sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Leriche, B.

Normalized to: Leriche, B.

5 article(s) in total. 245 co-authors, from 1 to 4 common article(s). Median position in authors list is 19,0.

[1]  oai:arXiv.org:1804.05645  [pdf] - 1810141
PILOT balloon-borne experiment in-flight performance
Comments:
Submitted: 2018-04-16, last modified: 2019-01-07
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Australia in april 2017. In this paper, we present the inflight performance of the instrument during these two flights. We concentrate on performances during flight#2, but allude to flight#1 performances if significantly different. We first present a short description of the instrument and the flights. We determine the time constants of our detectors combining inflight information from the signal decay following high energy particle impacts (glitches) and of our internal calibration source. We use these time constants to deconvolve the data timelines and analyse the optical quality of the instrument as measured on planets. We then analyse the structure and polarization of the instrumental background. We measure the detector response flat field and its time variations using the signal from the residual atmosphere and of our internal calibration source. Finally, we analyze the detector noise spectral and temporal properties. The in-flight performances are found to be satisfactory and globally in line with expectations from ground calibrations. We conclude by assessing the expected in-flight sensitivity of the instrument in light of the above in-flight performances.
[2]  oai:arXiv.org:1410.5760  [pdf] - 885266
PILOT: a balloon-borne experiment to measure the polarized FIR emission of dust grains in the interstellar medium
Comments: 17 pages, 13 figures. Presented at SPIE, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII. To be published in Proc. SPIE volume 9153
Submitted: 2014-10-13
Future cosmology space missions will concentrate on measuring the polarization of the Cosmic Microwave Background, which potentially carries invaluable information about the earliest phases of the evolution of our universe. Such ambitious projects will ultimately be limited by the sensitivity of the instrument and by the accuracy at which polarized foreground emission from our own Galaxy can be subtracted out. We present the PILOT balloon project which will aim at characterizing one of these foreground sources, the polarization of the dust continuum emission in the diffuse interstellar medium. The PILOT experiment will also constitute a test-bed for using multiplexed bolometer arrays for polarization measurements. We present the results of ground tests obtained just before the first flight of the instrument.
[3]  oai:arXiv.org:1407.2545  [pdf] - 1215555
The ArT\'eMiS wide-field submillimeter camera: preliminary on-sky performances at 350 microns
Comments: 11 pages, 11 figures. Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII, June 24, 2014. To be published in Proceedings of SPIE Volume 9153
Submitted: 2014-07-09
ArTeMiS is a wide-field submillimeter camera operating at three wavelengths simultaneously (200, 350 and 450 microns). A preliminary version of the instrument equipped with the 350 microns focal plane, has been successfully installed and tested on APEX telescope in Chile during the 2013 and 2014 austral winters. This instrument is developed by CEA (Saclay and Grenoble, France), IAS (France) and University of Manchester (UK) in collaboration with ESO. We introduce the mechanical and optical design, as well as the cryogenics and electronics of the ArTeMiS camera. ArTeMiS detectors are similar to the ones developed for the Herschel PACS photometer but they are adapted to the high optical load encountered at APEX site. Ultimately, ArTeMiS will contain 4 sub-arrays at 200 microns and 2x8 sub-arrays at 350 and 450 microns. We show preliminary lab measurements like the responsivity of the instrument to hot and cold loads illumination and NEP calculation. Details on the on-sky commissioning runs made in 2013 and 2014 at APEX are shown. We used planets (Mars, Saturn, Uranus) to determine the flat-field and to get the flux calibration. A pointing model was established in the first days of the runs. The average relative pointing accuracy is 3 arcsec. The beam at 350 microns has been estimated to be 8.5 arcsec, which is in good agreement with the beam of the 12 m APEX dish. Several observing modes have been tested, like On-The-Fly for beam-maps or large maps, spirals or raster of spirals for compact sources. With this preliminary version of ArTeMiS, we concluded that the mapping speed is already more than 5 times better than the previous 350 microns instrument at APEX. The median NEFD at 350 microns is 600 mJy.s1/2, with best values at 300 mJy.s1/2. The complete instrument with 5760 pixels and optimized settings will be installed during the first half of 2015.
[4]  oai:arXiv.org:1101.2039  [pdf] - 1051324
Planck early results: first assessment of the High Frequency Instrument in-flight performance
