Normalized to: Lechner, P.
[1]
oai:arXiv.org:astro-ph/0309424 [pdf] - 59251
SIMBOL-X : a new generation hard X-ray telescope
Ferrando, P.;
Arnaud, M.;
Cordier, B.;
Goldwurm, A.;
Limousin, O.;
Paul, J.;
Sauvageot, J. L.;
Petrucci, P. O.;
Mouchet, M.;
Bignami, G.;
Citterio, O.;
Campana, S.;
Pareschi, G.;
Tagliaferri, G.;
Briel, U.;
Hasinger, G.;
Strueder, L.;
Lechner, P.;
Kendziorra, E.;
Turner, M.
Submitted: 2003-09-16
SIMBOL-X is a hard X-ray mission, operating in the 0.5-70 keV range, which is
proposed by a consortium of European laboratories for a launch around 2010.
Relying on two spacecraft in a formation flying configuration, SIMBOL-X uses a
30 m focal length X-ray mirror to achieve an unprecedented angular resolution
(30 arcsec HEW) and sensitivity (100 times better than INTEGRAL below 50 keV)
in the hard X-ray range. SIMBOL-X will allow to elucidate fundamental questions
in high energy astrophysics, such as the physics of accretion onto Black Holes,
of acceleration in quasar jets and in supernovae remnants, or the nature of the
hard X-ray diffuse emission. The scientific objectives and the baseline
concepts of the mission and hardware design are presented.
[2]
oai:arXiv.org:astro-ph/0302500 [pdf] - 55127
Development of Silicon Strip Detectors for a Medium Energy Gamma-ray
Telescope
Submitted: 2003-02-24
We report on the design, production, and testing of advanced double-sided
silicon strip detectors under development at the Max-Planck-Institute as part
of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are
designed to form a stack, the "tracker," with the goal of recording the paths
of energetic electrons produced by Compton-scatter and pair-production
interactions. Each layer of the tracker is composed of a 3 x 3 array of 500
micron thick silicon wafers, each 6 cm x 6 cm and fitted with 128 orthogonal p
and n strips on opposite sides (470 micron pitch). The strips are biased using
the punch-through principle and AC-coupled via metal strips separated from the
strip implant by an insulating oxide/nitride layer. The strips from adjacent
wafers in the 3 x 3 array are wire-bonded in series and read out by 128-channel
TA1.1 ASICs, creating a total 19 cm x 19 cm position-sensitive area. At 20
degrees C a typical energy resolution of 15-20 keV FWHM, a position resolution
of 290 microns, and a time resolution of ~1 microsec is observed.
[3]
oai:arXiv.org:astro-ph/0206028 [pdf] - 49659
A fast X-ray timing capability on XEUS
Submitted: 2002-06-03
Fast X-ray timing can be used to probe strong gravity fields around collapsed
objects and constrain the equation of state of dense matter in neutron stars.
These studies require extremely good photon statistics. In view of the huge
collecting area of its mirrors, XEUS could make a unique contribution to this
field. For this reason, we propose to include a fast X-ray timing capability in
the focal plane of the XEUS mirrors. We briefly outline the scientific
motivation for such a capability. We compute some sensitivity estimates, which
indicate that XEUS could provide better than an order of magnitude sensitivity
improvement over the Rossi X-ray Timing Explorer. Finally, we present a
possible detector implementation, which could be an array of small size silicon
drift detectors operated out of focus.