Normalized to: Lechanoine-Leluc, C.
[1]
oai:arXiv.org:1703.04210 [pdf] - 1547762
Gain factor and parameter settings optimization of the new gamma-ray
burst polarimeter POLAR
Zhang, X. F.;
Hajdas, W.;
Xiao, H. L.;
Wen, X.;
Wu, B. B.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
He, J. J.;
Kole, M.;
Kong, M. N.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wu, X.;
Xiong, S. L.;
Xu, M.;
Zhang, L.;
Zhang, L. Y.;
Zhang, P.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-03-12, last modified: 2017-03-14
As a space-borne detector POLAR is designed to conduct hard X-ray
polarization measurements of gamma-ray bursts on the statistically significant
sample of events and with an unprecedented accuracy. During its development
phase a number of tests, calibrations runs and verification measurements were
carried out in order to validate instrument functionality and optimize
operational parameters. In this article we present results on gain optimization
togeter with verification data obtained in the course of broad laboratory and
environmental tests. In particular we focus on exposures to the $^{137}$Cs
radioactive source and determination of the gain dependence on the high voltage
for all 1600 detection channels of the polarimeter. Performance of the
instrument is described in detail with respect to the dynamic range, energy
resolution and temperature dependence. Gain optimization algorithms and
response non-uniformity studies are also broadly discussed. Results presented
below constitute important parts for development of the POLAR calibration and
operation database.
[2]
oai:arXiv.org:1612.04098 [pdf] - 1533322
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB
Polarimeter
Kole, M.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
He, J. J.;
Kong, M. N.;
Kong, S. W.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rutczynska, A.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. J.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Xiong, S. L.;
Xu, H. H.;
Xu, M.;
Zhang, J.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2016-12-13
Gamma-ray polarimetry is a new powerful tool to study the processes
responsible for the emission from astrophysical sources and the environments in
which this emission takes place. Few successful polarimetric measurements have
however been performed thus far in the gamma-ray energy band due to the
difficulties involved. POLAR is a dedicated polarimeter designed to perform
high precision measurements of the polarization of the emission from gamma-ray
burst in the 50-500 keV energy range. This new polarimeter is expected to
detect approximately 50 gamma-ray bursts per year while performing high
precision polarization measurements on approximately 10 bursts per year. The
instrument was launched into lower earth orbit as part of the second Chinese
space lab, the Tiangong-2, on September 15th 2016 and has been taking data
successfully since being switched on one week after. The instrument uses a
segmented scintillator array consisting of 1600 plastic scintillator bars, read
out by 25 flat-panel multi-anode photomultipliers, to measure the Compton
scattering angles of incoming photons. The small segmentation and relatively
large uniform effective area allow the instrument to measure the polarization
of a large number of transient events, such as gamma-ray bursts, with an
unprecedented precision during its two year life-time. The final flight model
underwent detailed calibration prior to launch as well as intensive space
qualification tests, a summary of which will be presented in this paper. The
instrument design will be discussed first followed by an overview of the
on-ground tests, finally the in-orbit behavior as measured during the first
weeks of the mission will be presented.
[3]
oai:arXiv.org:1011.3789 [pdf] - 262890
A method to localize gamma-ray bursts using POLAR
Suarez-Garcia, E.;
Haas, D.;
Hajdas, W.;
Lamanna, G.;
Lechanoine-Leluc, C.;
Marcinkowski, R.;
Mtchedlishvili, A.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rybka, D.;
Vialle, J. -P.
Submitted: 2010-11-16
The hard X-ray polarimeter POLAR aims to measure the linear polarization of
the 50-500 keV photons arriving from the prompt emission of gamma-ray bursts
(GRBs). The position in the sky of the detected GRBs is needed to determine
their level of polarization. We present here a method by which, despite of the
polarimeter incapability of taking images, GRBs can be roughly localized using
POLAR alone. For this purpose scalers are attached to the output of the 25
multi-anode photomultipliers (MAPMs) that collect the light from the POLAR
scintillator target. Each scaler measures how many GRB photons produce at least
one energy deposition above 50 keV in the corresponding MAPM. Simulations show
that the relative outputs of the 25 scalers depend on the GRB position. A
database of very strong GRBs simulated at 10201 positions has been produced.
When a GRB is detected, its location is calculated searching the minimum of the
chi2 obtained in the comparison between the measured scaler pattern and the
database. This GRB localization technique brings enough accuracy so that the
error transmitted to the 100% modulation factor is kept below 10% for GRBs with
fluence Ftot \geq 10^(-5) erg cm^(-2) . The POLAR localization capability will
be useful for those cases where no other instruments are simultaneously
observing the same field of view.