Planck HFI Core Team; Ade, P. A. R.; Aghanim, N.; Ansari, R.; Arnaud, M.; Ashdown, M.; Aumont, J.; Banday, A. J.; Bartelmann, M.; Bartlett, J. G.; Battaner, E.; Benabed, K.; Benot, A.; Bernard, J. -P.; Bersanelli, M.; Bhatia, R.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Boulanger, F.; Bradshaw, T.; Brelle, E.; Bucher, M.; Camus, P.; Cardoso, J. -F.; Catalano, A.; Challinor, A.; Chamballu, A.; Charra, J.; Charra, M.; Chary, R. -R.; Chiang, C.; Church, S.; Clements, D. L.; Colombi, S.; Couchot, F.; Coulais, A.; Cressiot, C.; Crill, B. P.; Crook, M.; de Bernardis, P.; Delabrouille, J.; Delouis, J. -M.; Désert, F. -X.; Dolag, K.; Dole, H.; Doré, O.; Douspis, M.; Efstathiou, G.; Eng, P.; Filliard, C.; Forni, O.; Fosalba, P.; Fourmond, J. -J.; Ganga, K.; Giard, M.; Girard, D.; Giraud-Héraud, Y.; Gispert, R.; Gorski, K. M.; Gratton, S.; Griffin, M.; Guyot, G.; Haissinski, J.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Hernandez-Monteagudo, C.; Hildebrandt, S. R.; Hills, R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Huenberger, K. M.; Jae, A. H.; Jones, W. C.; Kaplan, J.; Kneissl, R.; Knox, L.; Lagache, G.; Lamarre, J. -M.; Lami, P.; Lange, A. E.; Lasenby, A.; Lavabre, A.; Lawrence, C. R.; Leriche, B.; Leroy, C.; Longval, Y.; Macas-Perez, J. F.; Maciaszek, T.; MacTavish, C. J.; Maei, B.; Mandolesi, N.; Mann, R.; Mansoux, B.; Masi, S.; Matsumura, T.; McGehee, P.; Melin, J. -B.; Mercier, C.; Miville-Deschnes, M. -A.; Moneti, A.; Montier, L.; Mortlock, D.; Murphy, A.; Nati, F.; Nettereld, C. B.; Norgaard-Nielsen, H. U.; North, C.; Noviello, F.; Novikov, D.; Osborne, S.; Paine, C.; Pajot, F.; Patanchon, G.; Peacocke, T.; Pearson, T. J.; Perdereau, O.; Perotto, L.; Piacentini, F.; Piat, M.; Plaszczynski, S.; Pointecouteau, E.; Pons, R.; Ponthieu, N.; Prezeau, G.; Prunet, S.; Puget, J. -L.; Reach, W. T.; Renault, C.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Santos, D.; Savini, G.; Schaefer, B. M.; Shellard, P.; Spencer, L.; Starck, J. -L.; Stassi, P.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sygnet, J. -F.; Tauber, J. A.; Thum, C.; Torre, J. -P.; Touze, F.; Tristram, M.; Van Leeuwen, F.; Vibert, L.; Vibert, D.; Wade, L. A.; Wandelt, B. D.; White, S. D. M.; Wiesemeyer, H.; Woodcraft, A.; Yurchenko, V.; Yvon, D.; Zacchei, A.
Comments: Submitted to A&A. 22 pages, 6 tables, 21 figures. One of a set of simultaneous papers for the Planck Mission
Submitted: 2011-01-11
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during ground testing. Observations of Mars, Jupiter, and Saturn verified both the optical system and the time response of the detection chains. The optical beams are close to predictions from physical optics modeling. The time response of the detection chains is close to pre-launch measurements. The detectors suffer from an unexpected high flux of cosmic rays related to low solar activity. Due to the redundancy of Planck's observations strategy, the removal of a few percent of data contaminated by glitches does not affect significantly the sensitivity. The cosmic rays heat up significantly the bolometer plate and the modulation on periods of days to months of the heat load creates a common drift of all bolometer signals which do not affect the scientific capabilities. Only the high energy cosmic rays showers induce inhomogeneous heating which is a probable source of low frequency noise.
[5]  oai:arXiv.org:astro-ph/9912385  [pdf] - 110048
Calibration and First light of the Diabolo photometer at the Millimetre and Infrared Testa Grigia Observatory
Comments: 10 pages, LaTeX, 12 figures, accepted for publication in Astronomy and Astrophysics Supplement Series
Submitted: 1999-12-17
We have designed and built a large-throughput dual channel photometer, Diabolo. This photometer is dedicated to the observation of millimetre continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect and of anisotropies of the 3K background. We describe the optical layout and filtering system of the instrument, which uses two bolometric detectors for simultaneous observations in two frequency channels at 1.2 and 2.1 mm. The bolometers are cooled to a working temperature of 0.1 K provided by a compact dilution cryostat. The photometric and angular responses of the instrument are measured in the laboratory. First astronomical light was detected in March 1995 at the focus of the new Millimetre and Infrared Testa Grigia Observatory (MITO) Telescope. The established sensitivity of the system is of 7 mK_RJ s^1/2$. For a typical map of at least 10 beams, with one hour of integration per beam, one can achieve the rms values of y_SZ ~ 7 10^-5 and the 3K background anisotropy Delta T/T ~ 7 10^-5, in winter conditions. We also report on a novel bolometer AC readout circuit which allows for the first time total power measurements on the sky. This technique alleviates (but does not forbid) the use of chopping with a secondary mirror. This technique and the dilution fridge concept will be used in future scan--modulated space instrument like the ESA Planck mission project.