Normalized to: Leriche, B.
[1]
oai:arXiv.org:1804.05645 [pdf] - 1810141
PILOT balloon-borne experiment in-flight performance
Mangilli, A.;
Foënard, G.;
Aumont, J.;
Hughes, A.;
Mot, B.;
Bernard, J-Ph.;
Lacourt, A.;
Ristorcelli, I.;
Longval, Y.;
Ade, P.;
André, Y.;
Bautista, L.;
deBernardis, P.;
Boulade, O.;
Bousqet, F.;
Bouzit, M.;
Buttice, V.;
Charra, M.;
Crane, B.;
Doumayrou, E.;
Dubois, J. P.;
Engel, C.;
Griffin, M.;
Grabarnik, S.;
Hargrave, P.;
Laureijs, R.;
Leriche, B.;
Maestre, S.;
Maffei, B.;
Marty, C.;
Marty, W.;
Masi, S.;
Misawa, R.;
Montel, J.;
Montier, L.;
Narbonne, J.;
Pajot, F.;
Pérot, E.;
Pimentao, J.;
Pisano, G.;
Ponthieu, N.;
Rodriguez, L.;
Roudil, G.;
Salatino, M.;
Savini, G.;
Simonella, O.;
Saccoccio, M.;
Stever, S.;
Tauber, J.;
Tibbs, C.;
Tucker, C.
Submitted: 2018-04-16, last modified: 2019-01-07
The Polarized Instrument for Long-wavelength Observation of the Tenuous
interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring
the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A
first PILOT flight (flight#1) of the experiment took place from Timmins,
Ontario, Canada, in September 2015 and a second flight (flight#2) took place
from Alice Springs, Australia in april 2017. In this paper, we present the
inflight performance of the instrument during these two flights. We concentrate
on performances during flight#2, but allude to flight#1 performances if
significantly different. We first present a short description of the instrument
and the flights. We determine the time constants of our detectors combining
inflight information from the signal decay following high energy particle
impacts (glitches) and of our internal calibration source. We use these time
constants to deconvolve the data timelines and analyse the optical quality of
the instrument as measured on planets. We then analyse the structure and
polarization of the instrumental background. We measure the detector response
flat field and its time variations using the signal from the residual
atmosphere and of our internal calibration source. Finally, we analyze the
detector noise spectral and temporal properties. The in-flight performances are
found to be satisfactory and globally in line with expectations from ground
calibrations. We conclude by assessing the expected in-flight sensitivity of
the instrument in light of the above in-flight performances.
[2]
oai:arXiv.org:1410.5760 [pdf] - 885266
PILOT: a balloon-borne experiment to measure the polarized FIR emission
of dust grains in the interstellar medium
Misawa, R.;
Bernard, J-Ph.;
Ade, P.;
Andre, Y.;
deBernardis, P.;
Bouzit, M.;
Charra, M.;
Crane, B.;
Dubois, J. P.;
Engel, C.;
Griffin, M.;
Hargrave, P.;
Leriche, B.;
Longval, Y.;
Maes, S.;
Marty, C.;
Marty, W.;
Masi, S.;
Mot, B.;
Narbonne, J.;
Pajot, F.;
Pisano, G.;
Ponthieu, N.;
Ristorcelli, I.;
Rodriguez, L.;
Roudil, G.;
Salatino, M.;
Savini, G.;
Tucker, C.
Submitted: 2014-10-13
Future cosmology space missions will concentrate on measuring the
polarization of the Cosmic Microwave Background, which potentially carries
invaluable information about the earliest phases of the evolution of our
universe. Such ambitious projects will ultimately be limited by the sensitivity
of the instrument and by the accuracy at which polarized foreground emission
from our own Galaxy can be subtracted out. We present the PILOT balloon project
which will aim at characterizing one of these foreground sources, the
polarization of the dust continuum emission in the diffuse interstellar medium.
The PILOT experiment will also constitute a test-bed for using multiplexed
bolometer arrays for polarization measurements. We present the results of
ground tests obtained just before the first flight of the instrument.
