Normalized to: Leman, S.
[1]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[2]
oai:arXiv.org:1304.3706 [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Di Stefano, P. C. F.;
Silva, E. do Couto e;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Lopez-Asamar, E.;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhan, J.
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles
(WIMPs) with the Si detectors of the CDMS II experiment. This report describes
a blind analysis of the first data taken with CDMS II's full complement of
detectors in 2006-2007; results from this exposure using the Ge detectors have
already been presented. We observed no candidate WIMP-scattering events in an
exposure of 55.9 kg-days before analysis cuts, with an expected background of
~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a
recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10
GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon
spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude
parameter space for spin-independent WIMP-nucleon elastic scattering that is
relevant to recent searches for low-mass WIMPs.
[3]
oai:arXiv.org:1203.1309 [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Anderson, A. J.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dragowsky, M. R.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D. C.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D.;
Serfass, B.;
Speller, D.;
Sundqvist, K. M.;
Tarka, M.;
Thakur, R. B.;
Villano, A. N.;
Welliver, B.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the
Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground
Laboratory. Such a modulation could be produced by interactions from Weakly
Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no
evidence for annual modulation in the event rate of veto-anticoincident
single-detector interactions consistent with nuclear recoils, and constrain the
magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9
keVnr energy range at the 99% confidence level. These results disfavor an
explanation for the reported modulation in the 1.2-3.2 keVee energy range in
CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs
at >98% confidence. For events consistent with electron recoils, no significant
modulation is observed for either single- or multiple-detector interactions in
the 3.0-7.4 keVee range.
[4]
oai:arXiv.org:1109.1193 [pdf] - 1083863
Review Article: Physics and Monte Carlo Techniques as Relevant to
Cryogenic, Phonon and Ionization Readout of CDMS Radiation-Detectors
Submitted: 2011-09-06, last modified: 2012-06-26
This review discusses detector physics and Monte Carlo techniques for
cryogenic, radiation detectors that utilize combined phonon and ionization
readout. A general review of cryogenic phonon and charge transport is provided
along with specific details of the Cryogenic Dark Matter Search detector
instrumentation. In particular this review covers quasidiffusive phonon
transport, which includes phonon focusing, anharmonic decay and isotope
scattering. The interaction of phonons in the detector surface is discussed
along with the downconversion of phonons in superconducting films. The charge
transport physics include a mass tensor which results from the crystal band
structure and is modeled with a Herring Vogt transformation. Charge scattering
processes involve the creation of Neganov-Luke phonons. Transition-edge-sensor
(TES) simulations include a full electric circuit description and all thermal
processes including Joule heating, cooling to the substrate and thermal
diffusion within the TES, the latter of which is necessary to model
normal-superconducting phase separation. Relevant numerical constants are
provided for these physical processes in germanium, silicon, aluminum and
tungsten. Random number sampling methods including inverse cumulative
distribution function (CDF) and rejection techniques are reviewed. To improve
the efficiency of charge transport modeling, an additional second order inverse
CDF method is developed here along with an efficient barycentric coordinate
sampling method of electric fields. Results are provided in a manner that is
convenient for use in Monte Carlo and references are provided for validation of
these models.
[5]
oai:arXiv.org:1109.3620 [pdf] - 967055
Modeling phase-separated transition-edge sensors in SuperCDMS detectors
Submitted: 2011-09-16, last modified: 2011-09-23
The SuperCDMS experiment implements transition-edge sensors to measure
athermal phonons produced by nuclear recoils in Ge crystals. We discuss a
numerical simulation of these TES devices and a procedure for tuning the free
model parameters to data, which reproduces superconducting-to-normal phase
separation within a TES. This tuning provides insight into the behavior of the
TESs, allows us to study the phase-separation length to optimize our detector
design, and is integrated into a more complete simulation of the phonon and
charge physics of SuperCDMS detectors.
[6]
oai:arXiv.org:1109.1198 [pdf] - 1083866
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with
low Transition-Edge-Sensor Transition Temperature
Leman, S. W.;
McCarthy, K. A.;
Brink, P. L.;
Cabrera, B.;
Cherry, M.;
Silva, E. Do Couto E;
Figueroa-Feliciano, E.;
Kim, P.;
Mirabolfathi, N.;
Pyle, M.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.;
Young, B. A.
Submitted: 2011-09-06
We present results on phonon quasidiffusion and Transition Edge Sensor (TES)
studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium
crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed
with 59.5 keV gamma-rays from an Am-241 calibration source. We compare
calibration data with results from a Monte Carlo which includes phonon
quasidiffusion and the generation of phonons created by charge carriers as they
are drifted across the detector by ionization readout channels. The phonon
energy is then parsed into TES based phonon readout channels and input into a
TES simulator.
