro, M. -C.; Plante, A.; Podviyanuk, R.; Priya, S.; Robinson, A. E.; Sahoo, S.; Scallon, O.; Seth, S.; Sonnenschein, A.; Starinski, N.; Štekl, I.; Sullivan, T.; Tardif, F.; Vázquez-Jáuregui, E.; Walkowski, N.; Wichoski, U.; Yan, Y.; Zacek, V.; Zhang, J.
Comments: 9 pages, 3 figures, 1 table. To appear in Eur.Phys.J. C
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at $\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+ \tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{ GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are independent of the DM velocity distribution.
[2]  oai:arXiv.org:1905.12522  [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Comments: 18 pages, 12 figures
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
[3]  oai:arXiv.org:1902.04031  [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Comments: 9 pages, 8 figures
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
[4]  oai:arXiv.org:1702.07666  [pdf] - 1581621
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Comments: 6 pages, 6 figures
Submitted: 2017-02-24, last modified: 2017-08-02
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
[5]  oai:arXiv.org:1611.01499  [pdf] - 1551948
Final Results of the PICASSO Dark Matter Search Experiment
Comments: 24 pages, 7 figures
Submitted: 2016-11-04, last modified: 2017-03-23
The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to allow fiducialization and removal of higher activity regions within the detectors. No signal consistent with dark matter was observed. We set limits for spin-dependent interactions on protons of $\sigma_p^{SD}$~=~1.32~$\times$~10$^{-2}$~pb (90\%~C.L.) at a WIMP mass of 20 GeV/c$^{2}$. In the spin-independent sector we exclude cross sections larger than $\sigma_p^{SI}$~=~4.86~$\times$~10$^{-5 }$~pb~(90\% C.L.) in the region around 7 GeV/c$^{2}$. The pioneering efforts of the PICASSO experiment have paved the way forward for a next generation detector incorporating much of this technology and experience into larger mass bubble chambers.
[6]  oai:arXiv.org:1601.03729  [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Comments:
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[7]  oai:arXiv.org:1510.07754  [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Comments: v3 to reflect published version
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
[8]  oai:arXiv.org:1503.00008  [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Comments: 6 pages, 6 figures, v2 to match published version
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
[9]  oai:arXiv.org:1304.6001  [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber
Comments: 5 pages, 3 figures
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.
[10]  oai:arXiv.org:1309.0910  [pdf] - 1178987
A Search for Astrophysical Burst Signals at the Sudbury Neutrino Observatory
Aharmim, B.; Ahmed, S. N.; Anthony, A. E.; Barros, N.; Beier, E. W.; Bellerive, A.; Beltran, B.; Bergevin, M.; Biller, S. D.; Boudjemline, K.; Boulay, M. G.; Cai, B.; Chan, Y. D.; Chauhan, D.; Chen, M.; Cleveland, B. T.; Cox, G. A.; Dai, X.; Deng, H.; Detwiler, J. A.; DiMarco, M.; Diamond, M. D.; Doe, P. J.; Doucas, G.; Drouin, P. -L.; Duncan, F. A.; Dunford, M.; Earle, E. D.; Elliott, S. R.; Evans, H. C.; Ewan, G. T.; Farine, J.; Fergani, H.; Fleurot, F.; Ford, R. J.; Formaggio, J. A.; Gagnon, N.; Goon, J. TM.; Graham, K.; Guillian, E.; Habib, S.; Hahn, R. L.; Hallin, A. L.; Hallman, E. D.; Harvey, P. J.; Hazama, R.; Heintzelman, W. J.; Heise, J.; Helmer, R. L.; Hime, A.; Howard, C.; Huang, M.; Jagam, P.; Jamieson, B.; Jelley, N. A.; Jerkins, M.; Keeter, K. J.; Klein, J. R.; Kormos, L. L.; Kos, M.; Kraus, C.; Krauss, C. B.; Krueger, A.; Kutter, T.; Kyba, C. C. M.; Lange, R.; Law, J.; Lawson, I. T.; Lesko, K. T.; Leslie, J. R.; Levine, I.; Loach, J. C.; MacLellan, R.; Majerus, S.; Mak, H. B.; Maneira, J.; Martin, R.; McCauley, N.; McDonald, A. B.; McGee, S. R.; Miller, M. L.; Monreal, B.; Monroe, J.; Nickel, B. G.; Noble, A. J.; O'Keeffe, H. M.; Oblath, N. S.; Ollerhead, R. W.; Gann, G. D. Orebi; Oser, S. M.; Ott, R. A.; Peeters, S. J. M.; Poon, A. W. P.; Prior, G.; Reitzner, S. D.; Rielage, K.; Robertson, B. C.; Robertson, R. G. H.; Schwendener, M. H.; Secrest, J. A.; Seibert, S. R.; Simard, O.; Simpson, J. J.; Sinclair, D.; Skensved, P.; Sonley, T. J.; Stonehill, L. C.; Tesic, G.; Tolich, N.; Tsui, T.; Van Berg, R.; VanDevender, B. A.; Virtue, C. J.; Wall, B. L.; Waller, D.; Tseung, H. Wan Chan; Wark, D. L.; Watson, P. J. S.; Wendland, J.; West, N.; Wilkerson, J. F.; Wilson, J. R.; Wouters, J. M.; Wright, A.; Yeh, M.; Zhang, F.; Zuber, K.
Comments:
Submitted: 2013-09-04
The Sudbury Neutrino Observatory (SNO) has confirmed the standard solar model and neutrino oscillations through the observation of neutrinos from the solar core. In this paper we present a search for neutrinos associated with sources other than the solar core, such as gamma-ray bursters and solar flares. We present a new method for looking for temporal coincidences between neutrino events and astrophysical bursts of widely varying intensity. No correlations were found between neutrinos detected in SNO and such astrophysical sources.
[11]  oai:arXiv.org:1204.3094  [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site
Comments: 9 pages, 7 figures, 2 tables
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.
[12]  oai:arXiv.org:1008.3518  [pdf] - 326586
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber
Comments: 4 pages, 4 figures V2 submitted to match journal version
Submitted: 2010-08-20, last modified: 2011-03-07
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg-day, consistent with a neutron background. This observation provides the strongest direct detection constraint to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$ GeV/c$^{2}$.
[13]  oai:arXiv.org:1011.4553  [pdf] - 383950
New Insights into Particle Detection with Superheated Liquids
Comments:
Submitted: 2010-11-20
We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$\alpha$,$\gamma$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy thresholds for $\alpha$-emitters are compared with test beam measurements using mono-energetic neutrons, as well as with theoretical predictions. Finally a model is presented which describes how the observed intensities of particle induced acoustic signals can be related to the dynamics of bubble growth in superheated liquids. An improved understanding of the bubble dynamics is an important first step in obtaining better discrimination between particle types interacting in detectors of this kind.
[14]  oai:arXiv.org:0804.2886  [pdf] - 11873
Improved Spin-Dependent WIMP Limits from a Bubble Chamber
Comments: This is the author's version of the work. It is posted here by permission of the AAAS for personal use, not for redistribution. The definitive version was published in Science 319, 15 February 2008, doi:10.1126/science.1149999
Submitted: 2008-04-17
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%. This illustrates the ability to employ bubble chambers in a new realm, the search for dark matter particles. Improved limits on the spin-dependent WIMP-proton scattering cross section are extracted from this first period. An extreme intrinsic insensitivity to the backgrounds commonly limiting these experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$) has been measured in operating conditions leading to the detection of low-energy nuclear recoils such as those expected from WIMPs.