sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Lechner, P.

Normalized to: Lechner, P.

3 article(s) in total. 31 co-authors, from 1 to 2 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:astro-ph/0309424  [pdf] - 59251
SIMBOL-X : a new generation hard X-ray telescope
Comments: 12 pages, 16 fig., Proc. SPIE conf. 5168, San Diego, Aug. 2003
Submitted: 2003-09-16
SIMBOL-X is a hard X-ray mission, operating in the 0.5-70 keV range, which is proposed by a consortium of European laboratories for a launch around 2010. Relying on two spacecraft in a formation flying configuration, SIMBOL-X uses a 30 m focal length X-ray mirror to achieve an unprecedented angular resolution (30 arcsec HEW) and sensitivity (100 times better than INTEGRAL below 50 keV) in the hard X-ray range. SIMBOL-X will allow to elucidate fundamental questions in high energy astrophysics, such as the physics of accretion onto Black Holes, of acceleration in quasar jets and in supernovae remnants, or the nature of the hard X-ray diffuse emission. The scientific objectives and the baseline concepts of the mission and hardware design are presented.
[2]  oai:arXiv.org:astro-ph/0302500  [pdf] - 55127
Development of Silicon Strip Detectors for a Medium Energy Gamma-ray Telescope
Comments: 9 pages, 13 figures, to appear in NIM-A (Proceedings of the 9th European Symposium on Semiconductor Detectors)
Submitted: 2003-02-24
We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to form a stack, the "tracker," with the goal of recording the paths of energetic electrons produced by Compton-scatter and pair-production interactions. Each layer of the tracker is composed of a 3 x 3 array of 500 micron thick silicon wafers, each 6 cm x 6 cm and fitted with 128 orthogonal p and n strips on opposite sides (470 micron pitch). The strips are biased using the punch-through principle and AC-coupled via metal strips separated from the strip implant by an insulating oxide/nitride layer. The strips from adjacent wafers in the 3 x 3 array are wire-bonded in series and read out by 128-channel TA1.1 ASICs, creating a total 19 cm x 19 cm position-sensitive area. At 20 degrees C a typical energy resolution of 15-20 keV FWHM, a position resolution of 290 microns, and a time resolution of ~1 microsec is observed.
[3]  oai:arXiv.org:astro-ph/0206028  [pdf] - 49659
A fast X-ray timing capability on XEUS
Comments: 7 pages, 8 figures. To appear in the proceedings of the workshop "XEUS-studying the evolution of the hot universe" held in Garching, March 11-13, 2002, eds. G. Hasinger, Th. Boller and A. Parmar, MPE report
Submitted: 2002-06-03
Fast X-ray timing can be used to probe strong gravity fields around collapsed objects and constrain the equation of state of dense matter in neutron stars. These studies require extremely good photon statistics. In view of the huge collecting area of its mirrors, XEUS could make a unique contribution to this field. For this reason, we propose to include a fast X-ray timing capability in the focal plane of the XEUS mirrors. We briefly outline the scientific motivation for such a capability. We compute some sensitivity estimates, which indicate that XEUS could provide better than an order of magnitude sensitivity improvement over the Rossi X-ray Timing Explorer. Finally, we present a possible detector implementation, which could be an array of small size silicon drift detectors operated out of focus.