[3]
oai:arXiv.org:1407.2545 [pdf] - 1215555
The ArT\'eMiS wide-field submillimeter camera: preliminary on-sky
performances at 350 microns
Reveret, Vincent;
André, Philippe;
Pennec, Jean Le;
Talvard, Michel;
Agnèse, Patrick;
Arnaud, Agnès;
Clerc, Laurent;
de Breuck, Carlos;
Cigna, Jean-Charles;
Delisle, Cyrille;
Doumayrou, Eric;
Duband, Lionel;
Dubreuil, Didier;
Dumaye, Luc;
Ercolani, Eric;
Gallais, Pascal;
Groult, Elodie;
Jourdan, Thierry;
Leriche, Bernadette;
Maffei, Bruno;
Lortholary, Michel;
Martignac, Jérôme;
Rabaud, Wilfried;
Relland, Johan;
Rodriguez, Louis;
Vandeneynde, Aurélie;
Visticot, François
Submitted: 2014-07-09
ArTeMiS is a wide-field submillimeter camera operating at three wavelengths
simultaneously (200, 350 and 450 microns). A preliminary version of the
instrument equipped with the 350 microns focal plane, has been successfully
installed and tested on APEX telescope in Chile during the 2013 and 2014
austral winters. This instrument is developed by CEA (Saclay and Grenoble,
France), IAS (France) and University of Manchester (UK) in collaboration with
ESO. We introduce the mechanical and optical design, as well as the cryogenics
and electronics of the ArTeMiS camera. ArTeMiS detectors are similar to the
ones developed for the Herschel PACS photometer but they are adapted to the
high optical load encountered at APEX site. Ultimately, ArTeMiS will contain 4
sub-arrays at 200 microns and 2x8 sub-arrays at 350 and 450 microns. We show
preliminary lab measurements like the responsivity of the instrument to hot and
cold loads illumination and NEP calculation. Details on the on-sky
commissioning runs made in 2013 and 2014 at APEX are shown. We used planets
(Mars, Saturn, Uranus) to determine the flat-field and to get the flux
calibration. A pointing model was established in the first days of the runs.
The average relative pointing accuracy is 3 arcsec. The beam at 350 microns has
been estimated to be 8.5 arcsec, which is in good agreement with the beam of
the 12 m APEX dish. Several observing modes have been tested, like On-The-Fly
for beam-maps or large maps, spirals or raster of spirals for compact sources.
With this preliminary version of ArTeMiS, we concluded that the mapping speed
is already more than 5 times better than the previous 350 microns instrument at
APEX. The median NEFD at 350 microns is 600 mJy.s1/2, with best values at 300
mJy.s1/2. The complete instrument with 5760 pixels and optimized settings will
be installed during the first half of 2015.
[4]
oai:arXiv.org:1101.2039 [pdf] - 1051324
Planck early results: first assessment of the High Frequency Instrument
in-flight performance
Planck HFI Core Team;
Ade, P. A. R.;
Aghanim, N.;
Ansari, R.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Banday, A. J.;
Bartelmann, M.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Benot, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Bock, J. J.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Boulanger, F.;
Bradshaw, T.;
Brelle, E.;
Bucher, M.;
Camus, P.;
Cardoso, J. -F.;
Catalano, A.;
Challinor, A.;
Chamballu, A.;
Charra, J.;
Charra, M.;
Chary, R. -R.;
Chiang, C.;
Church, S.;
Clements, D. L.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Cressiot, C.;
Crill, B. P.;
Crook, M.;
de Bernardis, P.;
Delabrouille, J.;
Delouis, J. -M.;
Désert, F. -X.;
Dolag, K.;
Dole, H.;
Doré, O.;
Douspis, M.;
Efstathiou, G.;
Eng, P.;
Filliard, C.;
Forni, O.;
Fosalba, P.;
Fourmond, J. -J.;
Ganga, K.;
Giard, M.;
Girard, D.;
Giraud-Héraud, Y.;
Gispert, R.;
Gorski, K. M.;
Gratton, S.;
Griffin, M.;
Guyot, G.;
Haissinski, J.;
Harrison, D.;
Helou, G.;
Henrot-Versillé, S.;
Hernandez-Monteagudo, C.;
Hildebrandt, S. R.;
Hills, R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Huenberger, K. M.;
Jae, A. H.;
Jones, W. C.;
Kaplan, J.;
Kneissl, R.;
Knox, L.;
Lagache, G.;
Lamarre, J. -M.;
Lami, P.;
Lange, A. E.;
Lasenby, A.;
Lavabre, A.;
Lawrence, C. R.;
Leriche, B.;
Leroy, C.;
Longval, Y.;
Macas-Perez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maei, B.;
Mandolesi, N.;
Mann, R.;
Mansoux, B.;
Masi, S.;
Matsumura, T.;
McGehee, P.;
Melin, J. -B.;
Mercier, C.;
Miville-Deschnes, M. -A.;
Moneti, A.;
Montier, L.;
Mortlock, D.;
Murphy, A.;
Nati, F.;
Nettereld, C. B.;
Norgaard-Nielsen, H. U.;
North, C.;
Noviello, F.;
Novikov, D.;
Osborne, S.;
Paine, C.;
Pajot, F.;
Patanchon, G.;
Peacocke, T.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Piacentini, F.;
Piat, M.;
Plaszczynski, S.;
Pointecouteau, E.;
Pons, R.;
Ponthieu, N.;
Prezeau, G.;
Prunet, S.;
Puget, J. -L.;
Reach, W. T.;
Renault, C.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Roudier, G.;
Rowan-Robinson, M.;
Rusholme, B.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Shellard, P.;
Spencer, L.;
Starck, J. -L.;
Stassi, P.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sunyaev, R.;
Sygnet, J. -F.;
Tauber, J. A.;
Thum, C.;
Torre, J. -P.;
Touze, F.;
Tristram, M.;
Van Leeuwen, F.;
Vibert, L.;
Vibert, D.;
Wade, L. A.;
Wandelt, B. D.;
White, S. D. M.;
Wiesemeyer, H.;
Woodcraft, A.;
Yurchenko, V.;
Yvon, D.;
Zacchei, A.