[7]
oai:arXiv.org:1109.1327 [pdf] - 1937687
Simulations of Noise in Phase-Separated Transition-Edge Sensors for
SuperCDMS
Submitted: 2011-09-06
We briefly review a simple model of superconducting-normal phase-separation
in transition-edge sensors in the SuperCDMS experiment. After discussing some
design considerations relevant to the TES in the detectors, we study noise
sources in both the phase-separated and phase-uniform cases. Such simulations
are valuable for optimizing the critical temperature and TES length of future
SuperCDMS detectors.
[8]
oai:arXiv.org:1109.0551 [pdf] - 1934625
Validation of Phonon Physics in the CDMS Detector Monte Carlo
McCarthy, K. A.;
Leman, S. W.;
Anderson, A. J.;
Brandt, D.;
Brink, P. L.;
Cabrera, B.;
Cherry, M.;
Silva, E. Do Couto E;
Cushman, P.;
Doughty, T.;
Figueroa-Feliciano, E.;
Kim, P.;
Mirabolfathi, N.;
Novak, L.;
Partridge, R.;
Pyle, M.;
Reisetter, A.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.
Submitted: 2011-09-02
The SuperCDMS collaboration is a dark matter search effort aimed at detecting
the scattering of WIMP dark matter from nuclei in cryogenic germanium targets.
The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at
achieving a deeper understanding of the performance of the SuperCDMS detectors
and aiding the dark matter search analysis. We present results from validation
of the phonon physics described in the CDMS-DMC and outline work towards
utilizing it in future WIMP search analyses.
[9]
oai:arXiv.org:1108.6245 [pdf] - 1934624
Comparison of CDMS [100] and [111] oriented germanium detectors
Leman, S. W.;
Hertel, S. A.;
Kim, P.;
Cabrera, B.;
Silva, E. Do Couto E;
Figueroa-Feliciano, E.;
McCarthy, K. A.;
Resch, R.;
Sadoulet, B.;
Sundqvist, K. M.
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter
$\times$ 1" thick target masses as particle detectors. The target is
instrumented with both phonon and ionization sensors and comparison of energy
in each channel provides event-by-event classification of electron and nuclear
recoils. Fiducial volume is determined by the ability to obtain good phonon and
ionization signal at a particular location. Due to electronic band structure in
germanium, electron mass is described by an anisotropic tensor with heavy mass
aligned along the symmetry axis defined by the [111] Miller index (L valley),
resulting in large lateral component to the transport. The spatial distribution
of electrons varies significantly for detectors which have their longitudinal
axis orientations described by either the [100] or [111] Miller indices.
Electric fields with large fringing component at high detector radius also
affect the spatial distribution of electrons and holes. Both effects are
studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is
discussed.
[10]
oai:arXiv.org:1108.6244 [pdf] - 1934623
Time Evolution of Electric Fields in CDMS Detectors
Leman, S. W.;
Brandt, D.;
Brink, P. L.;
Cabrera, B.;
Chagani, H.;
Cherry, M.;
Cushman, P.;
Silva, E. Do Couto E;
Doughty, T.;
Figueroa-Feliciano, E.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Pyle, M.;
Reisetter, A.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.;
Young, B. A.;
Zhang, J.
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter x 1"
thick target masses as particle detectors. The target is instrumented with both
phonon and ionization sensors, the later providing a $\sim$1 V cm$^{-1}$
electric field in the detector bulk. Cumulative radiation exposure which
creates $\sim 200\times 10^6$ electron-hole pairs is sufficient to produce a
comparable reverse field in the detector thereby degrading the ionization
channel performance. To study this, the existing CDMS detector Monte Carlo has
been modified to allow for an event by event evolution of the bulk electric
field, in three spatial dimensions. Our most resent results and interpretation
are discussed.
[11]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[12]
oai:arXiv.org:1012.5078 [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Razeti, M.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
[13]
oai:arXiv.org:1011.2482 [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.
[14]
oai:arXiv.org:0907.1438 [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS
experiment
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Beaty, J.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
DeJongh, F.;
Dragowsky, M. R.;
Duong, L.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fritts, M.;
Golwala, S. R.;
Grant, D. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Mahapatra, R.;
Mandic, V.;
Moore, D.;
McCarthy, K. A.;
Mirabolfathi, N.;
Nelson, H.;
Ogburn, R. W.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Wang, G.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Collaboration, the CDMS
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.