Normalized to: Lebreton, L.
[1]
oai:arXiv.org:1504.05865 [pdf] - 1579629
First detection of tracks of radon progeny recoils by MIMAC
Riffard, Q.;
Santos, D.;
Bosson, G.;
Bourrion, O.;
Descombes, T.;
Fourel, C.;
Guillaudin, O.;
Muraz, J. -F.;
Colas, P.;
Ferrer-Ribas, E.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Lebreton, L.;
Maire, D.
Submitted: 2015-04-22, last modified: 2017-06-20
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
[2]
oai:arXiv.org:1602.01738 [pdf] - 1483260
MIMAC low energy electron-recoil discrimination measured with fast
neutrons
Riffard, Q.;
Santos, D.;
Guillaudin, O.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Descombes, T.;
Muraz, J. -F.;
Lebreton, L.;
Maire, D.;
Colas, P.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Brunner, J.;
Tao, C.
Submitted: 2016-02-04, last modified: 2016-07-04
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter
detector project. Direct dark matter experiments need a high level of
electron/recoil discrimination to search for nuclear recoils produced by
WIMP-nucleus elastic scattering. In this paper, we proposed an original method
for electron event rejection based on a multivariate analysis applied to
experimental data acquired using monochromatic neutron fields. This analysis
shows that a $10^5$ rejection power is reachable for electron/recoil
discrimination. Moreover, the efficiency was estimated by a Monte-Carlo
simulation showing that a 105 electron rejection power is reached with a
$86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range
and $94.67\pm0.19$\% considering a 5~keV lower threshold.
[3]
oai:arXiv.org:1305.2360 [pdf] - 776422
In situ measurement of the electron drift velocity for upcoming
directional Dark Matter detectors
Billard, J.;
Mayet, F.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-05-10, last modified: 2014-01-28
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.
[4]
oai:arXiv.org:1401.1009 [pdf] - 766735
Measurement of the electron drift velocity for directional dark matter
detectors
Mayet, F.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2014-01-06
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm
CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.
[5]
oai:arXiv.org:1311.0616 [pdf] - 1180445
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional
detection
Santos, D.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. F.;
Richer, J. P.;
Riffard, Q.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-11-04
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from neutrons, the ultimate background
for dark matter direct detection. This strategy requires both a precise
measurement of the energy down to a few keV and 3D reconstruction of tracks
down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has
developed in the last years an original prototype detector based on the direct
coupling of large pixelized micromegas with a special developed fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The first bi-chamber prototype has been installed at
Modane, underground laboratory in June 2012. The first undergournd background
events, the gain stability and calibration are shown. The first spectrum of
nuclear recoils showing 3D tracks coming from the radon progeny is presented.
[6]
oai:arXiv.org:1306.4173 [pdf] - 681293
Dark Matter directional detection with MIMAC
Riffard, Q.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. -F.;
Richer, J. -P.;
Santos, D.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-06-18
Directional detection is a promising direct Dark Matter (DM) search strategy.
The angular distribution of the nuclear recoil tracks from WIMP events should
present an anisotropy in galactic coordinates. This strategy requires both a
measurement of the recoil energy with a threshold of about 5 keV and 3D recoil
tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is
being developed. In June 2012, a bi-chamber prototype was installed at the LSM
(Laboratoire Souterrain de Modane). A preliminary analysis of the first four
months data taking allowed, for the first time, the observation of recoils from
the $\mathrm{^{222}Rn}$ progeny.
[7]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.
[8]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[9]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
AttiƩ, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[10]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[11]
oai:arXiv.org:1012.1166 [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Allaoua, A.;
Golabek, C.;
Lebreton, L.
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H
and 19F) obtained with a low mono-energetic neutron field are presented. The
discovery potential of this search strategy is discussed and illustrated by a
realistic case accessible to MIMAC.
[12]
oai:arXiv.org:1001.2983 [pdf] - 32880
Directional detection of galactic Dark Matter
Mayet, F.;
Billard, J.;
Bernard, G.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Koumeir, C.;
Richer, J. P.;
Santos, D.;
Colas, P.;
Ferer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2010-01-18
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating geniune WIMP events from background ones. We present
technical progress on gaseous detectors as well as recent phenomenological
studies, allowing the design and construction of competitive experiments.
[13]
oai:arXiv.org:0909.0654 [pdf] - 901600
A prototype of a directional detector for non-baryonic dark matter
search: MIMAC (Micro-TPC Matrix of Chambers)
Grignon, C.;
Bernard, G.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2009-09-03, last modified: 2009-10-30
We have developed a micro-tpc using a pixelized bulk micromegas coupled to
dedicated acquisition electronics as a read-out allowing to reconstruct the
three dimensional track of a few keV recoils. The prototype has been tested
with the Amande facility at the IRSN-Cadarache providing monochromatic
neutrons. The first results concerning discrimination of a few keV electrons
and proton recoils are presented.