Submitted: 2011-01-11
The Planck High Frequency Instrument (HFI) is designed to measure the
temperature and polarization anisotropies of the Cosmic Microwave Background
and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545
and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5'
(217 GHz and higher). HFI has been operating flawlessly since launch on 14 May
2009. The bolometers cooled to 100 mK as planned. The settings of the readout
electronics, such as the bolometer bias current, that optimize HFI's noise
performance on orbit are nearly the same as the ones chosen during ground
testing. Observations of Mars, Jupiter, and Saturn verified both the optical
system and the time response of the detection chains. The optical beams are
close to predictions from physical optics modeling. The time response of the
detection chains is close to pre-launch measurements. The detectors suffer from
an unexpected high flux of cosmic rays related to low solar activity. Due to
the redundancy of Planck's observations strategy, the removal of a few percent
of data contaminated by glitches does not affect significantly the sensitivity.
The cosmic rays heat up significantly the bolometer plate and the modulation on
periods of days to months of the heat load creates a common drift of all
bolometer signals which do not affect the scientific capabilities. Only the
high energy cosmic rays showers induce inhomogeneous heating which is a
probable source of low frequency noise.
[5]
oai:arXiv.org:astro-ph/9912385 [pdf] - 110048
Calibration and First light of the Diabolo photometer at the Millimetre
and Infrared Testa Grigia Observatory
Benoit, A.;
Zagury, F.;
Coron, N.;
De Petris, M.;
Desert, F. -X.;
Giard, M.;
Bernard, J. -P.;
Crussaire, J. -P.;
Dambier, G.;
de Bernardis, P.;
Delabrouille, J.;
De Luca, A.;
de Marcillac, P.;
Jegoudez, G.;
Lamarre, J. -M.;
Leblanc, J.;
Lepeltier, J. -P.;
Leriche, B.;
Mainella, G.;
Narbonne, J.;
Pajot, F.;
Pons, R.;
Puget, J. -L.;
Pujol, S.;
Recouvreur, G.;
Serra, G.;
Soglasnova, V.;
Torre, J. -P.;
Vozzi, B.
Submitted: 1999-12-17
We have designed and built a large-throughput dual channel photometer,
Diabolo. This photometer is dedicated to the observation of millimetre
continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect
and of anisotropies of the 3K background. We describe the optical layout and
filtering system of the instrument, which uses two bolometric detectors for
simultaneous observations in two frequency channels at 1.2 and 2.1 mm. The
bolometers are cooled to a working temperature of 0.1 K provided by a compact
dilution cryostat. The photometric and angular responses of the instrument are
measured in the laboratory. First astronomical light was detected in March 1995
at the focus of the new Millimetre and Infrared Testa Grigia Observatory (MITO)
Telescope. The established sensitivity of the system is of 7 mK_RJ s^1/2$. For
a typical map of at least 10 beams, with one hour of integration per beam, one
can achieve the rms values of y_SZ ~ 7 10^-5 and the 3K background anisotropy
Delta T/T ~ 7 10^-5, in winter conditions. We also report on a novel bolometer
AC readout circuit which allows for the first time total power measurements on
the sky. This technique alleviates (but does not forbid) the use of chopping
with a secondary mirror. This technique and the dilution fridge concept will be
used in future scan--modulated space instrument like the ESA Planck mission
project.